期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Charge noise acting on graphene double quantum dots in circuit quantum electrodynamics architecture
1
作者 李炎 李舒啸 +4 位作者 李海欧 邓光伟 曹刚 肖明 郭国平 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期152-157,共6页
We investigate the dephasing mechanisms induced by the charge noise and microwave heating effect acting on a graphene double quantum dot (DQD) capacitively coupled to a microwave resonator. The charge noise is obtai... We investigate the dephasing mechanisms induced by the charge noise and microwave heating effect acting on a graphene double quantum dot (DQD) capacitively coupled to a microwave resonator. The charge noise is obtained from DC transport current, and its contribution to dephasing is simultaneously determined by the amplitude response of the microwave resonator. A lowfrequency 1/f-type noise is demonstrated to be the dominant factor of the dephasing of graphene DQD. Furthermore, when the applied microwave power is larger than -90 dBm, the dephasing rate of graphene DQD increases rapidly with the increase of microwave power, and fluctuates slightly with the applied microwave power smaller than -90 dBm. Our results can be applied to suppress the impeditive influence on the dephasing of graphene-based devices associated with microwave input in the perspective investigations. 展开更多
关键词 quantum dot microwave resonator charge noise GRAPHENE
下载PDF
Neutron yield measurement system of HL-2A tokamak
2
作者 袁国梁 温左蔚 +2 位作者 魏凌峰 张进文 杨青巍 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第6期38-44,共7页
This research presents the development of HL-2A neutron yield measurement which includes^(235)U fission chamber and BF_(3)and^(3)He proportional counters.Equivalent noise formula of the radiation detection signal ampl... This research presents the development of HL-2A neutron yield measurement which includes^(235)U fission chamber and BF_(3)and^(3)He proportional counters.Equivalent noise formula of the radiation detection signal amplification system was derived to guide the development of the signal amplification system.Then all detectors were calibrated in situ by using the^(252)C_(f)neutron source.The neutron yield of the HL-2A during neutral beam heating was analyzed.These results indicate that the developed neutron flux diagnostic system can obtain neutron yield results under various experimental conditions of the HL-2A tokamak,and can provide information on neutron yield. 展开更多
关键词 HL-2A neutron yield neutron flux fission chamber in situ calibration equivalent noise charge
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部