期刊文献+
共找到392篇文章
< 1 2 20 >
每页显示 20 50 100
Optimal Operation Strategies for a Large Multi-Chiller System Based on Cooling Load Forecast
1
作者 Yanyue Lu Junghui Chen Yuanbin Mo 《Journal of Software Engineering and Applications》 2019年第12期540-561,共22页
In semiconductor and electronics factories, large multi-chiller systems are needed to satisfy strict cooling load requirements. In order to save energy, it is worthwhile to design the chilled water system operation. I... In semiconductor and electronics factories, large multi-chiller systems are needed to satisfy strict cooling load requirements. In order to save energy, it is worthwhile to design the chilled water system operation. In this paper, an optimal flexible operation scheme is developed based on a two-dimensional time-series model to forecast the cooling load of multi-chiller systems with chiller units of different cooling capacities running in parallel. The optimal integrity scheme can be obtained using the Mixed Integer Nonlinear Programming method, which minimizes the energy consumption of the system within a future time period. In order to better adapt the change of cooling load, the operation strategy of regulating the chilled water flowrates is employed. The chilled water flowrates are set as a design variable. When the chillers are running, their chilled water flowrates can vary within limits, whereas the flowrates are zero when the chillers are unloaded. This forecasting method provides integral optimization within a future time period and offers the operating reference for operators. The power and advantages of the proposed method are presented using an industrial case to help readers delve into this matter. 展开更多
关键词 LARGE Multi-chiller system Operation STRATEGIES Cooling Load FORECAST Energy Saving Optimal Design
下载PDF
Modelling of Chillers for Energy Performance Assessment of HVAC Systems
2
作者 Luigi Schibuola Massimiliano Scarpa Chiara Tambani 《Journal of Energy and Power Engineering》 2014年第6期1012-1020,共9页
The reliable assessment of the annual energy demand has become necessary in view of building energy performance certification. Accurate models must be used to simulate the behaviour of HVAC (heating, ventilation and ... The reliable assessment of the annual energy demand has become necessary in view of building energy performance certification. Accurate models must be used to simulate the behaviour of HVAC (heating, ventilation and air conditioning) components in real operation, usually characterized by a wide variation of building loads. In this context, this paper deals with the development and validation of an algorithm aimed at the assessment of part load performance of various kinds of controls for vapour compresion based heat pumps and chillers, in particular referring to on-off, inverter-driven and multi-stage vapour compression. The reliability of this algorithm in the calculation of seasonal performances is checked against monitoring of heat pumps and chillers operating under real conditions. 展开更多
关键词 MODELLING chiller part load energy performance building certification.
下载PDF
Performance analysis on a novel water chiller using liquid desiccant
3
作者 曹熔泉 张小松 殷勇高 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期192-196,共5页
A new type of liquid desiccant water chiller for applications on air-conditioning and refrigeration is introduced.The system can be driven by low-grade heat sources with temperatures of 60 to 80 ℃,which can be easily... A new type of liquid desiccant water chiller for applications on air-conditioning and refrigeration is introduced.The system can be driven by low-grade heat sources with temperatures of 60 to 80 ℃,which can be easily obtained by a flat plat solar collector,waste heat,etc.A numerical model is developed to study the system performance.The effects of different parameters on performance are discussed,including evaporating temperature,regenerating temperature,ambient condition,and mass flow rates of closed moist air and regenerating air.The results show that an acceptable performance of a cooling capacity of 2.5 kW and a coefficient of performance of 0.37 can be achieved in a reference case.The regenerating temperature and the humidity ratios of ambient air are two main factors affecting system performance,while the temperature of ambient air functions less.In addition,the mass flow rate of regenerating air and closed moist air should be carefully determined for economical operation. 展开更多
关键词 liquid desiccant water chiller coefficient of perfor-mance low-grade energy utilization
下载PDF
Optimum control strategy for all-variable speed chiller plant 被引量:3
4
作者 蒋小强 龙惟定 李敏 《Journal of Central South University》 SCIE EI CAS 2011年第2期573-579,共7页
The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation ... The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant. 展开更多
关键词 chiller plant control strategy variable speed cooling water flow rate chilled water flow rate
下载PDF
Chiller faults detection and diagnosis with sensor network and adaptive 1D CNN 被引量:3
5
作者 Ke Yan Xiaokang Zhou 《Digital Communications and Networks》 SCIE CSCD 2022年第4期531-539,共9页
Computer-empowered detection of possible faults for Heating,Ventilation and Air-Conditioning(HVAC)subsystems,e.g.,chillers,is one of the most important applications in Artificial Intelligence(AI)integrated Internet of... Computer-empowered detection of possible faults for Heating,Ventilation and Air-Conditioning(HVAC)subsystems,e.g.,chillers,is one of the most important applications in Artificial Intelligence(AI)integrated Internet of Things(IoT).The cyber-physical system greatly enhances the safety and security of the working facilities,reducing time,saving energy and protecting humans’health.Under the current trends of smart building design and energy management optimization,Automated Fault Detection and Diagnosis(AFDD)of chillers integrated with IoT is highly demanded.Recent studies show that standard machine learning techniques,such as Principal Component Analysis(PCA),Support Vector Machine(SVM)and tree-structure-based algorithms,are useful in capturing various chiller faults with high accuracy rates.With the fast development of deep learning technology,Convolutional Neural Networks(CNNs)have been widely and successfully applied to various fields.However,for chiller AFDD,few existing works are adopting CNN and its extensions in the feature extraction and classification processes.In this study,we propose to perform chiller FDD using a CNN-based approach.The proposed approach has two distinct advantages over existing machine learning-based chiller AFDD methods.First,the CNN-based approach does not require the feature selection/extraction process.Since CNN is reputable with its feature extraction capability,the feature extraction and classification processes are merged,leading to a more neat AFDD framework compared to traditional approaches.Second,the classification accuracy is significantly improved compared to traditional methods using the CNN-based approach. 展开更多
关键词 chiller Fault detection and diagnosis Deep learning neural network Long short term memory Recurrent neural network Gated recurrent unit
下载PDF
Study on Buildings CCHP System Based on SOFC 被引量:1
6
作者 Bin Zhang Yongzhen Wang +1 位作者 Jiaqing Zheng Dan Liu 《Fluid Dynamics & Materials Processing》 EI 2020年第3期665-674,共10页
The relationship among the working temperature,pressure and current density of a Solid oxide fuel cell(SOFC)and its output power and efficiency are analyzed in the framework of a theoretical model able to provide,amon... The relationship among the working temperature,pressure and current density of a Solid oxide fuel cell(SOFC)and its output power and efficiency are analyzed in the framework of a theoretical model able to provide,among other things,the volt ampere characteristic curve.In particular,following the principle of temperature matching and cascade utilization,we consider a gas turbine(GT)and a LiBr absorption chiller to recycle the high-grade exhaust heat produced by the considered SOFC.This distributed total energy system is set up with the intent to meet typical needs of buildings for cooling,heating and power(CCHP).The total power generated by the considered SOFC and gas turbine is about 222 kW and the total power generation efficiency by low heat value of fuel(LHV)is 63.7%.In the CCHP system,the high temperature exhaust of GT is further used to drive LiBr absorption unit,which can produce about 34.8 kW cooling capacity or 84.5 kW of heat(the total energy utilization 78.03%). 展开更多
关键词 SOFC gas turbine absorption chiller CCHP total energy system
下载PDF
Possibilities of Using Solar Energy in District Cooling Systems in the Mediterranean Region 被引量:3
7
作者 John Vourdoubas 《Open Journal of Energy Efficiency》 2019年第2期21-34,共14页
Use of district heating and cooling systems has many environmental advantages compared to individual heating and cooling. Recent advances in solar energy technologies for heat and power generation have reduced their c... Use of district heating and cooling systems has many environmental advantages compared to individual heating and cooling. Recent advances in solar energy technologies for heat and power generation have reduced their cost and promoted their use instead of fossil fuels. Solar-PV energy for electricity generation and solar thermal energy for hot water production are broadly used today. Solar energy resources in the Mediterranean region are abundant while space cooling in buildings is required when solar irradiance is high. The possibility of using solar energy for fuelling water chillers providing cold water in district cooling systems in the Mediterranean basin has been investigated. Existing literature and studies concerning the use of district cooling systems globally as well as the energy sources used in them have been examined. Solar-PV energy combined with compression chillers and solar thermal energy combined with thermally driven chillers can be used for cold water production. Their overall efficiencies, converting solar energy to cold water, vary between 22% and 56% compared with 45% for compression chillers using grid electricity. It is concluded that various solar energy technologies could be used with different types of water chillers for fuelling district cooling networks in the future in the Mediterranean region. 展开更多
关键词 DISTRICT COOLING EFFICIENCY Mediterranean REGION SOLAR Energy Water chillers
下载PDF
Thermodynamic and Experimental Analysis of an Ammonia-Water Absorption Chiller 被引量:1
8
作者 Dingfeng Kong Jianhua Liu +2 位作者 Liang Zhang Hang He Zhiyun Fang 《Energy and Power Engineering》 2010年第4期298-305,共8页
A single stage ammonia-water absorption chiller with complete condensation is designed, built and tested. The apparatus is designed for a cooling capacity of 2814 W, which is obtained using electric heater as heating ... A single stage ammonia-water absorption chiller with complete condensation is designed, built and tested. The apparatus is designed for a cooling capacity of 2814 W, which is obtained using electric heater as heating source. The thermodynamic models have been derived using the First and Second Laws. Calculated results are compared with experimental data. The results show that the cooling capacity of experimental apparatus is found between 1900 and 2200 W with the actual coefficient of performance (COP) between 0.32 and 0.36. The contribution of the components to internal entropy production is analyzed. It shows that the larger irreversibility is caused by spanning the largest temperature and dissipated thermal energy by heat transfer losses at the generator and evaporator. In the experimentation, the low pressure is lower than the designed value. This is a consequence of a large capacity in the falling film absorber which performs as expected. This decreases the evaporation pressure, and the evaporating temperature could be reduced to the designed value. 展开更多
关键词 ABSORPTION chiller AMMONIA-WATER THERMODYNAMIC MODELING EXPERIMENTAL Performance
下载PDF
Energy, Exergy and Thermoeconomics Analysis of Water Chiller Cooler for Gas Turbines Intake Air Cooling 被引量:1
9
作者 Galal Mohammed Zaki Rahim Kadhim Jassim Majed Moalla Alhazmy 《Smart Grid and Renewable Energy》 2011年第3期190-205,共16页
Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the... Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the compressor has been widely used to mitigate this shortcoming. Energy and exergy analysis of a GT Brayton cycle coupled to a refrigeration air cooling unit shows a promise for increasing the output power with a little decrease in thermal efficiency. A thermo-economics algorithm is developed to estimate the economic feasibility of the cooling system. The analysis is applied to an open cycle, HITACHI-FS7001B GT plant at the industrial city of Yanbu (Latitude 24o 05” N and longitude 38o E) by the Red Sea in the Kingdom of Saudi Arabia. Result show that the enhancement in output power depends on the degree of chilling the air intake to the compressor (a 12 - 22 K decrease is achieved). For this case study, maximum power gain ratio (PGR) is 15.46% (average of 12.25%), at an insignificant decrease in thermal efficiency. The second law analysis show that the exergetic power gain ratio drops to an average 8.5%. The cost of adding the air cooling system is also investigated and a cost function is derived that incorporates time-dependent meteorological data, operation characteristics of the GT and the air intake cooling system and other relevant parameters such as interest rate, lifetime, and operation and maintenance costs. The profit of adding the air cooling system is calculated for different electricity tariff. 展开更多
关键词 Gas Turbine EXERGY Analysis Power BOOSTING Hot Climate Air Cooling Water chiller
下载PDF
Energy Performance Analysis of Ice Thermal Storage for Commercial HVAC Systems 被引量:1
10
作者 Nabil Nassif Raymond Tesiero Nihal AI Raees 《Journal of Energy and Power Engineering》 2013年第9期1713-1718,共6页
Ice thermal storage is a promising technology to reduce energy costs by shifting the cooling cost from on-peak to off-peak periods. The paper investigates the application of ice thermal storage and its impact on energ... Ice thermal storage is a promising technology to reduce energy costs by shifting the cooling cost from on-peak to off-peak periods. The paper investigates the application of ice thermal storage and its impact on energy consumption, demand and total energy cost. Energy simulation software along with a chiller model is used to simulate the energy consumption and demand for the existing office building located in central Florida. Furthermore, the study presents a case study to demonstrate the cost saving achieved by the ice storage applications. The results show that although the energy consumption may increase by using ice thermal storage, the energy cost drops significantly, mainly depending on the local utility rate structure. It found that for the investigated system the annual energy consumption increases by about 12% but the annual energy cost drops by about 3 6%. 展开更多
关键词 HVAC system ice thermal storage central plant chiller.
下载PDF
Condensing Heat Recovery of Centrifugal Chiller
11
作者 GONG Guang-cai,JIAO Jun-jun,WANG Li-ping,ZENG Wei(College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期123-126,共4页
To a kind of centrifugal water chiller with R22 and about 1 745 kW of cooling capacity,a heat exchanger was added between the outlet of compressor and original condenser to get part of or all the condensing heat.Conde... To a kind of centrifugal water chiller with R22 and about 1 745 kW of cooling capacity,a heat exchanger was added between the outlet of compressor and original condenser to get part of or all the condensing heat.Condensing heat can be recovered by compound condensing method,which adopts air-cooling model +water-cooling model or water-cooling model +water-cooling model at the condensing side of the system.By exergy analysis and experiment research on compound condensing heat recovery of centrifugal chiller,the results are obtained that the capability of the whole system increases,the energy efficiency ratio(EER)becomes 3.2~5.0 from 2.2~3.4,which implies the EER increases about 1.0~1.5,the exergy efficiency increases about 10%,and the chiller runs more stably after reformation. 展开更多
关键词 CENTRIFUGAL chiller condensing HEAT RECOVERY COMPOUND condensing method EER
下载PDF
Dynamic Performance of On-off Operation for a Small Scale Direct Fired Absorption Chiller
12
作者 Wang Lei(王磊) +1 位作者 Lu Zhen(陆震) 《Journal of Donghua University(English Edition)》 EI CAS 2001年第1期46-50,共5页
A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship betwe... A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship between pressure, temperature and concentration of the lithium bromide solution have been analyzed. The result obtained indicates that the pressure of the high pressure generator and the temperature of the exhausted smoke are the most sensitive parameters. It is also found that the transition time from a full load to a part load condition is quite long, and part load relative cooling capacity is almost near the intermittent running time ratio and oil consumption ratio. 展开更多
关键词 DIRECT fired ABSORPTION chiller part load DYNAMIC performance.
下载PDF
Performance of a Solar-Biomass Adsorption Chiller
13
作者 Najeh Ghilen Mohammed El Ganaoui +1 位作者 Slimane Gabsi Riad Benelmir 《Fluid Dynamics & Materials Processing》 EI 2023年第4期1015-1026,共12页
A dynamic model is presented for a chiller working with a composite adsorbent(silica activated carbon/CaCl2)–water pair in a solar-biomass cooling installation.The main objective is determining a link between two pos... A dynamic model is presented for a chiller working with a composite adsorbent(silica activated carbon/CaCl2)–water pair in a solar-biomass cooling installation.The main objective is determining a link between two possible evaporator configurations and the refrigerator’s performances.The two considered evaporators work at different pressure levels.The related time evolution profiles of temperature,pressure and water content are studied.Moreover,the effects of hot water inlet temperature and cooling water inlet temperature on the specific cooling capacity(SCP)and coefficient of performance(COP)are predicted by means of numerical simulations.The results show that an increase in the temperature of hot water and a decrease in the temperature of the cooling water allow an increase in COP and SCP.In particular,for a hot water inlet temperature of 85°C and a cooling water inlet temperature of 40°C,the COP and Qev are 0.67 and 4.3 kW,respectively. 展开更多
关键词 Adsorption chiller SOLAR BIOMASS PERFORMANCE
下载PDF
Optimal Scheduling for Flexible Regional Integrated Energy Systemwith Soft Open Point
14
作者 Wen Xu Dongdong Ren +3 位作者 Biyi Yi Haoqing Zhen Youbing Zhang Xuesong Zhang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第5期1101-1123,共23页
The Regional Integrated Energy System(RIES)has brought new modes of development,utilization,conversion,storage of energy.The introduction of Soft Open Point(SOP)and the application of Power to Gas(P2G)technology will ... The Regional Integrated Energy System(RIES)has brought new modes of development,utilization,conversion,storage of energy.The introduction of Soft Open Point(SOP)and the application of Power to Gas(P2G)technology will greatly deepen the coupling of the electricity-gas integrated energy system,improve the flexibility and safety of the operation of the power system,and bring a deal of benefits to the power system.On this background,an optimal dispatch model of RIES combined cold,heat,gas and electricity with SOP is proposed.Firstly,RIES architecture with SOP and P2G is designed and its mathematical model also is built.Secondly,on the basis of considering the optimal scheduling of combined cold,heat,gas and electricity,the optimal scheduling model for RIES was established.After that,the original model is transformed into a mixed-integer second-order cone programming model by using linearization and second-order cone relaxation techniques,and the CPLEX solver is invoked to solve the optimization problem.Finally,the modified IEEE 33-bus systemis used to analyze the benefits of SOP,P2G technology and lithium bromide absorption chillers in reducing systemnetwork loss and cost,as well as improving the system’s ability to absorb wind and solar and operating safety. 展开更多
关键词 Regional integrated energy system power to gas soft open point wind and photovoltaic power permeation lithium bromide chiller operating cost
下载PDF
Hybrid Chiller Plant Optimization Strategies for Hotel Building on Nile River of Egypt
15
作者 Tarek A. Mouneer Mohamed H. Aly 《Journal of Power and Energy Engineering》 2021年第4期61-88,共28页
Hybrid<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family... Hybrid<span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">chiller plants (HCPs)</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">using multiple chillers and different energy sources</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">are highly recommended in several energy applications in non-residential buildings such as hospitals and hotels. Time of use and cooling load profiles are significant factors that should be carefully considered either in chiller plant design or in chiller sequencing operation. This article aims to present an operation planning of HCP which consists of both electric and non-electric chillers. Four operational strategies are proposed and solved to compare their coefficients of performance and economics of running costs. A typical hotel building located on the Nile river in Egypt is selected to perform the current thermal and economic case study. The total cooling load profile of this hotel building is 4000 refrigeration tonnage (TR), which </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">is </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">simulated to optimize chiller sequence of operation and to select optimal design conditions of both numbers for electric and non-electric chillers used in HCP. The results of this comparative study for running cost are defined using various design configurations with different several chiller sequences available for each configuration. Then, the results of COPs, and operational running cost and initial cost are presented in this article also. The comparison aims to find the optimal design and operational sequencing for HCPs on thermal basis and economic analysis which were attached in this article. Recommendations and suggestions for future work are attached at the end of this article.</span></span></span> 展开更多
关键词 Hybrid chiller Plant Sustainability in Buildings AIR-CONDITIONING Hotel Building chiller Sequencing Building Cooling
下载PDF
An Energy and Exergy Analysis of a Microturbine CHP System
16
作者 B.M.A. Makhdoum B. Agnew 《Journal of Environmental Science and Engineering》 2011年第4期508-518,共11页
The micro-turbine is known as a producer of high-grade energy (work) and also low energy (heat). The following low grade heat energy have been modeled under ISO ambient conditions (international standard organiza... The micro-turbine is known as a producer of high-grade energy (work) and also low energy (heat). The following low grade heat energy have been modeled under ISO ambient conditions (international standard organization), i.e. 15 ℃ and 1 bar, to utilize the waste heat energy of a 200 kW micro-turbine combined with a single effect absorption chiller, an organic ranking cycle using R245fa (ORC-R245 fa) as a working fluid, a multi-effect distillation desalination (MED) and a thermal vapor compression MED Desalination unit (TVC-MED). The thermal comparison was carried out based on an energy and exergy analysis in terms of electric efficiency, exergetic efficiency, carbon footprint, and energy utilization factor (EUF). The software package IPSEpro has been used to model and simulate the proposed power plants. As a result, utilizing the exhaust waste heat energy in single-effect absorption chillier has contributed to stabilize ambient temperature fluctuation, and gain the best exergetic efficiency of 39%, while the EUF has reached 72% and the carbon footprint was reduced by 75% in MED and TVC-MED Desalination respectively. The results also reveal that TVC-MED is more efficient than traditional MED as its gain output ratio (GOR) is improved by 5.5%. In addition, ORC-245fa generates an additional 20% of the micro-turbine electricity generation. 展开更多
关键词 MICRO-TURBINE absorption chiller energy EXERGY ORC MED TVC-MED.
下载PDF
Evaluation of Performance of Thermal and Electrical Hybrid Adsorption Chiller Cycles with Mechanical Booster Pumps
17
作者 Tao Zeng Takehiro Esaki +2 位作者 Jun Li Noriyuki Kobayashi Hongyu Huang 《Journal of Materials Science and Chemical Engineering》 2017年第5期22-32,共11页
Large amounts of waste heat below 100oC from the industrial sector are re-leased into the atmosphere. It has been suggested that energy system efficiency can be increased with adsorption chillers. However, the cooling... Large amounts of waste heat below 100oC from the industrial sector are re-leased into the atmosphere. It has been suggested that energy system efficiency can be increased with adsorption chillers. However, the cooling power and coefficient of performance (COP) of conventional adsorption chillers significantly decrease with the desorption temperature. In this paper, we proposed a mechanical booster pump (MBP)-assisted adsorption chiller cycle, and evaluated its performances. In the cycle, a MBP was incorporated into a zeolite-water-type adsorption chiller for facilitating water vapor transportation between an adsorber and an evaporator/condenser. We have experimentally studied the effect of the input electrical power of MBP on the performances of adsorption chiller cycle. It has been demonstrated that the heat input achieved by using MBP at the desorption temperature of 50oC was 1.6 times higher than that of without MBP at the desorption temperature of 60oC. And the increase of pump power was found to be effective in increasing the heat input. Therefore, it was confirmed that the operation range of desorption temperature, which can be generated by using the waste heat, was extended and the cooling power was increased directly by using MBP. 展开更多
关键词 Adsorption chiller Cycle Zeolite/Water PAIR MECHANICAL BOOSTER PUMP
下载PDF
Optimization of Chiller Loading Problem Using Improved Golden Jackal Optimization Algorithm Leads to Reduction in Energy Consumption
18
作者 Na Dong Xiao Yang Nasser Yousefi 《Energy Engineering》 EI 2023年第11期2565-2583,共19页
This paper proposes a modified golden jackal optimization(IGJO)algorithm to solve the OCL(which stands for optimal cooling load)problem to minimize energy consumption.In this algorithm,many tools have been developed,s... This paper proposes a modified golden jackal optimization(IGJO)algorithm to solve the OCL(which stands for optimal cooling load)problem to minimize energy consumption.In this algorithm,many tools have been developed,such as numerical visualization,local field method,competitive selectionmethod,and iterative strategy.The IGJO algorithm is used to improve the research capabilities of the algorithm in terms of global tuning and rotation speed.In order to fully utilize the effectiveness of the proposed algorithm,three famous examples of OCL problems in basic ventilation systems were studied and compared with some previously published works.The results show that the IGJO algorithm can find solutions equal to or better than other methods.Underpinning these studies is the need to reduce energy consumption in air conditioning systems,which is a critical business and environmental decision.The Optimal Chiller Load(OCL)problem is well-known in the industry.It is the best method of operation for the refrigeration plant to satisfy the requirement of cooling.In order to solve the OCL problem,an improved Golden Jackal optimization algorithm(IGJO)was proposed.The IGJO algorithm consists of a number of parts to improve the global optimization and rotation speed.These studies are intended to address more effectively the issue of OCL,which results in energy savings in air-conditioning systems.The performance of the proposed IGJO algorithm is evaluated,and the results are compared with the results of three known OCL problems in the ventilation system.The results indicate that the IGJO method has the same or better optimization ability as other methods and can improve the energy efficiency of the system’s cold air. 展开更多
关键词 Optimal chiller loading improved version of golden jackal optimization energy consumption
下载PDF
Thermodynamic Analysis of Double Effect Absorption System along with Boiler and Cooling Tower
19
作者 Saeed Sedigh Hamid Saffari Hamidreza Taleshbahrami 《Journal of Environmental Science and Engineering(A)》 2012年第2期261-270,共10页
Many researchers have studied single and double effect absorption cycles based on first and second lows of thermodynamics But so far the relation of different parameters inside these cycles to the second law of thermo... Many researchers have studied single and double effect absorption cycles based on first and second lows of thermodynamics But so far the relation of different parameters inside these cycles to the second law of thermodynamics in boiler and cooling tower has not been investigated. In this paper, a system comprised of a series flow double effect water-Lithium bromide absorption chiller, a boiler and a cooling tower is studied based on the first and second laws of thermodynamics, and also exergy analysis is investigated. For this purpose, mass and energy conservation laws governing the system are written, and coefficient of performance of the system, exergy destruction (loss) of each component and exergy efficiency have been calculated. 展开更多
关键词 Absorption chiller thermodynamic analysis cooling tower.
下载PDF
Design of Industrial Water Cooled Chiller for Recycle Cyclohexane in Polyethylene Plant
20
作者 Jackson Gunorubon Akpa Kenneth Kekpugile Dagde Nsisong Basil Inyang 《Advances in Chemical Engineering and Science》 2019年第2期143-158,共16页
The research was aimed at providing water for cooling recycled cyclohexane in polyethylene plant to 15°C. This research could be redounding to the benefit of polyethylene plants that are using solution based poly... The research was aimed at providing water for cooling recycled cyclohexane in polyethylene plant to 15°C. This research could be redounding to the benefit of polyethylene plants that are using solution based polymerization technique. A chiller unit of 630 T, which has compressor power input of 378.33 kW and can provide chilled water capable of cooling recycle cyclohexane to 15°C, was designed using Aspen Hysys version 7.1. Four different refrigerants were tested to know the best fit refrigerant for the design and the best among them was R134a. The designed chiller has a coefficient of performance of 6.3 and a capacity greater than that of the defective chiller (550 TR). Unlike the defective chiller, with the increased cooling capacity and corresponding increase in compressor power from 296 kW to 378.6 kW, it could discharge chilled water capable of cooling recycle cyclohexane from 38°C to 15°C without tripping of the unit. With this design, ethylene absorption rate could increase to 40 T/h. Evaporator and condenser were designed and duties were 2166.39 KJ/sec and 2544.72 KJ/sec respectively. A thermostatic expansion valve with flow coefficient of 46.17 gpm was designed. The designed suction and discharge pressure were 414 kpa and 1053 kpa respectively while condenser temperature of 40°C was used for the design. The cooling of recycle cyclohexane from 38°C to 15°C using the chilled water supplied by the designed chiller was simulated using Aspen Hysys. 展开更多
关键词 chiller COMPRESSOR EVAPORATOR CONDENSER Expansion Valve
下载PDF
上一页 1 2 20 下一页 到第
使用帮助 返回顶部