An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature con...An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy.展开更多
Continental reconstructions in Central Asia are represented by orogenesis along some large orogenic belts in the Altaid collage (Fig. 1 ) or Central Asian Orogenic Belt (CAOB), which separate the East European and...Continental reconstructions in Central Asia are represented by orogenesis along some large orogenic belts in the Altaid collage (Fig. 1 ) or Central Asian Orogenic Belt (CAOB), which separate the East European and Siberian cratons to the north from the Tarim and North China cratons to the south ($eng0r et al,, 1993; Jahn et al., 2004; Windley et al., 2007; Qu et al., 2008; Xiao et al., 2010; Xiao and Santosh, 2014). The Altaid Collage was characterized by complex long tectonic and structural evolution from at least ca. 1.0 Ga to late Paleozoic-early Mesozoic with considerable continental growth (Khain et al., 2002; Jahn et al., 2004; Xiao et al., 2009, 2014; KrOner et al., 2014), followed by Cenozoic intracontinental evolution related to far-field effect of the collision of the In- dian Plate to the Eurasian Accompanying with these complex world-class ore deposits developed 2001; Goldfarb et al., 2003, 2014). Plate (Cunningham, 2005). geodynamic evolutions, many (Qin, 2000; Yakubchuk et al,2001; Goldfarb et al., 2003, 2014).展开更多
Central air-conditioning systems predominantly operate under partial load conditions.The optimization of a differential pressure setpoint in the chilled water system of a central air-conditioning system leads to a mor...Central air-conditioning systems predominantly operate under partial load conditions.The optimization of a differential pressure setpoint in the chilled water system of a central air-conditioning system leads to a more energy-efficient operation.Determining the differential pressure adjustment value based on the terminal user's real-time demand is one of the critical issues to be addressed during the optimal control process.Furthermore,the online application of the differential pressure setpoint optimization method needs to be considered,along with the stability of the system.This paper proposes a variable differential pressure reset method with an adaptive adjustment algorithm based on the Mamdani fuzzy model.The proposed method was compared with differential pressure reset methods with reference to the chilled water differential temperature,outdoor temperature,and linear model based on the adjustment algorithm.The energy-saving potential,temperature control effect,and avoidance of the most unfavorable thermodynamic loop effects of the four methods were investigated experimentally.The results indicated that,while satisfying the terminal user's energy supply demand and ensuring the avoidance of the most unfavorable thermodynamic loop,the proposed adaptive adjustment algorithm also decreased the differential pressure setpoint value by 25.1%—59.1%and achieved energy savings of 10.6%-45.0%.By monitoring the valve position and supply air temperature of each terminal user,the proposed method exhibited suitable online adaptability and could be flexibly applied to buildings with random load changes.展开更多
文摘An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy.
基金financially supported by the Natural National Science Foundation of China(Grant Nos.41230207,41202150, 41472192,41390441 and 41190075)
文摘Continental reconstructions in Central Asia are represented by orogenesis along some large orogenic belts in the Altaid collage (Fig. 1 ) or Central Asian Orogenic Belt (CAOB), which separate the East European and Siberian cratons to the north from the Tarim and North China cratons to the south ($eng0r et al,, 1993; Jahn et al., 2004; Windley et al., 2007; Qu et al., 2008; Xiao et al., 2010; Xiao and Santosh, 2014). The Altaid Collage was characterized by complex long tectonic and structural evolution from at least ca. 1.0 Ga to late Paleozoic-early Mesozoic with considerable continental growth (Khain et al., 2002; Jahn et al., 2004; Xiao et al., 2009, 2014; KrOner et al., 2014), followed by Cenozoic intracontinental evolution related to far-field effect of the collision of the In- dian Plate to the Eurasian Accompanying with these complex world-class ore deposits developed 2001; Goldfarb et al., 2003, 2014). Plate (Cunningham, 2005). geodynamic evolutions, many (Qin, 2000; Yakubchuk et al,2001; Goldfarb et al., 2003, 2014).
基金support provided by the National Key Research and Development Project of China(No.2017YFC0704100,under the title New Generation Intelligent Building Platform Techniques)Liaoning Natural Science Foundation Guidance Plan(No.20180551057)+1 种基金Dalian High-level Talent Innovation Support Program(Youth Technology Star)(No.2017RQ099)Fundamental Research Funds for the Central Universities(No.DUT20JC47)。
文摘Central air-conditioning systems predominantly operate under partial load conditions.The optimization of a differential pressure setpoint in the chilled water system of a central air-conditioning system leads to a more energy-efficient operation.Determining the differential pressure adjustment value based on the terminal user's real-time demand is one of the critical issues to be addressed during the optimal control process.Furthermore,the online application of the differential pressure setpoint optimization method needs to be considered,along with the stability of the system.This paper proposes a variable differential pressure reset method with an adaptive adjustment algorithm based on the Mamdani fuzzy model.The proposed method was compared with differential pressure reset methods with reference to the chilled water differential temperature,outdoor temperature,and linear model based on the adjustment algorithm.The energy-saving potential,temperature control effect,and avoidance of the most unfavorable thermodynamic loop effects of the four methods were investigated experimentally.The results indicated that,while satisfying the terminal user's energy supply demand and ensuring the avoidance of the most unfavorable thermodynamic loop,the proposed adaptive adjustment algorithm also decreased the differential pressure setpoint value by 25.1%—59.1%and achieved energy savings of 10.6%-45.0%.By monitoring the valve position and supply air temperature of each terminal user,the proposed method exhibited suitable online adaptability and could be flexibly applied to buildings with random load changes.