期刊文献+
共找到1,774篇文章
< 1 2 89 >
每页显示 20 50 100
Simultaneous Determination of Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD5) in Wastewater by Near-Infrared Spectrometry 被引量:6
1
作者 Qiong YANG Zhenyao LIU Jidong YANG 《Journal of Water Resource and Protection》 2009年第4期286-289,共4页
To rapidly determine the pollution extent of wastewater, the calibration models were established for deter-mination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater by partial least squares and nea... To rapidly determine the pollution extent of wastewater, the calibration models were established for deter-mination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater by partial least squares and near infrared spectrometry of 120 samples. Spectral data preprocessing and outliers’ diagnosis were also discussed. Correlation coefficients of the models were 0.9542 and 0.9652, and the root mean square error of prediction (RMSEP) were 25.24 mg?L-1 and 12.13 mg?L-1 in the predicted range of 28.40~528.0 mg?L-1 and 16.0~305.2 mg?L-1 for Chemical Oxygen Demand and Biological Oxygen Demand, respectively. By statistical significance test, the results of determination were compared with those of stan-dard methods with no significant difference at 0.05 level. The method has been applied to simultaneous de-termination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater with satisfactory results. 展开更多
关键词 Near-Infrared SPECTROMETRY WASTEWATER BIOLOGICAL oxygen demand chemical oxygen demand
下载PDF
近红外光谱污水COD分析系统设计
2
作者 李阳 侯长宁 范日高 《福建电脑》 2024年第6期82-86,共5页
为了解决利用近红外光谱技术测定污水中的化学需氧量技术中样本数据集参数存在数据过拟合、干扰因素大、检测界面不直观等问题,本文采用一维卷积神经网络技术,建立水样近红外特征与污染指标成分含量之间的关系模型,并利用MATLAB的图形... 为了解决利用近红外光谱技术测定污水中的化学需氧量技术中样本数据集参数存在数据过拟合、干扰因素大、检测界面不直观等问题,本文采用一维卷积神经网络技术,建立水样近红外特征与污染指标成分含量之间的关系模型,并利用MATLAB的图形用户界面设计分析界面。实验结果表明,该方法预测结果良好,可实现水质污染的定性及定量的快速检测。 展开更多
关键词 污水 近红外光谱 化学需氧量预测
下载PDF
Chemical oxygen demand reduction in coffee wastewater through chemical flocculation and advanced oxidation processes 被引量:6
3
作者 ZAYAS Pérez Teresa GEISSLER Gunther HERNANDEZ Fernando 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第3期300-305,共6页
The removal of the natural organic matter present in coffee processing wastewater through chemical coagulation-flocculation and advanced oxidation processes (AOP) had been studied. The effectiveness of the removal o... The removal of the natural organic matter present in coffee processing wastewater through chemical coagulation-flocculation and advanced oxidation processes (AOP) had been studied. The effectiveness of the removal of natural organic matter using commercial flocculants and UV/H202, UV/O3 and UV/H2O2/O3 processes was determined under acidic conditions. For each of these processes, different operational conditions were explored to optimize the treatment efficiency of the coffee wastewater. Coffee wastewater is characterized by a high chemical oxygen demand (COD) and low total suspended solids. The outcomes of coffee wastewater treatment using coagulation-flocculation and photodegradation processes were assessed in terms of reduction of COD, color, and turbidity. It was found that a reduction in COD of 67% could be realized when the coffee wastewater was treated by chemical coagulation-flocculation with lime and coagulant T-1. When coffee wastewater was treated by coagulation-flocculation in combination with UV/H2O2, a COD reduction of 86% was achieved, although only after prolonged UV irradiation. Of the three advanced oxidation processes considered, UV/H2O2, UV/O3 and UV/H2O2/O3, we found that the treatment with UV/H2O2/O3 was the most effective, with an efficiency of color, turbidity and further COD removal of 87%, when applied to the flocculated coffee wastewater. 展开更多
关键词 advanced oxidation processes coagulation-flocculation: coffee wastewater chemical oxygen demand cod
下载PDF
近红外光谱的水体污染指标COD定量预测模型
4
作者 范日高 王武 +1 位作者 郑芝芳 柴琴琴 《福州大学学报(自然科学版)》 CAS 北大核心 2024年第2期228-235,共8页
针对传统化学需氧量(chemical oxygen demand, COD)检测存在检测成本高、耗时、易造成二次污染,以及现有检测模型泛化性较差等不足,难以满足水环境实时监测需求的问题,提出基于近红外光谱技术的COD快速无损定量预测模型.实验结果表明,... 针对传统化学需氧量(chemical oxygen demand, COD)检测存在检测成本高、耗时、易造成二次污染,以及现有检测模型泛化性较差等不足,难以满足水环境实时监测需求的问题,提出基于近红外光谱技术的COD快速无损定量预测模型.实验结果表明,本模型在污水COD光谱数据集上的预测性能,相较于传统机器学习算法和现有其他深度学习算法更优.测试的决定系数(R^(2))和均方根误差(E_(RMS))分别达到0.992 1和27.47 mg·L^(-1),模型卷积层的输出特征可解释性强,能有效表征关键波长点.该预测模型为实际水体COD含量快速检测提供一种新的方法. 展开更多
关键词 化学需氧量 定量预测模型 近红外光谱 水环境 实时监测 一维卷积神经网络
下载PDF
Environmental capacity of chemical oxygen demand in the Bohai Sea: modeling and calculation 被引量:5
5
作者 赵喜喜 王修林 +2 位作者 石晓勇 李克强 丁东生 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2011年第1期46-52,共7页
A three-dimensional advection-diffusion model coupled with the degradation process is established for describing the transport of chemical oxygen demand (COD). Comparison of the simulated distribution of COD at the su... A three-dimensional advection-diffusion model coupled with the degradation process is established for describing the transport of chemical oxygen demand (COD). Comparison of the simulated distribution of COD at the surface in the Bohai Sea in August, 2001 with field observations, shows that the model simulates the dataset reasonably well. The Laizhou Bay, Bohai Bay, and Liaodong Bay were contaminated heavily near shore. Based on the optimal discharge flux method, the Environmental Capacity (EC) and allocated capacities of COD in the Bohai Sea are calculated. For seawater of Grades I to IV of the Chinese National Standard, the ECs of COD in the Bohai Sea were 77×104 t/a, 116×104 t/a, 154×104 t/a and 193×104 t/a, respectively. The Huanghe (Yellow) River pollutant discharge accounted for the largest percentage of COD at 14.3%, followed by that of from the Liugu River (11.5%), and other nine local rivers below 10%. The COD level in 2005 was worse than that of Grade II seawater and was beyond the environmental capacity. In average, 35% COD reduction is called to meet the standard of Grade I seawater. 展开更多
关键词 化学需氧量 环境容量 计算能力 渤海湾 中国国家标准 污染物排放 建模 对流扩散模型
下载PDF
On-Line Measurement of the Chemical Oxygen Demand in Wastewater in a Pulp and Paper Mill Using Near Infrared Spectroscopy 被引量:5
6
作者 John Dahlbacka Josefina Nystrom +2 位作者 Torgny Mossing Paul Geladi Tom Lillhonga 《Spectral Analysis Review》 2014年第4期19-25,共7页
Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts... Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts to produce online predictions of the chemical oxygen demand (COD) in wastewater from a pulp and paper mill using NIR spectroscopy are described. The task was perceived as very challenging, but with a root mean square error of prediction of 149 mg/l, roughly corresponding to 1/10 of the studied concentration interval, this attempt was deemed as successful. This result was obtained by using partial least squares model regression, interpolated reference values for calibration purposes, and by evenly distributing the calibration data in the concentration space. This work may also represent the first industrial application of online COD measurements in wastewater using NIR spectroscopy. 展开更多
关键词 chemical oxygen demand (cod) Industrial Wastewater Near Infrared Spectroscopy (NIR) Multivariate Calibration On-Line Measurement
下载PDF
Spatial distribution and diurnal variation of chemical oxygen demand at the beginning of the rainy season in the Changjiang (Yangtze) River Estuary 被引量:2
7
作者 高学鲁 宋金明 +1 位作者 李宁 李学刚 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2007年第3期254-260,共7页
A field observation was carried out in the Changjiang (Yangtze) River Estuary from May 19 to 26, 2003. A total of 29 stations, including 2 anchored stations, were occupied through almost the whole salinity gradient. B... A field observation was carried out in the Changjiang (Yangtze) River Estuary from May 19 to 26, 2003. A total of 29 stations, including 2 anchored stations, were occupied through almost the whole salinity gradient. Based on the observation data, biogeochemistry of chemical oxygen demand (COD) was examined. Spatial distribution pattern of COD shows that it decreased downstream. The COD concentration varied generally within a narrow range of 1.24–1.60 mg/L in the zone around the river mouth, beyond which it decreased rapidly to 0.20 mg/L. In the mixed water zone, the fluctuation in COD was smaller at 2 m above the bottom layer than at the surface layer in 48 h. In the seawater zone, the 48-h fluctuation at the surface was the largest, followed by that of 5 m below the surface and 2 m above the bottom layers in a range of from 2.50 to 0.55 mg/L. Freshwater discharge was the dominant source of COD in the estuary. The average COD beyond the river mouth was 2.7 mg/L, which accorded with the Chinese seawater quality Grade I. Relationships between dissolved oxygen and biogeochemical parameters such as suspended particulate matter, dissolved organic matter and chlorophyll-a were also discussed. 展开更多
关键词 空间分布 化学 氧化需求 雨季 长江
下载PDF
2015—2019洱海COD变化特征及影响因素研究
8
作者 奚满松 沙凤兮 +2 位作者 刘艳萍 李炜 徐倩 《环境科学导刊》 2024年第1期1-7,21,共8页
通过开展洱海及主要入湖河流沟渠水质监测并应用Mann-Kendall趋势检验法、Morlet小波等方法分析洱海湖区COD变化特征。结果发现,洱海湖区的COD历史趋势具有较为明显的年际和年内变化特征,洱海湖区的COD在近年来由下降趋势转变为上升趋势... 通过开展洱海及主要入湖河流沟渠水质监测并应用Mann-Kendall趋势检验法、Morlet小波等方法分析洱海湖区COD变化特征。结果发现,洱海湖区的COD历史趋势具有较为明显的年际和年内变化特征,洱海湖区的COD在近年来由下降趋势转变为上升趋势,突变发生在2017—2018年。在此期间入湖COD负荷、气象条件均未发生突变,洱海湖区COD与入湖COD负荷相关性逐渐降低,与叶绿素和浮游植物相关性升高,反映出洱海COD趋于受内源影响。 展开更多
关键词 化学需氧量 变化特征 突变检测 叶绿素A 洱海
下载PDF
COD对2种绿藻共培养处理农村生活污水的影响
9
作者 欧红梅 任学洋 +1 位作者 范景华 朱玮琪 《安徽科技学院学报》 2023年第5期26-31,共6页
目的:探究不同化学需氧量(Chemical Oxygen Demand,COD)对藻类生长及污水中氮磷去除的影响。方法:以蛋白核小球藻和四尾栅藻(2∶1混合)为研究对象,处理不同COD的模拟农村生活污水。结果:在2~6 d,叶绿素A含量增长率随COD初始值增加而降低... 目的:探究不同化学需氧量(Chemical Oxygen Demand,COD)对藻类生长及污水中氮磷去除的影响。方法:以蛋白核小球藻和四尾栅藻(2∶1混合)为研究对象,处理不同COD的模拟农村生活污水。结果:在2~6 d,叶绿素A含量增长率随COD初始值增加而降低,COD_(400)、COD_(500)处理组的pH显著低于COD_(250)、COD_(300)处理;第2天COD_(300)、COD_(400)和COD_(500)处理组的溶解氧(DO)趋于0,且在2~4 d,DO上升幅度随COD初始浓度的增加而递减。COD_(300)对水体铵态氮的去除效果最好,最终去除率达63.3%,并显著高于COD_(500);各处理组的总磷去除率随COD初始值的增加而显著上升,其中COD_(500)处理对总磷的最终去除率达94.2%。结论:随COD升高,延缓了叶绿素A的增加以及pH和DO升高,而高浓度COD促进了总磷的去除,降低了铵态氮的去除。 展开更多
关键词 化学需氧量 蛋白核小球藻 四尾栅藻 农村生活污水
下载PDF
高COD_(Cr)煤矿矿井水臭氧氧化处理研究 被引量:1
10
作者 田云福 冯晓琴 +1 位作者 宋江锋 安富强 《山西化工》 CAS 2023年第6期200-202,共3页
为研究臭氧对煤矿矿井水中有机污染物的氧化去除性能,首先采用浸渍法以活性炭为载体制备了固载不同金属的催化剂,接着以COD_(Cr)为指标,考察了臭氧发生器电流、反应时间、催化剂种类、催化剂用量及使用次数对臭氧催化性能的影响。研究... 为研究臭氧对煤矿矿井水中有机污染物的氧化去除性能,首先采用浸渍法以活性炭为载体制备了固载不同金属的催化剂,接着以COD_(Cr)为指标,考察了臭氧发生器电流、反应时间、催化剂种类、催化剂用量及使用次数对臭氧催化性能的影响。研究结果表明,所制备的催化剂比表面积可以达到912m^(2)/g,而且孔道分布均匀。催化剂的加入可以加快臭氧氧化过程,不同催化剂催化效果顺序如下:Co基>Ni基>Fe基>Zn基>Cu基。在催化氧化过程中加入Co基催化剂,可将COD_(Cr)从135.5 mg/L降低至5 mg/L以下。所制备的催化剂具有良好的重复使用性能,重复使用100次之后,依然保持有良好的催化效果。 展开更多
关键词 矿井水 臭氧 催化 化学需氧量
下载PDF
重铬酸盐滴定法测定COD的影响因素研究 被引量:1
11
作者 赵新亭 黄河仙 +5 位作者 高茜瑶 谢沙 潘海婷 朱建辉 邓露 朱日龙 《干旱环境监测》 2023年第3期102-106,共5页
消解酸度、滴定酸度、还原性离子、消解时间等是影响重铬酸钾滴定法测定水中化学需氧量(COD)的重要因素。本文对这些影响因素开展研究,结果表明,消解酸度从50%(v/v)减少至30%,COD的测定值降低了35%~57%。氯离子的氧化产物为氯气,但采取0... 消解酸度、滴定酸度、还原性离子、消解时间等是影响重铬酸钾滴定法测定水中化学需氧量(COD)的重要因素。本文对这些影响因素开展研究,结果表明,消解酸度从50%(v/v)减少至30%,COD的测定值降低了35%~57%。氯离子的氧化产物为氯气,但采取0.025 mol/L的重铬酸盐时不能被完全氧化;铵离子单独存在时对测定COD值无贡献,但与氯离子共存时有贡献;碘离子则无此现象。 展开更多
关键词 重铬酸钾滴定法 化学需氧量(cod) 消解酸度 氯离子 铵离子
下载PDF
Analysis of the Correlation among Three Oxygen Demand Indexes in Surface Water
12
作者 Bin YANG Jing LIU Jinglong LIU 《Meteorological and Environmental Research》 CAS 2022年第2期61-64,共4页
Based on the monitoring data of chemical oxygen demand(COD),permanganate index(I Mn)and five-day biochemical oxygen demand(BOD 5)of surface water in Tongling section of Yangtze River,the linear relationship among the ... Based on the monitoring data of chemical oxygen demand(COD),permanganate index(I Mn)and five-day biochemical oxygen demand(BOD 5)of surface water in Tongling section of Yangtze River,the linear relationship among the three indexes in the annual data analysis and the internal reasons,as well as the linear relationship and changes among the three indexes in different seasons were analyzed.The results reveal that in terms of the whole year,COD,I Mn and BOD 5 had a significant correlation and good linear relationship.The fitting slopes of the three indexes were 3.89 of COD/I Mn,4.39 of COD/BOD 5 and 1.16 of I Mn/BOD 5,respectively,which corresponded to the proportional relationship among the three indexes.From the perspective of seasonal changes,there was a very significant correlation between the three indexes in spring and summer.In autumn and winter,only COD and I Mn had a good correlation,but they had a poor correlation with BOD 5. 展开更多
关键词 chemical oxygen demand Permanganate index Biochemical oxygen demand SEASON CORRELATION
下载PDF
基于量子加权最小门限单元网络的出水COD预测
13
作者 张玉泽 姚立忠 罗海军 《环境工程技术学报》 CAS CSCD 北大核心 2023年第5期1857-1864,共8页
出水化学需氧量(COD)的快速准确测量对于污水处理过程水质的动态调控至关重要。针对出水COD难以实时检测的问题,提出一种基于量子加权最小门限单元(QWMGU)神经网络的出水COD预测方法。先通过多维单步(滑动窗口)预测技术构建时间序列;然... 出水化学需氧量(COD)的快速准确测量对于污水处理过程水质的动态调控至关重要。针对出水COD难以实时检测的问题,提出一种基于量子加权最小门限单元(QWMGU)神经网络的出水COD预测方法。先通过多维单步(滑动窗口)预测技术构建时间序列;然后在最小门限单元(MGU)遗忘门、候选状态与输出环节设计量子计算机制,通过更新量子相移门矩阵替代MGU权值矩阵的更新,赋予网络神经元量子特性,并给出QWMGU模型设计的具体规则与构建流程。应用该方法对德州市污水处理厂2020年出水COD进行预测,并与5种流行预测模型进行对比,以检验模型优越性。结果表明:QWMGU网络的相对预测误差优于其他方法,且稳定性较高,其均方根误差、确定系数、平均绝对误差分别为0.073、1、0.047。该模型有助于实现污水处理厂COD的高效在线检测。 展开更多
关键词 污水处理 出水cod 最小门限单元 量子机制 模型预测
下载PDF
高盐高COD橡胶助剂生产废水的处理工艺及研究进展 被引量:2
14
作者 左秀娟 潘琳琳 +3 位作者 夏宇 魏强 郭本凯 张福超 《橡胶科技》 CAS 2023年第9期421-425,共5页
概述高盐高化学需氧量(COD)橡胶助剂生产废水的处理工艺及研究进展。分析常用的废水处理工艺如Fenton氧化法、微电解法、生化法、混凝沉淀法、吸附法、离子交换法、蒸发法、冷冻结晶法和膜分离法的优缺点,介绍废水处理工艺研究进展。高... 概述高盐高化学需氧量(COD)橡胶助剂生产废水的处理工艺及研究进展。分析常用的废水处理工艺如Fenton氧化法、微电解法、生化法、混凝沉淀法、吸附法、离子交换法、蒸发法、冷冻结晶法和膜分离法的优缺点,介绍废水处理工艺研究进展。高盐高COD废水处理工艺的研究方向将集中在新材料及物化与生化组合工艺,尽可能地提高废水中盐含量和COD等的去除率,同时降低处理成本。 展开更多
关键词 橡胶助剂 废水 含盐量 化学需氧量 处理工艺
下载PDF
废液再生型COD_(Cr)分析仪的研制及试验方法研究
15
作者 范仲全 唐怀武 +4 位作者 周磊 魏澜 许涛 付聪 万永杰 《自动化仪表》 CAS 2023年第4期102-105,共4页
针对重铬酸钾法检测水中化学需氧量(COD)产生的废液会造成环境污染的问题,设计并开发了一款可实现COD废液再生及循环利用的新型COD_(Cr)分析仪(CODet-5000型)。首先,通过向COD_(Cr)废液中加入氧化剂来氧化Cr^(3+),以提高Cr^(6+)的浓度... 针对重铬酸钾法检测水中化学需氧量(COD)产生的废液会造成环境污染的问题,设计并开发了一款可实现COD废液再生及循环利用的新型COD_(Cr)分析仪(CODet-5000型)。首先,通过向COD_(Cr)废液中加入氧化剂来氧化Cr^(3+),以提高Cr^(6+)的浓度、减小空白的吸光度。然后,采用蒸馏浓缩的方式提高废液的酸度,并过滤不溶性物质。最后,将得到的再生液作为COD_(Cr)分析仪测量所需的消解液循环使用,从而实现环境零污染。试验结果表明,该分析仪测量时具有较好的重复性和稳定性,所得数据示值误差在允许范围内。该分析仪的研制为常规COD_(Cr)分析仪实现废液循环利用、环境友好等目标提供了参考,并在环境监测仪表开发领域有着十分重要的意义,具有广阔的应用前景和市场潜力。 展开更多
关键词 环境监测 化学需氧量 cod_(Cr)分析仪 废液再生 循环利用 蒸馏浓缩 在线分析
下载PDF
掺杂碳酸钙污泥生物炭去除废水中化学需氧量(COD)的实验研究
16
作者 陈伟华 徐福华 +1 位作者 吴健 曾繁春 《上饶师范学院学报》 2023年第6期43-50,共8页
通过在污泥生物炭中添加不同含量的碳酸钙(CaCO_(3)),不同碳酸钙掺量污泥生物炭(Sludge biochar of calcium carbonate,SBC-Ca)在相同条件下得到制备,对其去除废水中化学需氧量(chemical oxygen demand,COD)的效果进行了评估。结果表明:... 通过在污泥生物炭中添加不同含量的碳酸钙(CaCO_(3)),不同碳酸钙掺量污泥生物炭(Sludge biochar of calcium carbonate,SBC-Ca)在相同条件下得到制备,对其去除废水中化学需氧量(chemical oxygen demand,COD)的效果进行了评估。结果表明:CaCO_(3)比例为9%的污泥生物炭为最佳掺量;通过正交试验,最佳设计组合为A_(1)B_(2)C_(1)D_(3)E_(1),即吸附时间为60min,生物炭投加量为4.0g/L,pH6.0,温度为25℃,COD初始质量浓度为689.09mg/L;在最佳碳酸钙掺量下,SBC-Ca对废水中COD的去除量为166.08mg/g,去除率高达97.83%;比表面积和孔径分析显示SBC-Ca比表面积为39.86m^(2)/g,中孔量较多;红外光谱图表明含有-OH、C=O、C-O、Si-H等官能团;X射线衍射(X-Ray diffraction,XRD)谱图和扫描电子显微镜(scanning electron microscope,SEM)图显示SBC-Ca负载了CaCO_(3)。 展开更多
关键词 碳酸钙 剩余污泥 生物炭 废水 吸附 化学需氧量(cod)
下载PDF
UV法COD监测仪在城市污水管网中的应用
17
作者 赵云飞 赵丛丛 任紫嫣 《建设科技》 2023年第10期26-31,共6页
紫外分光光度法(UV法)用于污水管网节点的化学需氧量(COD)在线监测是一种简单快速的物理测量方法,与传统化学法相比经济、环保。本研究对北方某城市污水处理厂进水主干管上游水质COD指标进行实时监测,并对UV法监测数据进行量值溯源。结... 紫外分光光度法(UV法)用于污水管网节点的化学需氧量(COD)在线监测是一种简单快速的物理测量方法,与传统化学法相比经济、环保。本研究对北方某城市污水处理厂进水主干管上游水质COD指标进行实时监测,并对UV法监测数据进行量值溯源。结果表明,UV法适用于成分相对稳定的污水COD的快速测定,需结合待测水样的国标法检测数据来建立校准模型,校准后的数据能够达到较高的数据精度。 展开更多
关键词 紫外分光光度法 化学需氧量 污水管网
下载PDF
典型重金属离子对SBR脱氮工艺及COD去除的影响研究进展
18
作者 吕明泽 李迪林 +3 位作者 高文龙 侯胜鹏 王亚琪 陈萌 《市政技术》 2023年第3期176-181,190,共7页
氮是目前导致水体富营养化的主要污染物质,而化学需氧量(COD)是体现水体中有机物污染情况的主要指标。近年来,SBR工艺作为一种应用广泛的污水处理工艺,在生物脱氮技术中也备受关注。实际含氮废水中,通常含有一定量的重金属,包括Zn、Cu... 氮是目前导致水体富营养化的主要污染物质,而化学需氧量(COD)是体现水体中有机物污染情况的主要指标。近年来,SBR工艺作为一种应用广泛的污水处理工艺,在生物脱氮技术中也备受关注。实际含氮废水中,通常含有一定量的重金属,包括Zn、Cu和Ni等。这些重金属的存在,会抑制微生物的代谢能力,严重影响氮和COD的去除。选取含氮废水中的3种典型重金属离子(Cu^(2+)、Zn^(2+)和Ni^(2+)),进行了其对SBR工艺中脱氮效能的相关影响研究。研究结果表明:在较低质量浓度情况下,Cu^(2+)、Zn^(2+)和Ni^(2+)3种典型重金属离子对脱氮及COD的去除有一定的促进作用;在高质量浓度情况下,对脱氮及COD去除会产生抑制作用,且随质量浓度的增加而抑制作用增强。 展开更多
关键词 重金属离子 SBR工艺 生物脱氮 cod去除
下载PDF
一种低成本高精度COD在线分析仪设计方案
19
作者 白泽霖 宁可 《自动化应用》 2023年第3期101-104,共4页
该COD在线分析仪采用重珞酸钾氧化-快速消解分光光度法检测原理:经预处理的水样在高温高压封闭条件下被重洛酸钾氧化消解,再经过光度检测,完成COD浓度的快速测定。仪器采用的测量方法符合《水质化学需氧量的测定重洛酸盐法》和《水质化... 该COD在线分析仪采用重珞酸钾氧化-快速消解分光光度法检测原理:经预处理的水样在高温高压封闭条件下被重洛酸钾氧化消解,再经过光度检测,完成COD浓度的快速测定。仪器采用的测量方法符合《水质化学需氧量的测定重洛酸盐法》和《水质化学需氧量的测定快速消解分光光度法》的标准要求。该款污水COD速测仪性能稳定、维护量小。 展开更多
关键词 化学需氧量 吸光度 消解时间 高精度注射泵 分析仪
下载PDF
进水COD对Anammox-UASB反应性能的影响
20
作者 申慧彦 张宇 +2 位作者 姚亮 余丽 李卫华 《安徽建筑大学学报》 2023年第4期57-63,共7页
为研究进水COD对厌氧氨氧化(Anaerobic ammonium oxidation,Anammox)反应性能的影响,搭建上流式厌氧污泥床(upflow anaerobic sludge bed,UASB),以葡萄糖为碳源,结合荧光光谱表征反应器出水组分的改变。结果表明,进水COD≤60 mg/L时,Ana... 为研究进水COD对厌氧氨氧化(Anaerobic ammonium oxidation,Anammox)反应性能的影响,搭建上流式厌氧污泥床(upflow anaerobic sludge bed,UASB),以葡萄糖为碳源,结合荧光光谱表征反应器出水组分的改变。结果表明,进水COD≤60 mg/L时,Anammox反应没有受到影响;COD=80 mg/L时,Anammox和反硝化共同作用,有利于去除TN;COD≥100 mg/L时,TN去除率开始下降,异养反硝化菌为优势菌,Anammox反应受到抑制;进水COD继续提高,将导致Anammox反应失败。三维荧光光谱联合平行因子、荧光区域积分分析表明,Anammox正常运行时,出水类蛋白物质相对稳定;Anammox反应受到进水高浓度COD影响时,出水类蛋白物质增加。 展开更多
关键词 cod 厌氧氨氧化 脱氮性能 三维荧光光谱
下载PDF
上一页 1 2 89 下一页 到第
使用帮助 返回顶部