A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a secondgeneration ALK inhibit...A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a secondgeneration ALK inhibitor, in patient plasma and brain tumor tissue samples. Sample preparation involved simple protein precipitation with acetonitrile. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C_(18) column using a 4-min gradient elution consisting of mobile phase A(0.1% formic acid in water) and mobile phase B(0.1% formic acid in acetonitrile), at a flow rate of 0.4 m L/min. Ceritinib and the internal standard([^(13)C_6]ceritinib) were monitored using multiple reaction monitoring mode under positive electrospray ionization. The lower limit of quantitation(LLOQ) was 1 n M of ceritinib in plasma. The calibration curve was linear over ceritinib concentration range of 1–2000 n M in plasma. The intra-and interday precision and accuracy were within the generally accepted criteria for bioanalytical method( o15%).The method was successfully applied to assess ceritinib brain tumor penetration, as assessed by the unbound drug brain concentration to unbound drug plasma concentration ratio, in patients with brain tumors.展开更多
It is important to understand the mechanism and implications of different modifiers on analytical and preparative processes under chromatography with supercritical fluids (SFs) and under extraction with SFs. Supercrit...It is important to understand the mechanism and implications of different modifiers on analytical and preparative processes under chromatography with supercritical fluids (SFs) and under extraction with SFs. Supercritical fluid chromatography (SFC) and supercritical fluid extraction are generally carried out with neat supercritical carbon dioxide (SCCO2) or with SCCO2 containing modifiers (or cosolvents), especially for strongly polar compounds. For example, methanol is added as a cosolvent/modifier to SCCO2 for the extraction/separation of polar compounds. This paper discusses the influence of the modifier on the colligative properties of the principal mobile phase, which may define the situation in the total mobile phase in a chromatography column or in parts of a column under SFC. No colligative behavior of solutions reflects individual properties of the solutes. Their cross-interactions with solvents are discussed.展开更多
This study presents a fast, accurate and sensitive technique using gas chromatography-mass spectrometry (GC-MS) for the identification and quantification of N-acyl homoserine lactones (AHLs) in the extracts of bacteri...This study presents a fast, accurate and sensitive technique using gas chromatography-mass spectrometry (GC-MS) for the identification and quantification of N-acyl homoserine lactones (AHLs) in the extracts of bacterial strain of Pseudomonas aeruginosa and sputum sample of a cystic fibrosis patient. This method involves direct separation and determination of AHLs by using GC-MS as simultaneous separation and characterization of AHLs were possible without any prior derivatiza-tion. Electron ionization resulted in a common fragmentation pattern with the most common fragment ion at m/z 143 and other minor peaks at 73, 57 and 43. The limit of detection for N-butanoyl, N-hexanoyl, N-octanoyl, N-decanoyl, N-dodecanoyl and N-tetradecanoyl homoserine lactones was 2.14, 3.59, 2.71, 2.10, 2.45 and 2.34 μg/L, respectively. The presence of AHLs in the culture of P. aeruginosa strain and spu-tum of a cystic fibrosis patient was achieved in selected ion monitoring (SIM) mode by using the prominent fragment at m/z 143.展开更多
[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by ga...[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.展开更多
The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar co...The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar compounds.This study introduces an optimized twin-column recycling chromatography method for the efficient and simultaneous purification of these elusive constituents.By introducing water at a small flowing rate between the twin columns,a step solvent gradient is created,by which the leading edge of concentration band would migrate at a slower rate than the trailing edge as it flowing from the upstream to downstream column.Hence,the band broadening is counterbalanced,resulting in an enrichment effect for those minor components in separation process.Herein,two target substances,which showed similar peak position in high performance liquid chromatography(HPLC)and did not exceed 1.8%in crude paclitaxel were selected as target compounds for separation.By using the twin-column recycling chromatography with a step solvent gradient,a successful purification was achieved in getting the two with the purity almost 100%.We suggest this method is suitable for the separation of most components in natural produces,which shows higher precision and recovery rate compared with the common lab-operated separation ways for natural products(thin-layer chromatography and prep-HPLC).展开更多
A cationic gene delivery vector, guanidinylated disulfide-containing poly(amido amine)(CARCBA), was synthesized by Michael addition reaction between N,N′-cystaminebisacrylamide(CBA) and guanidine hydrochloride(CAR). ...A cationic gene delivery vector, guanidinylated disulfide-containing poly(amido amine)(CARCBA), was synthesized by Michael addition reaction between N,N′-cystaminebisacrylamide(CBA) and guanidine hydrochloride(CAR). Gel permeation chromatography(GPC) was used to evaluate the molecular weight of synthesized CAR-CBA. Polyethyleneimine(PEI) with molecular weight of 25 kDa was adopted as a reference, and polyethylene glycols(PEG) with different molecular weights were used to establish a standard curve for determining the molecular weight of CAR-CBA. The effects of two critical factors, namely columns and eluents,on the molecular weight measurement of CAR-CBA were investigated to optimize the GPC quantitative method. The results showed that Ultrahydrogel columns(120, 250) and HAc–NaAc(0.5 M, pH 4.5) buffer solution were the optimal column and GPC eluent, respectively.The molecular weight of the synthesized CAR-CBA was analyzed by the optimized GPC method and determined to be 24.66 kDa.展开更多
Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively...Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively inert, causing no irritation and allergies. Poly(ethylene oxide)(PEO) hydrogels were prepared using pentaerythritol tetra-acrylate(PETRA) as UV crosslinking agent. A simple, accurate, and robust quantitation method was developed based on gas chromatographic techniques(GC), which is suitable for routine analysis of residual PETRA monomers in these hydrogels. Unreacted PETRA was initially identified using gas chromatography–mass spectrometry(GC–MS). The quantitation of analyte was performed and validated using gas chromatography equipped with a flame ionization detector(GC–FID). A linear relationship was obtained over the range of 0.0002%–0.0450%(m/m) with a correlation coefficient(r2)greater than 0.99. The recovery( 4 90%), intra-day precision(%RSD o 0.67), inter-day precision(%RSD o2.5%), and robustness(%RSD o1.62%) of the method were within the acceptable values. The limit of detection(LOD) and limit of quantitation(LOQ) were 0.0001%(m/m) and 0.0002%(m/m), respectively.This assay provides a simple and quick way of screening for residual acrylate monomer in hydrogels.展开更多
Cation-exchange high-performance liquid chromatography(CE-HPLC) is a widely used laboratory test to detect variant hemoglobins as well as quantify hemoglobins F and A2 for the diagnosis of thalassemia syndromes. It...Cation-exchange high-performance liquid chromatography(CE-HPLC) is a widely used laboratory test to detect variant hemoglobins as well as quantify hemoglobins F and A2 for the diagnosis of thalassemia syndromes. It's versatility, speed, reproducibility and convenience have made CE-HPLC the method of choice to initially screen for hemoglobin disorders. Despite its popularity, several methodological aspects of the technology remain obscure to pathologists and this may have consequences in specific situations. This paper discusses the basic principles of the technique, the initial quality control steps and the interpretation of various controls and variables that are available on the instrument output. Subsequent sections are devoted to methodological considerations that arise during reporting of cases. For instance, common problems of misidentified peaks, totals crossing 100%, causes of total area being above or below acceptable limits and the importance of pre-integration region peaks are dealt with. Ultimately, CE-HPLC remains an investigation, the reporting of which combines in-depth knowledge of the biological basics with more than a working knowledge of the technological aspects of the technique.展开更多
In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Pr...In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Principle component analysis (PCA) of the profiling data was performed for pattern recognition, clearly showing that the proposed MS profiling method was able to classify Oriental Beauty tea into different grades. The component mass ions primarily responsible for the separation were selected with high loading strength in the PCA for subsequent identification with tandem mass (MS/MS). Caffeine, citrate and salicylate were verified, whereas certain other compounds remained ambiguous. Regression analysis considering caffeine, citrate and salicylate showed a linear relationship between the prices of the Oriental Beauty tea with an adjusted R2 of 0.84. If all the selected marker ions (in addition to caffeine, citrate and salicylate) could have been identified and incorporated into regression analysis, a stronger relationship could have been confirmed. These results suggest that metabolomics can facilitate the determination of real markers in the quality control of Oriental Beauty tea, and may lead to the further application of metabolomics in other food quality controls.展开更多
A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithe...A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithelantha micromeris. Purification of GA4 was carried out by solid phase extraction (SPE), in Epithelantha micromeris. In the chromatography method was obtaining a retention time of 2.1 min, using Hypersil GOLD C-18 column (100 × 4.6 mm dim and size particle 5 μ), mobile phase 50/50 acetonitrile/water and a flow 1.0 ml/min. Detection was carried out by a UV detector set at 205 nm, and a quantization limit of 0.4 mg/L. The obtained correlation coefficient was 0.995.展开更多
Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant propertie...Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant properties of Gymnema sylvestre extracts.Ethanolic reflux extraction followed by column chromatography was employed to isolate phenolic compounds.The total phenolic and flavonoid contents were quantified using the Folin–Ciocalteu and aluminum chloride colorimetric methods,respectively.Antioxidant activities were assessed by DPPH,ABTS scavenging assays and the ferric reducing antioxidant power(FRAP)assay.High-Performance Liquid Chromatography(HPLC)with a C18 column and Thermo TSQ Quantum Access Max(LC-MS)were used to determine the levels of gymnemic acid and identify other potential phenolic compounds.The analysis revealed significant antioxidant activities in the fractions.Fraction A showed the highest DPPH and ABTS scavenging activities,and Fraction C demonstrated the highest ferric reducing power.LC-MS analysis identified several phenolic compounds,indicating that these are major contributors to the antioxidant efficacy of the extract.This study provides a detailed phenolic profile and confirms the strong antioxidant potential of Gymnema sylvestre leaf extract,supporting its therapeutic use and further investigation.展开更多
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl...This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.展开更多
Activity coefficients at infinite dilution, γ ∞ i, were calculated for 12 solutes, with organic solutes including linear alcohols (methanol, ethanol, propanol), linear alkanes (heptane, octane), benzene, toluene, cy...Activity coefficients at infinite dilution, γ ∞ i, were calculated for 12 solutes, with organic solutes including linear alcohols (methanol, ethanol, propanol), linear alkanes (heptane, octane), benzene, toluene, cyclohexane, 1, 2-dichloroethane, trichloroethylene, acetonitrile and carbon tetrachloride. The values of γ ∞ i were determined via either thermodynamic or artificial neural network modelling at different temperatures. A comparison between extracted results from these two methods confirmed that experimental and predicted results are roughly the same. The accuracy of predicted results proves this model is fully compatible with a wide range of solutes, and it can readily be used as an alternative to conventional gas-liquid chromatography for the measurements of activity coefficient at infinite dilution.展开更多
Capillary chromatography using an untreated open tubular capillary tube and a ternary solvent mixture consisting of water-hydrophilic/hydrophobic organic solvent as a carrier solution has been developed. The system is...Capillary chromatography using an untreated open tubular capillary tube and a ternary solvent mixture consisting of water-hydrophilic/hydrophobic organic solvent as a carrier solution has been developed. The system is called tube radical distribution chromatography (TRDC). Separation performance of the TRDC system using a fused-silica capillary tube was examined through the phase diagram for the ternary water-acetonitrile-ethyl acetate solvent mixture. The TRDC system required homogeneous carrier solutions with solvent component ratios around the boundary curve between homogeneous and heterogeneous solution in the phase diagram. The data obtained using the fused-silica capillary tube were compared with those obtained using a polytetrafluoroethylene capillary tube in our previous study.展开更多
The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas ...The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas chroma- tography-mass spectrometry (GC-MS) detection. The pesticides were extracted with ultrasonic device and 5.0 mL mixture of ethyl acetate and cyclohexane (1:1, v/v). Coextractants from sample matrices which may have interfere to the qualitative and quantitative analysis, such as pigments, were removed using GPC purification. Simultaneous full scan and selective ion monitor (scan/SIM) mode for GC-MS was used for qualitative and quantitative analysis, which pro- vided retention time and characteristic fragments ratio for each pesticide so as to positively identify each analyte. Rela- tive standard deviations (RSDs) were within 7.7% (5.0 - 22.5 μg/kg, n = 3). The recoveries of pesticide standards at the spiked concentration of 5.0 - 22.5 μg/kg were between 87.1% and 110.9%. Limits of detection (LODs) for the analytes were 0.16 - 3.2 μg/kg, which could meet the demand of routine analysis and TCM quality control.展开更多
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first...To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).展开更多
[Objectives] To develop a method for separation and purification of acetophenones from Cynanchum bengei Decne root bark by combination of silica gel and high-speed counter-current chromatography( HSCCC). [Methods]The ...[Objectives] To develop a method for separation and purification of acetophenones from Cynanchum bengei Decne root bark by combination of silica gel and high-speed counter-current chromatography( HSCCC). [Methods]The crude extract of Cynanchum bengei Decne root bark was separated by silica gel column chromatography,and parts A and B containing acetophenones were obtained. Then,parts A and B were separated by HSCCC with a two-phase solvent system composed of petroleum ether-ethyl acetate-methanol-water( 4∶ 6∶ 4. 5∶ 5. 5 and4∶ 6 ∶ 3 ∶ 7, V/V), respectively. [Results] From 260 mg of part A, four compounds with p-dihydroxybenzene 3. 9 mg(Ⅰ),4-hydroxyacetophenone 17. 1 mg( Ⅱ),2,5-di-hydroxyacetophenone 13. 3 mg(Ⅲ) and 2,4-dihydroxyaceto-phenone 21. 0 mg(Ⅳ) were obtained. And from 300 mg of part B,136 mg of Radix Cynanchi Bungei benzophenone(Ⅴ) was obtained. The purity of compounds determined by HPLC was 97. 0%,96. 6%,99. 2%,99. 7%,99. 5%,respectively. [Conclusions] The established method is simple and efficient. It can be used for separation of acetophenones from Cynanchum bengei Decne root bark and has better practical value,which could provide a reference basis for development and utilization of Cynanchum bengei Decne root bark.展开更多
[Objectives] To better control the quality of Nuhuang Fuzheng Oral Liquid and study the main component Cuscuta chinensis Lam.by Thin Layer Chromatography. [Methods] Through changing the treatment methods of the test s...[Objectives] To better control the quality of Nuhuang Fuzheng Oral Liquid and study the main component Cuscuta chinensis Lam.by Thin Layer Chromatography. [Methods] Through changing the treatment methods of the test sample solution,proportion of the developing solvent and sample application volume,taking the spot resolution,definition,and Rf value,optimal Thin Layer Chromatography conditions were screened for Cuscuta chinensis Lam. [Results] After the test sample solution passing the neutral alumina column,it was extracted two times using the ethyl acetate. Methanol was added to dissolve. Benzene-ethyl acetate-formic acid( 5∶5∶2.5) was used as developing solvent.And ammonia fumigation was carried out to develop color. In the thin layer chromatograph obtained through these conditions,Nuhuang Fuzheng Oral Liquid test sample solution showed the same stripe in the same position of the control drug chromatogram and there was no obvious tailing phenomenon and the spot was clear. [Conclusions] The thin layer chromatography identification conditions can be used as the method for quality control of Cuscuta chinensis Lam. in Nuhuang Fuzheng Oral Liquid.展开更多
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established....A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.展开更多
Infant rice cereals were analyzed for total arsenic, inorganic arsenic (i-As) and the organic arsenic species monomethylarsonoic acid (MMA) and dimethylarsinic acid (DMA) using liquid chromatography inductively couple...Infant rice cereals were analyzed for total arsenic, inorganic arsenic (i-As) and the organic arsenic species monomethylarsonoic acid (MMA) and dimethylarsinic acid (DMA) using liquid chromatography inductively coupled plasma mass spectrometry (LC-ICP-MS). Total arsenic concentrations in the samples ranged from 110 ng/gup to 420 ng/g. The i-As in the rice cereals accounted for 33% to 77% of the total arsenic. The observed variability between infant rice cereals makes a dietary survey approach to accessing arsenic exposures difficult.展开更多
基金supported by the United States Public Health Service Cancer Center Support Grant P30 CA022453Novartis for providing the study drug and isotope-labeled internal standard and providing financial support for the clinical study
文摘A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a secondgeneration ALK inhibitor, in patient plasma and brain tumor tissue samples. Sample preparation involved simple protein precipitation with acetonitrile. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C_(18) column using a 4-min gradient elution consisting of mobile phase A(0.1% formic acid in water) and mobile phase B(0.1% formic acid in acetonitrile), at a flow rate of 0.4 m L/min. Ceritinib and the internal standard([^(13)C_6]ceritinib) were monitored using multiple reaction monitoring mode under positive electrospray ionization. The lower limit of quantitation(LLOQ) was 1 n M of ceritinib in plasma. The calibration curve was linear over ceritinib concentration range of 1–2000 n M in plasma. The intra-and interday precision and accuracy were within the generally accepted criteria for bioanalytical method( o15%).The method was successfully applied to assess ceritinib brain tumor penetration, as assessed by the unbound drug brain concentration to unbound drug plasma concentration ratio, in patients with brain tumors.
文摘It is important to understand the mechanism and implications of different modifiers on analytical and preparative processes under chromatography with supercritical fluids (SFs) and under extraction with SFs. Supercritical fluid chromatography (SFC) and supercritical fluid extraction are generally carried out with neat supercritical carbon dioxide (SCCO2) or with SCCO2 containing modifiers (or cosolvents), especially for strongly polar compounds. For example, methanol is added as a cosolvent/modifier to SCCO2 for the extraction/separation of polar compounds. This paper discusses the influence of the modifier on the colligative properties of the principal mobile phase, which may define the situation in the total mobile phase in a chromatography column or in parts of a column under SFC. No colligative behavior of solutions reflects individual properties of the solutes. Their cross-interactions with solvents are discussed.
文摘This study presents a fast, accurate and sensitive technique using gas chromatography-mass spectrometry (GC-MS) for the identification and quantification of N-acyl homoserine lactones (AHLs) in the extracts of bacterial strain of Pseudomonas aeruginosa and sputum sample of a cystic fibrosis patient. This method involves direct separation and determination of AHLs by using GC-MS as simultaneous separation and characterization of AHLs were possible without any prior derivatiza-tion. Electron ionization resulted in a common fragmentation pattern with the most common fragment ion at m/z 143 and other minor peaks at 73, 57 and 43. The limit of detection for N-butanoyl, N-hexanoyl, N-octanoyl, N-decanoyl, N-dodecanoyl and N-tetradecanoyl homoserine lactones was 2.14, 3.59, 2.71, 2.10, 2.45 and 2.34 μg/L, respectively. The presence of AHLs in the culture of P. aeruginosa strain and spu-tum of a cystic fibrosis patient was achieved in selected ion monitoring (SIM) mode by using the prominent fragment at m/z 143.
基金Supported by The Fourth Batch of High-end Talent Project in Hebei Province.
文摘[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.
基金supported by the National Natural Science Foundation of China(22078281)。
文摘The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar compounds.This study introduces an optimized twin-column recycling chromatography method for the efficient and simultaneous purification of these elusive constituents.By introducing water at a small flowing rate between the twin columns,a step solvent gradient is created,by which the leading edge of concentration band would migrate at a slower rate than the trailing edge as it flowing from the upstream to downstream column.Hence,the band broadening is counterbalanced,resulting in an enrichment effect for those minor components in separation process.Herein,two target substances,which showed similar peak position in high performance liquid chromatography(HPLC)and did not exceed 1.8%in crude paclitaxel were selected as target compounds for separation.By using the twin-column recycling chromatography with a step solvent gradient,a successful purification was achieved in getting the two with the purity almost 100%.We suggest this method is suitable for the separation of most components in natural produces,which shows higher precision and recovery rate compared with the common lab-operated separation ways for natural products(thin-layer chromatography and prep-HPLC).
基金the National Natural Science Foundation of China for financial support(No.81373335)
文摘A cationic gene delivery vector, guanidinylated disulfide-containing poly(amido amine)(CARCBA), was synthesized by Michael addition reaction between N,N′-cystaminebisacrylamide(CBA) and guanidine hydrochloride(CAR). Gel permeation chromatography(GPC) was used to evaluate the molecular weight of synthesized CAR-CBA. Polyethyleneimine(PEI) with molecular weight of 25 kDa was adopted as a reference, and polyethylene glycols(PEG) with different molecular weights were used to establish a standard curve for determining the molecular weight of CAR-CBA. The effects of two critical factors, namely columns and eluents,on the molecular weight measurement of CAR-CBA were investigated to optimize the GPC quantitative method. The results showed that Ultrahydrogel columns(120, 250) and HAc–NaAc(0.5 M, pH 4.5) buffer solution were the optimal column and GPC eluent, respectively.The molecular weight of the synthesized CAR-CBA was analyzed by the optimized GPC method and determined to be 24.66 kDa.
文摘Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively inert, causing no irritation and allergies. Poly(ethylene oxide)(PEO) hydrogels were prepared using pentaerythritol tetra-acrylate(PETRA) as UV crosslinking agent. A simple, accurate, and robust quantitation method was developed based on gas chromatographic techniques(GC), which is suitable for routine analysis of residual PETRA monomers in these hydrogels. Unreacted PETRA was initially identified using gas chromatography–mass spectrometry(GC–MS). The quantitation of analyte was performed and validated using gas chromatography equipped with a flame ionization detector(GC–FID). A linear relationship was obtained over the range of 0.0002%–0.0450%(m/m) with a correlation coefficient(r2)greater than 0.99. The recovery( 4 90%), intra-day precision(%RSD o 0.67), inter-day precision(%RSD o2.5%), and robustness(%RSD o1.62%) of the method were within the acceptable values. The limit of detection(LOD) and limit of quantitation(LOQ) were 0.0001%(m/m) and 0.0002%(m/m), respectively.This assay provides a simple and quick way of screening for residual acrylate monomer in hydrogels.
文摘Cation-exchange high-performance liquid chromatography(CE-HPLC) is a widely used laboratory test to detect variant hemoglobins as well as quantify hemoglobins F and A2 for the diagnosis of thalassemia syndromes. It's versatility, speed, reproducibility and convenience have made CE-HPLC the method of choice to initially screen for hemoglobin disorders. Despite its popularity, several methodological aspects of the technology remain obscure to pathologists and this may have consequences in specific situations. This paper discusses the basic principles of the technique, the initial quality control steps and the interpretation of various controls and variables that are available on the instrument output. Subsequent sections are devoted to methodological considerations that arise during reporting of cases. For instance, common problems of misidentified peaks, totals crossing 100%, causes of total area being above or below acceptable limits and the importance of pre-integration region peaks are dealt with. Ultimately, CE-HPLC remains an investigation, the reporting of which combines in-depth knowledge of the biological basics with more than a working knowledge of the technological aspects of the technique.
文摘In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Principle component analysis (PCA) of the profiling data was performed for pattern recognition, clearly showing that the proposed MS profiling method was able to classify Oriental Beauty tea into different grades. The component mass ions primarily responsible for the separation were selected with high loading strength in the PCA for subsequent identification with tandem mass (MS/MS). Caffeine, citrate and salicylate were verified, whereas certain other compounds remained ambiguous. Regression analysis considering caffeine, citrate and salicylate showed a linear relationship between the prices of the Oriental Beauty tea with an adjusted R2 of 0.84. If all the selected marker ions (in addition to caffeine, citrate and salicylate) could have been identified and incorporated into regression analysis, a stronger relationship could have been confirmed. These results suggest that metabolomics can facilitate the determination of real markers in the quality control of Oriental Beauty tea, and may lead to the further application of metabolomics in other food quality controls.
文摘A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithelantha micromeris. Purification of GA4 was carried out by solid phase extraction (SPE), in Epithelantha micromeris. In the chromatography method was obtaining a retention time of 2.1 min, using Hypersil GOLD C-18 column (100 × 4.6 mm dim and size particle 5 μ), mobile phase 50/50 acetonitrile/water and a flow 1.0 ml/min. Detection was carried out by a UV detector set at 205 nm, and a quantization limit of 0.4 mg/L. The obtained correlation coefficient was 0.995.
文摘Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant properties of Gymnema sylvestre extracts.Ethanolic reflux extraction followed by column chromatography was employed to isolate phenolic compounds.The total phenolic and flavonoid contents were quantified using the Folin–Ciocalteu and aluminum chloride colorimetric methods,respectively.Antioxidant activities were assessed by DPPH,ABTS scavenging assays and the ferric reducing antioxidant power(FRAP)assay.High-Performance Liquid Chromatography(HPLC)with a C18 column and Thermo TSQ Quantum Access Max(LC-MS)were used to determine the levels of gymnemic acid and identify other potential phenolic compounds.The analysis revealed significant antioxidant activities in the fractions.Fraction A showed the highest DPPH and ABTS scavenging activities,and Fraction C demonstrated the highest ferric reducing power.LC-MS analysis identified several phenolic compounds,indicating that these are major contributors to the antioxidant efficacy of the extract.This study provides a detailed phenolic profile and confirms the strong antioxidant potential of Gymnema sylvestre leaf extract,supporting its therapeutic use and further investigation.
文摘This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.
文摘Activity coefficients at infinite dilution, γ ∞ i, were calculated for 12 solutes, with organic solutes including linear alcohols (methanol, ethanol, propanol), linear alkanes (heptane, octane), benzene, toluene, cyclohexane, 1, 2-dichloroethane, trichloroethylene, acetonitrile and carbon tetrachloride. The values of γ ∞ i were determined via either thermodynamic or artificial neural network modelling at different temperatures. A comparison between extracted results from these two methods confirmed that experimental and predicted results are roughly the same. The accuracy of predicted results proves this model is fully compatible with a wide range of solutes, and it can readily be used as an alternative to conventional gas-liquid chromatography for the measurements of activity coefficient at infinite dilution.
文摘Capillary chromatography using an untreated open tubular capillary tube and a ternary solvent mixture consisting of water-hydrophilic/hydrophobic organic solvent as a carrier solution has been developed. The system is called tube radical distribution chromatography (TRDC). Separation performance of the TRDC system using a fused-silica capillary tube was examined through the phase diagram for the ternary water-acetonitrile-ethyl acetate solvent mixture. The TRDC system required homogeneous carrier solutions with solvent component ratios around the boundary curve between homogeneous and heterogeneous solution in the phase diagram. The data obtained using the fused-silica capillary tube were compared with those obtained using a polytetrafluoroethylene capillary tube in our previous study.
文摘The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas chroma- tography-mass spectrometry (GC-MS) detection. The pesticides were extracted with ultrasonic device and 5.0 mL mixture of ethyl acetate and cyclohexane (1:1, v/v). Coextractants from sample matrices which may have interfere to the qualitative and quantitative analysis, such as pigments, were removed using GPC purification. Simultaneous full scan and selective ion monitor (scan/SIM) mode for GC-MS was used for qualitative and quantitative analysis, which pro- vided retention time and characteristic fragments ratio for each pesticide so as to positively identify each analyte. Rela- tive standard deviations (RSDs) were within 7.7% (5.0 - 22.5 μg/kg, n = 3). The recoveries of pesticide standards at the spiked concentration of 5.0 - 22.5 μg/kg were between 87.1% and 110.9%. Limits of detection (LODs) for the analytes were 0.16 - 3.2 μg/kg, which could meet the demand of routine analysis and TCM quality control.
文摘To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).
基金Supported by National Natural Science Foundation Item of 2014(81373941)Shandong Natural Science Foundation Item of 2012(ZR2012HM047)+1 种基金Science and Technology Development Plan Item of Shandong(2014G2X219003)Major Project of the State Administration of Traditional Chinese Medicine(201407002)
文摘[Objectives] To develop a method for separation and purification of acetophenones from Cynanchum bengei Decne root bark by combination of silica gel and high-speed counter-current chromatography( HSCCC). [Methods]The crude extract of Cynanchum bengei Decne root bark was separated by silica gel column chromatography,and parts A and B containing acetophenones were obtained. Then,parts A and B were separated by HSCCC with a two-phase solvent system composed of petroleum ether-ethyl acetate-methanol-water( 4∶ 6∶ 4. 5∶ 5. 5 and4∶ 6 ∶ 3 ∶ 7, V/V), respectively. [Results] From 260 mg of part A, four compounds with p-dihydroxybenzene 3. 9 mg(Ⅰ),4-hydroxyacetophenone 17. 1 mg( Ⅱ),2,5-di-hydroxyacetophenone 13. 3 mg(Ⅲ) and 2,4-dihydroxyaceto-phenone 21. 0 mg(Ⅳ) were obtained. And from 300 mg of part B,136 mg of Radix Cynanchi Bungei benzophenone(Ⅴ) was obtained. The purity of compounds determined by HPLC was 97. 0%,96. 6%,99. 2%,99. 7%,99. 5%,respectively. [Conclusions] The established method is simple and efficient. It can be used for separation of acetophenones from Cynanchum bengei Decne root bark and has better practical value,which could provide a reference basis for development and utilization of Cynanchum bengei Decne root bark.
基金Supported by Clinical Study and New Veterinary Drug Declaration of Lianmei Zhili Powder and Nuhuang Granule(17403)
文摘[Objectives] To better control the quality of Nuhuang Fuzheng Oral Liquid and study the main component Cuscuta chinensis Lam.by Thin Layer Chromatography. [Methods] Through changing the treatment methods of the test sample solution,proportion of the developing solvent and sample application volume,taking the spot resolution,definition,and Rf value,optimal Thin Layer Chromatography conditions were screened for Cuscuta chinensis Lam. [Results] After the test sample solution passing the neutral alumina column,it was extracted two times using the ethyl acetate. Methanol was added to dissolve. Benzene-ethyl acetate-formic acid( 5∶5∶2.5) was used as developing solvent.And ammonia fumigation was carried out to develop color. In the thin layer chromatograph obtained through these conditions,Nuhuang Fuzheng Oral Liquid test sample solution showed the same stripe in the same position of the control drug chromatogram and there was no obvious tailing phenomenon and the spot was clear. [Conclusions] The thin layer chromatography identification conditions can be used as the method for quality control of Cuscuta chinensis Lam. in Nuhuang Fuzheng Oral Liquid.
文摘A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.
文摘Infant rice cereals were analyzed for total arsenic, inorganic arsenic (i-As) and the organic arsenic species monomethylarsonoic acid (MMA) and dimethylarsinic acid (DMA) using liquid chromatography inductively coupled plasma mass spectrometry (LC-ICP-MS). Total arsenic concentrations in the samples ranged from 110 ng/gup to 420 ng/g. The i-As in the rice cereals accounted for 33% to 77% of the total arsenic. The observed variability between infant rice cereals makes a dietary survey approach to accessing arsenic exposures difficult.