Production of glass-ceramics by sintering the molten slag obtained from electric arc furnace treatment of fly ash was investigated. The effect of washing pretreatment prior to melting the fly ash on the microstructure...Production of glass-ceramics by sintering the molten slag obtained from electric arc furnace treatment of fly ash was investigated. The effect of washing pretreatment prior to melting the fly ash on the microstructure and properties of the glass-ceramics was examined. The results show that washing pretreatment of fly ash can decrease alkali metal chloride and increase network former in fly ash, which results in the increase of peak crystallization temperature of parent glass and strengthening of properties of bending strength and chemical stability of the glass-ceramics. The optimal heat treatment temperature for parent glass of washed fly ash is 1 173 K, at which the crystalline phase of glass-ceramics is composed of gelignite (Ca2A12SiO7) and akermanite (Ca2MgSi207). Glass-ceramics produced at optimal heat treatment temperature are excellent in term of the physical and chemical properties and leaching characteristics, indicating attractive potential as substitute of nature materials.展开更多
CO2 removal from biogas by water washing system was investigated with various parameters, including liquid/ gas ratio, pressure, temperature, and CO2 content. The results indicate that CO2 removal ratio could reach 34...CO2 removal from biogas by water washing system was investigated with various parameters, including liquid/ gas ratio, pressure, temperature, and CO2 content. The results indicate that CO2 removal ratio could reach 34.6%- 94.2% as liquid/gas ratio increased from 0.14 to 0.50. Increasing pressure (from 0.8 to 1.2 MPa) could improve gas purification with a constant inflow rate of gas. Temperature played a key role in the process and lower temper- ature in absorption tower was beneficial for reducing CO2 content. CO2 removal ratio could reach 24.4%-83.2% when CO2 content in the simulated gas was 25%-45%. The lowest CO2 content after absorption was 2.6% at 1.2 MPa with 400 L·h-1 gas flow and 200 L·h-1 water flow, which meets the requirement of CO2 content in natural Ras for vehicle fuel.展开更多
An old automotive industrial site located at Mexico City with many years of operation and contaminated with heavy oil hydrocarbons, particularly spent oils, was assessed for restoration using the surfactant enhanced s...An old automotive industrial site located at Mexico City with many years of operation and contaminated with heavy oil hydrocarbons, particularly spent oils, was assessed for restoration using the surfactant enhanced soil washing (SESW) process. The main goal of this study was to characterize the contaminated soil in terms of TPHs, BTEX, PAHs, and metals contents as well as microbiologically (total heterotrophs and specific degrading microorganisms). We also aimed to determine the surfactant type and concentration to be used in the SESW process for the automotive waste oil contaminated soil. At the end, sixteen kg of contaminated soil were washed and the produced wastewater (approximately 40 L) was characterized in terms of COD, BOD;solids, and other physico-chemical parameters. The soil contained about 14,000 mg of TPH/kg soil (heavy fraction), 0.13 mg/kg of benzo (k) fluoranthene and 0.07 mg/kg of benzo (a) pyrene as well as traces of some metals. Metals concentrations were always under the maximum concentration levels suggested by Mexican regulations. 15 different surfactants were used to identify the one with the capability to achieve the highest TPH removal. Surfactants included 5 anionics, 2 zwitterionic, 5 nonionics and 3 natural gums. Sulfopon 30 at a concentration of 0.5% offered the best surfactant performance. The TPH removals employing the different surfactants were in the range from 38% to 68%, in comparison to the soil washing with water (10% of TPH removal). Once the surfactant was selected, 70 kg of soil were washed and the resulting water contained approximately 1300 mg/L of COD, 385 mg/L of BOD (BOD/COD = 0.29), 122 mg/L of MBAS, and 212 mg/L of oil and greases, among other contaminants.展开更多
Gross compositions and distribution of saturated and aromatic hydrocarbons in Carboniferous sandstone reservoir rocks in oil and water zones for Tazhong\|10 well of the Zhongyang Uplift in the Tarim Basin were studied...Gross compositions and distribution of saturated and aromatic hydrocarbons in Carboniferous sandstone reservoir rocks in oil and water zones for Tazhong\|10 well of the Zhongyang Uplift in the Tarim Basin were studied in detail by means of Rock\|Eval pyrolysis, thin\|chromatograph\|flame ionization detection (TLC\|FID), gas chromatography, gas chromatography\|mass spectrometry. The results suggest that the gross composition of reservoir hydrocarbons between the oil zone and the water zone show significant differences. Water washing has a dramatic effect on saturated hydrocarbon biomarkers, especially drimane series compounds. Drimane series compounds in the water zone have been depleted completely. However, the contents of tricyclic diterpanes and pentacyclic triterpanes tend to decrease slightly, but the water\|zone reservoir hydrocarbons contain a large amount of gammacerane. This suggests that gammacerane be more resistant to water washing than diterpanes and homohopanes. The contents of pregnane, homopregrane, diasteranes relatively decrease as a result of water washing. Water washing has a noticeable effect on polycyclic aromatic hydrocarbon compounds, especially aromatic sulfur compounds, and the contents of dibenzothiophene series compounds and benzonaphiothiophene decrease significantly as a result of water washing. However, the contents of bicyclic and tricyclic aromatic hydrocarbons decrease slightly and those of tetracyclic and pentacyclic aromatic hydrocarbons, especially benzofluoranthene and benzopyrenes, increase markedly owing to a decrease in light aromatic hydrocarbons as a result of water washing.展开更多
Pretreatment before biomass combustion is significant for its efficient utilization and that combined water washing and carbonization can be efficient.An agricultural processing residues sesame stalk was selected and ...Pretreatment before biomass combustion is significant for its efficient utilization and that combined water washing and carbonization can be efficient.An agricultural processing residues sesame stalk was selected and carried out two pretreatments separately,i.e.,water washing-torrefaction(W-T)and torrefaction-water washing(T-W),to explore the effect on the fuel properties,combustion characteristics and particulate matter(PM)emission.The obtained biochar was also combusted under air and oxy50(CO_(2):O_(2)=50:50)conditions for the sake of investigating the effect of pretreatment and combustion atmosphere.The results indicate that,W-T and T-W both not only have great effect on the improvement of fuel properties but also reduce the content of water-soluble elements like K,Cl,etc.Due to the difference in hydrophobicity,the biochar obtained by W-T have the optimal fuel properties.At the same time,the pretreatment also hinder the combustion in a certain extent in which the comprehensive combustion characteristics(SN)show a downward trend.Furthermore,both two pretreatments have obvious benefit on the reduction of PM_(1)emission and W-T have the best effect related to the higher removal efficiency of inorganic elements(especially K+Na+Cl+S).Under oxy50 condition,the oxygen concentration and combustion temperature is higher,improving the sulfation of K and vaporization of Ca,P and Mg which result in weakening in the pretreatment reduction effect on PM_(1)emission.展开更多
The ability to predict the behaviour of a gas turbine engine and optimize its performance is critical in eco-nomic, thermal and condition monitoring studies. Having identified fouling as one of the major sources of co...The ability to predict the behaviour of a gas turbine engine and optimize its performance is critical in eco-nomic, thermal and condition monitoring studies. Having identified fouling as one of the major sources of compressor and therefore gas turbine deterioration, a computer-based engine model was developed to optimize the performance of gas turbines. The paper thus presents an analysis of compressor hand cleaning, on and offline compressor washing to actualize the technique using a computer program in Visual Basic programming language with data collected over a period of fifteen weeks for 2 gas turbine plants GT1 and GT2. The results of the data collected, when collated, shows that after washing, the overall operational efficiency changed from 39.2% to 46.25%. To optimize the performance of gas turbine engines, it is therefore recommended that operators should perform a combination of compressor hand cleaning, offline and online washing simultaneously.展开更多
Water-washing removes fluoride from Antarctic krill but produces large volumes of wash water containing water-soluble proteins and fluoride. The freeze concentration method was tested to determine if it could be used ...Water-washing removes fluoride from Antarctic krill but produces large volumes of wash water containing water-soluble proteins and fluoride. The freeze concentration method was tested to determine if it could be used to recover water-soluble proteins while leaving the fluoride in solution. After freezing and thawing the wash water, protein and fluoride contents of the thawed fractions were determined to explore the melting regularity of components in the wash water. The highest concentration factors of protein and fluoride were obtained after 80 min of thawing, such as 1.48 ± 0.06 and 1.35 ± 0.04 times, respectively. The free amino-nitrogen(FAN) content and sodium dodecyl sulfate-polyacrylamide gel electrophoresis pattern results revealed that the highest concentrations of all ingredients were obtained after 80 min of the process. The degree of hydrolysis of all fractions from the thawing process fluctuated in a narrow range around 12% during the entire process, indicating that the thawing order did not change with various proteins or time during the entire thawing course. These results demonstrate that the freeze concentration method can be used to concentrate protein solutions, even those with fluoride. It was concluded that condensation was achieved and no ingredient could be separated, regardless of fluoride, amino acids, or different proteins in the water.展开更多
Tunnel wash waters characterize all waters that run off after washing procedures of tunnels are performed.These waters represent a wide spectrum of organic and inorganic pollutants,such as polycyclic aromatic hydrocar...Tunnel wash waters characterize all waters that run off after washing procedures of tunnels are performed.These waters represent a wide spectrum of organic and inorganic pollutants,such as polycyclic aromatic hydrocarbons(PAHs)and toxic metals.Removal of such contaminants from water runoff was investigated using laboratory tests after washing procedure was performed on two road tunnels in eastern Norway(Hanekleiv and Bragernes).Due to diverse character of both,treatment media and treated wash waters, the wh...展开更多
Durable superomniphobic surfaces are desirable for their practical applications,including selfcleaning,non-fouling,protective clothing and the separation of liquids.The plasma-induced polymerization of environmentally...Durable superomniphobic surfaces are desirable for their practical applications,including selfcleaning,non-fouling,protective clothing and the separation of liquids.The plasma-induced polymerization of environmentally friendly C6 from a perfluoralkyl methlacrylate copolymer emulsion,AG-E081,was performed and a durable omniphobic fabric was achieved.C6 is an ecological alternative to C8(eight CF2 groups)fluorinated compounds,and it was thereafter successfully incorporated into aramid fabric to achieve a durable superomniphobic surface.The fabric became water and oil repellent with an extremely high water contact angle of 180°.As tested by the water spray AATCC test and hydrocarbon resistance test,the as-prepared fabric gained 100°(ISO 5)and grade number 4 respectively.Furthermore,the fabrics also showed significantly improved washing durability after ten washing cycles.By scanning electron microscopy(SEM),Fourier-transform infrared spectroscopy(FTIR)and x-ray photoelectron spectroscopy(XPS)tests,it is indicated that the durable superomniphobicity can be attributed to the roughness and activation of the aramid surface by the plasma pre-treatment,which induces more adsorption and chemical graft of the C6 copolymer.展开更多
In the first part of the article, the column and the bag experiments concerning removal of polycyclic aromatic hydrocarbons (PAHs) and nonpolar oil (NPO) from tunnel wash waters using organic sorbent materials have be...In the first part of the article, the column and the bag experiments concerning removal of polycyclic aromatic hydrocarbons (PAHs) and nonpolar oil (NPO) from tunnel wash waters using organic sorbent materials have been described. This part presents the results of removal of toxic metals. The metals of concern (Al, As, Cd, Cr, Cu, Fe, Pb, Mo, Ni, and Zn) were selected based on the priority toxicant pollutants defined in surface water quality criteria. Concentrations of these metals in the collected effluent...展开更多
This paper concerns with the treatment of bagasse wash water, which is generated after washing the stored bagasse before its use in the paper manufacture. The bagasse wash water, treated earlier in open lagoons, is no...This paper concerns with the treatment of bagasse wash water, which is generated after washing the stored bagasse before its use in the paper manufacture. The bagasse wash water, treated earlier in open lagoons, is now treated by the anaerobic process using UASB reactor. This study, based upon an operating unit, shows that the UASB reactor reduces COD of wash water by 85% - 90%, and results in significant emission reductions. Economic analysis carried out by using financial indicators such as DSCR, Payback period and IRR reveals very attractive rate of returns and thus, greatly reduces the risks in financing such projects by the financial institutions.展开更多
基金Funded by the National Natural Science Foundation of China(No.20806051)the Key Laboratory of Education Ministry for Solid Waste Management and Environment Safety(No.SWMES-2010-07)the Science and Technology Project of Housing and Urban-Rural Ministry(No.2010-K4-2)
文摘Production of glass-ceramics by sintering the molten slag obtained from electric arc furnace treatment of fly ash was investigated. The effect of washing pretreatment prior to melting the fly ash on the microstructure and properties of the glass-ceramics was examined. The results show that washing pretreatment of fly ash can decrease alkali metal chloride and increase network former in fly ash, which results in the increase of peak crystallization temperature of parent glass and strengthening of properties of bending strength and chemical stability of the glass-ceramics. The optimal heat treatment temperature for parent glass of washed fly ash is 1 173 K, at which the crystalline phase of glass-ceramics is composed of gelignite (Ca2A12SiO7) and akermanite (Ca2MgSi207). Glass-ceramics produced at optimal heat treatment temperature are excellent in term of the physical and chemical properties and leaching characteristics, indicating attractive potential as substitute of nature materials.
基金Supported by the National Technology Research and Development Program of China(2008AA062402)the China-US International Cooperation Project(2011DFA90800)the Ministry of Science and Technology,China
文摘CO2 removal from biogas by water washing system was investigated with various parameters, including liquid/ gas ratio, pressure, temperature, and CO2 content. The results indicate that CO2 removal ratio could reach 34.6%- 94.2% as liquid/gas ratio increased from 0.14 to 0.50. Increasing pressure (from 0.8 to 1.2 MPa) could improve gas purification with a constant inflow rate of gas. Temperature played a key role in the process and lower temper- ature in absorption tower was beneficial for reducing CO2 content. CO2 removal ratio could reach 24.4%-83.2% when CO2 content in the simulated gas was 25%-45%. The lowest CO2 content after absorption was 2.6% at 1.2 MPa with 400 L·h-1 gas flow and 200 L·h-1 water flow, which meets the requirement of CO2 content in natural Ras for vehicle fuel.
文摘An old automotive industrial site located at Mexico City with many years of operation and contaminated with heavy oil hydrocarbons, particularly spent oils, was assessed for restoration using the surfactant enhanced soil washing (SESW) process. The main goal of this study was to characterize the contaminated soil in terms of TPHs, BTEX, PAHs, and metals contents as well as microbiologically (total heterotrophs and specific degrading microorganisms). We also aimed to determine the surfactant type and concentration to be used in the SESW process for the automotive waste oil contaminated soil. At the end, sixteen kg of contaminated soil were washed and the produced wastewater (approximately 40 L) was characterized in terms of COD, BOD;solids, and other physico-chemical parameters. The soil contained about 14,000 mg of TPH/kg soil (heavy fraction), 0.13 mg/kg of benzo (k) fluoranthene and 0.07 mg/kg of benzo (a) pyrene as well as traces of some metals. Metals concentrations were always under the maximum concentration levels suggested by Mexican regulations. 15 different surfactants were used to identify the one with the capability to achieve the highest TPH removal. Surfactants included 5 anionics, 2 zwitterionic, 5 nonionics and 3 natural gums. Sulfopon 30 at a concentration of 0.5% offered the best surfactant performance. The TPH removals employing the different surfactants were in the range from 38% to 68%, in comparison to the soil washing with water (10% of TPH removal). Once the surfactant was selected, 70 kg of soil were washed and the resulting water contained approximately 1300 mg/L of COD, 385 mg/L of BOD (BOD/COD = 0.29), 122 mg/L of MBAS, and 212 mg/L of oil and greases, among other contaminants.
文摘Gross compositions and distribution of saturated and aromatic hydrocarbons in Carboniferous sandstone reservoir rocks in oil and water zones for Tazhong\|10 well of the Zhongyang Uplift in the Tarim Basin were studied in detail by means of Rock\|Eval pyrolysis, thin\|chromatograph\|flame ionization detection (TLC\|FID), gas chromatography, gas chromatography\|mass spectrometry. The results suggest that the gross composition of reservoir hydrocarbons between the oil zone and the water zone show significant differences. Water washing has a dramatic effect on saturated hydrocarbon biomarkers, especially drimane series compounds. Drimane series compounds in the water zone have been depleted completely. However, the contents of tricyclic diterpanes and pentacyclic triterpanes tend to decrease slightly, but the water\|zone reservoir hydrocarbons contain a large amount of gammacerane. This suggests that gammacerane be more resistant to water washing than diterpanes and homohopanes. The contents of pregnane, homopregrane, diasteranes relatively decrease as a result of water washing. Water washing has a noticeable effect on polycyclic aromatic hydrocarbon compounds, especially aromatic sulfur compounds, and the contents of dibenzothiophene series compounds and benzonaphiothiophene decrease significantly as a result of water washing. However, the contents of bicyclic and tricyclic aromatic hydrocarbons decrease slightly and those of tetracyclic and pentacyclic aromatic hydrocarbons, especially benzofluoranthene and benzopyrenes, increase markedly owing to a decrease in light aromatic hydrocarbons as a result of water washing.
基金the National Key Research and Development Program of China(No.2016YFB0600605)Hubei Province Technology Innovation Project(No.2018AHB017)National Natural Science Foundation of China(No.52076091).
文摘Pretreatment before biomass combustion is significant for its efficient utilization and that combined water washing and carbonization can be efficient.An agricultural processing residues sesame stalk was selected and carried out two pretreatments separately,i.e.,water washing-torrefaction(W-T)and torrefaction-water washing(T-W),to explore the effect on the fuel properties,combustion characteristics and particulate matter(PM)emission.The obtained biochar was also combusted under air and oxy50(CO_(2):O_(2)=50:50)conditions for the sake of investigating the effect of pretreatment and combustion atmosphere.The results indicate that,W-T and T-W both not only have great effect on the improvement of fuel properties but also reduce the content of water-soluble elements like K,Cl,etc.Due to the difference in hydrophobicity,the biochar obtained by W-T have the optimal fuel properties.At the same time,the pretreatment also hinder the combustion in a certain extent in which the comprehensive combustion characteristics(SN)show a downward trend.Furthermore,both two pretreatments have obvious benefit on the reduction of PM_(1)emission and W-T have the best effect related to the higher removal efficiency of inorganic elements(especially K+Na+Cl+S).Under oxy50 condition,the oxygen concentration and combustion temperature is higher,improving the sulfation of K and vaporization of Ca,P and Mg which result in weakening in the pretreatment reduction effect on PM_(1)emission.
文摘The ability to predict the behaviour of a gas turbine engine and optimize its performance is critical in eco-nomic, thermal and condition monitoring studies. Having identified fouling as one of the major sources of compressor and therefore gas turbine deterioration, a computer-based engine model was developed to optimize the performance of gas turbines. The paper thus presents an analysis of compressor hand cleaning, on and offline compressor washing to actualize the technique using a computer program in Visual Basic programming language with data collected over a period of fifteen weeks for 2 gas turbine plants GT1 and GT2. The results of the data collected, when collated, shows that after washing, the overall operational efficiency changed from 39.2% to 46.25%. To optimize the performance of gas turbine engines, it is therefore recommended that operators should perform a combination of compressor hand cleaning, offline and online washing simultaneously.
基金supported by the Key Research and Development Project of Shandong Province (No.2015 GSF115005)the Huimin Special Fund of Qingdao Municipal Achievement Transformation Plan (No.15-9-2-120NSH)the National Natural Science Foundation of China (No.31101380)
文摘Water-washing removes fluoride from Antarctic krill but produces large volumes of wash water containing water-soluble proteins and fluoride. The freeze concentration method was tested to determine if it could be used to recover water-soluble proteins while leaving the fluoride in solution. After freezing and thawing the wash water, protein and fluoride contents of the thawed fractions were determined to explore the melting regularity of components in the wash water. The highest concentration factors of protein and fluoride were obtained after 80 min of thawing, such as 1.48 ± 0.06 and 1.35 ± 0.04 times, respectively. The free amino-nitrogen(FAN) content and sodium dodecyl sulfate-polyacrylamide gel electrophoresis pattern results revealed that the highest concentrations of all ingredients were obtained after 80 min of the process. The degree of hydrolysis of all fractions from the thawing process fluctuated in a narrow range around 12% during the entire process, indicating that the thawing order did not change with various proteins or time during the entire thawing course. These results demonstrate that the freeze concentration method can be used to concentrate protein solutions, even those with fluoride. It was concluded that condensation was achieved and no ingredient could be separated, regardless of fluoride, amino acids, or different proteins in the water.
文摘Tunnel wash waters characterize all waters that run off after washing procedures of tunnels are performed.These waters represent a wide spectrum of organic and inorganic pollutants,such as polycyclic aromatic hydrocarbons(PAHs)and toxic metals.Removal of such contaminants from water runoff was investigated using laboratory tests after washing procedure was performed on two road tunnels in eastern Norway(Hanekleiv and Bragernes).Due to diverse character of both,treatment media and treated wash waters, the wh...
基金supported by the Fundamental Research Funds for the Central Universities 2232019A3-12National Natural Science Foundation of China(No.11375042)。
文摘Durable superomniphobic surfaces are desirable for their practical applications,including selfcleaning,non-fouling,protective clothing and the separation of liquids.The plasma-induced polymerization of environmentally friendly C6 from a perfluoralkyl methlacrylate copolymer emulsion,AG-E081,was performed and a durable omniphobic fabric was achieved.C6 is an ecological alternative to C8(eight CF2 groups)fluorinated compounds,and it was thereafter successfully incorporated into aramid fabric to achieve a durable superomniphobic surface.The fabric became water and oil repellent with an extremely high water contact angle of 180°.As tested by the water spray AATCC test and hydrocarbon resistance test,the as-prepared fabric gained 100°(ISO 5)and grade number 4 respectively.Furthermore,the fabrics also showed significantly improved washing durability after ten washing cycles.By scanning electron microscopy(SEM),Fourier-transform infrared spectroscopy(FTIR)and x-ray photoelectron spectroscopy(XPS)tests,it is indicated that the durable superomniphobicity can be attributed to the roughness and activation of the aramid surface by the plasma pre-treatment,which induces more adsorption and chemical graft of the C6 copolymer.
基金the Norwegian Public Roads Administration (Statens Vegvesen Vegdirektoratet)Bioforsk programme "Urban Runoff" founded for preparation of this article
文摘In the first part of the article, the column and the bag experiments concerning removal of polycyclic aromatic hydrocarbons (PAHs) and nonpolar oil (NPO) from tunnel wash waters using organic sorbent materials have been described. This part presents the results of removal of toxic metals. The metals of concern (Al, As, Cd, Cr, Cu, Fe, Pb, Mo, Ni, and Zn) were selected based on the priority toxicant pollutants defined in surface water quality criteria. Concentrations of these metals in the collected effluent...
文摘This paper concerns with the treatment of bagasse wash water, which is generated after washing the stored bagasse before its use in the paper manufacture. The bagasse wash water, treated earlier in open lagoons, is now treated by the anaerobic process using UASB reactor. This study, based upon an operating unit, shows that the UASB reactor reduces COD of wash water by 85% - 90%, and results in significant emission reductions. Economic analysis carried out by using financial indicators such as DSCR, Payback period and IRR reveals very attractive rate of returns and thus, greatly reduces the risks in financing such projects by the financial institutions.