Objective: This study aimed to establish chemiluminescent immunoassay (CLIA) for quantitative determination of theophylline levels in human serum. Methods: To measure the concentration of theophylline (n=122) and eval...Objective: This study aimed to establish chemiluminescent immunoassay (CLIA) for quantitative determination of theophylline levels in human serum. Methods: To measure the concentration of theophylline (n=122) and evaluate the assay.Results: The linear range of the CLIA method was 0.51~40 mg/L (Y=1.02X+0.44, r=0.995). The intra and inter CV (coefficient variance) of CLIA were 3.20% and 3.57%, respectively. The average recovery rate was 102.3%. This method was free from interference by brilirubin (<200 μmol/L), hemoglobin (<10 g/L), and triglycerides (<15 mmol/L). Conclusion: This method is simple, convenient and precise for clinical pharmacokinetics study oftheophylline.展开更多
Immunoassays greatly contribute to veterinary drug residue analysis. However, there are few reports on detecting neomycin residues by immunoassay. Here, a rapid and sensitive chemiluminescent enzyme immunoassay (CLIE...Immunoassays greatly contribute to veterinary drug residue analysis. However, there are few reports on detecting neomycin residues by immunoassay. Here, a rapid and sensitive chemiluminescent enzyme immunoassay (CLIEA) was successfully developed for neomycin residue analysis. CLIEA demonstrated good cross-reactivity for neomycin, and the IC50 value was 2.4 ng/mL in buffer.展开更多
A new method of chemiluminescent enzyme immunoassay (CLEIA) was developed and the standard curve and regression equation for determination of progesterone receptor (PR) made. The luminosity of tissue samples was teste...A new method of chemiluminescent enzyme immunoassay (CLEIA) was developed and the standard curve and regression equation for determination of progesterone receptor (PR) made. The luminosity of tissue samples was tested and PR level was calculated by the regression equation. Correlation analysis revealed that there was a linear relationship between different concentrations of the standard PR samples and the corresponding values of luminosity: Y=3748+463.77X, γ=0 9958. The values of the luminosity in 38 cases of tumor tissues were determined with the highest being 267.32 fmol/mg, the lowest 3.69 fmol/mg and the mean 78.53 fmol/mg. The new method of CLEIA was a stable, creditable,specific and sensitive assay for determination of PR.展开更多
A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELI...A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA).A systematic comparison between the MmPs-CLEIA and colorimetric ELISA concluded that the MPs-CLEIA exhibited fewer dosages of immunoreagents,less total assay time,and better linearity,recovery,precision,sensitivity and validity.AFP was detected in forty human serum samples by the proposed MPs-CLEIA and ELISA,and the results were compared with commercial electrochemiluminescence immunoassay (ECLIA) kit.The correlation coefficient between MPs-CLEIA and ELISA was obtained with R 2 0.6703;however,the correlation between MPs-CLEIA and ECLIA (R 2 0.9582) was obviously better than that between colorimetric ELISA and ECLIA (R 2 0.6866).展开更多
This paper described a new immunoassay method by capillary electrophoresis with enhanced chemiluminescence (CL) detection system based on luminol-hydrogen peroxide reaction catalyzed by horseradish peroxides (HRP). Us...This paper described a new immunoassay method by capillary electrophoresis with enhanced chemiluminescence (CL) detection system based on luminol-hydrogen peroxide reaction catalyzed by horseradish peroxides (HRP). Using para-iodophenol as a CL enhancer, the detection limit of about 1×10-12 mol/L for HRP was achieved, which corresponded to 1.32×10-5 U/mL. In optimal conditions, the free HRP-labeled CA125 antibody (Ab*) and the bound enzyme-labeled complex (Ab*-Ag) were well separated by capillary electrophoresis within 4 min. The assay was successfully used to determine the contents of CA125 in human sera, which were associated with ovarian cancer, and the recoveries of the standard addition experiments were 96 to 109 %.展开更多
文摘Objective: This study aimed to establish chemiluminescent immunoassay (CLIA) for quantitative determination of theophylline levels in human serum. Methods: To measure the concentration of theophylline (n=122) and evaluate the assay.Results: The linear range of the CLIA method was 0.51~40 mg/L (Y=1.02X+0.44, r=0.995). The intra and inter CV (coefficient variance) of CLIA were 3.20% and 3.57%, respectively. The average recovery rate was 102.3%. This method was free from interference by brilirubin (<200 μmol/L), hemoglobin (<10 g/L), and triglycerides (<15 mmol/L). Conclusion: This method is simple, convenient and precise for clinical pharmacokinetics study oftheophylline.
基金supported by the project for talent training and development of the China National Center for Food Safety Risk Assessment(523 plan)Natural Science Foundation of Guangdong Province(No.2014A030310289 and No.2016A020210055)+1 种基金Natural Science Foundation of SZU(No.201576)National Natural Science Foundation of China(No.21107104)
文摘Immunoassays greatly contribute to veterinary drug residue analysis. However, there are few reports on detecting neomycin residues by immunoassay. Here, a rapid and sensitive chemiluminescent enzyme immunoassay (CLIEA) was successfully developed for neomycin residue analysis. CLIEA demonstrated good cross-reactivity for neomycin, and the IC50 value was 2.4 ng/mL in buffer.
文摘A new method of chemiluminescent enzyme immunoassay (CLEIA) was developed and the standard curve and regression equation for determination of progesterone receptor (PR) made. The luminosity of tissue samples was tested and PR level was calculated by the regression equation. Correlation analysis revealed that there was a linear relationship between different concentrations of the standard PR samples and the corresponding values of luminosity: Y=3748+463.77X, γ=0 9958. The values of the luminosity in 38 cases of tumor tissues were determined with the highest being 267.32 fmol/mg, the lowest 3.69 fmol/mg and the mean 78.53 fmol/mg. The new method of CLEIA was a stable, creditable,specific and sensitive assay for determination of PR.
基金supported by the National Basic Research Program of China (973 Program,no. 2007CB714507)National Nature Science Foundation of China (no. 90813015)
文摘A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA).A systematic comparison between the MmPs-CLEIA and colorimetric ELISA concluded that the MPs-CLEIA exhibited fewer dosages of immunoreagents,less total assay time,and better linearity,recovery,precision,sensitivity and validity.AFP was detected in forty human serum samples by the proposed MPs-CLEIA and ELISA,and the results were compared with commercial electrochemiluminescence immunoassay (ECLIA) kit.The correlation coefficient between MPs-CLEIA and ELISA was obtained with R 2 0.6703;however,the correlation between MPs-CLEIA and ECLIA (R 2 0.9582) was obviously better than that between colorimetric ELISA and ECLIA (R 2 0.6866).
基金supported by the National Natural Science Foundation of China(No.20271033)the key project of National Natural Science Foundation of China(No.20335020)Natural Science Foundation of Shanghai(No.02ZA14057).
文摘This paper described a new immunoassay method by capillary electrophoresis with enhanced chemiluminescence (CL) detection system based on luminol-hydrogen peroxide reaction catalyzed by horseradish peroxides (HRP). Using para-iodophenol as a CL enhancer, the detection limit of about 1×10-12 mol/L for HRP was achieved, which corresponded to 1.32×10-5 U/mL. In optimal conditions, the free HRP-labeled CA125 antibody (Ab*) and the bound enzyme-labeled complex (Ab*-Ag) were well separated by capillary electrophoresis within 4 min. The assay was successfully used to determine the contents of CA125 in human sera, which were associated with ovarian cancer, and the recoveries of the standard addition experiments were 96 to 109 %.