With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle,...With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.展开更多
If the measuring signals were input to the chaotic dynamic system as initial parameters, the system outputs might be in steady state, periodic state or chaos state. If the chaotic dynamic system outputs controlled in ...If the measuring signals were input to the chaotic dynamic system as initial parameters, the system outputs might be in steady state, periodic state or chaos state. If the chaotic dynamic system outputs controlled in the periodic states, the periodic numbers would be changed most with the signals. Our novel method is to add chaotic dynamic vibration to the measurement or sensor system.The sensor sensitivity and precision of a measurement system would be improved with this method. Chaotic dynamics measurement algorithms are given and their sensitivity to parameters are analyzed in this paper. The effects of noises on the system are discussed.展开更多
文摘With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.
文摘If the measuring signals were input to the chaotic dynamic system as initial parameters, the system outputs might be in steady state, periodic state or chaos state. If the chaotic dynamic system outputs controlled in the periodic states, the periodic numbers would be changed most with the signals. Our novel method is to add chaotic dynamic vibration to the measurement or sensor system.The sensor sensitivity and precision of a measurement system would be improved with this method. Chaotic dynamics measurement algorithms are given and their sensitivity to parameters are analyzed in this paper. The effects of noises on the system are discussed.
文摘目的孤立性肺结节(solitary pulmonary nodule,SPN)的定性诊断十分困难,PET/CT是目前评价良、恶性病变最具优势的影像学手段之一。文中用Meta分析方法综合评价18F-脱氧葡萄糖(18Fluorodexglucose,FDG)PET/CT显像诊断恶性孤立性肺结节的价值。方法以孤立性肺结节、FDG、PET/CT等为检索词,检索1994年1月至2009年7月的Medline数据库、西文生物医学期刊文献服务系统、外文生物医学期刊全文数据库、中国学术期刊网全文数据库等相关中英文文献。对符合标准的研究进行质量评估,用MetaDisc1.4软件进行异质性检验,综合敏感性、特异性和诊断优势比,绘制汇总受试者工作特征(summary receiver operating characteristic,SROC)曲线和计算曲线下面积(the area under the curve,AUC),并进行敏感性分析。结果共检索相关文献29篇,其中11篇符合标准纳入分析,A级1篇,B级10篇,各研究之间存在异质性,按照随机效应模型合并敏感性、特异性、诊断优势比(diagnostic odds ratio,DOR)及其95%可信区间分别为91%(87%~93%)、83%(78%~87%)和51.04(23.33~111.66),AUC为0.9383,Q值为0.875 3,纳入文献稳定性较好。结论 18F-FDG PET/CT显像能灵敏、准确地诊断恶性孤立性肺结节,具有较高的临床应用价值。