A convenient approach is proposed for analyzing the ultimate load carrying capacity of concrete filled steel tubular (CFST) arch bridge with stiffening girders. A fiber model beam element is specially used to simulate...A convenient approach is proposed for analyzing the ultimate load carrying capacity of concrete filled steel tubular (CFST) arch bridge with stiffening girders. A fiber model beam element is specially used to simulate the stiffening girder and CFST arch rib. The geometric nonlinearity, material nonlinearity, influence of the construction process and the contribution of prestressing reinforcement are all taken into consideration. The accuracy of this method is validated by comparing its results with experimental results. Finally, the ultimate strength of an abnormal CFST arch bridge with stiffening girders is investigated and the effect of construction method is discussed. It is concluded that the construction process has little effect on the ultimate strength of the bridge.展开更多
The calculation of ultimate bearing capacity is a significant issue in the design of Concrete Filled Steel Tubular (CFST) arch bridges. Based on the space beam theory, this paper provides a calculation method for dete...The calculation of ultimate bearing capacity is a significant issue in the design of Concrete Filled Steel Tubular (CFST) arch bridges. Based on the space beam theory, this paper provides a calculation method for determining the ultimate strength of CFST structures. The accuracy of this method and the applicability of the stress-strain relationships were validated by comparing different existing confined concrete uniaxial constitutive relationships and experimental results. Comparison of these results indicated that this method using the confined concrete uniaxial stress-strain relationships can be used to calculate the ultimate strength and CFST behavior with satisfactory accuracy. The calculation results are stable and seldom affected by concrete con-stitutive relationships. The method is therefore valuable in the practice of engineering design. Finally, the ultimate strength of an arch bridge with span of 330 m was investigated by the proposed method and the nonlinear behavior was discussed.展开更多
The simplified algorithm for out-of-plane ultimate loadcarrying capacity of concrete-filled steel tubular( CFST) solid-rib arches under uniform vertical load was studied. The experimentally validated finite element mo...The simplified algorithm for out-of-plane ultimate loadcarrying capacity of concrete-filled steel tubular( CFST) solid-rib arches under uniform vertical load was studied. The experimentally validated finite element model was developed. The out-of-plane equivalent length coefficients of solid-rib arches were obtained using out-of-plane elastic eigenvalue buckling analysis. Then the out-ofplane elastic stability coefficient was plotted against the normalized slenderness ratio,and the out-of-plane eigenvalue buckling load or elastic buckling capability of arches was calculated. Lastly effects of different parameters on the out-of-plane ultimate load-carrying capacity of CFST solid-rib arches were determined using geometric and material nonlinear finite element analysis, and a simplified algorithm was established by fitting the out-of-plane elastic-plastic stability coefficient and normalized slenderness ratio using PerryRobertson formula. Ratio of the elastic stability coefficient to the elastic-plastic counterpart was plotted against the out-of-plane normalized slenderness ratio,from which the out-of-plane elasticplastic ultimate load-carrying capacity was determined according to the corresponding elastic buckling load. Results show that the proposed simplified algorithm can accurately predict the out-of-plane eigenvalue buckling load and the elastic-plastic ultimate loadcarrying capacity of the CFST solid-rib arches.展开更多
文摘A convenient approach is proposed for analyzing the ultimate load carrying capacity of concrete filled steel tubular (CFST) arch bridge with stiffening girders. A fiber model beam element is specially used to simulate the stiffening girder and CFST arch rib. The geometric nonlinearity, material nonlinearity, influence of the construction process and the contribution of prestressing reinforcement are all taken into consideration. The accuracy of this method is validated by comparing its results with experimental results. Finally, the ultimate strength of an abnormal CFST arch bridge with stiffening girders is investigated and the effect of construction method is discussed. It is concluded that the construction process has little effect on the ultimate strength of the bridge.
文摘The calculation of ultimate bearing capacity is a significant issue in the design of Concrete Filled Steel Tubular (CFST) arch bridges. Based on the space beam theory, this paper provides a calculation method for determining the ultimate strength of CFST structures. The accuracy of this method and the applicability of the stress-strain relationships were validated by comparing different existing confined concrete uniaxial constitutive relationships and experimental results. Comparison of these results indicated that this method using the confined concrete uniaxial stress-strain relationships can be used to calculate the ultimate strength and CFST behavior with satisfactory accuracy. The calculation results are stable and seldom affected by concrete con-stitutive relationships. The method is therefore valuable in the practice of engineering design. Finally, the ultimate strength of an arch bridge with span of 330 m was investigated by the proposed method and the nonlinear behavior was discussed.
基金National Natural Science Foundation of China(No.51178119)
文摘The simplified algorithm for out-of-plane ultimate loadcarrying capacity of concrete-filled steel tubular( CFST) solid-rib arches under uniform vertical load was studied. The experimentally validated finite element model was developed. The out-of-plane equivalent length coefficients of solid-rib arches were obtained using out-of-plane elastic eigenvalue buckling analysis. Then the out-ofplane elastic stability coefficient was plotted against the normalized slenderness ratio,and the out-of-plane eigenvalue buckling load or elastic buckling capability of arches was calculated. Lastly effects of different parameters on the out-of-plane ultimate load-carrying capacity of CFST solid-rib arches were determined using geometric and material nonlinear finite element analysis, and a simplified algorithm was established by fitting the out-of-plane elastic-plastic stability coefficient and normalized slenderness ratio using PerryRobertson formula. Ratio of the elastic stability coefficient to the elastic-plastic counterpart was plotted against the out-of-plane normalized slenderness ratio,from which the out-of-plane elasticplastic ultimate load-carrying capacity was determined according to the corresponding elastic buckling load. Results show that the proposed simplified algorithm can accurately predict the out-of-plane eigenvalue buckling load and the elastic-plastic ultimate loadcarrying capacity of the CFST solid-rib arches.