Alzheimer's disease,the primary cause of dementia,is characterized by neuropathologies,such as amyloid plaques,synaptic and neuronal degeneration,and neurofibrillary tangles.Although amyloid plaques are the primar...Alzheimer's disease,the primary cause of dementia,is characterized by neuropathologies,such as amyloid plaques,synaptic and neuronal degeneration,and neurofibrillary tangles.Although amyloid plaques are the primary characteristic of Alzheimer's disease in the central nervous system and peripheral organs,targeting amyloid-beta clearance in the central nervous system has shown limited clinical efficacy in Alzheimer's disease treatment.Metabolic abnormalities are commonly observed in patients with Alzheimer's disease.The liver is the primary peripheral organ involved in amyloid-beta metabolism,playing a crucial role in the pathophysiology of Alzheimer's disease.Notably,impaired cholesterol metabolism in the liver may exacerbate the development of Alzheimer's disease.In this review,we explore the underlying causes of Alzheimer's disease and elucidate the role of the liver in amyloid-beta clearance and cholesterol metabolism.Furthermore,we propose that restoring normal cholesterol metabolism in the liver could represent a promising therapeutic strategy for addressing Alzheimer's disease.展开更多
The dynamic responses of roller gear indexing cam mechanism are investigated .With applying Lagarange equation and Gear method,motion equations of this mechanism including clearance,motor characteristic,torsion flexib...The dynamic responses of roller gear indexing cam mechanism are investigated .With applying Lagarange equation and Gear method,motion equations of this mechanism including clearance,motor characteristic,torsion flexibility are developed and solved.The results show that clearance affects primarily the response on turret,and has little effects on the responses on rotary table.At the same time,the velocity fluctuation of motor shaft is not serious for the existence of inertia of reducer,and the high frequency of velocity fluctuation of camshaft is related with the torsion stiffness of shaft and the clearance between pairs.展开更多
A two-degrees-of-freedom vibratory system with a clearance or gap is under con- sideration based on the Poincaré map.Stability and local bifurcation of the period-one double- impact symmetrical motion of the syst...A two-degrees-of-freedom vibratory system with a clearance or gap is under con- sideration based on the Poincaré map.Stability and local bifurcation of the period-one double- impact symmetrical motion of the system are analyzed by using the equation of map.The routes from periodic impact motions to chaos,via pitchfork bifurcation,period-doubling bifurcation and grazing bifurcation,are studied by numerical simulation.Under suitable system parameter con- ditions,Neimark-Sacker bifurcations associated with periodic impact motion can occur in the two-degrees-of-freedom vibro-impact system.展开更多
A pressure controlled mechanical ventilator with an automatic secretion clearance function can improve secretion clearance safely and efficiently.Studies on secretion clearance by pressure controlled systems show that...A pressure controlled mechanical ventilator with an automatic secretion clearance function can improve secretion clearance safely and efficiently.Studies on secretion clearance by pressure controlled systems show that these are suited for clinical applications.However,these studies are based on a single lung electric model and neglect the coupling between the two lungs.The research methods applied are too complex for the analysis of a multi-parameter system.In order to understand the functioning of the human respiratory system,this paper develops a dimensionless mathematical model of doublelung mechanical ventilation system with a secretion clearance function.An experiment is designed to verify the mathematical model through comparison of dimensionless experimental data and dimensionless simulation data.Finally,the coupling between the two lungs is studied,and an orthogonal experiment designed to identify the impact of each parameter on the system.展开更多
The accelerated blood clearance(ABC) phenomenon which is induced by repeated injection of poly(ethylene glycol)(PEG)-coated colloidal carriers gives clinical challenge to the promising drug delivery system. It is nece...The accelerated blood clearance(ABC) phenomenon which is induced by repeated injection of poly(ethylene glycol)(PEG)-coated colloidal carriers gives clinical challenge to the promising drug delivery system. It is necessary to decrease this unexpected immunological response.A novel 4-arm poly(ethylene glycol-5000)4-cholesteryl methyl amide(4-arm PEG5000-CHMA)has been synthesized. The structure of 4-arm PEG5000-CHMA was confirmed by IR and 1H-NMR spectrum. The pharmacokinetics of the tocopheryl nicotinate(TN)-loaded nanoemulsions modified with 4-arm PEG5000-CHMA or/and 1, 2-distearoyl-Sn-glycero-3-phosphoethanolamine-n-[methoxy(poly-ethyleneglycol)-2000](mPEG2000-DSPE) have been studied. Furthermore, the ABC phenomenon has been detailed investigated in rats by TN-loaded nanoemulsions modified with 4-arm PEG5000-CHMA and mPEG2000-DSPE(CPNE). The plasma levels of TN and anti-PEG IgM antibody were determined by HPLC and ELISA, respectively.The circulation time of the CPNEs were comparable to the mPEG2000-DSPE coated nanoemulsions. Moreover, the ABC phenomenon can be decreased by CPNEs. This study designs a method to decrease the ABC phenomenon and develops a clinical promising nanoemulsion for therapeutic or imaging purpose.展开更多
Few studies were focused on the load-sharing characteristics of double-row planetary gear(DRPG)systems with bearings.Meanwhile,the supported bearing has an important influence on the transmission characteristics of th...Few studies were focused on the load-sharing characteristics of double-row planetary gear(DRPG)systems with bearings.Meanwhile,the supported bearing has an important influence on the transmission characteristics of the entire system.To overcome this problem,a multi-body dynamic(MBD)model of the DRPG system fully considering the influences of bearing parameters is established.Dynamic loads among contacting gear pairs have been obtained to calculate the load-sharing coefficient(LSC)of the system.The LSC of each gear tooth pair has been compared to study the effect of the supported bearing clearance on the load-sharing characteristics.These methods are based on Hertz contact theory.The liner stiffness and damping are used in the model.The results show that the supported bearing clearance has a greatly effect on the LSC of the DRPG system.Choosing appropriate clearance parameters of supported bearing can help suppress the uneven load distribution of the DRPG system.The results can provide some guidance to find new method to study the LSC and increase the service life of planetary gear systems.展开更多
The management of patients with concomitant xenobiotic toxicity and multisystem trauma can be complex. While hemodialysis is generally the modality of choice for extracorporeal elimination of salicylates, the potentia...The management of patients with concomitant xenobiotic toxicity and multisystem trauma can be complex. While hemodialysis is generally the modality of choice for extracorporeal elimination of salicylates, the potential for large volume shifts and hypotension may pose a risk in patients with traumatic brain injury. An alternative therapy to hemodialysis is continuous renal replacement therapy, which has slower clearance rates than hemodialysis, but has decreased adverse effects in cases of traumatic brain injury. However, there are few published reports of clearance rates of salicylates using continuous renal replacement therapy. We report a case of multisystem trauma with concomitant intentional salicylate overdose in which continuous renal replacement therapy was employed. The salicylate clearance rate that was obtained in this case was 7.5 mL/minute using continuous veno-venous hemodiafiltration, a form of continuous renal replacement therapy.展开更多
Objective: To evaluate whether the combination of Uremic clearance granule with Alprostadil is superior to Alprostadil alone for CRF. Methods: Relevant RCTs were searched through March 2019. Data were analyzed by Stat...Objective: To evaluate whether the combination of Uremic clearance granule with Alprostadil is superior to Alprostadil alone for CRF. Methods: Relevant RCTs were searched through March 2019. Data were analyzed by Stata 15.0. Results: Nine articles involving 726 patients were enrolled in this study. Meta-analysis showed that the total effective rate [OR = 3.68 (2.44, 5.55), P < 0.001], Scr [SMD =-2.34 (-3.49,-1.19), P < 0.001], BUN [SMD =-1.80 (-2.73,-0.87), P < 0.001], Ccr [SMD = 0.71 (0.44, 0.97), P < 0.001] were better in the experimental group. But there were no significant difference in UA, CysC, 24h-Upro and incidence of adverse reactions (all P > 0.05) between two groups. No serious adverse reactions were found. Conclusions: The effect of the integrated medicine on CRF was better than Alprostadil alone. Uremic clearance granule is safe and has no obvious adverse reactions.展开更多
Advancements in murine modeling systems for ulcerative colitis have diversified our understanding of the pathophysiological factors involved in disease onset and progression.This has fueled the identification of molec...Advancements in murine modeling systems for ulcerative colitis have diversified our understanding of the pathophysiological factors involved in disease onset and progression.This has fueled the identification of molecular targets,resulting in a rapidly expanding therapeutic armamentarium.Subsequently,management strategies have evolved from symptomatic resolution to well-defined objective endpoints,including clinical remission,endoscopic remission and mucosal healing.While the incorporation of these assessment modalities has permitted targeted intervention in the context of a natural disease history and the prevention of complications,studies have consistently depicted discrepancies associated with ascertaining disease status through clinical and endoscopic measures.Current recommendations lack consideration of histological healing.The simultaneous achievement of clinical,endoscopic,and histologic remission has not been fully investigated.This has laid the groundwork for a novel therapeutic outcome termed disease clearance(DC).This article summarizes the concept of DC and its current evidence.展开更多
Clearances in joints of a mechanical multibody system can induce impulsive forces, leading to vibrations that compromise the system’s reliability, stability, and lifespan. Through dynamic analysis, designers can inve...Clearances in joints of a mechanical multibody system can induce impulsive forces, leading to vibrations that compromise the system’s reliability, stability, and lifespan. Through dynamic analysis, designers can investigate the effects of the clearances on the dynamics of the multibody system. A revolute joint with clearance exhibits three motions which are;free-flight, impact and continuous contact motion modes. Therefore, a multibody system with n-number of revolute clearance joints will exhibit 3n motion modes which are a combination of the three motions in each joint. This study investigates experimentally the nine motion modes in a mechanical system with two revolute clearance joints. A slider crank mechanism has been used as the demonstrative example. We observed that the experimental curve exhibits a greater impact compared to the simulation curve. In conclusion, this experimental investigation offers valuable insights into the dynamics of planar mechanical systems with multiple clearance revolute joints. Utilizing a slider-crank mechanism for data acquisition, the study successfully confirmed seven out of nine motion modes previously identified in numerical research. The missing modes are attributed to inherent complexities in real-world systems, such as journal-bearing misalignment.展开更多
This study evaluated the impact of Ghana’s Integrated Customs Management System (ICUMS), implemented within the National Single Window initiative, on the efficiency of issuing Delivery Orders (DO) at Tema Port. Filli...This study evaluated the impact of Ghana’s Integrated Customs Management System (ICUMS), implemented within the National Single Window initiative, on the efficiency of issuing Delivery Orders (DO) at Tema Port. Filling a gap in the existing literature, the research employed a quantitative approach to assess a specific time-related aspect of the cargo clearance process. Employing an Independent t-test on a dataset spanning 2026 Delivery Orders (924 pre-ICUMS and 1102 post-ICUMS) from July 2020 to July 2023, the study investigated ICUMS’s effectiveness in reducing DO issuance time. Results indicate a noteworthy decrease in average DO issuance time, from 11 days pre-implementation to approximately 9 days post-implementation, a reduction validated by statistical analysis through the independent t-test. In light of these findings, the study recommends ongoing refinement of the implementation, reinforcement of trade facilitation measures, and the adoption of best practices from successful global ports. Continuous stakeholder training and regular assessments of ICUMS performance are also endorsed. The study’s implications support the theoretical framework for Single Window systems and carry significant policy implications, emphasizing the need for collaborative efforts to streamline trade facilitation processes driven by Information Technology. Practically, the results serve as a management tool for stakeholders, highlighting areas for targeted interventions to reduce DO issuance times. Methodologically, this research contributes by applying robust statistical analysis to a specific component within the Time Release Study framework, offering a nuanced understanding of trade facilitation systems’ effectiveness in improving cargo clearance processes.展开更多
This article describes the effects of some factors on the tip clearance flow in axial linear turbine cascades. The measurements of the total pressure loss coefficient are made at the cascade outlets by using a five-ho...This article describes the effects of some factors on the tip clearance flow in axial linear turbine cascades. The measurements of the total pressure loss coefficient are made at the cascade outlets by using a five-hole probe at exit Mach numbers of 0.10, 0.14 and 0.19. At each exit Mach number, experiments are performed at the tip clearance heights of 1.0%, 1.5%, 2.0%, 2.5% and 3.0% of the blade height. The effects of the non-uniform tip clearance height of each blade in the pitchwise direction are also studied. The results show that at a given tip clearance height, generally, total pressure loss rises with exit Mach numbers proportionally. At a fixed exit Mach number, the total pressure loss augments nearly proportionally as the tip clearance height increases. The increased tip clearance heights in the tip regions of two adjacent blades are to be blame for the larger clearance loss of the center blade. Compared to the effects of the tip clearance height, the effects of the exit Mach number and the pitchwise variation of the tip clearance height on the cascade total pressure loss are so less significant to be omitted.展开更多
A centrifugal fan with the high speed and compact dimensions is studied numerically and experimentally. The centrifugal fan consists of a shrouded impeller rotating at 34 000 r/min with a small tip clearance 0.7 mm to...A centrifugal fan with the high speed and compact dimensions is studied numerically and experimentally. The centrifugal fan consists of a shrouded impeller rotating at 34 000 r/min with a small tip clearance 0.7 mm to the fixed outer casing. Computational models with/without the tip clearance are built and the κ-ω shear stress transport (SST) turbulence model and the unstructured mesh are applied to the numerical simulation for unsteady solutions. The overall performance is measured on a standard experimental bench and the major flow feature of each component inside the centrifugal fan is numerically investigated. In the presence of the tip clearance due to the difference of static pressure between leading and trailing edges of the clearance, i. e. , leading and trailing edges of the impeller, a strong return flow exists inside the clearance passage and re-circulates the main stream inside the impeller passage, and produces the strong flow interaction, thus changing the flow field and influencing the overall performance.展开更多
Objective:To explore the easily applicable indicators of practical value to evaluate the prognosis of acute respiratory distress syndrome(ARDS).Methods:Blood and biochemical tests and bloodgas analyses were performe...Objective:To explore the easily applicable indicators of practical value to evaluate the prognosis of acute respiratory distress syndrome(ARDS).Methods:Blood and biochemical tests and bloodgas analyses were performed upon entry into the ICUs,12 h,24 h,48 h and 72 h after that in 72 ARDS patients(who were admitted to the ICUs of our hospital from January 2000 to December 2009).Then APACHEⅡscores were achieved by combining relevant physiological parameters and laboratory results.Results:There was a statistical difference between the death group and survival group at different time points upon entering the ICUs in terms of APACHEⅡscore, alveolar-arterial oxygen difference and arterial blood lactate clearance rate.PaO<sub>2</sub>/FiO<sub>2</sub> values were recorded to be statistically different between the death group and survival group 24 h,48 h and 72 h,respectively after entry into the ICUs.In addition,registered linear regression existed between APACHEⅡscore,alveolar-arterial oxygen difference or PaO<sub>2</sub>/FiO<sub>2</sub> value and time. APACHEⅡscore 24 h and 72 h after entering ICUs predicted mortality with an area under the ROC curve(AUC) standing respectively at 0.919 and 0.9SS.Arterial blood lactate clearance rate 12 h, 24 h,48 h and 72 h after entering ICUs predicted mortality with an area under the ROC curve (AUC) at 0.918,0.918,0.909 and 0.991,respectively.Conclusions:APACHEⅡscore applied in combination with arterial blood lactate clearance rate is of clinical significance in assessing the prognosis of ARDS patients.展开更多
The inner and outer oil film dynamic characteristic coefficients of floating ring bearings(FRBs) change due to the manufacturing tolerance of the floating ring, journal and intermediate, which leads to high-speed tu...The inner and outer oil film dynamic characteristic coefficients of floating ring bearings(FRBs) change due to the manufacturing tolerance of the floating ring, journal and intermediate, which leads to high-speed turbocharger's vibration too large and even causes nonlinear vibration accident. However, the investigation of floating ring bearing manufacturing tolerance clearance on the rotordynamic characteristics is less at present. In order to study the influence law of inner and outer clearance on turbocharger vibration, the rotor dynamic motion equations of turbocharger supported in FRBs are derived by analyzing the size relations between floating ring, journal and intermediate for the inner and outer oil film clearances, the time transient response analysis for combination of FRBs clearance are developed. A realistic turbocharger is taken as a research object, the FE model of the turbocharger with FRBs is modeled. Under the conditions of four kinds of limit state bearing clearances for inner and outer oil film, the nonlinear transient analyses are performed based on the established FE dynamic models of the nonlinear rotor-FRBs system applied incentive combinations of gravity and unbalance force, respectively. From the waterfall, the simulation results show that the speed for the appearance of fractional frequency is not identical and the amplitude magnitude is different under the four kinds of bearing manufacturing tolerance limit clearances, and fractional frequency does not appear in the turbocharger and the amplitude is minimum under the ODMin/IDMax bearing manufacturing tolerance clearances. The turbocharger vibration is reduced by controlling the manufacturing tolerance clearance combinations of FRBs, which is helpful for the dynamic design and production-manufacturing of high-speed turbocharger.展开更多
BACKGROUND Nucleos(t)ide analog(NA)has shown limited effectiveness against hepatitis B surface antigen(HBsAg)clearance in chronic hepatitis B(CHB)patients.AIM To evaluate the efficacy and safety of add-on peginterfero...BACKGROUND Nucleos(t)ide analog(NA)has shown limited effectiveness against hepatitis B surface antigen(HBsAg)clearance in chronic hepatitis B(CHB)patients.AIM To evaluate the efficacy and safety of add-on peginterferonα-2a(peg-IFNα-2a)to an ongoing NA regimen in CHB patients.METHODS In this observational study,195 CHB patients with HBsAg≤1500 IU/m L,hepatitis B e antigen(HBeAg)-negative(including HBeAg-negative patients or HBeAg-positive patients who achieved HBeAg-negative after antiviral treatment with NA)and hepatitis B virus-deoxyribonucleic acid<1.0×10^2 IU/mL after over 1 year of NA therapy were enrolled between November 2015 and December2018 at the Second Affiliated Hospital of Xi'an Jiaotong University,China.Patients were given the choice between receiving either peg-IFNα-2a add-on therapy to an ongoing NA regimen(add-on group,n=91)or continuous NA monotherapy(monotherapy group,n=104)after being informed of the benefits and risks of the peg-IFNα-2a therapy.Total therapy duration of peg-IFNα-2a was 48 wk.All patients were followed-up to week 72(24 wk after discontinuation of peg-IFNα-2a).The primary endpoint was the proportion of patients with HBsAg clearance at week 72.RESULTS Demographic and baseline characteristics were comparable between the two groups.Intention-to-treatment analysis showed that the HBsAg clearance rate in the add-on group and monotherapy group was 37.4%(34/91)and 1.9%(2/104)at week 72,respectively.The HBsAg seroconversion rate in the add-on group was 29.7%(27/91)at week 72,and no patient in the monotherapy group achieved HBsAg seroconversion at week 72.The HBsAg clearance and seroconversion rates in the add-on group were significantly higher than in the monotherapy group at week 72(P<0.001).Younger patients,lower baseline HBsAg concentration,lower HBsAg concentrations at weeks 12 and 24,greater HBsAg decline from baseline to weeks 12 and 24 and the alanine aminotransferase≥2×upper limit of normal during the first 12 wk of therapy were strong predictors of HBsAg clearance in patients with peg-IFNα-2a add-on treatment.Regarding the safety of the treatment,4.4%(4/91)of patients in the add-on group discontinued peg-IFNα-2a due to adverse events.No severe adverse events were noted.CONCLUSION Peg-IFNα-2a as an add-on therapy augments HBsAg clearance in HBeAg-negative CHB patients with HBsAg≤1500 IU/m L after over 1 year of NA therapy.展开更多
BACKGROUND: Acute liver failure(ALF) is an acute severe deterioration of liver function with high mortality. Early and accurate prognostic assessment of patients with ALF is critically important. Although the model fo...BACKGROUND: Acute liver failure(ALF) is an acute severe deterioration of liver function with high mortality. Early and accurate prognostic assessment of patients with ALF is critically important. Although the model for end-stage liver disease(MELD) scores and King’s College Hospital(KCH) criteria are well-accepted as predictive tools, their accuracy is unsatisfactory.The indocyanine green(ICG) clearance test(ICGR15, ICG retention rate at the 15 minutes) is a sensitive indicator of liver function. In this study, we investigated the efficacy of the ICGR15 for the short-term prognosis in patients with ALF. We compared the predictive value of ICGR15 with the MELD scores and KCH criteria.METHODS: Sixty-nine patients who had been diagnosed with ALF were recruited retrospectively. ICGR15 had been performed by ICG pulse spectrophotometry and relevant clinical and laboratory indices were analyzed within 24 hours of diagnosis.In addition, the MELD scores and KCH criteria were calculated.RESULTS: The three-month mortality of all patients was 47.83%.Age, serum total bilirubin and creatinine concentrations,international normalized ratio for prothrombin time, ICGR15,MELD scores and KCH criteria differed significantly between surviving and deceased patients. A positive correlation was observed between ICGR15 and MELD scores(r=0.328, P=0.006).The ICGR15-MELD model, Logit(P)=0.096×ICGR15+0.174 ×MELD score–9.346, was constructed by logistic regression analysis. The area under the receiver operating characteristic curve was 0.855. When set the cut-off point to-0.4684, the sensitivity was 87.90% and specificity, 72.20%. The area under the receiver operating characteristic curve of the ICGR15-MELD model(0.855) was significantly higher than that of the ICGR15(0.793), MELD scores(0.776) and KCH criteria(0.659).Based on this cut-off value, the patients were divided into two groups. The mortality was 74.36% in the first group(ICGR15-MELD≥-0.4686) and 13.33% in the second group(ICGR15-MELD<-0.4686), with a significant difference between the two groups(χ2=25.307, P=0.000).CONCLUSION: The ICGR15-MELD model is superior to the ICGR15, MELD scores, and KCH criteria in predicting the shortterm prognosis of patients with ALF.展开更多
Semi-floating ring bearing(SFRB) is developed to control the vibration of turbocharger rotor. The outer clearance of SFRB affects the magnitude and frequency of nonlinear whirl motion, which is significant for the d...Semi-floating ring bearing(SFRB) is developed to control the vibration of turbocharger rotor. The outer clearance of SFRB affects the magnitude and frequency of nonlinear whirl motion, which is significant for the design of turbocharger. In order to explore the effects of outer clearance, a transient finite element analysis program for rotor and oil film bearing is built and validated by a published experimental case. The nonlinear dynamic behaviors ofrotor-SFRB system are simulated. According to the simulation results, two representative subsynchronous oscillations excited by the two hearings respectively are discovered. As the outer clearance of SFRB increases from 24 ~tm to 60 pro, the low-frequency subsynchronous oscillation experiences three steps, including a strong start, a gradual recession and a combination with the other one. At the same time, the high-frequency subsynchronous oscillation starts to appear gradually, then strengthens, and finally combines. If gravity and unbalance are neglected, the combination will start starts from high rotor speed and extents to low rotor speed, just like a "zipper". It is found from the quantitative analysis that when the outer clearance increases, the vibration amplitude experiences large value firstly, then reduction, and suddenly increasing after combination. A useful design principle of SFRB outer clearance for minimum vibration amplitude is proposed: the outer clearance value should be chosen to keep the frequency of two subsynchronous oscillations clearly separated and their amplitudes close.展开更多
The clearances appear in chain link hinges induced by manufacturing tolerance or wear of components are the most important factor that influences the dynamic performance of the intermittent roller chain drives. Due to...The clearances appear in chain link hinges induced by manufacturing tolerance or wear of components are the most important factor that influences the dynamic performance of the intermittent roller chain drives. Due to the existence of the clearances in chain link hinges, the serious impact vibration phenomenon which influences the stability and the position accuracy of the chain drive system would be caused in the intermittent motion. But, the problem may be that a reasonable modeling on the chain with clearances is difficult due to the large clearance's number in chain system and the fact that the clearance' size are different. Currently, the studies on the dynamics of the intermittent roller chain considering the multi-clearance' joints are rare. Most research works have only focused on the constant moving chains. Taking the intermittent roller chain system as an object, this paper designs and builds the experimental device of this kind of mechanical system. The Longitudinal vibration response of the intermittent chain under the different motion laws was tested. The experimental study shows that the clearances presented in chain link hinges can cause severe impact vibration in the intermittent motion of chain. In subsequent work, the dynamic model of the intermittent roller chain system with the multi-clearance' joints was established. By calculating the dynamic response of this kind of mechanical system under the different motion laws, the effect of the clearances on the dynamic response of the intermittent chain drive system was analyzed. The theoretical simulation shows that the serious impact vibration phenomenon of the chain system can be caused by the clearances at the start accelerating period, and the chain drive system is often accompanied by the severe shock and vibration at the moment that the chain moves from the acceleration period to deceleration period. The research conclusions made by the experimental and theoretical studies indicate that the use of motion laws with small and continuous jerk at conversion point can effectively suppress the impact vibration at this point caused by clearances' effect. Additionally, the use of nonsymmetrical motion laws with small jerk approaching the end of the indexing period can obtain a smaller residual vibration. The presented motion law can provide an important reference for the improvement of the dynamic performance of the intermittent chain drive systems.展开更多
Variable nozzle turbine (VNT) has become a popular variable geometry turbine (VGT) technology for the diesel engine application. Nozzle clearance, which can't be avoided on the hub and shroud side of the VNT turb...Variable nozzle turbine (VNT) has become a popular variable geometry turbine (VGT) technology for the diesel engine application. Nozzle clearance, which can't be avoided on the hub and shroud side of the VNT turbine due to the pivoting stators, can lead to turbine performance deterioration. However, its mechanism is still not clear. In this paper, numerical investigation, which is validated by experiment, is carried out to study the mechanism of the nozzle clearance's effect on the turbine performance. Firstly, performance of the mixed flow turbine with fixed nozzle clearances tested on flow bench. Performance of the tested turbine with the same nozzle clearance is numerically simulated. The numerical result agrees well with the test data, which proves correct of the numerical method. Then the turbine performance with different nozzle clearances is numerically analyzed. The research showed that with nozzle clearance, flow loss in the nozzle increases at first and it reaches the maximum value when the clearance ratio is 5%. Flow at the exit of the nozzle becomes less uniform with nozzle clearance. The negative incidence angle of the rotor also increases with nozzle clearance and leads to more incidence angle loss in the rotor. The low energy fluid formed in the nozzle due to the nozzle clearance migrates from hub to shroud side in the rotor, which is another main reason for the rotor's performance degradation. The present research exposed the mechanism of the dramatically decrease of the turbine performance with nozzle clearance: (a) The loss associated with the nozzle leakage increases with the nozzle clearance; (b) The flow loss grows up quickly in the rotor due to the incidence angle loss and migration of the low energy fluid from hub to shroud side.展开更多
基金financially supported by the Science and Technology Innovation Program of Hunan Province,No.2022RC1220(to WP)China Postdoctoral Science Foundation,No.2022M711733(to ZZ)+2 种基金the National Natural Science Foundation of China,No.82160920(to ZZ)Hebei Postdoctoral Scientific Research Project,No.B2022003040(to ZZ)Hunan Flagship Department of Integrated Traditional Chinese and Western Medicine(to WP)。
文摘Alzheimer's disease,the primary cause of dementia,is characterized by neuropathologies,such as amyloid plaques,synaptic and neuronal degeneration,and neurofibrillary tangles.Although amyloid plaques are the primary characteristic of Alzheimer's disease in the central nervous system and peripheral organs,targeting amyloid-beta clearance in the central nervous system has shown limited clinical efficacy in Alzheimer's disease treatment.Metabolic abnormalities are commonly observed in patients with Alzheimer's disease.The liver is the primary peripheral organ involved in amyloid-beta metabolism,playing a crucial role in the pathophysiology of Alzheimer's disease.Notably,impaired cholesterol metabolism in the liver may exacerbate the development of Alzheimer's disease.In this review,we explore the underlying causes of Alzheimer's disease and elucidate the role of the liver in amyloid-beta clearance and cholesterol metabolism.Furthermore,we propose that restoring normal cholesterol metabolism in the liver could represent a promising therapeutic strategy for addressing Alzheimer's disease.
文摘The dynamic responses of roller gear indexing cam mechanism are investigated .With applying Lagarange equation and Gear method,motion equations of this mechanism including clearance,motor characteristic,torsion flexibility are developed and solved.The results show that clearance affects primarily the response on turret,and has little effects on the responses on rotary table.At the same time,the velocity fluctuation of motor shaft is not serious for the existence of inertia of reducer,and the high frequency of velocity fluctuation of camshaft is related with the torsion stiffness of shaft and the clearance between pairs.
基金Project supported by the National Natural Science Foundation of China (Nos.10172042 and 10072051)Science Foundation of Education Ministry of China for Ph.D Programmes (No.20010613001).
文摘A two-degrees-of-freedom vibratory system with a clearance or gap is under con- sideration based on the Poincaré map.Stability and local bifurcation of the period-one double- impact symmetrical motion of the system are analyzed by using the equation of map.The routes from periodic impact motions to chaos,via pitchfork bifurcation,period-doubling bifurcation and grazing bifurcation,are studied by numerical simulation.Under suitable system parameter con- ditions,Neimark-Sacker bifurcations associated with periodic impact motion can occur in the two-degrees-of-freedom vibro-impact system.
文摘A pressure controlled mechanical ventilator with an automatic secretion clearance function can improve secretion clearance safely and efficiently.Studies on secretion clearance by pressure controlled systems show that these are suited for clinical applications.However,these studies are based on a single lung electric model and neglect the coupling between the two lungs.The research methods applied are too complex for the analysis of a multi-parameter system.In order to understand the functioning of the human respiratory system,this paper develops a dimensionless mathematical model of doublelung mechanical ventilation system with a secretion clearance function.An experiment is designed to verify the mathematical model through comparison of dimensionless experimental data and dimensionless simulation data.Finally,the coupling between the two lungs is studied,and an orthogonal experiment designed to identify the impact of each parameter on the system.
基金supported by the National Natural Science Foundation of China (Grant No. 81072602, Grant No. 81373334)
文摘The accelerated blood clearance(ABC) phenomenon which is induced by repeated injection of poly(ethylene glycol)(PEG)-coated colloidal carriers gives clinical challenge to the promising drug delivery system. It is necessary to decrease this unexpected immunological response.A novel 4-arm poly(ethylene glycol-5000)4-cholesteryl methyl amide(4-arm PEG5000-CHMA)has been synthesized. The structure of 4-arm PEG5000-CHMA was confirmed by IR and 1H-NMR spectrum. The pharmacokinetics of the tocopheryl nicotinate(TN)-loaded nanoemulsions modified with 4-arm PEG5000-CHMA or/and 1, 2-distearoyl-Sn-glycero-3-phosphoethanolamine-n-[methoxy(poly-ethyleneglycol)-2000](mPEG2000-DSPE) have been studied. Furthermore, the ABC phenomenon has been detailed investigated in rats by TN-loaded nanoemulsions modified with 4-arm PEG5000-CHMA and mPEG2000-DSPE(CPNE). The plasma levels of TN and anti-PEG IgM antibody were determined by HPLC and ELISA, respectively.The circulation time of the CPNEs were comparable to the mPEG2000-DSPE coated nanoemulsions. Moreover, the ABC phenomenon can be decreased by CPNEs. This study designs a method to decrease the ABC phenomenon and develops a clinical promising nanoemulsion for therapeutic or imaging purpose.
基金National Natural Science Foundation of China(No.51975068)。
文摘Few studies were focused on the load-sharing characteristics of double-row planetary gear(DRPG)systems with bearings.Meanwhile,the supported bearing has an important influence on the transmission characteristics of the entire system.To overcome this problem,a multi-body dynamic(MBD)model of the DRPG system fully considering the influences of bearing parameters is established.Dynamic loads among contacting gear pairs have been obtained to calculate the load-sharing coefficient(LSC)of the system.The LSC of each gear tooth pair has been compared to study the effect of the supported bearing clearance on the load-sharing characteristics.These methods are based on Hertz contact theory.The liner stiffness and damping are used in the model.The results show that the supported bearing clearance has a greatly effect on the LSC of the DRPG system.Choosing appropriate clearance parameters of supported bearing can help suppress the uneven load distribution of the DRPG system.The results can provide some guidance to find new method to study the LSC and increase the service life of planetary gear systems.
文摘The management of patients with concomitant xenobiotic toxicity and multisystem trauma can be complex. While hemodialysis is generally the modality of choice for extracorporeal elimination of salicylates, the potential for large volume shifts and hypotension may pose a risk in patients with traumatic brain injury. An alternative therapy to hemodialysis is continuous renal replacement therapy, which has slower clearance rates than hemodialysis, but has decreased adverse effects in cases of traumatic brain injury. However, there are few published reports of clearance rates of salicylates using continuous renal replacement therapy. We report a case of multisystem trauma with concomitant intentional salicylate overdose in which continuous renal replacement therapy was employed. The salicylate clearance rate that was obtained in this case was 7.5 mL/minute using continuous veno-venous hemodiafiltration, a form of continuous renal replacement therapy.
文摘Objective: To evaluate whether the combination of Uremic clearance granule with Alprostadil is superior to Alprostadil alone for CRF. Methods: Relevant RCTs were searched through March 2019. Data were analyzed by Stata 15.0. Results: Nine articles involving 726 patients were enrolled in this study. Meta-analysis showed that the total effective rate [OR = 3.68 (2.44, 5.55), P < 0.001], Scr [SMD =-2.34 (-3.49,-1.19), P < 0.001], BUN [SMD =-1.80 (-2.73,-0.87), P < 0.001], Ccr [SMD = 0.71 (0.44, 0.97), P < 0.001] were better in the experimental group. But there were no significant difference in UA, CysC, 24h-Upro and incidence of adverse reactions (all P > 0.05) between two groups. No serious adverse reactions were found. Conclusions: The effect of the integrated medicine on CRF was better than Alprostadil alone. Uremic clearance granule is safe and has no obvious adverse reactions.
文摘Advancements in murine modeling systems for ulcerative colitis have diversified our understanding of the pathophysiological factors involved in disease onset and progression.This has fueled the identification of molecular targets,resulting in a rapidly expanding therapeutic armamentarium.Subsequently,management strategies have evolved from symptomatic resolution to well-defined objective endpoints,including clinical remission,endoscopic remission and mucosal healing.While the incorporation of these assessment modalities has permitted targeted intervention in the context of a natural disease history and the prevention of complications,studies have consistently depicted discrepancies associated with ascertaining disease status through clinical and endoscopic measures.Current recommendations lack consideration of histological healing.The simultaneous achievement of clinical,endoscopic,and histologic remission has not been fully investigated.This has laid the groundwork for a novel therapeutic outcome termed disease clearance(DC).This article summarizes the concept of DC and its current evidence.
文摘Clearances in joints of a mechanical multibody system can induce impulsive forces, leading to vibrations that compromise the system’s reliability, stability, and lifespan. Through dynamic analysis, designers can investigate the effects of the clearances on the dynamics of the multibody system. A revolute joint with clearance exhibits three motions which are;free-flight, impact and continuous contact motion modes. Therefore, a multibody system with n-number of revolute clearance joints will exhibit 3n motion modes which are a combination of the three motions in each joint. This study investigates experimentally the nine motion modes in a mechanical system with two revolute clearance joints. A slider crank mechanism has been used as the demonstrative example. We observed that the experimental curve exhibits a greater impact compared to the simulation curve. In conclusion, this experimental investigation offers valuable insights into the dynamics of planar mechanical systems with multiple clearance revolute joints. Utilizing a slider-crank mechanism for data acquisition, the study successfully confirmed seven out of nine motion modes previously identified in numerical research. The missing modes are attributed to inherent complexities in real-world systems, such as journal-bearing misalignment.
文摘This study evaluated the impact of Ghana’s Integrated Customs Management System (ICUMS), implemented within the National Single Window initiative, on the efficiency of issuing Delivery Orders (DO) at Tema Port. Filling a gap in the existing literature, the research employed a quantitative approach to assess a specific time-related aspect of the cargo clearance process. Employing an Independent t-test on a dataset spanning 2026 Delivery Orders (924 pre-ICUMS and 1102 post-ICUMS) from July 2020 to July 2023, the study investigated ICUMS’s effectiveness in reducing DO issuance time. Results indicate a noteworthy decrease in average DO issuance time, from 11 days pre-implementation to approximately 9 days post-implementation, a reduction validated by statistical analysis through the independent t-test. In light of these findings, the study recommends ongoing refinement of the implementation, reinforcement of trade facilitation measures, and the adoption of best practices from successful global ports. Continuous stakeholder training and regular assessments of ICUMS performance are also endorsed. The study’s implications support the theoretical framework for Single Window systems and carry significant policy implications, emphasizing the need for collaborative efforts to streamline trade facilitation processes driven by Information Technology. Practically, the results serve as a management tool for stakeholders, highlighting areas for targeted interventions to reduce DO issuance times. Methodologically, this research contributes by applying robust statistical analysis to a specific component within the Time Release Study framework, offering a nuanced understanding of trade facilitation systems’ effectiveness in improving cargo clearance processes.
基金National Natural Science Foundation of China (10377011)
文摘This article describes the effects of some factors on the tip clearance flow in axial linear turbine cascades. The measurements of the total pressure loss coefficient are made at the cascade outlets by using a five-hole probe at exit Mach numbers of 0.10, 0.14 and 0.19. At each exit Mach number, experiments are performed at the tip clearance heights of 1.0%, 1.5%, 2.0%, 2.5% and 3.0% of the blade height. The effects of the non-uniform tip clearance height of each blade in the pitchwise direction are also studied. The results show that at a given tip clearance height, generally, total pressure loss rises with exit Mach numbers proportionally. At a fixed exit Mach number, the total pressure loss augments nearly proportionally as the tip clearance height increases. The increased tip clearance heights in the tip regions of two adjacent blades are to be blame for the larger clearance loss of the center blade. Compared to the effects of the tip clearance height, the effects of the exit Mach number and the pitchwise variation of the tip clearance height on the cascade total pressure loss are so less significant to be omitted.
文摘A centrifugal fan with the high speed and compact dimensions is studied numerically and experimentally. The centrifugal fan consists of a shrouded impeller rotating at 34 000 r/min with a small tip clearance 0.7 mm to the fixed outer casing. Computational models with/without the tip clearance are built and the κ-ω shear stress transport (SST) turbulence model and the unstructured mesh are applied to the numerical simulation for unsteady solutions. The overall performance is measured on a standard experimental bench and the major flow feature of each component inside the centrifugal fan is numerically investigated. In the presence of the tip clearance due to the difference of static pressure between leading and trailing edges of the clearance, i. e. , leading and trailing edges of the impeller, a strong return flow exists inside the clearance passage and re-circulates the main stream inside the impeller passage, and produces the strong flow interaction, thus changing the flow field and influencing the overall performance.
基金sponsored by Guangdong Science and Technology Project(No:2009B03081118)
文摘Objective:To explore the easily applicable indicators of practical value to evaluate the prognosis of acute respiratory distress syndrome(ARDS).Methods:Blood and biochemical tests and bloodgas analyses were performed upon entry into the ICUs,12 h,24 h,48 h and 72 h after that in 72 ARDS patients(who were admitted to the ICUs of our hospital from January 2000 to December 2009).Then APACHEⅡscores were achieved by combining relevant physiological parameters and laboratory results.Results:There was a statistical difference between the death group and survival group at different time points upon entering the ICUs in terms of APACHEⅡscore, alveolar-arterial oxygen difference and arterial blood lactate clearance rate.PaO<sub>2</sub>/FiO<sub>2</sub> values were recorded to be statistically different between the death group and survival group 24 h,48 h and 72 h,respectively after entry into the ICUs.In addition,registered linear regression existed between APACHEⅡscore,alveolar-arterial oxygen difference or PaO<sub>2</sub>/FiO<sub>2</sub> value and time. APACHEⅡscore 24 h and 72 h after entering ICUs predicted mortality with an area under the ROC curve(AUC) standing respectively at 0.919 and 0.9SS.Arterial blood lactate clearance rate 12 h, 24 h,48 h and 72 h after entering ICUs predicted mortality with an area under the ROC curve (AUC) at 0.918,0.918,0.909 and 0.991,respectively.Conclusions:APACHEⅡscore applied in combination with arterial blood lactate clearance rate is of clinical significance in assessing the prognosis of ARDS patients.
基金Supported by National Natural Science Foundation of China(Grant Nos.51205121,51375162)Scientific Research Foundation of Hunan Provincial Education Department of China(Grant No.13A023)Postgraduate Innovation Foundation of Hunan University of Science and Technology,China(Grant No.S140020)
文摘The inner and outer oil film dynamic characteristic coefficients of floating ring bearings(FRBs) change due to the manufacturing tolerance of the floating ring, journal and intermediate, which leads to high-speed turbocharger's vibration too large and even causes nonlinear vibration accident. However, the investigation of floating ring bearing manufacturing tolerance clearance on the rotordynamic characteristics is less at present. In order to study the influence law of inner and outer clearance on turbocharger vibration, the rotor dynamic motion equations of turbocharger supported in FRBs are derived by analyzing the size relations between floating ring, journal and intermediate for the inner and outer oil film clearances, the time transient response analysis for combination of FRBs clearance are developed. A realistic turbocharger is taken as a research object, the FE model of the turbocharger with FRBs is modeled. Under the conditions of four kinds of limit state bearing clearances for inner and outer oil film, the nonlinear transient analyses are performed based on the established FE dynamic models of the nonlinear rotor-FRBs system applied incentive combinations of gravity and unbalance force, respectively. From the waterfall, the simulation results show that the speed for the appearance of fractional frequency is not identical and the amplitude magnitude is different under the four kinds of bearing manufacturing tolerance limit clearances, and fractional frequency does not appear in the turbocharger and the amplitude is minimum under the ODMin/IDMax bearing manufacturing tolerance clearances. The turbocharger vibration is reduced by controlling the manufacturing tolerance clearance combinations of FRBs, which is helpful for the dynamic design and production-manufacturing of high-speed turbocharger.
基金the National Natural Science Foundation of China,No.31500650。
文摘BACKGROUND Nucleos(t)ide analog(NA)has shown limited effectiveness against hepatitis B surface antigen(HBsAg)clearance in chronic hepatitis B(CHB)patients.AIM To evaluate the efficacy and safety of add-on peginterferonα-2a(peg-IFNα-2a)to an ongoing NA regimen in CHB patients.METHODS In this observational study,195 CHB patients with HBsAg≤1500 IU/m L,hepatitis B e antigen(HBeAg)-negative(including HBeAg-negative patients or HBeAg-positive patients who achieved HBeAg-negative after antiviral treatment with NA)and hepatitis B virus-deoxyribonucleic acid<1.0×10^2 IU/mL after over 1 year of NA therapy were enrolled between November 2015 and December2018 at the Second Affiliated Hospital of Xi'an Jiaotong University,China.Patients were given the choice between receiving either peg-IFNα-2a add-on therapy to an ongoing NA regimen(add-on group,n=91)or continuous NA monotherapy(monotherapy group,n=104)after being informed of the benefits and risks of the peg-IFNα-2a therapy.Total therapy duration of peg-IFNα-2a was 48 wk.All patients were followed-up to week 72(24 wk after discontinuation of peg-IFNα-2a).The primary endpoint was the proportion of patients with HBsAg clearance at week 72.RESULTS Demographic and baseline characteristics were comparable between the two groups.Intention-to-treatment analysis showed that the HBsAg clearance rate in the add-on group and monotherapy group was 37.4%(34/91)and 1.9%(2/104)at week 72,respectively.The HBsAg seroconversion rate in the add-on group was 29.7%(27/91)at week 72,and no patient in the monotherapy group achieved HBsAg seroconversion at week 72.The HBsAg clearance and seroconversion rates in the add-on group were significantly higher than in the monotherapy group at week 72(P<0.001).Younger patients,lower baseline HBsAg concentration,lower HBsAg concentrations at weeks 12 and 24,greater HBsAg decline from baseline to weeks 12 and 24 and the alanine aminotransferase≥2×upper limit of normal during the first 12 wk of therapy were strong predictors of HBsAg clearance in patients with peg-IFNα-2a add-on treatment.Regarding the safety of the treatment,4.4%(4/91)of patients in the add-on group discontinued peg-IFNα-2a due to adverse events.No severe adverse events were noted.CONCLUSION Peg-IFNα-2a as an add-on therapy augments HBsAg clearance in HBeAg-negative CHB patients with HBsAg≤1500 IU/m L after over 1 year of NA therapy.
基金supported by a grant from the Foundation of the Ministry of Health,China(2008ZX1005)
文摘BACKGROUND: Acute liver failure(ALF) is an acute severe deterioration of liver function with high mortality. Early and accurate prognostic assessment of patients with ALF is critically important. Although the model for end-stage liver disease(MELD) scores and King’s College Hospital(KCH) criteria are well-accepted as predictive tools, their accuracy is unsatisfactory.The indocyanine green(ICG) clearance test(ICGR15, ICG retention rate at the 15 minutes) is a sensitive indicator of liver function. In this study, we investigated the efficacy of the ICGR15 for the short-term prognosis in patients with ALF. We compared the predictive value of ICGR15 with the MELD scores and KCH criteria.METHODS: Sixty-nine patients who had been diagnosed with ALF were recruited retrospectively. ICGR15 had been performed by ICG pulse spectrophotometry and relevant clinical and laboratory indices were analyzed within 24 hours of diagnosis.In addition, the MELD scores and KCH criteria were calculated.RESULTS: The three-month mortality of all patients was 47.83%.Age, serum total bilirubin and creatinine concentrations,international normalized ratio for prothrombin time, ICGR15,MELD scores and KCH criteria differed significantly between surviving and deceased patients. A positive correlation was observed between ICGR15 and MELD scores(r=0.328, P=0.006).The ICGR15-MELD model, Logit(P)=0.096×ICGR15+0.174 ×MELD score–9.346, was constructed by logistic regression analysis. The area under the receiver operating characteristic curve was 0.855. When set the cut-off point to-0.4684, the sensitivity was 87.90% and specificity, 72.20%. The area under the receiver operating characteristic curve of the ICGR15-MELD model(0.855) was significantly higher than that of the ICGR15(0.793), MELD scores(0.776) and KCH criteria(0.659).Based on this cut-off value, the patients were divided into two groups. The mortality was 74.36% in the first group(ICGR15-MELD≥-0.4686) and 13.33% in the second group(ICGR15-MELD<-0.4686), with a significant difference between the two groups(χ2=25.307, P=0.000).CONCLUSION: The ICGR15-MELD model is superior to the ICGR15, MELD scores, and KCH criteria in predicting the shortterm prognosis of patients with ALF.
基金Supported by National Natural Science Foundation of China(Grant No51506108)
文摘Semi-floating ring bearing(SFRB) is developed to control the vibration of turbocharger rotor. The outer clearance of SFRB affects the magnitude and frequency of nonlinear whirl motion, which is significant for the design of turbocharger. In order to explore the effects of outer clearance, a transient finite element analysis program for rotor and oil film bearing is built and validated by a published experimental case. The nonlinear dynamic behaviors ofrotor-SFRB system are simulated. According to the simulation results, two representative subsynchronous oscillations excited by the two hearings respectively are discovered. As the outer clearance of SFRB increases from 24 ~tm to 60 pro, the low-frequency subsynchronous oscillation experiences three steps, including a strong start, a gradual recession and a combination with the other one. At the same time, the high-frequency subsynchronous oscillation starts to appear gradually, then strengthens, and finally combines. If gravity and unbalance are neglected, the combination will start starts from high rotor speed and extents to low rotor speed, just like a "zipper". It is found from the quantitative analysis that when the outer clearance increases, the vibration amplitude experiences large value firstly, then reduction, and suddenly increasing after combination. A useful design principle of SFRB outer clearance for minimum vibration amplitude is proposed: the outer clearance value should be chosen to keep the frequency of two subsynchronous oscillations clearly separated and their amplitudes close.
基金supported by National Natural Science Foundation of China (Grant No. 50605060)Tianjin Municipal Natural Science Foundation of China (Grant No. 06YFJMJC03300)
文摘The clearances appear in chain link hinges induced by manufacturing tolerance or wear of components are the most important factor that influences the dynamic performance of the intermittent roller chain drives. Due to the existence of the clearances in chain link hinges, the serious impact vibration phenomenon which influences the stability and the position accuracy of the chain drive system would be caused in the intermittent motion. But, the problem may be that a reasonable modeling on the chain with clearances is difficult due to the large clearance's number in chain system and the fact that the clearance' size are different. Currently, the studies on the dynamics of the intermittent roller chain considering the multi-clearance' joints are rare. Most research works have only focused on the constant moving chains. Taking the intermittent roller chain system as an object, this paper designs and builds the experimental device of this kind of mechanical system. The Longitudinal vibration response of the intermittent chain under the different motion laws was tested. The experimental study shows that the clearances presented in chain link hinges can cause severe impact vibration in the intermittent motion of chain. In subsequent work, the dynamic model of the intermittent roller chain system with the multi-clearance' joints was established. By calculating the dynamic response of this kind of mechanical system under the different motion laws, the effect of the clearances on the dynamic response of the intermittent chain drive system was analyzed. The theoretical simulation shows that the serious impact vibration phenomenon of the chain system can be caused by the clearances at the start accelerating period, and the chain drive system is often accompanied by the severe shock and vibration at the moment that the chain moves from the acceleration period to deceleration period. The research conclusions made by the experimental and theoretical studies indicate that the use of motion laws with small and continuous jerk at conversion point can effectively suppress the impact vibration at this point caused by clearances' effect. Additionally, the use of nonsymmetrical motion laws with small jerk approaching the end of the indexing period can obtain a smaller residual vibration. The presented motion law can provide an important reference for the improvement of the dynamic performance of the intermittent chain drive systems.
基金supported by Advanced Boost System Development for Diesel HCCI Application of DOE(Grant No. DE-FC26-07-NT43280)
文摘Variable nozzle turbine (VNT) has become a popular variable geometry turbine (VGT) technology for the diesel engine application. Nozzle clearance, which can't be avoided on the hub and shroud side of the VNT turbine due to the pivoting stators, can lead to turbine performance deterioration. However, its mechanism is still not clear. In this paper, numerical investigation, which is validated by experiment, is carried out to study the mechanism of the nozzle clearance's effect on the turbine performance. Firstly, performance of the mixed flow turbine with fixed nozzle clearances tested on flow bench. Performance of the tested turbine with the same nozzle clearance is numerically simulated. The numerical result agrees well with the test data, which proves correct of the numerical method. Then the turbine performance with different nozzle clearances is numerically analyzed. The research showed that with nozzle clearance, flow loss in the nozzle increases at first and it reaches the maximum value when the clearance ratio is 5%. Flow at the exit of the nozzle becomes less uniform with nozzle clearance. The negative incidence angle of the rotor also increases with nozzle clearance and leads to more incidence angle loss in the rotor. The low energy fluid formed in the nozzle due to the nozzle clearance migrates from hub to shroud side in the rotor, which is another main reason for the rotor's performance degradation. The present research exposed the mechanism of the dramatically decrease of the turbine performance with nozzle clearance: (a) The loss associated with the nozzle leakage increases with the nozzle clearance; (b) The flow loss grows up quickly in the rotor due to the incidence angle loss and migration of the low energy fluid from hub to shroud side.