Generic load regulation strategy for enhancing energy efficiency of chiller plants
1
作者 Hang Wan Yuyang Gong +3 位作者 Shengwei Wang Yongjun Sun Tao Xu Gongsheng Huang 《Building Simulation》 SCIE EI 2024年第8期1273-1287,共15页
In many chiller plants,high coefficient of performance(COP)is only achieved at a few favorable part load ratios(PLRs),while the COP is low at many other non-favorable PLRs.To address this issue,this study proposes a g... In many chiller plants,high coefficient of performance(COP)is only achieved at a few favorable part load ratios(PLRs),while the COP is low at many other non-favorable PLRs.To address this issue,this study proposes a generic load regulation strategy that aims to maintain chiller plants operating at high COP,particularly under non-favorable PLRs.This is achieved by incorporating thermal energy storage(TES)units and timely optimizing the charging and discharging power of the integrated TES units.The optimal charging and discharging power is determined by solving a dynamic optimization problem,taking into account the performance constraints of the TES units and the chiller plants.To provide an overview of the energy-saving potential of the proposed strategy,a comprehensive analysis was conducted,considering factors such as building load profiles,COP/PLR curves of chillers,and attributes of the TES units.The analysis revealed that the proposed load regulation strategy has the potential to achieve energy savings ranging from 5.7%to 10.8%for chiller plants with poor COPs under unfavorable PLRs,particularly in buildings with significant load variations. 展开更多
关键词 load regulation thermal energy storage chiller plants building energy efficiency
原文传递
Optimum control strategy for all-variable speed chiller plant 被引量:3
2
作者 蒋小强 龙惟定 李敏 《Journal of Central South University》 SCIE EI CAS 2011年第2期573-579,共7页
The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation ... The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant. 展开更多
关键词 chiller plant control strategy variable speed cooling water flow rate chilled water flow rate
下载PDF
Hybrid Chiller Plant Optimization Strategies for Hotel Building on Nile River of Egypt
3
作者 Tarek A. Mouneer Mohamed H. Aly 《Journal of Power and Energy Engineering》 2021年第4期61-88,共28页
Hybrid<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family... Hybrid<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">chiller plants (HCPs)</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">using multiple chillers and different energy sources</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">are highly recommended in several energy applications in non-residential buildings such as hospitals and hotels. Time of use and cooling load profiles are significant factors that should be carefully considered either in chiller plant design or in chiller sequencing operation. This article aims to present an operation planning of HCP which consists of both electric and non-electric chillers. Four operational strategies are proposed and solved to compare their coefficients of performance and economics of running costs. A typical hotel building located on the Nile river in Egypt is selected to perform the current thermal and economic case study. The total cooling load profile of this hotel building is 4000 refrigeration tonnage (TR), which </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">is </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">simulated to optimize chiller sequence of operation and to select optimal design conditions of both numbers for electric and non-electric chillers used in HCP. The results of this comparative study for running cost are defined using various design configurations with different several chiller sequences available for each configuration. Then, the results of COPs, and operational running cost and initial cost are presented in this article also. The comparison aims to find the optimal design and operational sequencing for HCPs on thermal basis and economic analysis which were attached in this article. Recommendations and suggestions for future work are attached at the end of this article.</span></span></span> 展开更多
关键词 Hybrid chiller Plant Sustainability in Buildings AIR-CONDITIONING Hotel Building chiller Sequencing Building Cooling
下载PDF
An optimization-oriented modeling approach using input convex neural networks and its application on optimal chiller loading 被引量:1
4
作者 Shanshuo Xing Jili Zhang Song Mu 《Building Simulation》 SCIE EI CSCD 2024年第4期639-655,共17页
Optimization for the multi-chiller system is an indispensable approach for the operation of highly efficient chiller plants.The optima obtained by model-based optimization algorithms are dependent on precise and solva... Optimization for the multi-chiller system is an indispensable approach for the operation of highly efficient chiller plants.The optima obtained by model-based optimization algorithms are dependent on precise and solvable objective functions.The classical neural networks cannot provide convex input-output mappings despite capturing impressive nonlinear fitting capabilities,resulting in a reduction in the robustness of model-based optimization.In this paper,we leverage the input convex neural networks(ICNN)to identify the chiller model to construct a convex mapping between control variables and the objective function,which enables the NN-based OCL as a convex optimization problem and apply it to multi-chiller optimization for optimal chiller loading(OCL).Approximation performances are evaluated through a four-model comparison based on an experimental data set,and the statistical results show that,on the premise of retaining prior convexities,the proposed model depicts excellent approximation power for the data set,especially the unseen data.Finally,the ICNN model is applied to a typical OCL problem for a multi-chiller system and combined with three types of optimization strategies.Compared with conventional and meta-heuristic methods,the numerical results suggest that the gradient-based BFGS algorithm provides better energy-saving ratios facing consecutive cooling load inputs and an impressive convergence speed. 展开更多
关键词 chiller plant input convex neural network optimal load distribution convex optimization
原文传递
A non-cooperative game-based distributed optimization method for chiller plant control
5
作者 Shiyao Li Yiqun Pan +1 位作者 Qiujian Wang Zhizhong Huang 《Building Simulation》 SCIE EI CSCD 2022年第6期1015-1034,共20页
The heating,ventilation,and air-conditioning(HVAC)systems account for about half of the building energy consumption.The optimization methodology access to optimal control strategies of chiller plant has always been of... The heating,ventilation,and air-conditioning(HVAC)systems account for about half of the building energy consumption.The optimization methodology access to optimal control strategies of chiller plant has always been of great concern as it significantly contributes to the energy use of the whole HVAC system.Given that conventional centralized optimization methods relying on a central operator may suffer from dimensionality and a tremendous calculation burden,and show poorer flexibility when solving complex optimization issues,in this paper,a novel distributed optimization approach is presented for chiller plant control.In the proposed distributed control scheme,both trade-offs of coupled subsystems and optimal allocation among devices of the same subsystem are considered by developing a double-layer optimization structure.Non-cooperative game is used to mathematically formulate the interaction between controlled components as well as to divide the initial system-scale nonlinear optimization problem into local-scale ones.To solve these tasks,strategy updating mechanisms(PSO and IPM)are utilized.In this way,the approximate global optimal controlled variables of devices in the chiller plant can be obtained in a distributed and local-knowledge-enabled way without neither global information nor the central workstation.Furthermore,the existence and effectiveness of the proposed distributed scheme were verified by simulation case studies.Simulation results indicate that,by using the proposed distributed optimization scheme,a significant energy saving on a typical summer day can be obtained(1809.47 kW·h).The deviation from the central optimal solution is 3.83%. 展开更多
关键词 chiller plant operation optimization distributed optimization non-cooperative game double-layer optimization graph theory
原文传递
Energy modeling and optimization of building condenser water systems with all-variable speed pumps and tower fans:A case study
6
作者 Yong Cao Chuang Wang +2 位作者 Sheng Wang Xiao Fu Xinguo Ming 《Building Simulation》 SCIE EI 2024年第7期1085-1111,共27页
The emergence of building condenser water systems with all-variable speed pumps and tower fans allows for increased efficiency and flexibility of chiller plants in partial load operation but also increases the control... The emergence of building condenser water systems with all-variable speed pumps and tower fans allows for increased efficiency and flexibility of chiller plants in partial load operation but also increases the control complexity of condenser water systems.This study aims to develop an integrated modeling technique for evaluating and optimizing the energy performance of such a condenser water system.The proposed system model is based on the semi-physical semi-empirical chiller,pump,and cooling tower models,with capabilities of fully considering the hydraulic and thermal interactions in the condenser water loop,being solved analytically and much faster than iterative solvers and supporting the explicit optimization of the pump and tower fan frequency.A mathematical approach,based on the system model and constrained optimization technique,is subsequently established to evaluate the energy performance of a typical dual setpoint-based variable speed strategy and find its energy-saving potential and most efficient operation by jointly optimizing pumps and tower fans.An all-variable speed chiller plant from Wuhan,China,is used for a case study to validate the system model’s accuracy and explore its applicability.The results showed that the system model can accurately simulate the condenser water system’s performance under various operating conditions.By optimizing the frequencies of pumps and tower fans,the total system energy consumption can be reduced by 12%–13%compared to the fixed dual setpoint-based strategy with range and approach setpoints of 4℃and 2℃.In contrast,the energy-saving potential of optimizing the cooling tower sequencing is insignificant.A simple joint speed control method for optimizing the pumps and tower fans emerged,i.e.,the optimal pump and fan frequency are linearly correlated(if both are non-extremes)and depend on the chiller part load ratio only,irrespective of the ambient wet-bulb temperature and chilled water supply temperature.It was also found that the oversizing issue has further limited the energy-saving space of the studied system and results in the range and approach setpoints being inaccessible.The study’s findings can serve as references to the operation optimization of all-variable speed condenser water systems in the future. 展开更多
关键词 all-variable speed chiller plant model-based optimization hydraulic and thermal coupling analytical solution dual setpoint-based variable speed control optimal joint speed control