Circulatory responses to nasotracheal intubation: comparison of GlideScope videolaryngoscope and Macintosh direct laryngoscope 被引量:3
1
作者 XUE Fu-shan LI Xuan-ying +5 位作者 LIU Qian-jin LIU He-ping YANG Quan-yong XU Ya-chao LIAO Xu LIU Yi 《Chinese Medical Journal》 SCIE CAS CSCD 2008年第14期1290-1296,共7页
Background The GlideScope videolaryngoscope (GSVL) has been shown to have no special advantage over the Macintosh direct laryngoscope (MDL) in attenuating the circulatory responses to orotracheal intubation, but ... Background The GlideScope videolaryngoscope (GSVL) has been shown to have no special advantage over the Macintosh direct laryngoscope (MDL) in attenuating the circulatory responses to orotracheal intubation, but no study has compared the circulatory responses to nasotracheal intubation (NTI) using the two devices. This prospective randomized clinical study was designed to determine whether there was a clinically relevant difference between the circulatory responses to NTI with the GSVL and the MDL. Methods Seventy-six adult patients were randomly allocated equally to the GSVL group and the MDL group. After induction of anesthesia, NTI was performed. Non-invasive blood pressure (BP) and heart rate (HR) were recorded before induction (baseline values) and immediately before intubation (post-induction values), at intubation and every minute for a further five minutes. During the observation, times required to reach the maximum values of systolic BP (SBP) and HR, times required for recovery of SBP and HR to postinduction values and incidence of SBP and HR percent changes 〉 30% of baseline values were also noted. The product of HR and systolic BP, i.e. rate pressure product (RPP), and the areas under SBP and HR vs. time curves (AUGsBP and AUGHR) were calculated. Results The NTI with the GSVL resulted in significant increases in BP, HR and RPP compared to postinduction values, but these circulatory changes did not exceed baseline values. BPs at all measuring points, AUGSBP, maximum values of BP and incidence of SBP percent increase 〉 30% of baseline value during the observation did not differ significantly between groups. However, HR and RPP at intubation and their maximum values, AUGHR and incidence of HR percent increase 〉 30% of baseline value were significantly higher in the MDL group than in the GSVL group. Times required for recovery of SBP and HR to postinduction values were significantly longer in the MDL group than in the GSVL group. Conclusions The pressor response to NTI with the GSVL and the MDL was similar, but the tachycardiac response to NTI was lesser and of a shorter duration when using a GSVL than when using an MDL. 展开更多
关键词 GlideScope videolaryngoscope Macintosh direct laryngoscope nasotracheal intubation circulatory responses airway management
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部