In order to evaluate the applicability of the organic polymeric flocculants(OPF) in the treatment of oil refinery sludge, experiments were conducted to show that OPF have better performance of flocculation than inorga...In order to evaluate the applicability of the organic polymeric flocculants(OPF) in the treatment of oil refinery sludge, experiments were conducted to show that OPF have better performance of flocculation than inorganic flocculants. Both the anionic and cationic OPF have satisfactory flocculation efficiency in oil sludge treatment, but the latter are more cost efficient. Among the over 20 types of flocculants tested, 2 OPF(CPAM 2 and HPAM 2) were selected as the treatment agents, based on their good treatment performances, oil resistance and economic feasibility. It was demonstrated in the industrial scale centrifugal dewatering experiments that the application of either CPAM 2 or HPAM 2 could achieve high treatment efficiency of the oil sludge dewatering and reduce the COD of centrifugal liquid to less than 1000 mg/L.展开更多
Two new spectroscopic methods to detect the optical activity of liquid-liquid interfaces have been developed. The first one is the centrifugal liquid membrane (CLM) method combined with a conventional circular dichr...Two new spectroscopic methods to detect the optical activity of liquid-liquid interfaces have been developed. The first one is the centrifugal liquid membrane (CLM) method combined with a conventional circular dichroism (CD) spectropolarimetry and the second one is a more interfacial specific second harmonic generation CD (SHG-CD) spectrometry. In the CLM-CD method, a cylindrical glass cell containing small amounts of organic and aqueous phases was rotated at about 7000 r/min in a sample chamber of a CD spectropolarimeter to generate an interface with a high specific interfacial area between the two-phase liquid membranes. The CD spectra of the J-aggregate of protonated 5,10,15, 20-tetraphenylporphyrin formed at the toluene-sulfuric acid interface have been measured, As for the SHG-CD, a circularly polarized wavelength-variable fs-laser system was constructed to measure the interfacial SHG spectra of a flat liquid-liquid interface. The ion-associated aggregation of a water-soluble anionic porphyrin promoted with a cationic amphiphile at the heptane-water interface was observed by this technique and the observed SHG-CD spectra proved the generation of a characteristic oPtical activity accompanied by the formation of the interfacial aggregate of inherently achiral porphyrin molecules. These methods will pioneer a new field of interfacial chiral chemistry in the studies of solvent extraction mechanisms.展开更多
文摘In order to evaluate the applicability of the organic polymeric flocculants(OPF) in the treatment of oil refinery sludge, experiments were conducted to show that OPF have better performance of flocculation than inorganic flocculants. Both the anionic and cationic OPF have satisfactory flocculation efficiency in oil sludge treatment, but the latter are more cost efficient. Among the over 20 types of flocculants tested, 2 OPF(CPAM 2 and HPAM 2) were selected as the treatment agents, based on their good treatment performances, oil resistance and economic feasibility. It was demonstrated in the industrial scale centrifugal dewatering experiments that the application of either CPAM 2 or HPAM 2 could achieve high treatment efficiency of the oil sludge dewatering and reduce the COD of centrifugal liquid to less than 1000 mg/L.
基金Supported by the Grant-in-Aid for Scientific Research (No. 16105002) from the Ministry of Education, Science, Sports, and Culture, Japan
文摘Two new spectroscopic methods to detect the optical activity of liquid-liquid interfaces have been developed. The first one is the centrifugal liquid membrane (CLM) method combined with a conventional circular dichroism (CD) spectropolarimetry and the second one is a more interfacial specific second harmonic generation CD (SHG-CD) spectrometry. In the CLM-CD method, a cylindrical glass cell containing small amounts of organic and aqueous phases was rotated at about 7000 r/min in a sample chamber of a CD spectropolarimeter to generate an interface with a high specific interfacial area between the two-phase liquid membranes. The CD spectra of the J-aggregate of protonated 5,10,15, 20-tetraphenylporphyrin formed at the toluene-sulfuric acid interface have been measured, As for the SHG-CD, a circularly polarized wavelength-variable fs-laser system was constructed to measure the interfacial SHG spectra of a flat liquid-liquid interface. The ion-associated aggregation of a water-soluble anionic porphyrin promoted with a cationic amphiphile at the heptane-water interface was observed by this technique and the observed SHG-CD spectra proved the generation of a characteristic oPtical activity accompanied by the formation of the interfacial aggregate of inherently achiral porphyrin molecules. These methods will pioneer a new field of interfacial chiral chemistry in the studies of solvent extraction mechanisms.