In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc...In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.展开更多
The novel pulsed liquid chromatography radionuclide separation method presented here provides a new and promising strategy for the extraction of uranium from seawater.In this study,a new chromatographic separation met...The novel pulsed liquid chromatography radionuclide separation method presented here provides a new and promising strategy for the extraction of uranium from seawater.In this study,a new chromatographic separation method was proposed,and a pulsed nuclide automated separation device was developed,alongside a new chromatographic column.The length of this chromatographic column was 10 m,with an internal warp of 3 mm and a packing size of 1 mm,while the total separation units of the column reached 12,250.The most favorable conditions for the separation of nuclides were then obtained through optimizing the separation conditions of the device:Sample pH in the column=2,sample injection flow rate=5.698 mL/min,chromatographic column heating temperature=60℃.Separation experiments were also carried out for uranium,europium,and sodium ions in mixed solutions;uranium and sodium ions in water samples from the Ganjiang River;and uranium,sodium,and magnesium ions from seawater samples.The separation factors between the different nuclei were then calculated based on the experimental data,and a formula for the separation level was derived.The experimental results showed that the separation factor in the mixed solution of uranium and europium(1:1)was 1.088,while achieving the initial separation of uranium and europium theoretically required a 47-stage separation.Considering the separation factor of 1.50for the uranium and sodium ions in water samples from the Ganjiang River,achieving the initial separation of uranium and sodium ions would have theoretically required at least a 21-stage separation.Furthermore,for the seawater sample separation experiments,the separation factor of uranium and sodium ions was 1.2885;therefore,more than 28 stages of sample separation would be required to achieve uranium extraction from seawater.The novel pulsed liquid chromatography method proposed in this study was innovative in terms of uranium separation and enrichment,while expanding the possibilities of extracting uranium from seawater through chromatography.展开更多
The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, a...The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R<sup>2</sup>> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection.展开更多
[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-g...[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-glucuronidase and extracted with 5%acetic acid-acetonitrile(1:99,V/V)solution.An Eclipse plus C 18 column was used for separation,and the MRM mode was used for qualitative analysis,and the external standard method was used for quantitative analysis of matrix standard solutions.[Results]Under the optimal conditions,the retention time of the 14 kinds ofβ-receptor agonists ranged from 1.0 to 9.5 min.When the mass concentration was in the range of 0.05-0.50μg/ml,the linear relationship ofβ-receptor agonists was good,with correlation coefficients(r)≥0.9992.The detection limits of the method were in the range of 0.04-0.87μg/kg,and the quantitative limits were in the range of 0.35-1.86μg/kg.The average recovery values were in the range of 82.8%-108.9%,with RSDs(n=6)in the range of 1.9%-6.7%.[Conclusions]The method is simple,sensitive,reproducible,accurate,and can be used for simultaneous determination of the 14 kinds ofβ-receptor agonist residues in mutton.展开更多
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte...An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.展开更多
Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 co...Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine.展开更多
[Objectives]This study was conducted to establish a rapid and effective method for simultaneous extraction of 54 kinds of veterinary drug residues in animal-derived food, including sulfonamides, quinolones, tetracycli...[Objectives]This study was conducted to establish a rapid and effective method for simultaneous extraction of 54 kinds of veterinary drug residues in animal-derived food, including sulfonamides, quinolones, tetracyclines, malachite greens, penicillins, nitroimidazoles, tranquilizers and macrolides, by HPLC-MS. [Methods] The samples were extracted with 80% acetonitrile water(containing 0.1% formic acid), combined with QuEChERS extraction technology and C18 and PSA purification, analyzed by high performance liquid chromatography-mass spectrometry, and quantified by external standard method. The target substances were analyzed on ZORBAX Eclipse C18 chromatographic column using 0.2% formic acid water and 0.2% methanol as mobile phases. The gradient elution mode was used for chromatographic separation and multiple reaction detection. [Results] In the linear range of 0.5-50.0 ng/ml, the linear relationship of the 54 kinds of veterinary drug residues was good, with correlation coefficients(r~2) greater than 0.995, and the detection limits ranged from 0.30 to 1.00 μg/kg. The results showed that the recovery ranged from 75.4% to 118.2% when different matrixes were added for recovery. [Conclusions] This method is simple, efficient, accurate, stable, and highly operable. It is applicable to simultaneous batch screening of veterinary drug residues in animal-derived food, and has high practical application value.展开更多
A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with flucona...A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM.展开更多
The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLD...The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLDTDYK,FFVAPFPEVFGK,and NAVPITPTLNR were confirmed and synthesized as the quantitative peptide of ovalbumin,α-lactalbumin,β-lactoglobulin,α_(S1)-casein andα_(S2)-casein,the relative isotope-labeled internal standards were used in the quantitative analysis.Linear range was in the range of0.5-5000.0 nmol/L for egg and milk allergen in bread,cake,cookie,rice crust and wheat flour samples with free from egg and milk,the limits of detection of milk allergens and egg allergen were in the range between0.94 mg/100 g and 56.71 mg/100 g,limits of quantification of milk allergens and egg allergen were in the range between 2.36 mg/100 g and 141.78 mg/100 g.The recoveries ranged from 76.7%to 122.8%,the relative standard deviations were in the range of 1.60%-15.60%.The developed method has been successfully used for the detection of egg and milk allergen in various food samples.展开更多
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ...A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.展开更多
A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid ...A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid chromatography-ultraviolet detector (HPLC-UV). All important variables influencing the extraction efficiency, such as pH, types of the extraction solvent and the disperser solvent and their volume, ionic strength and centrifugation time were investigated and optimized. Under the optimal conditions, the limit of detection (LODs) and quantification (LOQs) of the method were 13 and 39 ng/mL for CLZ, and 2 and 6 ng/mL for CPZ, respectively. The relative standard deviations (RSDs) of the targets were less than 5.1% (C=0.100 μg/mL, n=9). Good linear behaviors over the tested concentration ranges were obtained with the values of R20.999 for the targets. The absolute extraction efficiencies of CLZ and CPZ from the spiked blank urine samples were 98.3% and 97.8%, respectively. The applicability of the technique was validated by analyzing urine samples and the mean recoveries for spiked urine samples ranged from 93.3% to 105.0%. The method was successfully applied for the determination of CLZ and CPZ in real human urine.展开更多
Chromatography fingerprint (CFP) of 10 samples of hongqi were studied. 23 common peaks were analyzed, their average similarity was 97.29%. CFP were positioned with main index composition such as formononetin, calyco...Chromatography fingerprint (CFP) of 10 samples of hongqi were studied. 23 common peaks were analyzed, their average similarity was 97.29%. CFP were positioned with main index composition such as formononetin, calycosin and then the contents of index composition were determined. The character and exclusive of CFP of 10 samples of hongqi were clear. CFP and content determination of index composition of hongqi could be used to evaluate the quality of hongqi comprehensively.展开更多
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de...A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.展开更多
A high-performance liquid chromatography coupled ultraviolet (HPLC-UV) method was developed for a chemical fingerprint analysis of Viscum coloratura. Eighteen peaks were selected as the common peaks and Homoeriodict...A high-performance liquid chromatography coupled ultraviolet (HPLC-UV) method was developed for a chemical fingerprint analysis of Viscum coloratura. Eighteen peaks were selected as the common peaks and Homoeriodictyol-7-O-β-D-apiosiyl-(1→2)-β-D-glucoside was used as a reference. The relative areas of common peaks were used for hierarchical clustering analysis and similarity calculation. Thirty-seven samples collected from different sources were classified into five groups. The similarities of 21 batches Viscum coloratura samples were beyond 0.90. The results obtained suggest that the chromatographic fingerprint can efficiently identify Viscum coloratum. Additionally, the fingerprints can then be used to evaluate the correlation between Viscum coloratura and hosts.展开更多
A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxyte...A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites.展开更多
Creatinine, uric acid, hypoxanthine and xanthine are important diagnostic biomarkers in human urine for gouty arthritis or renal disease diacrisis. A simple method for simultaneous determination of these biomarkers in...Creatinine, uric acid, hypoxanthine and xanthine are important diagnostic biomarkers in human urine for gouty arthritis or renal disease diacrisis. A simple method for simultaneous determination of these biomarkers in urine based on reversed-phase high-performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was proposed. After pretreatment by dilution, centrifugation and filtration, the biomarkers in urine samples were separated by ODS-BP column by elution with methanol/50 mM NaH2PO4 buffer solution at pH 5.26 (5:95). Good linearity between peak areas and concentrations of standards was obtained for the biomarkers with correlation coefficients in the range of 0.9957-0.9993. The proposed analytical method has satisfactory repeatability (the recovery of data in a range of creatinine, uric acid, hypoxanthine and xanthine was 93.49-97.90%, 95.38-96.45%, 112.46-115.78%and 90.82-97.13%with standard deviation of o5%, respectively) and the limits of detection (LODs, S/N Z 3) for creatinine, uric acid, hypoxanthine, and xanthine were 0.010, 0.025, 0.050 and 0.025 mg/L, respectively. The established method was proved to be simple, accurate, sensitive and reliable for the quantitation of gouty arthritis' biomarkers in human urine samples. The ratio of creatinine to uric acid was found to be a possible factor for assessment of gouty arthritis.展开更多
Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensi...Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensional liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(2 D-LC/IM-QTOF-MS)enabling four-dimensional separations(2 D-LC,IM,and MS),is proposed.In combination with in-house database-driven automated peak annotation,this strategy was utilized to characterize ginsenosides simultaneously from white ginseng(WG)and red ginseng(RG).An offline 2 DLC system configuring an Xbridge Amide column and an HSS T3 column showed orthogonality 0.76 in the resolution of ginsenosides.Ginsenoside analysis was performed by data-independent high-definition MSE(HDMSE)in the negative ESI mode on a Vion?IMS-QTOF hybrid high-resolution mass spectrometer,which could better resolve ginsenosides than MSEand directly give the CCS information.An in-house ginsenoside database recording 504 known ginsenosides and 58 reference compounds,was established to assist the identification of ginsenosides.Streamlined workflows,by applying UNIFI?to automatedly annotate the HDMSEdata,were proposed.We could separate and characterize 323 ginsenosides(including 286 from WG and 306 from RG),and 125 thereof may have not been isolated from the Panax genus.The established 2 D-LC/IM-QTOF-HDMSEapproach could also act as a magnifier to probe differentiated components between WG and RG.Compared with conventional approaches,this dimensionenhanced strategy could better resolve coeluting herbal components and more efficiently,more reliably identify the multicomponents,which,we believe,offers more possibilities for the systematic exposure and confirmative identification of plant metabolites.展开更多
HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns, symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile ph...HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns, symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE. Experimental conditions: column: Hypersil BDS C18,5mm×4×250 mm; column temperature: 35C; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm.展开更多
The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this st...The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this study,a hexaalkylguanidinium ionic liquid(DOTMG-NTf;) was synthesized and coated statically onto capillary columns.Selectivity of the stationary phase was evaluated by separating Grob test mixture,test mixture,alcohols mixture,and fatty acid methyl esters mixture,and thermal stability was investigated as well.The present study demonstrates that GBILs as CGC stationary phases exhibit satisfactory selectivity and thermal stability and have a great potential as new candidates for CGC stationary phases.展开更多
A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane ...A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane (PMHS-[VHIm][PF6]) was synthe- sized, characterized and coated onto capillary columns by static coating. The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks. The present work suggests that novel stationary phase has a great potential for further development and application. 2009 Mei Ling Qi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.展开更多
文摘In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.
基金the Natural Science Foundation of Jiangxi Province,China(No.20202BABL203004)the Opening Project of the State Key Laboratory of Nuclear Resources and Environment(East China University of Technology)(No.2022NRE23)the Opening Project of Jiangxi Province Key Laboratory of Polymer Micro/Nano Manufacturing and Devices(No.PMND202101).
文摘The novel pulsed liquid chromatography radionuclide separation method presented here provides a new and promising strategy for the extraction of uranium from seawater.In this study,a new chromatographic separation method was proposed,and a pulsed nuclide automated separation device was developed,alongside a new chromatographic column.The length of this chromatographic column was 10 m,with an internal warp of 3 mm and a packing size of 1 mm,while the total separation units of the column reached 12,250.The most favorable conditions for the separation of nuclides were then obtained through optimizing the separation conditions of the device:Sample pH in the column=2,sample injection flow rate=5.698 mL/min,chromatographic column heating temperature=60℃.Separation experiments were also carried out for uranium,europium,and sodium ions in mixed solutions;uranium and sodium ions in water samples from the Ganjiang River;and uranium,sodium,and magnesium ions from seawater samples.The separation factors between the different nuclei were then calculated based on the experimental data,and a formula for the separation level was derived.The experimental results showed that the separation factor in the mixed solution of uranium and europium(1:1)was 1.088,while achieving the initial separation of uranium and europium theoretically required a 47-stage separation.Considering the separation factor of 1.50for the uranium and sodium ions in water samples from the Ganjiang River,achieving the initial separation of uranium and sodium ions would have theoretically required at least a 21-stage separation.Furthermore,for the seawater sample separation experiments,the separation factor of uranium and sodium ions was 1.2885;therefore,more than 28 stages of sample separation would be required to achieve uranium extraction from seawater.The novel pulsed liquid chromatography method proposed in this study was innovative in terms of uranium separation and enrichment,while expanding the possibilities of extracting uranium from seawater through chromatography.
文摘The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R<sup>2</sup>> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection.
基金Supported by The Fourth Batch of High-end Talent Project in Hebei ProvinceTangshan Science and Technology Entrepreneurship and Innovation Leading Talent Project(21130243A).
文摘[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-glucuronidase and extracted with 5%acetic acid-acetonitrile(1:99,V/V)solution.An Eclipse plus C 18 column was used for separation,and the MRM mode was used for qualitative analysis,and the external standard method was used for quantitative analysis of matrix standard solutions.[Results]Under the optimal conditions,the retention time of the 14 kinds ofβ-receptor agonists ranged from 1.0 to 9.5 min.When the mass concentration was in the range of 0.05-0.50μg/ml,the linear relationship ofβ-receptor agonists was good,with correlation coefficients(r)≥0.9992.The detection limits of the method were in the range of 0.04-0.87μg/kg,and the quantitative limits were in the range of 0.35-1.86μg/kg.The average recovery values were in the range of 82.8%-108.9%,with RSDs(n=6)in the range of 1.9%-6.7%.[Conclusions]The method is simple,sensitive,reproducible,accurate,and can be used for simultaneous determination of the 14 kinds ofβ-receptor agonist residues in mutton.
文摘An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.
文摘Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine.
文摘[Objectives]This study was conducted to establish a rapid and effective method for simultaneous extraction of 54 kinds of veterinary drug residues in animal-derived food, including sulfonamides, quinolones, tetracyclines, malachite greens, penicillins, nitroimidazoles, tranquilizers and macrolides, by HPLC-MS. [Methods] The samples were extracted with 80% acetonitrile water(containing 0.1% formic acid), combined with QuEChERS extraction technology and C18 and PSA purification, analyzed by high performance liquid chromatography-mass spectrometry, and quantified by external standard method. The target substances were analyzed on ZORBAX Eclipse C18 chromatographic column using 0.2% formic acid water and 0.2% methanol as mobile phases. The gradient elution mode was used for chromatographic separation and multiple reaction detection. [Results] In the linear range of 0.5-50.0 ng/ml, the linear relationship of the 54 kinds of veterinary drug residues was good, with correlation coefficients(r~2) greater than 0.995, and the detection limits ranged from 0.30 to 1.00 μg/kg. The results showed that the recovery ranged from 75.4% to 118.2% when different matrixes were added for recovery. [Conclusions] This method is simple, efficient, accurate, stable, and highly operable. It is applicable to simultaneous batch screening of veterinary drug residues in animal-derived food, and has high practical application value.
文摘A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM.
基金supported by National Key Research and Development Program of China(2019YFC1606400)Science and Technology Project of State Administration for Market Regulation(2021MK023)+1 种基金Hebei Province High-level Talent Funding Program(A201901008)Research Project of Hebei Administration for Market Regulation(2020ZD12)。
文摘The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLDTDYK,FFVAPFPEVFGK,and NAVPITPTLNR were confirmed and synthesized as the quantitative peptide of ovalbumin,α-lactalbumin,β-lactoglobulin,α_(S1)-casein andα_(S2)-casein,the relative isotope-labeled internal standards were used in the quantitative analysis.Linear range was in the range of0.5-5000.0 nmol/L for egg and milk allergen in bread,cake,cookie,rice crust and wheat flour samples with free from egg and milk,the limits of detection of milk allergens and egg allergen were in the range between0.94 mg/100 g and 56.71 mg/100 g,limits of quantification of milk allergens and egg allergen were in the range between 2.36 mg/100 g and 141.78 mg/100 g.The recoveries ranged from 76.7%to 122.8%,the relative standard deviations were in the range of 1.60%-15.60%.The developed method has been successfully used for the detection of egg and milk allergen in various food samples.
基金supported both by the Natural Science Foundations of Hebei(No.B2008000210)the Scientific Research Foundation of Agricultural University of Hebei.
文摘A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.
基金supported by Science Research Funds of Medical Course, HUST
文摘A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid chromatography-ultraviolet detector (HPLC-UV). All important variables influencing the extraction efficiency, such as pH, types of the extraction solvent and the disperser solvent and their volume, ionic strength and centrifugation time were investigated and optimized. Under the optimal conditions, the limit of detection (LODs) and quantification (LOQs) of the method were 13 and 39 ng/mL for CLZ, and 2 and 6 ng/mL for CPZ, respectively. The relative standard deviations (RSDs) of the targets were less than 5.1% (C=0.100 μg/mL, n=9). Good linear behaviors over the tested concentration ranges were obtained with the values of R20.999 for the targets. The absolute extraction efficiencies of CLZ and CPZ from the spiked blank urine samples were 98.3% and 97.8%, respectively. The applicability of the technique was validated by analyzing urine samples and the mean recoveries for spiked urine samples ranged from 93.3% to 105.0%. The method was successfully applied for the determination of CLZ and CPZ in real human urine.
文摘Chromatography fingerprint (CFP) of 10 samples of hongqi were studied. 23 common peaks were analyzed, their average similarity was 97.29%. CFP were positioned with main index composition such as formononetin, calycosin and then the contents of index composition were determined. The character and exclusive of CFP of 10 samples of hongqi were clear. CFP and content determination of index composition of hongqi could be used to evaluate the quality of hongqi comprehensively.
基金This research was supported by Special Research Fund for Young Doctors of Qiqihar Medical University(QMSI2020B-03,hosted by Wenjing Li).
文摘A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.
基金supported by the National NaturalScience Foundation of China(No.30901967)the Scientific Research Foundation for the Doctors of the Liaoning Provincial Department of Science and Technology(No.20091078)the Science and Technology Research Projects of the Educational Commission of Liaoning Province(No.2009A684)for financial support
文摘A high-performance liquid chromatography coupled ultraviolet (HPLC-UV) method was developed for a chemical fingerprint analysis of Viscum coloratura. Eighteen peaks were selected as the common peaks and Homoeriodictyol-7-O-β-D-apiosiyl-(1→2)-β-D-glucoside was used as a reference. The relative areas of common peaks were used for hierarchical clustering analysis and similarity calculation. Thirty-seven samples collected from different sources were classified into five groups. The similarities of 21 batches Viscum coloratura samples were beyond 0.90. The results obtained suggest that the chromatographic fingerprint can efficiently identify Viscum coloratum. Additionally, the fingerprints can then be used to evaluate the correlation between Viscum coloratura and hosts.
文摘A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites.
基金supported by the National Natural Science Foundation of China(No.21275088)
文摘Creatinine, uric acid, hypoxanthine and xanthine are important diagnostic biomarkers in human urine for gouty arthritis or renal disease diacrisis. A simple method for simultaneous determination of these biomarkers in urine based on reversed-phase high-performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was proposed. After pretreatment by dilution, centrifugation and filtration, the biomarkers in urine samples were separated by ODS-BP column by elution with methanol/50 mM NaH2PO4 buffer solution at pH 5.26 (5:95). Good linearity between peak areas and concentrations of standards was obtained for the biomarkers with correlation coefficients in the range of 0.9957-0.9993. The proposed analytical method has satisfactory repeatability (the recovery of data in a range of creatinine, uric acid, hypoxanthine and xanthine was 93.49-97.90%, 95.38-96.45%, 112.46-115.78%and 90.82-97.13%with standard deviation of o5%, respectively) and the limits of detection (LODs, S/N Z 3) for creatinine, uric acid, hypoxanthine, and xanthine were 0.010, 0.025, 0.050 and 0.025 mg/L, respectively. The established method was proved to be simple, accurate, sensitive and reliable for the quantitation of gouty arthritis' biomarkers in human urine samples. The ratio of creatinine to uric acid was found to be a possible factor for assessment of gouty arthritis.
基金the National Natural Science Foundation of China(Grant No.81872996)the State Key Research and Development Project(Grant No.2017YFC1702104)+1 种基金the State Key Project for the Creation of Major New Drugs(2018ZX09711001-009-010)the Tianjin Municipal Education Commission Research Project(Grant No.2017ZD07)。
文摘Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensional liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(2 D-LC/IM-QTOF-MS)enabling four-dimensional separations(2 D-LC,IM,and MS),is proposed.In combination with in-house database-driven automated peak annotation,this strategy was utilized to characterize ginsenosides simultaneously from white ginseng(WG)and red ginseng(RG).An offline 2 DLC system configuring an Xbridge Amide column and an HSS T3 column showed orthogonality 0.76 in the resolution of ginsenosides.Ginsenoside analysis was performed by data-independent high-definition MSE(HDMSE)in the negative ESI mode on a Vion?IMS-QTOF hybrid high-resolution mass spectrometer,which could better resolve ginsenosides than MSEand directly give the CCS information.An in-house ginsenoside database recording 504 known ginsenosides and 58 reference compounds,was established to assist the identification of ginsenosides.Streamlined workflows,by applying UNIFI?to automatedly annotate the HDMSEdata,were proposed.We could separate and characterize 323 ginsenosides(including 286 from WG and 306 from RG),and 125 thereof may have not been isolated from the Panax genus.The established 2 D-LC/IM-QTOF-HDMSEapproach could also act as a magnifier to probe differentiated components between WG and RG.Compared with conventional approaches,this dimensionenhanced strategy could better resolve coeluting herbal components and more efficiently,more reliably identify the multicomponents,which,we believe,offers more possibilities for the systematic exposure and confirmative identification of plant metabolites.
文摘HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns, symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE. Experimental conditions: column: Hypersil BDS C18,5mm×4×250 mm; column temperature: 35C; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm.
基金the National Nature Science Foundation of China(No.20675007)
文摘The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this study,a hexaalkylguanidinium ionic liquid(DOTMG-NTf;) was synthesized and coated statically onto capillary columns.Selectivity of the stationary phase was evaluated by separating Grob test mixture,test mixture,alcohols mixture,and fatty acid methyl esters mixture,and thermal stability was investigated as well.The present study demonstrates that GBILs as CGC stationary phases exhibit satisfactory selectivity and thermal stability and have a great potential as new candidates for CGC stationary phases.
基金the National Natural Science Foundation of China for the funding(No.20675007)
文摘A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane (PMHS-[VHIm][PF6]) was synthe- sized, characterized and coated onto capillary columns by static coating. The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks. The present work suggests that novel stationary phase has a great potential for further development and application. 2009 Mei Ling Qi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.