Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the comp...Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the complete sources of CCD noise, we study the effects of TDI operation mode on noise, and the relationship between different types of noise and number of the TDI stage. Then we propose a new technique to identify and measure sources of TDI CCD noise employing mathematical statistics theory, where theoretical analysis shows that noise estimated formulation converges well. Finally, we establish a testing platform to carry out experiments, and a standard TDI CCD is calibrated by using the proposed method. The experimental results show that the noise analysis and measurement methods presented in this paper are useful for modeling TDI CCDs.展开更多
<div style="text-align:justify;"> In this study, a two-dimensional model describing thermal stress on a charge-coupled device (CCD) induced by ms laser pulses was examined. Considering the nonlinearity...<div style="text-align:justify;"> In this study, a two-dimensional model describing thermal stress on a charge-coupled device (CCD) induced by ms laser pulses was examined. Considering the nonlinearity of the CCD’s material parameters and the melting phase transition process of aluminum electrode materials was considered by using equivalent specific heat capacity method, the physical process where a laser pulse irradiating a CCD pixel array was simulated using COMSOL Multiphysics software. The temperature field and thermal stress field were calculated and analyzed. In order to clarify the mechanism producing damage on the CCD detector, Raman spectra from silicon were measured with a micro-Raman spectrometer to determine stress change in the CCD chip. The procedure presented herein illustrates a method for evaluating strain in a CCD after laser irradiation. </div>展开更多
An experimental method to study the influence of surface contamination of a thinned, backside illuminated charge-coupled device(CCD) upon its quantum efficiency in soft X-ray region is suggested. A transmission gratin...An experimental method to study the influence of surface contamination of a thinned, backside illuminated charge-coupled device(CCD) upon its quantum efficiency in soft X-ray region is suggested. A transmission grating spectrometer(TGS), in which the transmission grating is coupled to a thinned, backside illuminated charge coupled device, is used to measure the continuum X-ray emission from the end of cylindrical target irradiated by laser. In the measured spectra, only the carbon K absorption edge at wavelength of 4.4 um due to condensation of the vacuum oil oil the CCD surface is clearly seen. The surface contamination is considered as an effective "carbon filter" and the filter absorption to correct the quantum efficiency of the CCD camera is taken into account. The effective thickness of the carbon filter is determined by comparing the jump height of the measured spectra at 4.4um with those of the carbon absorption coefficient curves obtained from various carbon thickness. The accuracy of this method is tested by comparing the X-ray spectrum measured by the TGS with that obtained by a soft X-ray spectrometer.展开更多
基金Project supported by the National High Technology Research and Development Program of China (Grant No. 2006AA06A208)
文摘Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the complete sources of CCD noise, we study the effects of TDI operation mode on noise, and the relationship between different types of noise and number of the TDI stage. Then we propose a new technique to identify and measure sources of TDI CCD noise employing mathematical statistics theory, where theoretical analysis shows that noise estimated formulation converges well. Finally, we establish a testing platform to carry out experiments, and a standard TDI CCD is calibrated by using the proposed method. The experimental results show that the noise analysis and measurement methods presented in this paper are useful for modeling TDI CCDs.
文摘<div style="text-align:justify;"> In this study, a two-dimensional model describing thermal stress on a charge-coupled device (CCD) induced by ms laser pulses was examined. Considering the nonlinearity of the CCD’s material parameters and the melting phase transition process of aluminum electrode materials was considered by using equivalent specific heat capacity method, the physical process where a laser pulse irradiating a CCD pixel array was simulated using COMSOL Multiphysics software. The temperature field and thermal stress field were calculated and analyzed. In order to clarify the mechanism producing damage on the CCD detector, Raman spectra from silicon were measured with a micro-Raman spectrometer to determine stress change in the CCD chip. The procedure presented herein illustrates a method for evaluating strain in a CCD after laser irradiation. </div>
基金the National High-Technolog Project (No. 863-416-3)
文摘An experimental method to study the influence of surface contamination of a thinned, backside illuminated charge-coupled device(CCD) upon its quantum efficiency in soft X-ray region is suggested. A transmission grating spectrometer(TGS), in which the transmission grating is coupled to a thinned, backside illuminated charge coupled device, is used to measure the continuum X-ray emission from the end of cylindrical target irradiated by laser. In the measured spectra, only the carbon K absorption edge at wavelength of 4.4 um due to condensation of the vacuum oil oil the CCD surface is clearly seen. The surface contamination is considered as an effective "carbon filter" and the filter absorption to correct the quantum efficiency of the CCD camera is taken into account. The effective thickness of the carbon filter is determined by comparing the jump height of the measured spectra at 4.4um with those of the carbon absorption coefficient curves obtained from various carbon thickness. The accuracy of this method is tested by comparing the X-ray spectrum measured by the TGS with that obtained by a soft X-ray spectrometer.