期刊文献+
共找到30篇文章
< 1 2 >
每页显示 20 50 100
Ultraconformable Integrated Wireless Charging Micro-Supercapacitor Skin
1
作者 Chang Gao Qing You +5 位作者 Jiancheng Huang Jingye Sun Xuan Yao Mingqiang Zhu Yang Zhao Tao Deng 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第7期46-58,共13页
Conformable and wire-less charging energy storage devices play important roles in enabling the fast development of wearable,non-contact soft electronics.However,current wire-less charging power sources are still restr... Conformable and wire-less charging energy storage devices play important roles in enabling the fast development of wearable,non-contact soft electronics.However,current wire-less charging power sources are still restricted by limited flexural angles and fragile connection of components,resulting in the failure expression of performance and constraining their fur-ther applications in health monitoring wearables and moveable artificial limbs.Herein,we present an ultracompatible skin-like integrated wireless charging micro-supercapacitor,which building blocks(including electrolyte,electrode and substrate)are all evaporated by liquid precursor.Owing to the infiltration and permeation of the liquid,each part of the integrated device attached firmly with each other,forming a compact and all-in-one configuration.In addition,benefitting from the controllable volume of electrode solution precursor,the electrode thickness is easily regulated varying from 11.7 to 112.5μm.This prepared thin IWC-MSC skin can fit well with curving human body,and could be wireless charged to store electricity into high capacitive micro-supercapacitors(11.39 F cm-3)of the integrated device.We believe this work will shed light on the construction of skin-attachable electronics and irregular sensing microrobots. 展开更多
关键词 Micro-supercapacitor Electronic skin Supercapacitor skin Wireless charging energy storage device
下载PDF
Noise analysis and measurement of time delay and integration charge coupled device 被引量:4
2
作者 王德江 张涛 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第8期348-353,共6页
Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the comp... Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the complete sources of CCD noise, we study the effects of TDI operation mode on noise, and the relationship between different types of noise and number of the TDI stage. Then we propose a new technique to identify and measure sources of TDI CCD noise employing mathematical statistics theory, where theoretical analysis shows that noise estimated formulation converges well. Finally, we establish a testing platform to carry out experiments, and a standard TDI CCD is calibrated by using the proposed method. The experimental results show that the noise analysis and measurement methods presented in this paper are useful for modeling TDI CCDs. 展开更多
关键词 time delay and integration charge coupled device noise measurement remote sensingapplication
下载PDF
Charge Couple Device-Based Systemfor3-di mensional Real Ti me Positioning on the Assessment of Segmental Range of Motion of Lumbar Spine 被引量:1
3
作者 赵平 陈立君 +3 位作者 管晶 潘丽 丁辉 丁海署 《Chinese Journal of Integrated Traditional and Western Medicine》 2005年第4期272-278,共7页
Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze it... Objective: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze its clinical significance. Methods: Seven patients with lumbar joint dysfunction and 8 healthy subjects were tested twice by the CCD-based system with an interval of 10 min. Results: The ROM of the patients was obviously lesser than that of the healthy subjects. The measuring data of segmental ROM of lumbar spine by CCD system is correlated significantly to the same data checked later on the same subjects in every direction of the movements. The differences between two checks are usually less than 1 degree. Conclusion: Specially designed CCD based system for 3-dimensional real-time positioning could objectively reflect the segmental ROM of lumbar spine. The system would be of great clinical significance in the assessment of the biomechanical dysfunction of lumbar spine and the effect of the treatment applied. 展开更多
关键词 charge couple device camera lumbar spine RADIOLOGY segmental range of motion
下载PDF
Electrical bistable devices using composites of zinc sulfide nanoparticles and poly-(N-vinylcarbazole) 被引量:2
4
作者 曹亚鹏 胡煜峰 +8 位作者 李剑焘 叶海航 吕龙锋 宁宇 鲁启鹏 唐爱伟 娄志东 侯延冰 滕枫 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第3期298-301,共4页
N-dodecanethiol capped zinc sulfide(Zn S) nanocrystals were synthesized by the one-pot approach and blended with poly(N-vinylcarbazole)(PVK) to fabricate electrical bistable devices. The corresponding devices di... N-dodecanethiol capped zinc sulfide(Zn S) nanocrystals were synthesized by the one-pot approach and blended with poly(N-vinylcarbazole)(PVK) to fabricate electrical bistable devices. The corresponding devices did exhibit electrical bistability and negative differential resistance(NDR) effects. A large ON/OFF current ratio of 104 at negative voltages was obtained by applying different amplitudes of sweeping voltage. The observed conductance switching and the negative differential resistance are attributed to the electric-field-induced charge transfer between the nanocrystals and the polymer,and the charge trapping/detrapping in the nanocrystals. 展开更多
关键词 electrical bistable devices ON/OFF current ratio electric-field-induced charge transfer trapping/detrapping
下载PDF
An Automatic System of Vehicle Number-Plate Recognition Based on Neural Networks 被引量:2
5
作者 Wei Wu Dept. of Road and Traffic Engineering, Changsha Communications University, 410076, P. R. China Huang Xinhan, Wang Min & Song Yexin Dept. of Control Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, P. R. China 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2001年第2期63-72,共10页
This paper presents an automatic system of vehicle number-plate recognition based on neural networks. In this system, location of number-plate and recognition of characters in number-plate can be automatically complet... This paper presents an automatic system of vehicle number-plate recognition based on neural networks. In this system, location of number-plate and recognition of characters in number-plate can be automatically completed. Pixel colors of Number-plate area are classified using neural network, then color features are extracted by analyzing scanning lines of the cross-section of number-plate. It takes full use of number-plate color features to locate number-plate. Characters in number-plate can be effectively recognized using the neural networks. Experimental results show that the correct rate of number-plate location is close to 100%, and the time of number-plate location is less than 1 second. Moreover, recognition rate of characters is improved due to the known number-plate type. It is also observed that this system is not sensitive to variations of weather, illumination and vehicle speed. In addition, and also the size of number-plate need not to be known in prior. This system is of crucial significance to apply and spread the automatic system of vehicle number-plate recognition. 展开更多
关键词 Cameras Charge coupled devices Feature extraction Neural networks VEHICLES
下载PDF
Surface diffuse discharge mechanism of well-aligned atmospheric pressure microplasma arrays 被引量:1
6
作者 周仁武 周儒森 +6 位作者 庄金星 李江炜 陈茂冬 张先徽 刘东平 Kostya (Ken) Ostrikov 杨思泽 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第4期222-230,共9页
A stable and homogeneous well-aligned air microplasma device for application at atmospheric pressure is designed and its electrical and optical characteristics are investigated. Current-voltage measurements and intens... A stable and homogeneous well-aligned air microplasma device for application at atmospheric pressure is designed and its electrical and optical characteristics are investigated. Current-voltage measurements and intensified charge coupled device (ICCD) images show that the well-aligned air microplasma device is able to generate a large-area and homogeneous discharge at the applied voltages ranging from 12 kV to 14 kV, with a repetition frequency of 5 kHz, which is attributed to the diffusion effect of plasma on dielectric surface. Moreover, this well-aligned microplasma device may result in the uniform and large-area surface modification of heat-sensitive PET polymers without damage, such as optimization in hydrophobicity and biocompatibility. In the biomedical field, the utility of this well-aligned microplasma device is further testified. It proves to be very efficient for the large-area and uniform inactivation of E. coli cells with a density of 103/cm2 on LB agar plate culture medium, and inactivation efficiency can reach up to 99% for 2-min treatment. 展开更多
关键词 surface diffusion intensified charge coupled device surface modification bacterial inactivation
下载PDF
Experimental Investigation of Wave Heights in A Directional Wave Field Through Image Sequences
7
作者 Chung-Ren CHOU Teng-Wei LIN +1 位作者 Ruey-Syan SHIH John Z. YIMa 《China Ocean Engineering》 SCIE EI 2005年第1期37-48,共12页
Measurements of wave heights with image sequences from a Charged Coupled Device(CCD) camera were made. Sinusoidal, as well as unidirectional and directional, waves were used for the experiments. A transfer function wa... Measurements of wave heights with image sequences from a Charged Coupled Device(CCD) camera were made. Sinusoidal, as well as unidirectional and directional, waves were used for the experiments. A transfer function was obtained by calibration of the magnitudes of the gray values of the images against the results of wave gauge measurements for directional waves. With this transfer function, wave heights for regular waves were deduced. It is shown that the average relative errors are smaller than 16% for both unidirectional and directional waves. 展开更多
关键词 charged coupled device remote sensing directional wave transfer function wave height measurements
下载PDF
Design and implementation of high speed TDI CCD timing-driven circuits
8
作者 李波 徐正平 +2 位作者 李军 黄厚田 王德江 《Journal of Measurement Science and Instrumentation》 CAS 2012年第2期185-190,共6页
The time delay integration charge coupled device(TDI CCD)is the key component in remote sensing systems.The paper analyzes the structure and the working principles of the device according to a customized TDI CCD chip.... The time delay integration charge coupled device(TDI CCD)is the key component in remote sensing systems.The paper analyzes the structure and the working principles of the device according to a customized TDI CCD chip.Employing the special clock resources and large-scale phase locked logic(PLL)in field-programmable gate arrays(FPGA),a timing-driven approach is proposed,using which all timing signals including reset gate,horizontal and vertical timing signals,are implemented in one chip.This not only reduces printed circuit board(PCB)space,but also enhances the portability of the system.By studying and calculating CCD parameters thoroughly,load capacity and power consumption,package,etc,are compared between various candidates chips,and detailed comparison results are also listed in table.Experimental results show that clock generator and driving circuit satisfy the requirements of high speed TDI CCD. 展开更多
关键词 time delay integration charge coupled device(TDI CCD) timing-driven circuit field-programmable gate arrays(FPGA)
下载PDF
Characteristics of the CsI:Tl Scintillator Crystal for X-Ray Imaging Applications
9
作者 Maria da Conceicao Costa Pereira Tufic Madi Filho +1 位作者 Jose Roberto Berretta Carlos Henrique de Mesquita 《Materials Sciences and Applications》 2018年第2期268-280,共13页
Scintillators are high-density luminescent materials that convert X-rays to visible light. Thallium doped cesium iodide (CsI:Tl) scintillation materials are widely used as converters for X-rays into visible light, wit... Scintillators are high-density luminescent materials that convert X-rays to visible light. Thallium doped cesium iodide (CsI:Tl) scintillation materials are widely used as converters for X-rays into visible light, with very high conversion efficiency of 64.000 optical photons/MeV. CsI:Tl crystals are commercially available, but, the possibility of developing these crystals into different geometric shapes, meeting the need for coupling the photosensor and reducing cost, makes this material very attractive for scientific research. The objective of this work was to study the feasibility of using radiation sensors, scintillators type, developed for use in imaging systems for X-rays. In this paper, the CsI:Tl scintillator crystal with nominal concentration of the 10-3 M was grown by the vertical Bridgman technique. The imaging performance of CsI:Tl scintillator was studied as a function of the design type and thickness, since it interferes with the light scattering and, hence, the detection efficiency plus final image resolution. The result of the diffraction X-ray analysis in the grown crystals was consistent with the pattern of a face-centered cubic (fcc) crystal structure. Slices 25 × 2 × 3 mm3 (length, thickness, height) of the crystal and mini crystals of 1 × 2 × 3 mm3 (length, thickness, height) were used for comparison in the imaging systems for X-rays. With these crystals scintillators, images of undesirable elements, such as metals in food packaging, were obtained. One-dimensional array of photodiodes and the photosensor CCD (Coupled Charge Device) component were used. In order to determine the ideal thickness of the slices of the scintillator crystal CsI:Tl, Monte Carlo method was used. 展开更多
关键词 Crystal Growth Scintillator X-RAY Imaging Systems Photodiodes Coupled Charge device
下载PDF
Calibration and Monte Carlo simulation of a single-photon counting charge-coupled device for single-shot X-ray spectrum measurements 被引量:1
10
作者 闫永宏 魏来 +8 位作者 温贤伦 吴玉迟 赵宗清 张博 朱斌 洪伟 曹磊峰 姚泽恩 谷渝秋 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第11期9-12,共4页
A Princeton Instruments PI-LCX 1300 charge-coupled device (CCD) camera used for X-ray spectrum measurements in laser-plasma experiments is calibrated using three radioactive sources and investigated with the Monte C... A Princeton Instruments PI-LCX 1300 charge-coupled device (CCD) camera used for X-ray spectrum measurements in laser-plasma experiments is calibrated using three radioactive sources and investigated with the Monte Carlo code Geant4. The exposure level is controlled to make the CCD work in single photon counting mode. A summation algorithm for obtaining accurate X-ray spectra is developed to reconstruct the X-ray spectra, and the results show that the developed algorithm effectively reduces the low-energy tail caused by split pixel events. The obtained CCD energy response shows good linearity. The detection efficiency curves from both Monte Carlo simulations and the manufacturer agree well with the experimental results. This consistency demonstrates that event losses in charge collection processes are negligible when the developed summation algorithm of sDlit Dixel events is emDloved. 展开更多
关键词 ALGORITHMS Charge coupled devices PIXELS X ray analysis X ray spectrographs X rays
原文传递
Impact of continuing scaling on the device performance of 3D cylindrical junction-less charge trapping memory
11
作者 李新开 霍宗亮 +6 位作者 靳磊 姜丹丹 洪培真 徐强 唐兆云 李春龙 叶甜春 《Journal of Semiconductors》 EI CAS CSCD 2015年第9期79-84,共6页
This work presents a comprehensive analysis of 3D cylindrical junction-less charge trapping memory device performance regarding continuous scaling of the structure dimensions. The key device performance, such as progr... This work presents a comprehensive analysis of 3D cylindrical junction-less charge trapping memory device performance regarding continuous scaling of the structure dimensions. The key device performance, such as program/erase speed, vertical charge loss, and lateral charge migration under high temperature are intensively studied using the Sentaurus 3 D device simulator. Although scaling of channel radius is beneficial for operation speed improvement, it leads to a retention challenge due to vertical leakage, especially enhanced charge loss through TPO. Scaling of gate length not only decreases the program/erase speed but also leads to worse lateral charge migration. Scaling of spacer length is critical for the interference of adjacent cells and should be carefully optimized according to specific cell operation conditions. The gate stack shape is also found to be an important factor affecting the lateral charge migration. Our results provide guidance for high density and high reliability 3D CTM integration. 展开更多
关键词 3D charge trapping devices vertical charge loss lateral charge migration semiconductor device simu-lation
原文传递
Space optical remote sensor image motion velocity vector computational modeling, error budget and synthesis 被引量:15
12
作者 王家骐 于平 +2 位作者 颜昌翔 任建岳 何斌 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第7期414-417,共4页
For space optical remote sensor (SORS) with either film or time delay and integrate charge coupled device (TDI-CCD) imaging, in order to achieve higher resolution it requires more accurate real-time image motion compe... For space optical remote sensor (SORS) with either film or time delay and integrate charge coupled device (TDI-CCD) imaging, in order to achieve higher resolution it requires more accurate real-time image motion compensation. This primarily depends on real-time computation of the image motion velocity vector (IMVV) and error budget and synthesis on related parameters. An effective modeling scheme is introduced and the derivation of IMVV equation, error budget and synthesis by Monte-Carlo method are presented in detail. This total solution was applied to SORS system test on orbit and has been confirmed to be very accurate based on the resolution, transfer function at Nyquist frequency, signal-to-noise ratio and average gray scale of the captured images. 展开更多
关键词 Charge coupled devices Imaging techniques Monte Carlo methods Remote sensing Signal to noise ratio Space optics
原文传递
Spectral calibration in spectral domain optical coherence tomography 被引量:10
13
作者 王凯 丁志华 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期902-904,共3页
A novel spectral calibration method is developed for spectral domain optical coherence tomography system. The method is based on two measurements of interference spectra from two reference mirror positions. It removes... A novel spectral calibration method is developed for spectral domain optical coherence tomography system. The method is based on two measurements of interference spectra from two reference mirror positions. It removes the influence of dispersion mismatch, and hence accurately determines the spectral distribution on the line-scan charge-coupled device (CCD) for sequent precise interpolation. High quality imaging can be realized with this method. Elimination of the degradation effect caused by dispersion mismatch is verified experimentally, and improved two-dimensional (2D) imaging of fresh orange pulp based on the proposed spectral calibration method is demonstrated. 展开更多
关键词 CALIBRATION Charge coupled devices Diagnostic radiography Medical imaging Optical tomography PHOTODEGRADATION Strain measurement TOMOGRAPHY
原文传递
Measurement of spatial object's exterior attitude based on linear CCD 被引量:6
14
作者 艾莉莉 袁峰 丁振良 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第7期505-509,共5页
It is difficult to realize real-time measurement of exterior attitude by the traditional systems based on the area image sensor which have conflict between speed and accuracy. The subsystem for three-dimensional (3D... It is difficult to realize real-time measurement of exterior attitude by the traditional systems based on the area image sensor which have conflict between speed and accuracy. The subsystem for three-dimensional (3D) coordinate reconstruction of point target (S3DCRPT) which is composed of three one-dimensional (1D) cameras based on linear charge-coupled device (CCD) can determine the distant light spots' spatial position. The attitude angle of the measured object is determined by the spatial solution while the coordinate reconstruction is separately carried on by the S3DCRPT with some point cooperation targets (PCTs) on the measured object. A new optical system is designed to solve the interference problem with one-to-one relationship between the PCTs and the S3DCRPT optical subsystems, which improves the measurement accuracy and saves space. The mathematical model of the attitude measurement is established, and partial and global calibrations are realized for the multi-camera attitude measurement system. The test results show the feasibility of the exterior attitude measurement based on linear CCD. 展开更多
关键词 Cameras Charge coupled devices Computer networks Digital cameras KETONES Mathematical models Optical systems Real time systems RESTORATION Time measurement
原文传递
Complex-wave retrieval based on blind signal separation 被引量:3
15
作者 柴晓冬 周成鹏 +2 位作者 冯兆艳 王银花 左言胜 《Chinese Optics Letters》 SCIE EI CAS CSCD 2006年第1期11-14,共4页
In tile process of the reconstruction of digital holography. the traditional methods of diffraction and filtration are commonly adopted to recover the original complex-wave signal. Influenced by twin-image and zero-or... In tile process of the reconstruction of digital holography. the traditional methods of diffraction and filtration are commonly adopted to recover the original complex-wave signal. Influenced by twin-image and zero-order terms, the above-mentioned methods, however, either limit tile field of vision or result in the loss of the amplitude and phase. A new method for complex-wave retrieval is presented, which is based on blind signal separation. Three frames of holograms are captured by a charge coupled device (CCD) camera to form an observation signal. The term containing only amplitude and phase of complex-wave is separated, by means of independent component analysis, from the observation signal, which effectively eliminates the zero-order term. Finally. the complex-wave retrieval of pure phase wavefront is achieved. Experimental results show that this method can better recover the amplitude and phase of the original complex-wave even when there is a frequency spectrum mixture in the hologram. 展开更多
关键词 Charge coupled devices Image reconstruction Independent component analysis Signal interference Signal processing Spectrum analysis
原文传递
Particle digital in-line holography with spherical wave recording 被引量:5
16
作者 葛宝臻 吕且妮 张以谟 《Chinese Optics Letters》 SCIE EI CAS CSCD 2003年第9期517-519,共3页
In this paper, we propose a method of digital in-line holography of particle. A diverging spherical beam is used for illumination in recording hologram, the complex amplitude distribution generated by particle field a... In this paper, we propose a method of digital in-line holography of particle. A diverging spherical beam is used for illumination in recording hologram, the complex amplitude distribution generated by particle field at a single plane located in the Presnel diffraction region is recorded by CCD, and a plane beam for reconstructing hologram, then, the magnified image can be obtained by numerical reconstruction in computer. This procedure can be interpreted by Fourier optical theory and the theoretical analysis have been done in detail, the experimental results, the air freshener being subject, are also given. 展开更多
关键词 Charge coupled devices Fourier optics
原文传递
Research on high-speed TDICCD remote sensing camera video signal processing 被引量:3
17
作者 ZHANG Da XU Shu-yan MENG Qing-ju 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2009年第3期95-102,共8页
Video signal processing needs high signal-to-noise ratio (SNR) in high-speed time delay and integration charge coupled devices (TDICCD). To solve this problem, this article first analyzes the characteristics of th... Video signal processing needs high signal-to-noise ratio (SNR) in high-speed time delay and integration charge coupled devices (TDICCD). To solve this problem, this article first analyzes the characteristics of the output video signal of a new type of high-speed TDICCD and its operation principle. Then it studies the correlation double sample (CDS) method of reducing noise. Following that a synthesized processing method is proposed, including correlation double sample, programmable gain control, line calibration and digital offset control, etc. Among the methods, XRD98L59 is a video signal processor for the charge coupled device (CCD). Application of this processor to one kind of high-speed TDICCD with eight output ports achieves perfect video images. The experiment result indicates that the SNR of the images reaches about 50 dB. The video signal processing for high-speed multi-channel TDICCD is implemented, which meets the required project index. 展开更多
关键词 charge coupled device correlated double sample programmable gain control digital offset control
原文传递
Design of object surveillance system based on enhanced fish-eye lens 被引量:2
18
作者 吴健辉 杨坤涛 +1 位作者 项巧莲 张南洋 《Chinese Optics Letters》 SCIE EI CAS CSCD 2009年第2期142-145,共4页
A new method is proposed for the object surveillance system based on the enhanced fish-eye lens and the high speed digital signal processor (DSP). The improved fish-eye lens images an ellipse picture on the charge-c... A new method is proposed for the object surveillance system based on the enhanced fish-eye lens and the high speed digital signal processor (DSP). The improved fish-eye lens images an ellipse picture on the charge-coupled device (CCD) surface, which increases both the utilization rate of the 4:3 rectangular CCD and the imaging resolution, and remains the view angle of 183° The algorithm of auto-adapted renewal background subtraction (ARBS) is also explored to extract the object from the monitoring image. The experimental result shows that the ARBS algorithm has high anti-jamming ability and high resolution, leading to excellent object detecting ability from the enhanced elliptical fish-eye image under varies environments. This system has potential applications in different security monitoring fields due to its wide monitoring space, simple structure, working stability, and reliability. 展开更多
关键词 Charge coupled devices Digital cameras Digital signal processors FISH Lenses MEATS Optical instruments Security systems Signal processing
原文传递
Raman spectroscopy of Chinese human skin in vivo 被引量:2
19
作者 李永增 陈荣 +3 位作者 曾海山 黄志伟 冯尚源 谢树森 《Chinese Optics Letters》 SCIE EI CAS CSCD 2007年第2期105-107,共3页
A novel and compact near-infrared (NIR) Raman system is developed using 785-nm diode laser, volumephase technology (VPT) holographic system, and NIR intensified charge-coupled device (CCD). Signal-tonoise ratio ... A novel and compact near-infrared (NIR) Raman system is developed using 785-nm diode laser, volumephase technology (VPT) holographic system, and NIR intensified charge-coupled device (CCD). Signal-tonoise ratio (SNR) and resolution are improved compared with ordinary acquisition method by a specially designed optical fiber detector and the spectrograph image aberration correction with a parabolic-line fiber array. In 1-5 s, Raman spectra of different parts of Chinese human skin are acquired. Autofluorescence is subtracted from the raw spectrum by polynomial fitting and skin Raman spectrum is then smoothed for further analysis. 展开更多
关键词 ABERRATIONS Charge coupled devices Detectors Optical fibers POLYNOMIALS Raman scattering Semiconductor lasers Signal to noise ratio SKIN
原文传递
CCD camera automatic calibration technology and ellipse recognition algorithm 被引量:2
20
作者 孙长库 张效栋 屈云霞 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第10期585-588,共4页
A novel two-dimensional (2D) pattern used in camera calibration is presented. With one feature circle located at the center, an array of circles is photo-etched on this pattern. An ellipse recognition algorithm is p... A novel two-dimensional (2D) pattern used in camera calibration is presented. With one feature circle located at the center, an array of circles is photo-etched on this pattern. An ellipse recognition algorithm is proposed to implement the acquisition of interest calibration points without human intervention. According to the circle arrangement of the pattern, the relation between three-dimensional (3D) and 2D coordinates of these points can be established automatically and accurately. These calibration points are computed for intrinsic parameters calibration of charge-coupled device (CCD) camera with Tsai method. A series of experiments have shown that the algorithm is robust and reliable with the calibration error less than 0.4 pixel. This new calibration pattern and ellipse recognition algorithm can be widely used in computer vision. 展开更多
关键词 ALGORITHMS CALIBRATION Cameras Charge coupled devices Image processing Three dimensional Two dimensional
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部