The estimation of Arterio-Venous ratio (AVR) is an important phase in diagnosing various vascular diseases e.g. Diabetic Retinopathy. For calculating this value, it is essential to differentiate the vessels into arter...The estimation of Arterio-Venous ratio (AVR) is an important phase in diagnosing various vascular diseases e.g. Diabetic Retinopathy. For calculating this value, it is essential to differentiate the vessels into arteries and veins. This paper presents a novel structural and automated method for artery/vein vessels classification in retinal images. Our method is tested on DRIVE database and the classification accuracy is 88.7 % for pixels and 89.07 % for vessel lines, respectively, which demonstrate the effectives of our approach. Our method will help to achieve the fundus disease surveillance on mobile and remote medical treatment. It has a remarkable social significance.展开更多
This research assesses the speed of blood flow across blood vessels and more specifically the veins in terms of Reynold’s number (laminar flow vs. turbulence flow) and in terms of overall speed of the blood when bein...This research assesses the speed of blood flow across blood vessels and more specifically the veins in terms of Reynold’s number (laminar flow vs. turbulence flow) and in terms of overall speed of the blood when being injected with high-speed saline particles. The authors propose a novel technique to generate accelerated-waved particles built from saline solution to enable the unblocking of partially-blocked healthy-walled veins, and to restore normal operations of these veins. The novel technique encompasses a pump that accelerates saline solutions into the blood stream of the vein and these oscillated waves break down the fats or deposits inside the veins in order to help the blood to flow freely without any obstruction. This research simulated the vein with blood stream using characteristics of the vein in terms of vein diameter, blood density, venous blood flow, and the viscosity of the blood at the normal body temperature. The speed of the overall blood flow after the injection of the accelerated saline droplet solution was determined as well as the depth of penetration of the accelerated particles in order to cleanse the inside of the vein. Results are promising in terms of not altering significantly the overall speed of the bloodstream and also in terms of efficacy of the length of the vein which is being cleaned using this accelerated particle method.展开更多
针对由于血管类间具有强相似性造成的动静脉错误分类问题,提出了一种新的融合上下文信息的多尺度视网膜动静脉分类网络(multi-scale retinal artery and vein classification network,MCFNet),该网络使用多尺度特征(multi-scale feature...针对由于血管类间具有强相似性造成的动静脉错误分类问题,提出了一种新的融合上下文信息的多尺度视网膜动静脉分类网络(multi-scale retinal artery and vein classification network,MCFNet),该网络使用多尺度特征(multi-scale feature,MSF)提取模块及高效的全局上下文信息融合(efficient global contextual information aggregation,EGCA)模块结合U型分割网络进行动静脉分类,抑制了倾向于背景的特征并增强了血管的边缘、交点和末端特征,解决了段内动静脉错误分类问题。此外,在U型网络的解码器部分加入3层深度监督,使浅层信息得到充分训练,避免梯度消失,优化训练过程。在2个公开的眼底图像数据集(DRIVE-AV,LES-AV)上,与3种现有网络进行方法对比,该模型的F1评分分别提高了2.86、1.92、0.81个百分点,灵敏度分别提高了4.27、2.43、1.21个百分点,结果表明所提出的模型能够很好地解决动静脉分类错误的问题。展开更多
AIM:To investigate the efficacy of hepatic arterial infusion chemotherapy(HAIC) using floxuridine(FUDR) in patients with advanced hepatocellular carcinoma(HCC) confined to the liver.METHODS:Thirty-four patients who ha...AIM:To investigate the efficacy of hepatic arterial infusion chemotherapy(HAIC) using floxuridine(FUDR) in patients with advanced hepatocellular carcinoma(HCC) confined to the liver.METHODS:Thirty-four patients who had advanced HCC with unresectability or unsuccessful previous therapy in the absence of extrahepatic metastasis were treated with intra-arterial FUDR chemotherapy at ourhospital between March 2005 and May 2008.Among the 34 patients,9 patients were classified as Child class C,and 18 patients had portal vein tumor thrombus(PVTT).One course of chemotherapy consisted of continuous infusion of FUDR(0.3 mg/kg during day 1-14) and dexamethasone(10 mg on day 1,4,7 and 11),and this treatment was repeated every 28 d.RESULTS:Two patients(5.9%) displayed a complete response,and 12 patients(35.3%) had a partial response.The tumor control rate was 61.8%.The median overall survival times were 15.3 mo,12.4 mo and 4.3 mo for the patients who were classified as Child class A,Child class B and Child class C,respectively(P = 0.0392).The progression-free survival was 12.9 mo,7.7 mo and 2.6 mo for the patients who were classified as Child class A,Child class B and Child class C,respectively(P = 0.0443).The cumulative survival differed significantly according to the Child-Pugh classification and the presence of PVTT.In addition to hepatic reserve capacity and PVTT,the extent of HCC was an independent factor in determining a poor prognosis.The most common adverse reactions to HAIC were mucositis,diarrhea and peptic ulcer disease,but most of these complications were improved by medical treatment and/or a delay of HAIC.CONCLUSION:The present study demonstrates that intra-arterial FUDR chemotherapy is a safe and effective treatment for advanced HCC that is recalcitrant to other therapeutic modalities,even in patients with advanced cirrhosis.展开更多
基金This work was supported in part by the Natural Science Foundation of China under Grant 61472102, in part by the Fundamental Research Funds for the Central Universities under Grant HIT.NSRIF.2013091, and in part by the Humanity and Social Science Youth foundation of Ministry of Education of China under Grant 14YJC760001.
文摘The estimation of Arterio-Venous ratio (AVR) is an important phase in diagnosing various vascular diseases e.g. Diabetic Retinopathy. For calculating this value, it is essential to differentiate the vessels into arteries and veins. This paper presents a novel structural and automated method for artery/vein vessels classification in retinal images. Our method is tested on DRIVE database and the classification accuracy is 88.7 % for pixels and 89.07 % for vessel lines, respectively, which demonstrate the effectives of our approach. Our method will help to achieve the fundus disease surveillance on mobile and remote medical treatment. It has a remarkable social significance.
文摘This research assesses the speed of blood flow across blood vessels and more specifically the veins in terms of Reynold’s number (laminar flow vs. turbulence flow) and in terms of overall speed of the blood when being injected with high-speed saline particles. The authors propose a novel technique to generate accelerated-waved particles built from saline solution to enable the unblocking of partially-blocked healthy-walled veins, and to restore normal operations of these veins. The novel technique encompasses a pump that accelerates saline solutions into the blood stream of the vein and these oscillated waves break down the fats or deposits inside the veins in order to help the blood to flow freely without any obstruction. This research simulated the vein with blood stream using characteristics of the vein in terms of vein diameter, blood density, venous blood flow, and the viscosity of the blood at the normal body temperature. The speed of the overall blood flow after the injection of the accelerated saline droplet solution was determined as well as the depth of penetration of the accelerated particles in order to cleanse the inside of the vein. Results are promising in terms of not altering significantly the overall speed of the bloodstream and also in terms of efficacy of the length of the vein which is being cleaned using this accelerated particle method.
文摘针对由于血管类间具有强相似性造成的动静脉错误分类问题,提出了一种新的融合上下文信息的多尺度视网膜动静脉分类网络(multi-scale retinal artery and vein classification network,MCFNet),该网络使用多尺度特征(multi-scale feature,MSF)提取模块及高效的全局上下文信息融合(efficient global contextual information aggregation,EGCA)模块结合U型分割网络进行动静脉分类,抑制了倾向于背景的特征并增强了血管的边缘、交点和末端特征,解决了段内动静脉错误分类问题。此外,在U型网络的解码器部分加入3层深度监督,使浅层信息得到充分训练,避免梯度消失,优化训练过程。在2个公开的眼底图像数据集(DRIVE-AV,LES-AV)上,与3种现有网络进行方法对比,该模型的F1评分分别提高了2.86、1.92、0.81个百分点,灵敏度分别提高了4.27、2.43、1.21个百分点,结果表明所提出的模型能够很好地解决动静脉分类错误的问题。
文摘AIM:To investigate the efficacy of hepatic arterial infusion chemotherapy(HAIC) using floxuridine(FUDR) in patients with advanced hepatocellular carcinoma(HCC) confined to the liver.METHODS:Thirty-four patients who had advanced HCC with unresectability or unsuccessful previous therapy in the absence of extrahepatic metastasis were treated with intra-arterial FUDR chemotherapy at ourhospital between March 2005 and May 2008.Among the 34 patients,9 patients were classified as Child class C,and 18 patients had portal vein tumor thrombus(PVTT).One course of chemotherapy consisted of continuous infusion of FUDR(0.3 mg/kg during day 1-14) and dexamethasone(10 mg on day 1,4,7 and 11),and this treatment was repeated every 28 d.RESULTS:Two patients(5.9%) displayed a complete response,and 12 patients(35.3%) had a partial response.The tumor control rate was 61.8%.The median overall survival times were 15.3 mo,12.4 mo and 4.3 mo for the patients who were classified as Child class A,Child class B and Child class C,respectively(P = 0.0392).The progression-free survival was 12.9 mo,7.7 mo and 2.6 mo for the patients who were classified as Child class A,Child class B and Child class C,respectively(P = 0.0443).The cumulative survival differed significantly according to the Child-Pugh classification and the presence of PVTT.In addition to hepatic reserve capacity and PVTT,the extent of HCC was an independent factor in determining a poor prognosis.The most common adverse reactions to HAIC were mucositis,diarrhea and peptic ulcer disease,but most of these complications were improved by medical treatment and/or a delay of HAIC.CONCLUSION:The present study demonstrates that intra-arterial FUDR chemotherapy is a safe and effective treatment for advanced HCC that is recalcitrant to other therapeutic modalities,even in patients with advanced cirrhosis.