期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Analysis and Modeling of the Central Air-Conditioning System in Intelligent Buildings 被引量:6
1
作者 郭巧 徐庆伟 《Journal of Beijing Institute of Technology》 EI CAS 2002年第3期295-297,共3页
The central air conditioning system in an intelligent building (IB) was analyzed and modeled in order to perform the optimization scheduling strategy of the central air conditioning system. A set of models proposed ... The central air conditioning system in an intelligent building (IB) was analyzed and modeled in order to perform the optimization scheduling strategy of the central air conditioning system. A set of models proposed and a type of periodically autoregressive model (PAR) based on the improved genetic algorithms (IGA) were used to perform the optimum energy saving scheduling. The example of the Liangmahe Plaza was taken to show the effectiveness of the methods. 展开更多
关键词 intelligent building analysis and modeling central air conditioning energy saving
下载PDF
Optimum Energy Management of the Central Air-Conditioning System in Intelligent Buildings
2
作者 郭巧 徐庆伟 《Journal of Beijing Institute of Technology》 EI CAS 2002年第3期298-301,共4页
An optimum energy saving scheduling strategy of the central air conditioning system in an intelligent building (IB) was proposed. Based on the system analysis a set of models of the central air conditioning system w... An optimum energy saving scheduling strategy of the central air conditioning system in an intelligent building (IB) was proposed. Based on the system analysis a set of models of the central air conditioning system was established. The periodically autoregressive models (PARM) based on genetic algorithms (GA) were used to predict the next day’s cold load. The improved genetic algorithms (IGA) with stochastic real number coding were used to finish the optimum energy saving scheduling of the system. The simulation results for the building of the Liangmahe Plaza show that the proposed strategy can save energy up to about 24 5%. 展开更多
关键词 intelligent building genetic algorithms central air conditioning energy saving
下载PDF
Design of Fuzzy Controller for Central Air Conditioner
3
作者 谢娟 耿庆波 《Journal of Beijing Institute of Technology》 EI CAS 2003年第S1期20-24,共5页
A structure of central air conditioning system in building and its running pattern are proposed in order to perform optimum energy saving strategy. The design of room temperature controller is taken as an example to d... A structure of central air conditioning system in building and its running pattern are proposed in order to perform optimum energy saving strategy. The design of room temperature controller is taken as an example to discuss the design of fuzzy controller using common microprogrammed control unit (MCU) in detail. Based on fuzzy theory the query control tables fixed in read only memory (ROM) of MCU are established to realize the energy saving in the room temperature controller and the reasoning procedure is analyzed. The diagram of hardware design and the flow chart of software of room temperature controller are presented. The results show that the proposed method is practical and effective to achieve the energy saving goal. 展开更多
关键词 central air conditioning system room temperature controller fuzzy control energy saving
下载PDF
MEASUREMENT TECHNOLOGY OF HEAT AND COOL
4
作者 朱春玲 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2001年第2期245-249,共5页
The popularization of large scale central air conditioning system (CACS) has brought forward a new pro blem,i.e. how to measure the cooling and heating quantum accurately. This problem will directly affect the qua ... The popularization of large scale central air conditioning system (CACS) has brought forward a new pro blem,i.e. how to measure the cooling and heating quantum accurately. This problem will directly affect the qua lity of modern property management. So the study on the technology of measuring heat and cool is very necessary. In this paper, the detailed thermal analysis and the mathematical model of relative parameters that affect the measurement of heat and cool are discussed. A sample instrument based on the model is made, After the trial use by several customers, the device is proved to be practical, worthwhile and of good capacity. 展开更多
关键词 central air conditioning measurement data acquisition single chip
下载PDF
Strategy of constructing virtual peaking unit by public buildings’central air conditioning loads for day-ahead power dispatching 被引量:7
5
作者 Chenxing YANG Qingshan XU Xufang WANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第2期187-201,共15页
With the gradually widely usage of the air conditioning(AC) loads in developing countries, the urban power grid load has swiftly increased over the past decade.Especially in China, the AC load has accounted for over30... With the gradually widely usage of the air conditioning(AC) loads in developing countries, the urban power grid load has swiftly increased over the past decade.Especially in China, the AC load has accounted for over30% of the maximum load in many cities during summer.This paper proposes a scheme of constructing a virtual peaking unit(VPU) by public buildings’ cool storage central AC(CSCAC) systems and non-CSCAC(NCSCAC)systems for the day-ahead power network dispatching(DAPND). Considering the accumulation effect of different meteorological parameters, a short term load forecasting method of public building’s central AC(CAC) baseline load is firstly discussed. Then, a second-order equivalent thermal parameters model is established for the public building’s CAC load. Moreover, the novel load reduction control strategies for the public building’s CSCAC system and the public building’s NCSCAC system are respectively presented. Furthermore, based on the multiple-rank control strategy, the model of the DAPND with the participation of a VPU is set up. The VPU is composed of large-scale regulated public building’s CAC loads. To demonstrate the effectiveness of the proposed strategy, results of a sample study on a region in Nanjing which involves 22 public buildings’ CAC loads are described in this paper. Simulated results show that, by adopting the proposed DAPND scheme, the power network peak load in the region obviously decreases with a small enough deviation between the regulated load value and the dispatching instruction of the VPU. The total electricity-saving amount accounts for7.78% of total electricity consumption of the VPU before regulation. 展开更多
关键词 Central air conditioning Peak load shedding Day-ahead power network dispatching Virtual peaking unit Schedulable capacity
原文传递
Prevalence and risk factors of dry eye disease in young and middle-aged office employee:a Xi’an Study 被引量:5
6
作者 Jing-Wen Hu Xiu-Ping Zhu +2 位作者 Shi-Yin Pan Hua Yang Xiang-Hua Xiao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第4期567-573,共7页
AIM:To estimate the prevalence of and risk factors for dry eye disease(DED)in young and middle-aged office employee in Xi’an.METHODS:This cross-sectional study of the prevalence of and risk factors for DED investigat... AIM:To estimate the prevalence of and risk factors for dry eye disease(DED)in young and middle-aged office employee in Xi’an.METHODS:This cross-sectional study of the prevalence of and risk factors for DED investigated 486 young and middle-aged Chinese office employee in Xi’an.DED symptoms and potential risk factors were assessed using the ocular surface disease index combined with a risk factors questionnaire,and tear function was evaluated using the tear film break-up time and Schirmer’s test.Possible risk factors for DED were estimated by binary Logistic regression analysis.RESULTS:DED was diagnosed in 100 females and 96 males,giving a prevalence of 40.3%[95%confidence interval(CI)=36.0%-44.7%].The multivariate binary Logistic regression model indicated that the possible risk factors for DED were being female(OR=1.592,95%CI=1.034-2.451,P=0.035),being aged≥40 y(OR=1.593,95%CI=1.034-2.454,P=0.035),using a VDT daily for>6 h(OR=1.990,95%CI=1.334-2.971,P=0.001),the presence of central air conditioning(OR=1.548,95%CI=1.053-2.276,P=0.026),and self-reported dryness of the mouth and nose(OR=1.589,95%CI=1.071-2.357,P=0.021).CONCLUSION:There is a high prevalence of clinically diagnosed DED in young and middle-aged video displayterminal(VDT)users.Interventions against the modifiable risk factors should be taken to prevent the occurrence and development of DED in this population. 展开更多
关键词 dry eye disease PREVALENCE office employee video display terminal central air conditioning age FEMALE
下载PDF