CONDENSING HEAT TRANSFER IN AN ADVANCED TWO-PHASE CLOSED THERMOSYPHON 被引量:1
1
作者 李修伦 闻建平 +1 位作者 单岩昆 黄鸿鼎 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1996年第1期88-92,共5页
1 INTRODUCTIONClosed thermosyphon has been developed to enhance heat transfer and recover wasteheat in various process industries [1,2].Stimulated by this success,a new type oftwo-phase closed thermosyphon was designe... 1 INTRODUCTIONClosed thermosyphon has been developed to enhance heat transfer and recover wasteheat in various process industries [1,2].Stimulated by this success,a new type oftwo-phase closed thermosyphon was designed by inserting respectively two inner tubesinto the thermosyphon,one in the boiling section and the other in the condensing sec-tion.The two-phase flow boiling heat transfer coefficient was calculated successfully onthe basis of Chen’s dual-mechanism [3].A boiling heat transfer model for thetwo-phase closed thermosyphon with an inner tube in the boiling section was pro- 展开更多
关键词 two-phase closed thermosyphon heat TRANSFER NARROW ANNULUS
下载PDF
Performance analyses of two-phase closed thermosyphons for road embankments in the high-latitude permafrost regions
2
作者 WANG Guan-fu LIN Chuang +3 位作者 ZHU Long FENG De-cheng XIN Yang-yang ZHANG Feng 《Journal of Mountain Science》 SCIE CSCD 2023年第11期3138-3153,共16页
Two-phase closed thermosyphons(TPCTs)are widely used in infrastructure constructions in permafrost regions.Due to different climatic conditions,the effectiveness of TPCT will also be different,especially in the extrem... Two-phase closed thermosyphons(TPCTs)are widely used in infrastructure constructions in permafrost regions.Due to different climatic conditions,the effectiveness of TPCT will also be different,especially in the extremely cold region of the Da Xing'anling Mountains.In this study,a series of three-dimensional finite element TPCT embankment models were established based on the ZhanglingMohe highway TPCT test section in Da Xing'anling Mountains,and the thermal characteristics and the cooling effect of the TPCTs were analyzed.The results indicated that the TPCTs installed in the northeastern high-latitude regions is effective in cooling and stabilizing the embankment.The working cycle of the TPCTs is nearly 7 months,and the cooling range of the TPCTs can reach 3 m in this region.However,due to the extremely low temperature,the TPCT generates a large radial gradient in the permafrost layer.Meanwhile,by changing the climate conditions,the same type of TPCT embankment located in the Da Xing'anling Mountains,the Xiao Xing'anling Mountains,and the Qinghai-Tibet Plateau permafrost regions were simulated.Based on the comparison of the climate differences between the Qinghai-Tibet Plateau and Northeast China,the differences in the effectiveness of TPCTs were studied.Finally,the limitations of using existing TPCTs in high-latitude permafrost regions of China were discussed and the potential improvements of the TPCT in cold regions were presented. 展开更多
关键词 PERMAFROST Highway embankment two-phase closed thermosyphon Numerical simulation Climatic condition Cooling performance
下载PDF
Temperature distribution of fluids in a two-section two-phase closed thermosyphon wellbore
3
作者 Zhang Yufeng Zhao Lun +5 位作者 Fan Zifei Wu Xiaodong Fu Libing Xu Bifeng Kong Fanshun Jiang Shengdong 《Petroleum Science》 SCIE CAS CSCD 2014年第2期287-292,共6页
Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in... Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in wellbores, increase the temperature of fluid in wellheads and even more effectively reduce the failure rate of conventional TPCT wellbores. Heat transfer performance of two-section TPCT wellbores is affected by working medium, combination mode and oil flow rate. Different working media are introduced into the upper and lower TPCTs, which may achieve a better match between the working medium and the temperature field in the wellbores. Interdependence exists between the combination mode and the flow rate of the oil, which affects the heat transfer performance of a two-section TPCT wellbore. The experimental results show that a two-section TPCT wellbore, with equal upper and lower TPCTs respectively filled with Freon and methanol, has the best heat transfer performance when the oil flow rate is 200 L/h. 展开更多
关键词 Two-section two-phase closed thermosyphon temperature distribution combination mode heat transfer performance
下载PDF
Climate warming is likely to weaken the performance of two-phase closed thermosyphon on the Qinghai-Tibet Plateau
4
作者 Guan-Li JIANG Zi-Teng FU +4 位作者 Xin-Yu MEN Hong-Ting ZHAO Si-Ru GAO Yong-Zhi LI Qing-Bai WU 《Advances in Climate Change Research》 SCIE CSCD 2024年第1期90-100,共11页
Over the years,numerous geotechnical approaches have been implemented to mitigate the adverse effects of climate warming on various infrastructures in the permafrost region of the Qinghai-Tibet Plateau(QTP),such as th... Over the years,numerous geotechnical approaches have been implemented to mitigate the adverse effects of climate warming on various infrastructures in the permafrost region of the Qinghai-Tibet Plateau(QTP),such as the Qinghai-Tibet Highway and Railway,and achieved the expected engineering outcomes.However,little attention has been given to whether the performance of these geotechnical approaches has changed during the ongoing process of climate warming.To investigate the performance variation of one of these geotechnical approaches,which is two-phase closed thermosyphon(TPCT),during sustained climate warming,we conducted a statistical analysis of soil temperature monitoring data in 2003-2020 from eight regular embankments and six TPCT embankments in our permafrost monitoring network.The results indicate that TPCT undeniably has a cooling effect on the permafrost beneath embankments,even rapidly eliminated previously formed taliks beneath embankment.However,further analysis reveals that the performance of TPCT has been weakening during sustained climate warming,which has confirmed by the re-forming of the taliks beneath embankment where they had been previously eliminated.Based on the current understanding,we attributed the weakening of thermosyphon performance to a significant reduction in the air temperature freezing index caused by ongoing climate warming.Through this study,we aimed to draw attention to the evolving performance of geotechnical approaches in permafrost regions amid climate warming,prompting necessary engineering innovations to address this situation and ensure the sustainable development of the permafrost region on the QTP. 展开更多
关键词 two-phase closed thermosyphon Climate warming Supra-permafrost talik Permafrost degradation Qinghai-Tibet Highway
原文传递
Dynamic simulation and experimental validation of a two-phase closed thermosyphon for geothermal application 被引量:3
5
作者 Johann-Christoph Ebeling Xing Luo +2 位作者 Stephan Kabelac Sebastian Luckmann Horst Kruse 《Propulsion and Power Research》 SCIE 2017年第2期107-116,共10页
The heat transfer perfonmance of a vertical two-phase closed thermosyphon(TPCT)used in a geothermal heat pump was experimentally investigated.The TPCT is a verticalplain steel pipe with inner diameter of 114 mm and bo... The heat transfer perfonmance of a vertical two-phase closed thermosyphon(TPCT)used in a geothermal heat pump was experimentally investigated.The TPCT is a verticalplain steel pipe with inner diameter of 114 mm and bored 368 m deep underground.Carbon dioxide(CO_(2))is used as working fluid.In the TPCT there is no condensation section.CO_(2)is condensed by the evaporator pf the heat pump,flows into the head of the TPCT and nuns down as a falling film along the inner wall of the pipe.For the heat transfer simulation in the TPCT,a quasi-dynamic model in which the mass transfer between the liquid and vapor phases as well as the conduction heat transfer from the surrounding soil towards the pipe is treated dynamically.However the film flow modeling is based on the Nusselt theory of frilm condenssation.The compauison of the experimental data with the numerical simulation is presented and discussed. 展开更多
关键词 two-phase closed thermosyphon(TPCT) Geothermal thermosy-phon Falling film evaporation Geothermal heat pump Dynamic simulation Experimental validation
原文传递
Application of a concrete thermal pile in cooling the warming permafrost under climate change 被引量:1
6
作者 Yun-Hu SHANG Fu-Jun NIU +2 位作者 Guo-Yu LI Jian-Hong FANG Ze-Yong GAO 《Advances in Climate Change Research》 SCIE CSCD 2024年第1期170-183,共14页
Permafrost degradation caused by climate warming is posing a serious threat to the stability of cast-in-place pile foundations in warm permafrost regions.Ambient cold energy can be effectively utilized by two-phase cl... Permafrost degradation caused by climate warming is posing a serious threat to the stability of cast-in-place pile foundations in warm permafrost regions.Ambient cold energy can be effectively utilized by two-phase closed thermosyphons(TPCTs)to cool the permafrost.Therefore,we installed TPCTs in a cast-in-place pile foundation to create a unique structure called a thermal pile,which effectively utilizes the TPCTs to regulate ground temperature.And we conducted a case study and numerical simulation to exhibit the cooling performance,and optimize the structure of the thermal pile.The purpose of this study is to promote the application of thermal piles in unstable permafrost regions.Based on the findings,the thermal pile operated for approximately 53%of the entire year and effectively reduced the deep ground temperature at a rate of at least-0.1℃per year.Additionally,it successfully raised the permafrost table that is 0.35 m shallower than the natural ground level.These characteristics prove highly beneficial in mitigating the adverse effects of permafrost degradation and enhancing infrastructure safety.Expanding the length of the condenser section and the diameter of the TPCT in a suitable manner can effectively enhance the cooling capability of the thermal pile and ensure the long-term mechanical stability of the pile foundation even under climate warming. 展开更多
关键词 Heat transfer Cold energy Warm permafrost two-phase closed thermosyphons Cast-in-place pile foundation
原文传递
Thermal and mechanical characteristics of a thermal pile in permafrost regions 被引量:3
7
作者 Yun-Hu SHANG Fu-Jun NIU +2 位作者 Kun YUAN Tian SUN Li-Bo WU 《Advances in Climate Change Research》 SCIE CSCD 2023年第2期255-266,共12页
Cast-in-place pile foundations are widely used in permafrost regions to support buildings.The stability of cast-in-place pile foundations is highly sensitive to permafrost thermal regime changes.Permafrost degradation... Cast-in-place pile foundations are widely used in permafrost regions to support buildings.The stability of cast-in-place pile foundations is highly sensitive to permafrost thermal regime changes.Permafrost degradation caused by climate change is increasing the disaster risk of castin-place pile foundations.However,proactive cooling methods for cast-in-place pile foundations are seldom reported.The cold energy produced by two-phase closed thermosyphons(TPCTs)can efficiently prevent the permafrost thermal regime from being disturbed by engineering activities and climate change.TPCTs were installed in a concrete pile forming a thermal pile.Then,a model experiment was conducted to explore the thermal regime,influence scope,dissipation process of cold energy,and freezing strength of the thermal pile.The results indicated that the thermal pile may significantly cool the foundation soil.Most of cold energy produced by the thermal pile dissipated during the warm period,and the cooling scope of the thermal pile can cover the area within a 40 cm(twice the pile diameter)radius around the pile.Additionally,the TPCTs can significantly improve freezing strength between the thermal pile and frozen soil.The lesson learned from this study can provide a new approach to control the thermal regime of cast-in-place pile foundation in permafrost,which was of valuable to the construction of pile foundations in cold regions. 展开更多
关键词 Pile foundation Cold energy two-phase closed thermosyphon Freezing strength Permafrost regions
原文传递
基于格子玻尔兹曼的两相闭式环路热虹吸研究
8
作者 郑雯瀚 洪芳军 《工程热物理学报》 EI CAS CSCD 北大核心 2021年第2期462-467,共6页
两相闭式环路热虹吸(CLTPT)形成定向循环的动力来源是重力在蒸发器和冷凝器之间形成的压力差。本文通过修改Gong-Cheng相变LBM模型中重力项计算方式,成功模拟了CLTPT在沸腾和凝结相变共同作用下产生的自驱动现象,揭示了不同充液率下的... 两相闭式环路热虹吸(CLTPT)形成定向循环的动力来源是重力在蒸发器和冷凝器之间形成的压力差。本文通过修改Gong-Cheng相变LBM模型中重力项计算方式,成功模拟了CLTPT在沸腾和凝结相变共同作用下产生的自驱动现象,揭示了不同充液率下的多种两相流型的存在。发现对于本文设计的热虹吸管结构,在初始状态液相覆盖全部蒸发段的前提下,充液率越小,CLTPT的周期性越复杂,越难达到稳定运行状态,系统自循环时均质量流量更小,同时蒸发段时均温度更低。 展开更多
关键词 两相闭式环路热虹吸 格子BOLTZMANN方法 充液率 两相流型