An online method using continuous flow isotope ratio mass spectrometry (CF-IRMS) interfaced with a Gasbench Ⅱ was presented to determine chlorine stable isotope composition. Silver chloride (AgCl) was quantitativ...An online method using continuous flow isotope ratio mass spectrometry (CF-IRMS) interfaced with a Gasbench Ⅱ was presented to determine chlorine stable isotope composition. Silver chloride (AgCl) was quantitatively derived from chloride by using silver nitrate (AgNO3), and then was reacted with iodomethane (CH3Ⅰ) to produce methyl chloride (CH3Cl). A GasBench Ⅱ equipped with a PoraPlot Q column was used to separate CH3Cl from any other gas species. Finally, chlorine stable isotope analysis was carried out on CH3Cl introduced to the IRMS in a helium stream via an active open split. The minimum amount of Cl used in this method is of the order of 1.4 μmol. Inter-laboratory and inter-technique comparisons show that the total uncertainty incorporating both the precision and accuracy of this method is better than 0.007%. Furthermore, ten seawaters sampled from different locations have a narrow δ37Cl value range from -0.008% to 0.010%, with a mean value of (0.000±0.006)%. This supports the assumption that any seawater can be representative of standard mean ocean chloride (SMOC) and used as an international reference material.展开更多
In the process of bromine production,because of lag adjustment methods,there are problems of adjusting delay,raw material wastage and low growth rate.By considering the nature of bromine production,with the help of fu...In the process of bromine production,because of lag adjustment methods,there are problems of adjusting delay,raw material wastage and low growth rate.By considering the nature of bromine production,with the help of fuzzy data processing method,computer detection and display technique,we designed an automatic detection instrument for the ratio of chlorine to bromine in oxidized liquid of bromine production.This instrument can be used to detect the different parameters of raw materials adjustment and control in real time,and afford assurance that raw materials will be adjusted in time.This paper briefly introduces the working mechanism,hardware and software design of the instrument.展开更多
基金Projects(40772156, 41072179) supported by the National Natural Science Foundation of China
文摘An online method using continuous flow isotope ratio mass spectrometry (CF-IRMS) interfaced with a Gasbench Ⅱ was presented to determine chlorine stable isotope composition. Silver chloride (AgCl) was quantitatively derived from chloride by using silver nitrate (AgNO3), and then was reacted with iodomethane (CH3Ⅰ) to produce methyl chloride (CH3Cl). A GasBench Ⅱ equipped with a PoraPlot Q column was used to separate CH3Cl from any other gas species. Finally, chlorine stable isotope analysis was carried out on CH3Cl introduced to the IRMS in a helium stream via an active open split. The minimum amount of Cl used in this method is of the order of 1.4 μmol. Inter-laboratory and inter-technique comparisons show that the total uncertainty incorporating both the precision and accuracy of this method is better than 0.007%. Furthermore, ten seawaters sampled from different locations have a narrow δ37Cl value range from -0.008% to 0.010%, with a mean value of (0.000±0.006)%. This supports the assumption that any seawater can be representative of standard mean ocean chloride (SMOC) and used as an international reference material.
文摘In the process of bromine production,because of lag adjustment methods,there are problems of adjusting delay,raw material wastage and low growth rate.By considering the nature of bromine production,with the help of fuzzy data processing method,computer detection and display technique,we designed an automatic detection instrument for the ratio of chlorine to bromine in oxidized liquid of bromine production.This instrument can be used to detect the different parameters of raw materials adjustment and control in real time,and afford assurance that raw materials will be adjusted in time.This paper briefly introduces the working mechanism,hardware and software design of the instrument.