期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Digital close-range photogrammetric application to small-scale physical simulation experiment
1
作者 LI Chun-yi1, CUI Xi-min2, YU Yi-ju3 1. School of Surveying and Landing Information Engineering, Henan Polytechnic University, Jiaozuo 454003, China 2. College of Geoscience and Surveying Engineering, China University of Mining and Technology, Beijing 100083, China 3. Surveying and Mapping Press, Beijing 100045, China 《中国有色金属学会会刊:英文版》 CSCD 2011年第S3期681-685,共5页
In order to research the possibility of digital close-range photogrammetric surveying in small scale physical simulation experiment, physical model coinciding with engineering practice was constructed based on similar... In order to research the possibility of digital close-range photogrammetric surveying in small scale physical simulation experiment, physical model coinciding with engineering practice was constructed based on similar theory. The datum processing method and surveying precision of digital close-range photogrammetric were analyzed. And the function relationship between overburden subsidence factor qr and the ratio z/H of stratum horizon z and mining depth H was researched. The results show that surveying points position mean error along horizontal direction is ±0.131 mm and vertical direction is ±0.192 mm. Therefore, multi-taking station cross direction digital close-range photogrammetric can completely satisfy the precision need of physical simulation experiment. And the empirical formula can be utilized to represent evolution law of stratum subsidence factor. 展开更多
关键词 close-range photogrammetric physical simulation light-rays adjustment surveyING PRECISION SUBSIDENCE FACTOR
下载PDF
Energy Efficiency, Indoor Air Quality and Thermal Comfort Studies at the Faculty of Engineering and Built Environment, University Kebangsaan Malaysia
2
作者 N.L. Teng S.M. Zain +1 位作者 N.E.A. Basri S. Mat 《Journal of Environmental Science and Engineering》 2011年第11期1407-1413,共7页
The study was conducted to identify indoor air quality and the level of thermal comfort in various selected locations in Faculty of Engineering and Built Environment (FKAB), University Kebangsaan Malaysia (UKM) wi... The study was conducted to identify indoor air quality and the level of thermal comfort in various selected locations in Faculty of Engineering and Built Environment (FKAB), University Kebangsaan Malaysia (UKM) with built-up area of 250,936 fie. The indoor air quality and thermal comfort were measured at various selected locations by using indoor air quality equipment (Thermal Comfort SERI). The thermal comfort assessments are based on Malaysian Code of Practice Indoor Air Quality 2005 and Moderate Thermal Environments-Determination of the PMV and PPD indices specification of the condition for thermal comfort (ISO7730:1994) From the data analysis, the FKAB building is considered inadequately vented space. The concentration of CO2 for all sampling area evaluated exceeds the recommended concentration (〉 1000 ppm). The ventilation system used in FKAB building is designed by delivering fix amount of fresh air into building from external building without consideration on the number of occupants. This common ventilation design will increase the amount of CO2 dramatically all day long and these reflect the inefficiency of energy used. The faculty needs to be equipped with a comprehensive energy management system that can allow detailed documentation of continuous performance of all energy system and consumption in the building. 展开更多
关键词 Energy efficiency indoor air quality comfort survey FKAB UKM
下载PDF
Decline of VOC Concentrations with the Aging of Houses in Japan
3
作者 Motoya Hayashi Haruki Osawa 《Journal of Environmental Protection》 2013年第12期33-40,共8页
The purpose of this investigation is to know the long-term characteristics of VOC concentrations in houses built before the building code in 2003 and to clarify the countermeasures against indoor air pollution in the ... The purpose of this investigation is to know the long-term characteristics of VOC concentrations in houses built before the building code in 2003 and to clarify the countermeasures against indoor air pollution in the houses already built. For example, the improvements of living habits, ventilation and the remove of building materials. The concentrations of VOCs were measured in these houses in summer and winter from 2000 to 2005. The results showed that the concentration of formaldehyde decreased in the first year. After that the decline of the concentration was not seen and the concentration changed only with the temperature. The characteristics of decline were thought to be caused by two sorts of emission. One is an emission of concealed formaldehyde in the process of material production and the other is an emission with the generation of formaldehyde from adhesives of urea resin and moisture. The concentration of toluene decreased rapidly in the first year. The concentrations of xylene, ethyl-benzene and styrene showed a similar change. But the concentrations of acetaldehyde which were measured from the summer of 2002 did not decrease and its concentration in some houses was higher than the guideline even in the winter of 2005. 展开更多
关键词 INDOOR air Quality VOC Passive Sampling QUESTIONNairE survey STATISTICS Analysis
下载PDF
Innovation key technologies two magic weapons for successful Gree
4
作者 Cao Xinxin 《China Standardization》 2019年第5期54-59,共6页
W hat brand will you choose when buying an air conditioner? If you conduct a survey am ong global consumers, about one out of five may choose Gree, a Chinese electric appliance brand. Astonished? Don't be.
关键词 air CONDITIONER survey ELECTRIC APPLIANCE
下载PDF
厦门市公共场所集中空调通风系统卫生状况及评价 被引量:10
5
作者 黄小金 叶秀恋 +5 位作者 白宏 王宝珍 陈剑锋 黄培枝 洪华荣 王娟 《旅行医学科学》 2010年第3期12-16,共5页
目的调查评价厦门市公共场所集中空调通风系统污染状况,为卫生管理提供依据。方法依据《公共场所集中空调通风系统卫生规范》(卫监督发〔2006〕58号)的要求,于2009年5月~9月对厦门市四星级以上宾馆及大型公共场所共43家集中空调进行卫... 目的调查评价厦门市公共场所集中空调通风系统污染状况,为卫生管理提供依据。方法依据《公共场所集中空调通风系统卫生规范》(卫监督发〔2006〕58号)的要求,于2009年5月~9月对厦门市四星级以上宾馆及大型公共场所共43家集中空调进行卫生检测,检测送风中可吸入颗粒物(PM10)和细菌总数、真菌总数、β-溶血性链球菌;风管内表面积尘量和积尘中细菌总数、真菌总数β-溶血性链球菌以及检测冷却塔水中的嗜肺军团菌。结果公共场所集中空调送风系统可吸入颗粒物(PM10)合格率93.55%,细菌总数合格率为90.32%,真菌总数合格率为96.77%,风管内表面积尘量合格率为98.49%,风管内细菌总数合格率为97.24%,风管内真菌合格率为94.97%,送风系统及风管内β-溶血性链球菌均未检出,冷却塔水中的嗜肺军团菌检出率为29.17%。结论公共场所集中空调通风系统存在一定程度的污染,应加强卫生管理。 展开更多
关键词 air pollution Heating-ventilating-air conditioning system Health survey
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部