期刊文献+
共找到3,522篇文章
< 1 2 177 >
每页显示 20 50 100
Operating Parameters of the District Heating Substation Cooperating With the Installation of Technological Air Conditioning With High Efficiency of Heat Recovery
1
作者 Żarski Kazimierz Kryża Mariusz 《Chinese Business Review》 2024年第1期1-12,共12页
The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchange... The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated. 展开更多
关键词 ventilation of operating theatre air conditioning flow control in heating circuit
下载PDF
A Case Study:Distribution of Bacterial and Fungal Aerosols in Air-Conditioning Systems in Shaanxi History Museum
2
作者 LI An-gui,HOU Juan-juan,JI Zeng-bao,ZHU Xiao-bin(School of Environmental & Municipal Engineering,Xi’an University of Architecture and Technology,Xi’an,Shaanxi 710055,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期10-14,共5页
In order to investigate the bacteria and fungi aerosol characteristic distribution in HVAC-system and its components at Shaanxi History Museum.Measurements were performed to probe the bacteria and fungi aerosol in HVA... In order to investigate the bacteria and fungi aerosol characteristic distribution in HVAC-system and its components at Shaanxi History Museum.Measurements were performed to probe the bacteria and fungi aerosol in HVAC systems,located at Xi'an city,China.The results showed that there was fungi growth inside the ventilation ducts,fungi contamination was worse than bacteria,and both of them were distributed into occupied space with the air supply ducts.The dominating genera of fungi was found to be Penicillium spp.and Aspergillus spp.,which was respectively 46.1% and 20.7% in settling fungi,and the dominating genera of fungi in dust were Cladosporium spp.and Penicillium spp.,which was 41.8% and 30.1% respectively.It suggests that available measures to improve and control the performance of HVAC-systems such as the maintenance,management and cleaning should be taken to prevent this pollution and to develop strategies to keep this pollution away. 展开更多
关键词 central air conditioning MICROBE bacteria FUNGI contamination field experiment
下载PDF
An Energy-Saving Control Strategy on Central Air-Conditioning System 被引量:1
3
作者 Sheng Xing 1 , Yin Juan 2 , Shang Jingfu 3 , Yu Yang 4 , Wu Zhangxian 5 1. State Grid Information & Telecommunication Co., Ltd. 2. China Huadian Finance Corporation Limited 3. State Grid AC Engineering Construction Company 4. Northeast China Electric Power Dispatching & Communication Center 5. North China Electric Power University 《Electricity》 2011年第4期62-66,共5页
An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature con... An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy. 展开更多
关键词 central air-conditioning predictive control energy saving time-delay system simulated annealing
下载PDF
Study on the Elman Neural Network Operation Control Strategy of the Central Air Conditioning Chilled Water System
4
作者 Jianwei Li Qingchang Ren +1 位作者 Hai Long Zengxi Feng 《World Journal of Engineering and Technology》 2019年第2期73-82,共10页
The stable operation of the central air conditioning water system always is a major difficulty for the control profession. Paper focus on the water system with multi variable, strong coupling, nonlinear, large time de... The stable operation of the central air conditioning water system always is a major difficulty for the control profession. Paper focus on the water system with multi variable, strong coupling, nonlinear, large time delay characteristics, presented use feed forward coupling compensation method, to eliminate the coupling effect between temperature and pressure. In this paper, the Elman neural network controller is designed for the first time, and the simulation results show that the response time of Elman neural network controller is shorter, the system is more stable and the overshoot is small. 展开更多
关键词 FEED Forward Coupling Compensation central air conditioning Water system ALWAYS Temperature DIFFERENCE CONTROL Pressure DIFFERENCE CONTROL ELMAN Neural Network
下载PDF
Energy performance assessment on central air-conditioning system of commercial building: A case study in China
5
作者 周璇 练斯甄 +1 位作者 闫军威 康英姿 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第8期3168-3179,共12页
Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipmen... Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system. 展开更多
关键词 中央空调系统 性能评价 商业大厦 节能 室内环境质量 冷却水系统 中国 评估方法
下载PDF
Numerical Analysis on Ventilating and Air Conditioning Scheme of Shenyang Subway Station 被引量:1
6
作者 李伟 那艳玲 《Transactions of Tianjin University》 EI CAS 2007年第2期147-151,共5页
Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and opera... Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer. 展开更多
关键词 沈阳 地铁车站 通风换气 空气调节方案 温度场 气流场
下载PDF
Alternative ventilation strategies in U.S.offices:Comprehensive assessment and sensitivity analysis of energy saving potential 被引量:5
7
作者 Adams Rackes Michael S.Waring 侯恩哲 《建筑节能》 CAS 2017年第5期109-109,共1页
Mature technologies exist to reduce the heating,ventilation,and air-conditioning(HVAC) energy associated with ventilation and use ventilation proactively to save energy.This study investigated the energy use impacts i... Mature technologies exist to reduce the heating,ventilation,and air-conditioning(HVAC) energy associated with ventilation and use ventilation proactively to save energy.This study investigated the energy use impacts in U.S.office buildings of multiple alternative ventilation strategies that combined:economizing,demand controlled ventilation(DCV),supply air temperature reset(SR),and/or a doubled ventilation rate.We used energy simulations in a Monte Carlo analysis,sampling 17 building inputs and varying locations to match the climate zone distribution of the U.S.office stock.Results indicated the possibility for significant savings compared to a baseline that ventilated constantly at a minimum rate in both a small office type with a constant air volume(CAV) HVAC system and a medium office type with a variable air volume(VAV) system.In 95%of instances,HVAC source energy savings were 5-25%in the small-CAV office(median:11%) and 6-42%in the medium-VAV office(median:27%).In the small-CAV office,DCV typically saved the most energy,usually from heating,and heating degree days and occupant density were decisive influences.In the medium-VAV office,economizing and SR were most important,DCV usually only had minor impacts,and zone temperature setpoints,along with climate indicators,were the critical influences.Other than infiltration,envelope characteristics did not strongly influence energy impacts.The untapped primary energy savings of alternative ventilation strategies over the 74%of U.S.office floorspace reasonably represented by our modeling was estimated at 36 TWh per year,with an annual value of U.S.$ 1.25 billion. 展开更多
关键词 ventilation heating MATCH constantly doubled SAVING conditioning POSSIBILITY INFILTRATION STOCK
下载PDF
Design of Fuzzy Controller for Central Air Conditioner
8
作者 谢娟 耿庆波 《Journal of Beijing Institute of Technology》 EI CAS 2003年第S1期20-24,共5页
A structure of central air conditioning system in building and its running pattern are proposed in order to perform optimum energy saving strategy. The design of room temperature controller is taken as an example to d... A structure of central air conditioning system in building and its running pattern are proposed in order to perform optimum energy saving strategy. The design of room temperature controller is taken as an example to discuss the design of fuzzy controller using common microprogrammed control unit (MCU) in detail. Based on fuzzy theory the query control tables fixed in read only memory (ROM) of MCU are established to realize the energy saving in the room temperature controller and the reasoning procedure is analyzed. The diagram of hardware design and the flow chart of software of room temperature controller are presented. The results show that the proposed method is practical and effective to achieve the energy saving goal. 展开更多
关键词 central air conditioning system room temperature controller fuzzy control energy saving
下载PDF
Window Air Conditioners Transition and Restriction in Saudi Arabia
9
作者 Essam Al Ammar Abdulhakim Bin Dayil 《Journal of Power and Energy Engineering》 2022年第5期1-21,共21页
This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spr... This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spreading inside KSA than the split type, also it will discuss some restrictions for trading and manufacturing of air conditioner devices inside KSA besides some restrictions on market and buildings to achieve the objective of reducing the consumption of energy which become a big trend in kingdom vision 2030. The results of this suggesting solution will help the decision-makers to start its plan for execution as it has a big difference between using window type from 2022 till 2030 and if we stop its sales and replace by an efficient one of split AC type in energy consumption in addition to CO<sub>2</sub> emission reduction and decreasing of energy cost, hence our kingdom can save petroleum raw materials and keeping the environment to become clean from pollutants so that these resources are delivered to successive generations correct and clean as we received them from those before us. 展开更多
关键词 air Conditioners (AC) Terawatt-Hour (TWh) Saudi Standards Metrology and Quality Organization (SASO) Energy-Efficiency Ratio (EER) High Efficiency air conditioning (HEAC) Carbon Dioxide (CO2) Heating ventilation and air conditioning (HVAC) Saudi Building Code (SBC) Saudi Energy Efficiency Center (SEEC)
下载PDF
Optimal Scheduling of Residential Heating, Ventilation and Air Conditioning Based on Deep Reinforcement Learning
10
作者 Mingchao Xia Fangjian Chen +3 位作者 Qifang Chen Siwei Liu Yuguang Song Te Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第5期1596-1605,共10页
Residential heating, ventilation and air conditioning(HVAC) provides important demand response resources for the new power system with high proportion of renewable energy. Residential HAVC scheduling strategies that a... Residential heating, ventilation and air conditioning(HVAC) provides important demand response resources for the new power system with high proportion of renewable energy. Residential HAVC scheduling strategies that adapt to realtime electricity price signals formulated by demand response program and ambient temperature can significantly reduce electricity costs while ensuring occupants' comfort. However, since the pricing process and weather conditions are affected by many factors, conventional model-based method is difficult to meet the scheduling requirements in complex environments. To solve this problem, we propose an adaptive optimal scheduling strategy for residential HVAC based on deep reinforcement learning(DRL) method. The scheduling problem can be regarded as a Markov decision process(MDP). The proposed method can adaptively learn the state transition probability to make economical decision under the tolerance violations. Specifically, the residential thermal parameters obtained by the leastsquares parameter estimation(LSPE) can provide a basis for the state transition probability of MDP. Daily simulations are verified under the electricity prices and temperature data sets, and numerous experimental results demonstrate the effectiveness of the proposed method. 展开更多
关键词 Residential heating ventilation and air conditioning(HVAC) SCHEDULING deep reinforcement learning leastsquares parameter estimation(LSPE)
原文传递
中央空调负荷精细化调控双层优化技术研究 被引量:1
11
作者 陆旦宏 李思琦 +3 位作者 杨婷 王玉莹 查云龙 倪敏珏 《电力需求侧管理》 2024年第1期23-30,共8页
针对当前中央空调系统粗放式调节不能准确释放调控潜力的问题,深入分析中央空调各子系统工作原理与调控方式,提出基于双层优化的中央空调负荷精细化调控技术方案。首先,面向实际工程实践需求建立建筑湿热标度模型;然后,建立以舒适度和... 针对当前中央空调系统粗放式调节不能准确释放调控潜力的问题,深入分析中央空调各子系统工作原理与调控方式,提出基于双层优化的中央空调负荷精细化调控技术方案。首先,面向实际工程实践需求建立建筑湿热标度模型;然后,建立以舒适度和经济性优化目标函数为主的上层调控模型,采用Shapley值法对温湿设定值的进行分配;接着,建立以各子系统优化组合能耗最低为优化目标函数的下层调控模型,采用蚁群算法对优化目标函数进行求解;之后,通过求解双层模型,制定包括末端风机、冷冻水泵以及冷水机组等组件的精细化调控策略;最后,通过多个算例验证所提中央空调负荷精细化调控技术方案的正确性与有效性。 展开更多
关键词 中央空调负荷 双层优化 精细化调控 建筑湿热标度模型 蚁群算法 SHAPLEY值法
下载PDF
日本HEAS-02-2022《医院设施设计指南(空调设备篇)》介绍
12
作者 沈晋明 刘燕敏 《暖通空调》 2024年第1期56-63,共8页
日本HEAS-02《医院设施设计指南(空调设备篇)》已经持续应用了30多年,对我国医院建设影响较大。历经4次修订,最新颁布的2022版是由医学主席在疫情中主持修订的,鉴于气溶胶新的传播特性提出了相应的合适措施。在医疗环境控制方面提出了... 日本HEAS-02《医院设施设计指南(空调设备篇)》已经持续应用了30多年,对我国医院建设影响较大。历经4次修订,最新颁布的2022版是由医学主席在疫情中主持修订的,鉴于气溶胶新的传播特性提出了相应的合适措施。在医疗环境控制方面提出了许多新的思路与措施,局部修订了空气洁净度级别和各医疗科室的通风要求。依据感染管理风险评估及推荐强度与证据质量实施合理的医疗环境控制,并对一些关注点进行了澄清。 展开更多
关键词 医院通风空调 标准与措施 医疗环境与感染控制 推荐强度 证据质量 设计指南 标准解读
下载PDF
某有机化学实验室项目通风空调系统设计
13
作者 吴玲红 《暖通空调》 2024年第2期47-51,共5页
有机化学实验往往会产生对人体有害的气体,有效的通风空调系统可以避免有害物泄漏,以保证实验人员在工作环境里的安全和健康。不同的有机化学实验室要求不同,其通风空调系统设计也有相应的不同要求。合成实验室通风量大,但对房间温湿度... 有机化学实验往往会产生对人体有害的气体,有效的通风空调系统可以避免有害物泄漏,以保证实验人员在工作环境里的安全和健康。不同的有机化学实验室要求不同,其通风空调系统设计也有相应的不同要求。合成实验室通风量大,但对房间温湿度要求不高;分析仪器实验室中仪器设备较多,发热量较大,且对环境温湿度有一定的要求。本文结合某实际工程,对不同功能化学实验室通风量的确定、新风送风温度及空调设置情况和通风系统控制进行了介绍。 展开更多
关键词 有机化学实验室 合成实验室 分析仪器实验室 排风柜 通风空调系统 新风 变风量控制
下载PDF
暖通空调给排水管道的表面改性与性能研究
14
作者 赵辉 赵海波 《成都工业学院学报》 2024年第2期23-28,共6页
为提升暖通空调铜合金排水管的表面性能,采用化学镀的方法在铜合金排水管表面制备了Ni-P/TiN镀层,研究镀液中TiN质量浓度对化学镀层物相组成、表面及截面形貌、硬度和耐磨性能的影响。结果表明,无镀层的铜合金基体主要物相为CuZn和CuZn5... 为提升暖通空调铜合金排水管的表面性能,采用化学镀的方法在铜合金排水管表面制备了Ni-P/TiN镀层,研究镀液中TiN质量浓度对化学镀层物相组成、表面及截面形貌、硬度和耐磨性能的影响。结果表明,无镀层的铜合金基体主要物相为CuZn和CuZn5,表面镀层主要由非晶Ni组成;在基础镀液中适当添加TiN会形成镀层质量较好的含有胞状颗粒的镀层,而过量的TiN添加会使得镀层质量恶化。相较铜合金基体,表面镀层的硬度明显更高,且表面镀层硬度会随着镀液中TiN质量浓度的增加而增大;当TiN质量浓度为10 g/L时,表面镀层的硬度和磨损率分别为633 HV0.1和0.93×10^(-8)g/(r·N),具有相对较好的耐磨性,此时的磨损机制主要为氧化磨损。 展开更多
关键词 暖通空调管道 铜合金 表面镀层 镀液中TiN质量浓度 形貌 摩擦学性能
下载PDF
海洋平台HVAC系统减噪技术研究
15
作者 高山 陈丽 +1 位作者 赵特 易慧 《中国修船》 2024年第3期58-60,共3页
文章结合海洋平台供热通风与空气调节(HVAC)系统噪声控制的现状,重点介绍了平台HVAC系统噪声对人员和设备的影响;分析了HVAC系统噪声的来源,包括机组本身运行时产生的噪声、管线内流体流动噪声等;提出了设计和安装阶段HVAC系统噪声控制... 文章结合海洋平台供热通风与空气调节(HVAC)系统噪声控制的现状,重点介绍了平台HVAC系统噪声对人员和设备的影响;分析了HVAC系统噪声的来源,包括机组本身运行时产生的噪声、管线内流体流动噪声等;提出了设计和安装阶段HVAC系统噪声控制的要点,如选择低噪声设备、合理布置管线、采用隔振器和消声器等。 展开更多
关键词 海洋平台 供热通风与空气调节 噪声
下载PDF
Characteristic studies of heat sources and performance analysis of free-cooling assisted air conditioning and ventilation systems for working faces of mineral mines
16
作者 Rang Tu Lijuan Huang +2 位作者 Aibing Jin Mingfeng Zhang Xiao Hai 《Building Simulation》 SCIE EI CSCD 2021年第6期1725-1736,共12页
High temperature heat hazard at mineral mine becomes more and more serious as the increase of mining depth.Heat sources at working faces of mineral mines are complex and are of different characteristics,presenting new... High temperature heat hazard at mineral mine becomes more and more serious as the increase of mining depth.Heat sources at working faces of mineral mines are complex and are of different characteristics,presenting new challenges for air conditioning systems.In this paper,heat sources at four types of working faces are summarized and their characteristics are investigated.Based on this,simplified equations,which are linear with length of working faces,are proposed to calculate heat dissipation rates.So that the main heat sources of different working faces can be found,and cooling load of air conditioning systems can be calculated.Then,considering main heat sources of coal mines,a typical working face is designed to investigate performances of different ventilation systems and air conditioning systems.Simulation results show that segmented ventilation systems(SC)and heat shield assisted centralized ventilation systems(CCHS)can realize much better temperature distributions at working faces.However,cooling load can be greatly reduced for CCHS,when untreated air is supplied to the coal seam side.Based on this,free cooling assisted air conditioning systems are designed,and annual average energy efficiency ratio(EERann)of the systems are investigated and compared between direct evaporate cooling and indirect evaporate cooling(IEC).For SC,as compared with scenarios without free-cooling,IEC can increase EERann by 15%-23%and 22%-32%under Benxi and Datong ambient conditions,respectively.Besides,to ensure high EERann,CCHS is preferred and it is essential to increase thermal insulation of air ducts. 展开更多
关键词 working face heat sources characteristics air ventilation system free cooling air conditioning energy efficiency
原文传递
A concept of capillary active,dynamic insulation integrated with heating,cooling and ventilation,air conditioning system
17
作者 Mark BOMBERG 《Frontiers of Structural and Civil Engineering》 SCIE EI 2010年第4期431-437,共7页
When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insu... When a historic façade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation,one needs to use interior thermal insulation systems.Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges.Yet they may be successfully used and,in many instances,are recommended as a complement to the exterior insulation.This paper presents one of these cases.It is focused on the most successful applications of capillary active,dynamic interior thermal insulation.This happens when such insulation is integrated with heating,cooling and ventilation,air conditioning(HVAC)system.Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations,we propose a next generation,namely,a bio-fiber thermal insulation.When completing the review,this paper proposes a concept of a joint research project to be undertaken by partners from the US(where improvement of indoor climate in exposed coastal areas is needed),China(indoor climate in non-air conditioned concrete buildings is an issue),and Germany(where the bio-fiber technology has been developed). 展开更多
关键词 capillary active insulation integrated heating cooling and ventilation air conditioning(HVAC)and building enclosure dynamic insulation switchable thermal resistance variable U-value walls
原文传递
基于多平台混合教学模式在通风空调工程课程中的应用探讨
18
作者 汝林 杨忠国 +1 位作者 郭胜杰 李栋 《科技资讯》 2024年第7期234-237,241,共5页
为提升通风空调工程课程教学效果,探讨了一种混合教学模式在通风空调工程课程中的应用。该模式融合翻转课堂与多平台构成。开展翻转课堂教学、建立基于互联网的“小范围”知识获取平台,以及研究生与本科生互动平台,三者融合以提升学生... 为提升通风空调工程课程教学效果,探讨了一种混合教学模式在通风空调工程课程中的应用。该模式融合翻转课堂与多平台构成。开展翻转课堂教学、建立基于互联网的“小范围”知识获取平台,以及研究生与本科生互动平台,三者融合以提升学生课程参与度,提高课程知识转化率,增强本科学生与土木水利专业学位硕士互动,完善课程教育体系。最终达到学生在通风空调工程领域的专业素养和实际应用能力逐步提高的目的,为通风空调工程课程的教学改革提供有效的经验。 展开更多
关键词 通风空调工程 混合式教学 翻转课堂 多沟通平台
下载PDF
核电通风空调系统故障检测与诊断
19
作者 宋园园 刘林顶 +1 位作者 吴明宇 宋德宽 《科技创新与应用》 2024年第2期156-159,共4页
通风空调系统为核电厂系统设备的稳定安全运行和人员安全操作提供可靠的保障,实现通风空调系统的稳定运行对核电厂房的平稳运行具有重要意义。该文针对核电厂通风空调系统的典型故障进行具体介绍,并综述现有通风空调系统故障检测诊断的... 通风空调系统为核电厂系统设备的稳定安全运行和人员安全操作提供可靠的保障,实现通风空调系统的稳定运行对核电厂房的平稳运行具有重要意义。该文针对核电厂通风空调系统的典型故障进行具体介绍,并综述现有通风空调系统故障检测诊断的具体方法、特点与不足,最后深入分析核电通风空调系统故障诊断未来的研究方向。 展开更多
关键词 核电 通风空调系统 故障检测 故障诊断 可靠性
下载PDF
市域车客室空调通风系统仿真与优化研究
20
作者 刘智远 孙伟 +2 位作者 易柯 曹小林 窦雨凡 《暖通空调》 2024年第7期147-151,33,共6页
以某市域车客室空调通风系统为研究对象,提出了将客室、送风系统、回风系统、废气排风系统和新风系统整体耦合的新仿真模型,使仿真边界条件设置贴合实际工程。利用ANSYS Fluent软件,对市域车空调通风系统的气流组织和传热状况进行了仿... 以某市域车客室空调通风系统为研究对象,提出了将客室、送风系统、回风系统、废气排风系统和新风系统整体耦合的新仿真模型,使仿真边界条件设置贴合实际工程。利用ANSYS Fluent软件,对市域车空调通风系统的气流组织和传热状况进行了仿真计算与优化。结果表明:优化前2台空调机组4个回风口的回风量分别为0.24、0.26、0.35、0.19 kg/s,回风量分布不均匀;废气排风道过于窄小,导致废气排风系统阻力高达629 Pa。鉴于此,对客室回风结构与废气排风结构进行了优化研究,优化后最大回风量与最小回风量仅相差0.05 kg/s,客室到废气排风出口流动阻力降低至120 Pa。客室内大部分区域温度范围为24~26℃,客室内部人员主要活动范围处于微风速,乘坐舒适性提升显著。本研究可以为市域车空调通风系统的优化设计提供依据。 展开更多
关键词 市域车 客室 空调通风系统 结构优化 气流组织 仿真分析
下载PDF
上一页 1 2 177 下一页 到第
使用帮助 返回顶部