The instantaneous variations of the hydraulic characteristics take place in centrifugal pumps during their start-up,shutdown and other variable speed operations.In this paper,the variable speed method was proposed to ...The instantaneous variations of the hydraulic characteristics take place in centrifugal pumps during their start-up,shutdown and other variable speed operations.In this paper,the variable speed method was proposed to simulate the transient internal flow field and the external performance of the pump during starting and stopping periods.The terms of accelerations due to variable speeds in the flow governing equations were analyzed in a multiple reference of frame(MRF).A transient CFD simulation was performed for a typical centrifugal pump by using ANSYS-CFX with the standard k-εturbulence model.The entire simulation process was composed of four stages:start-up,normal run,shutdown and post-shutdown.The function of rotating speed with regard to time was set by CEL language directly into the impeller domain in the pre-processor of the software to conduct variable speed simulation.The variations of the flow field in the centrifugal pump were obtained from the transient simulation.The changing laws of flow rate,head and other performance parameters over time were also analyzed and summarized.展开更多
The main structural parameters of the IR100-80-100A type chemical centrifugal pump have been optimized by means of an orthogonal test approach.The centrifugal pump has been modeled using the CFturbo software,and 16 se...The main structural parameters of the IR100-80-100A type chemical centrifugal pump have been optimized by means of an orthogonal test approach.The centrifugal pump has been modeled using the CFturbo software,and 16 sets of orthogonal-test schemes have been defined on the basis of 4 parameters,namely,the blade number,blade outlet angle,impeller outlet diameter,and impeller outlet width.Such analysis has been used to determine the influence of each index parameter on the pump working efficiency and identify a set of optimal combinations of such parameters.The internalflowfield in the centrifugal pump has been simulated by using the PumLinx software.These numerical results have shown that,compared with the prototype pump,the outlet pressure and shaft power of the optimized pump can be significantly reduced,and the pump working efficiency can be improved by 5.59%.In the present study,some arguments are also provided to demonstrate that,with respect to other optimization methods,the orthogonal test approach is more convenient,and requires less test times.展开更多
文摘The instantaneous variations of the hydraulic characteristics take place in centrifugal pumps during their start-up,shutdown and other variable speed operations.In this paper,the variable speed method was proposed to simulate the transient internal flow field and the external performance of the pump during starting and stopping periods.The terms of accelerations due to variable speeds in the flow governing equations were analyzed in a multiple reference of frame(MRF).A transient CFD simulation was performed for a typical centrifugal pump by using ANSYS-CFX with the standard k-εturbulence model.The entire simulation process was composed of four stages:start-up,normal run,shutdown and post-shutdown.The function of rotating speed with regard to time was set by CEL language directly into the impeller domain in the pre-processor of the software to conduct variable speed simulation.The variations of the flow field in the centrifugal pump were obtained from the transient simulation.The changing laws of flow rate,head and other performance parameters over time were also analyzed and summarized.
基金supported by the Anhui Province University Discipline(Professional)Top Talent Academic Funding Project(No.gxbjZD2021076)This project is supported by the Key Project of Natural Science Research in Colleges and Universities of Anhui Province(No.KJ2021A1026)This project is supported by the Key Project of Natural Science Foundation of Chaohu University(No.XLZ-201902).
文摘The main structural parameters of the IR100-80-100A type chemical centrifugal pump have been optimized by means of an orthogonal test approach.The centrifugal pump has been modeled using the CFturbo software,and 16 sets of orthogonal-test schemes have been defined on the basis of 4 parameters,namely,the blade number,blade outlet angle,impeller outlet diameter,and impeller outlet width.Such analysis has been used to determine the influence of each index parameter on the pump working efficiency and identify a set of optimal combinations of such parameters.The internalflowfield in the centrifugal pump has been simulated by using the PumLinx software.These numerical results have shown that,compared with the prototype pump,the outlet pressure and shaft power of the optimized pump can be significantly reduced,and the pump working efficiency can be improved by 5.59%.In the present study,some arguments are also provided to demonstrate that,with respect to other optimization methods,the orthogonal test approach is more convenient,and requires less test times.