期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Chemiluminescence Determination of Molybdenum by on-Line Reduction with a Flow Injection System 被引量:4
1
作者 Zhi Jia ZHU (Experimental Center, Hebei Normal University, Shijiazhuang 050016) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第5期427-430,共4页
The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination o... The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination of trace amount of molybdenum has been established. The emission intensity was linear with molybdenum concentration in the range of 0.1-1000 ng/mL; the detection limit was 0.02 ng/mL molybdenum; the relative standard deviation was less than 2% for the determination of 0.1 ng/mL molybdenum (n=11). The method has been applied successfully to the analysis of trace molybdenum in water and steel samples. 展开更多
关键词 chemiluminescence analysis reductant FLOW-INJECTION MOLYBDENUM LUCIGENIN
下载PDF
Study on Quenching Effect of Holmium (Ⅲ) Ion in Chemiluminescence System of Luminol H_2O_2-Cr(Ⅲ) by Flow Injection Technique
2
作者 朱智甲 《Rare Metals》 SCIE EI CAS CSCD 2000年第1期39-41,共3页
A new chemiluminescence (CL) analytical method for determination of rare earth Ho(Ⅲ) ion is reported. It is based on the quenching effect of Ho(Ⅲ) ion on CL intensity of Luminol H 2O 2 Cr(Ⅲ) system. The detecti... A new chemiluminescence (CL) analytical method for determination of rare earth Ho(Ⅲ) ion is reported. It is based on the quenching effect of Ho(Ⅲ) ion on CL intensity of Luminol H 2O 2 Cr(Ⅲ) system. The detection limit is 3×10 -8 mol/L, the linear range is from 1×10 -7 to 1×10 -4 mol/L; the relative standard deviation is less than 3% (for 2×10 -7 mol/L Ho, n=11). The method was applied to determination of Ho(Ⅲ) in pure samples with satisfactory results. 展开更多
关键词 HOLMIUM Flow injection chemiluminescence analysis LUMINOL
下载PDF
SELECTIVE SULFUR DIOXIDE DETERMINATION BY GAS DIFFUSION FLOW INJECTION ANALYSIS WITH CHEMILUMINESCENT DETECTION
3
作者 Yong He BAO Qi Jun SONG Department of Chemistry,XingJiang University,Urumchi,830046 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第4期313-314,共2页
Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffu... Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffusion separation system.This permits the determination of sulfur dioxide selectively and rapidly. 展开更多
关键词 FLOW SELECTIVE SULFUR DIOXIDE DETERMINATION BY GAS DIFFUSION FLOW INJECTION analysis WITH CHEMILUMINESCENT DETECTION GAS
下载PDF
Flow-injection Chemiluminescence Sensor for Hydrogen Peroxide with Immobilized Reagents
4
作者 Bao Xin LI Wei QIN Zhu Jun ZHANG (Department of Chemistry, Shaanxi Normal University, Xi’an 710062) 《Chinese Chemical Letters》 SCIE CAS CSCD 1998年第5期471-472,共2页
A novel chemiluminescence (CL) sensor for H2O2 combined with flow injection analysis is described in this paper. H2O2 is sensed by the CL reaction with luminol and Co2+ bleeding from the ion exchange column with immob... A novel chemiluminescence (CL) sensor for H2O2 combined with flow injection analysis is described in this paper. H2O2 is sensed by the CL reaction with luminol and Co2+ bleeding from the ion exchange column with immobilized reagents by hydrolysis. The calibration graph is linear and falls between the range of 4x10(-8) to 1x10(-5) mol/L. A complete analysis could be performed in 1 min. The system was reused for over 50 hours. 展开更多
关键词 chemiluminescence H2O2 analysis LUMINOL CO(II)
全文增补中
Determination of Lanthanu m in Lu minol- H_2 O_2- Cr( Ⅲ) Syste m by Flow Injection Chemilu minescence
5
作者 朱智 周清 《Rare Metals》 SCIE EI CAS CSCD 1999年第3期225-228,共4页
A novel method of flow injection chemiluminescence (CL) analysis for the determination of rare earth La(Ⅲ) ion is prensented. It is based on the quenching effect of La(Ⅲ) ion in the CL system of Luminol H 2O 2 ... A novel method of flow injection chemiluminescence (CL) analysis for the determination of rare earth La(Ⅲ) ion is prensented. It is based on the quenching effect of La(Ⅲ) ion in the CL system of Luminol H 2O 2 Cr(Ⅲ). The CL emission intensity is linear with La(Ⅲ) concentration in the range 1×10 -7 ~1×10 -4 mol/L; the detection limit is 4×10 -8 mol/L, the relative standard deviation is less than 3% (for 2×10 -7 mol/L La, n =11). 展开更多
关键词 Rare earth La(Ⅲ) Flow injection chemiluminescence analysis LUMINOL
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部