The popularization of portable,implantable and wearable microelectronics has greatly stimulated the rapid development of high-power planar micro-supercapacitors(PMSCs).Particularly,the introduction of new functionalit...The popularization of portable,implantable and wearable microelectronics has greatly stimulated the rapid development of high-power planar micro-supercapacitors(PMSCs).Particularly,the introduction of new functionalities(e.g.,high voltage,flexibility,stretchability,self-healing,electrochromism and photo/thermal response)to PMSCs is essential for building multifunctional PMSCs and their smart selfpowered integrated microsystems.In this review,we summarized the latest advances in PMSCs from various functional microdevices to their smart integrated microsystems.Primarily,the functionalities of PMSCs are characterized by three major factors to emphasize their electrochemical behavior and unique scope of application.These include but are not limited to high-voltage outputs(realized through asymmetric configuration,novel electrolyte and modular integration),mechanical resilience that includes various feats of flexibility or stretchability,and response to stimuli(self-healing,electrochromic,photo-responsive,or thermal-responsive properties).Furthermore,three representative integrated microsystems including energy harvester-PMSC,PMSC-energy consumption,and all-in-one selfpowered microsystems are elaborately overviewed to understand the emerging intelligent interaction models.Finally,the key perspectives,challenges and opportunities of PMSCs for powering smart microelectronics are proposed in brief.展开更多
This paper presents a method for designing a class of countermeasures for DPA attacks based on attenuation of current variations. In this class of countermeasures, designers aim at decreasing the dynamic current varia...This paper presents a method for designing a class of countermeasures for DPA attacks based on attenuation of current variations. In this class of countermeasures, designers aim at decreasing the dynamic current variations to reduce the information that can be extracted from the current consumption of secure microsystems. The proposed method is based on a novel formula that calculates the number of current traces required for a successful DPA attack using the characteristics of the microsystem current signal and the external noise of the measurement setup. The different stages of the proposed method are illustrated through designing an example current flattening circuit. Meanwhile validity and applicability of the proposed formula is verified by comparing theoretical results with those obtained experimentally for the example circuit. The proposed formula not only estimates the required level of attenuation for a target level of robustness defined by design requirements, it also predicts the effectiveness of a countermeasure using simulation results therefore dramatically reducing the time to design of secure microsystems.展开更多
Wireless power transmission based on inductive coupling for remotely implanted micro devices has been considered in this paper. The receiving coil, integrated in microsystems and the external transmitting coil compose...Wireless power transmission based on inductive coupling for remotely implanted micro devices has been considered in this paper. The receiving coil, integrated in microsystems and the external transmitting coil compose a loosely coupled transformer. The coupling coefficient was calculated and measured on spacing misalignments. The geometric size of transmitting coil was analyzed for the target of remotely delivering power. The received power was maximized by choosing appropriate value of frequency, tuning capacitance and the load resistance. A conventional full bridge rectifier circuit was employed to convert ac to dc voltage. The received dc power was up to 160 mW with a transmitting vohage of 5 Vrms when the receiving coil was placed at the center of the transmitting coil. This may meet the requirement of some microsystems for high power over a long time.展开更多
JK Microsystems公司推出一种嵌入式功率控制器,把调整,监视和开/关控制安装在比信用卡还要小的平台中。这种PowerNut电源管理板把输入功率控制在现有的器件上,从而简化了电源设计。该板给设计者提供一种包括电压调整,电源开/关时...JK Microsystems公司推出一种嵌入式功率控制器,把调整,监视和开/关控制安装在比信用卡还要小的平台中。这种PowerNut电源管理板把输入功率控制在现有的器件上,从而简化了电源设计。该板给设计者提供一种包括电压调整,电源开/关时间表和电压监视的现成解决方案。从太阳能板或电池传来的电源电压能控制输出1A的电流。展开更多
Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is desi...Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is designed,and a multiimage encryption(MIE)algorithm with row and column confusion and closed-loop bi-directional diffusion is adopted in the paper.While ensuring secure communication of medical image information,people with different security levels have different levels of decryption keys,and differentiated visual effects can be obtained by using the strong sensitivity of chaotic keys.The highest security level can obtain decrypted images without watermarks,and at the same time,patient information and copyright attribution can be verified by obtaining watermark images.The experimental results show that the scheme is sufficiently secure as an MIE scheme with visualized differences and the encryption and decryption efficiency is significantly improved compared to other works.展开更多
BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL system...BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL systems on patient-reported outcomes(PROs)in patients with T1D in real-world clinical practice.In this independent study,we evaluated glycemic parameters and PROs over one year of continuous use of Medtronic’s 670G HCL in real-world clinical practice.AIM To assess the effects of hybrid closed loop system on glycemic control and quality of life in adults with T1D.METHODS We evaluated 71 patients with T1D(mean age:45.5±12.1 years;59%females;body weight:83.8±18.7 kg,body mass index:28.7±5.6 kg/m2,A1C:7.6%±0.8%)who were treated with HCL at Joslin Clinic from 2017 to 2019.We measured A1C and percent of glucose time-in-range(%TIR)at baseline and 12 months.We measured percent time in auto mode(%TiAM)for the last two weeks preceding the final visit and assessed PROs through several validated quality-of-life surveys related to general health and diabetes management.RESULTS At 12 mo,A1C decreased by 0.3%±0.1%(P=0.001)and%TIR increased by 8.1%±2.5%(P=0.002).The average%TiAM was only 64.3%±32.8%and was not associated with A1C,%TIR or PROs.PROs,provided at baseline and at the end of the study,showed that the physical functioning submodule of 36Item Short-Form Health Survey increased significantly by 22.9%(P<0.001).Hypoglycemia fear survey/worry scale decreased significantly by 24.9%(P<0.000);Problem Areas In Diabetes reduced significantly by-17.2%(P=0.002).The emotional burden submodules of dietary diversity score reduced significantly by-44.7%(P=0.001).Furthermore,analysis of Clarke questionnaire showed no increase in awareness of hypoglycemic episodes.WHO-5 showed no improvements in subject’s wellbeing among participants after starting the 670G HCL system.Finally,analysis of Pittsburgh Sleep Quality Index showed no difference in sleep quality,sleep latency,or duration of sleep from baseline to 12 mo.CONCLUSION The use of HCL in real-world clinical practice for one year was associated with significant improvements in A1C,%TIR,physical functioning,hypoglycemia fear,emotional distress,and emotional burden related to diabetes management.However,these changes were not associated with time in auto mode.展开更多
A novel closed-loop control strategy of a silicon microgyroscope (SMG) is proposed. The SMG is sealed in metal can package in drive and sense modes and works under the air pressure of 10 Pa. Its quality factor reach...A novel closed-loop control strategy of a silicon microgyroscope (SMG) is proposed. The SMG is sealed in metal can package in drive and sense modes and works under the air pressure of 10 Pa. Its quality factor reaches greater than l0 000. Self-oscillating and closed-loop methods based on electrostatic force feedback are adopted in both measure and control circuits. Both single side driving and sensing methods are used to simplify the drive circuit. These dual channel decomposition and reconstruction closed loops are applied in sense modes. The testing results demonstrate that useful signals and guadrature signals do not interact with each other because of the decoupling of their phases. Under the condition of a scale factor of 9. 6 mV/((°) .s), in a full measurement range of±300 (°)/s, the zero bias stability reaches 28 (°)/h with a nonlinear coefficient of 400 × 10^-6 and a simulated bandwidth of more than 100 Hz. The overall performance is improved by two orders of magnitude in comparison to that at atmospheric pressure.展开更多
A dynamics-based adaptive control approach is proposed for a planar dual-arm space robot in the presence of closed-loop constraints and uncertain inertial parameters of the payload. The controller is capable of contro...A dynamics-based adaptive control approach is proposed for a planar dual-arm space robot in the presence of closed-loop constraints and uncertain inertial parameters of the payload. The controller is capable of controlling the po- sition and attitude of both the satellite base and the payload grasped by the manipulator end effectors. The equations of motion in reduced-order form for the constrained system are derived by incorporating the constraint equations in terms of accelerations into Kane's equations of the unconstrained system. Model analysis shows that the resulting equations perfectly meet the requirement of adaptive controller design. Consequently, by using an indirect approach, an adaptive control scheme is proposed to accomplish position/attitude trajectory tracking control with the uncertain parameters be- ing estimated on-line. The actuator redundancy due to the closed-loop constraints is utilized to minimize a weighted norm of the joint torques. Global asymptotic stability is proven by using Lyapunov's method, and simulation results are also presented to demonstrate the effectiveness of the proposed approach.展开更多
As the huge computation and easily trapped local optimum in remanufacturing closed-loop supply chain network (RCSCN) design considered, a genetic particle swarm optimization algorithm was proposed. The total cost of c...As the huge computation and easily trapped local optimum in remanufacturing closed-loop supply chain network (RCSCN) design considered, a genetic particle swarm optimization algorithm was proposed. The total cost of closed-loop supply chain was selected as fitness function, and a unique and tidy coding mode was adopted in the proposed algorithm. Then, some mutation and crossover operators were introduced to achieve discrete optimization of RCSCN structure. The simulation results show that the proposed algorithm can gain global optimal solution with good convergent performance and rapidity. The computing speed is only 22.16 s, which is shorter than those of the other optimization algorithms.展开更多
Efficient recycling technology for the rapid growth of spent lithium-ion batteries(LIBs)is essential to tackle the resources and environmental crisis.Hydrometallurgical approach has attracted extensive research due to...Efficient recycling technology for the rapid growth of spent lithium-ion batteries(LIBs)is essential to tackle the resources and environmental crisis.Hydrometallurgical approach has attracted extensive research due to its potential to reduce the consumption of energy and threat to the environment.However,the simultaneous realization of green,efficient and closed-loop recycling is still challenging.Herein,we report a closed-loop and highly efficient approach to recycle lithium cobalt oxide from spent LIBs based on a choline chloride:oxalic acid(ChCl:OA)type deep eutectic solvent(DES).An ultrafast leaching process is observed at 180°C for 10 s with no observable residues.The energy barrier during leaching is calculated to be 113.9 kJ/mol.Noteworthy,the solubility of cobalt ions can be reversibly tuned by simply adding/evaporating deionized water,thus avoiding the addition of precipitant and enabling the easy recovery of the leaching solvent for realizing a closed-loop recycling process.The simultaneous realization of high efficiency,green and closed-loop process is expected to push the DES into practical application for recycling the electrodes of LIBs.展开更多
Ambient suspended particulate matter(PM)(primarily with particle diameter 2.5m or less,i.e.,PM2.5)can adversely affect ecosystems and human health.Currently,optical particle sensors based on light scattering dominate ...Ambient suspended particulate matter(PM)(primarily with particle diameter 2.5m or less,i.e.,PM2.5)can adversely affect ecosystems and human health.Currently,optical particle sensors based on light scattering dominate the portable PM sensing market.However,the light scattering method has poor adaptability to different-sized PM and adverse environmental conditions.Here,we design and develop a portable PM sensing microsystem that consists of a micromachined virtual impactor(VI)for particle separation,a thermophoretic deposition chip for particle collection,and an extended-gate field-effect transistor(FET)for particle analysis.This system can realize on-site separation,collection,and analysis of aerosol particles without being influenced by environmental factors.In this study,the design of the VI is thoroughly analyzed by numerical simulation,and mixtures of different-sized silicon dioxide(SiO2)particles are used in an experimental verification of the performance of the VI and FET.Considering the low cost and compact design of the whole system,the proposed PM analysis microsystem has potential for PM detection under a wide range of conditions,such as heavily polluted industrial environments and for point-of-need outdoor and indoor air quality monitoring.展开更多
The rapid progress of micro/nanoelectronic systems and miniaturized portable devices has tremendously increased the urgent demands for miniaturized and integrated power supplies.Miniaturized energy storage devices(MES...The rapid progress of micro/nanoelectronic systems and miniaturized portable devices has tremendously increased the urgent demands for miniaturized and integrated power supplies.Miniaturized energy storage devices(MESDs),with their excellent properties and additional intelligent functions,are considered to be the preferable energy supplies for uninterrupted powering of microsystems.In this review,we aim to provide a comprehensive overview of the background,fundamentals,device configurations,manufacturing processes,and typical applications of MESDs,including their recent advances.Particular attention is paid to advanced device configurations,such as two-dimensional(2D)stacked,2D planar interdigital,2D arbitrary-shaped,three-dimensional planar,and wire-shaped structures,and their corresponding manufacturing strategies,such as printing,scribing,and masking techniques.Additionally,recent developments in MESDs,including microbatteries and microsupercapacitors,as well as microhybrid metal ion capacitors,are systematically summarized.A series of on-chip microsystems,created by integrating functional MESDs,are also highlighted.Finally,the remaining challenges and future research scope on MESDs are discussed.展开更多
Objective: To evaluate the efficiency of an implanted chip system for the control of heart rate (HR). Methods: The HR was recorded in six conscious Sprague-Dawley (SD) rats. An implanted chip system was designed...Objective: To evaluate the efficiency of an implanted chip system for the control of heart rate (HR). Methods: The HR was recorded in six conscious Sprague-Dawley (SD) rats. An implanted chip system was designed to regulate the HR by stimulating the right cervical vagus nerve according to the feedback of real time HR. Each rat was subjected to 30-min regulation and 30-min recovery. The change of HR during the regulation period was compared with the control. The ECG was recorded during the experiment for 24 h. Results: The ECG signals were successfully recorded during the experiment. The HR was significantly decreased during the period of regulation compared with control (-79.3 ± 34.5, P 〈 0.01, n = 6) and then recovered to normal after regulation. Conclusion: The described implanted chip system can regulate the HR to a designated set point.展开更多
基金the National Natural Science Foundation of China,China (Grant Nos.22125903,51872283,22109040)the“Transformational Technologies for Clean Energy and Demonstration”Strategic Priority Research Program of the Chinese Academy of Sciences (Grant No.XDA21000000)+4 种基金the Dalian Innovation Support Plan for High Level Talents,China (2019RT09)DICP,China (DICP I202032)the Dalian National Laboratory For Clean Energy (DNL),CAS,DNL Cooperation Fund,CAS,China (DNL202016,DNL202019)the Top-Notch Talent Program of Henan Agricultural University,China (30500947)the Joint Fund of the Yulin University and the Dalian National Laboratory for Clean Energy,China (YLU-DNL Fund 2021002,YLU-DNL Fund 2021009)。
文摘The popularization of portable,implantable and wearable microelectronics has greatly stimulated the rapid development of high-power planar micro-supercapacitors(PMSCs).Particularly,the introduction of new functionalities(e.g.,high voltage,flexibility,stretchability,self-healing,electrochromism and photo/thermal response)to PMSCs is essential for building multifunctional PMSCs and their smart selfpowered integrated microsystems.In this review,we summarized the latest advances in PMSCs from various functional microdevices to their smart integrated microsystems.Primarily,the functionalities of PMSCs are characterized by three major factors to emphasize their electrochemical behavior and unique scope of application.These include but are not limited to high-voltage outputs(realized through asymmetric configuration,novel electrolyte and modular integration),mechanical resilience that includes various feats of flexibility or stretchability,and response to stimuli(self-healing,electrochromic,photo-responsive,or thermal-responsive properties).Furthermore,three representative integrated microsystems including energy harvester-PMSC,PMSC-energy consumption,and all-in-one selfpowered microsystems are elaborately overviewed to understand the emerging intelligent interaction models.Finally,the key perspectives,challenges and opportunities of PMSCs for powering smart microelectronics are proposed in brief.
文摘This paper presents a method for designing a class of countermeasures for DPA attacks based on attenuation of current variations. In this class of countermeasures, designers aim at decreasing the dynamic current variations to reduce the information that can be extracted from the current consumption of secure microsystems. The proposed method is based on a novel formula that calculates the number of current traces required for a successful DPA attack using the characteristics of the microsystem current signal and the external noise of the measurement setup. The different stages of the proposed method are illustrated through designing an example current flattening circuit. Meanwhile validity and applicability of the proposed formula is verified by comparing theoretical results with those obtained experimentally for the example circuit. The proposed formula not only estimates the required level of attenuation for a target level of robustness defined by design requirements, it also predicts the effectiveness of a countermeasure using simulation results therefore dramatically reducing the time to design of secure microsystems.
基金National High Technology Research and Development Program of China(863 Program),Grant number:2004AA404013.
文摘Wireless power transmission based on inductive coupling for remotely implanted micro devices has been considered in this paper. The receiving coil, integrated in microsystems and the external transmitting coil compose a loosely coupled transformer. The coupling coefficient was calculated and measured on spacing misalignments. The geometric size of transmitting coil was analyzed for the target of remotely delivering power. The received power was maximized by choosing appropriate value of frequency, tuning capacitance and the load resistance. A conventional full bridge rectifier circuit was employed to convert ac to dc voltage. The received dc power was up to 160 mW with a transmitting vohage of 5 Vrms when the receiving coil was placed at the center of the transmitting coil. This may meet the requirement of some microsystems for high power over a long time.
基金Project supported by the National Natural Science Foundation of China(Grant No.62061014)the Natural Science Foundation of Liaoning province of China(Grant No.2020-MS-274).
文摘Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is designed,and a multiimage encryption(MIE)algorithm with row and column confusion and closed-loop bi-directional diffusion is adopted in the paper.While ensuring secure communication of medical image information,people with different security levels have different levels of decryption keys,and differentiated visual effects can be obtained by using the strong sensitivity of chaotic keys.The highest security level can obtain decrypted images without watermarks,and at the same time,patient information and copyright attribution can be verified by obtaining watermark images.The experimental results show that the scheme is sufficiently secure as an MIE scheme with visualized differences and the encryption and decryption efficiency is significantly improved compared to other works.
文摘BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL systems on patient-reported outcomes(PROs)in patients with T1D in real-world clinical practice.In this independent study,we evaluated glycemic parameters and PROs over one year of continuous use of Medtronic’s 670G HCL in real-world clinical practice.AIM To assess the effects of hybrid closed loop system on glycemic control and quality of life in adults with T1D.METHODS We evaluated 71 patients with T1D(mean age:45.5±12.1 years;59%females;body weight:83.8±18.7 kg,body mass index:28.7±5.6 kg/m2,A1C:7.6%±0.8%)who were treated with HCL at Joslin Clinic from 2017 to 2019.We measured A1C and percent of glucose time-in-range(%TIR)at baseline and 12 months.We measured percent time in auto mode(%TiAM)for the last two weeks preceding the final visit and assessed PROs through several validated quality-of-life surveys related to general health and diabetes management.RESULTS At 12 mo,A1C decreased by 0.3%±0.1%(P=0.001)and%TIR increased by 8.1%±2.5%(P=0.002).The average%TiAM was only 64.3%±32.8%and was not associated with A1C,%TIR or PROs.PROs,provided at baseline and at the end of the study,showed that the physical functioning submodule of 36Item Short-Form Health Survey increased significantly by 22.9%(P<0.001).Hypoglycemia fear survey/worry scale decreased significantly by 24.9%(P<0.000);Problem Areas In Diabetes reduced significantly by-17.2%(P=0.002).The emotional burden submodules of dietary diversity score reduced significantly by-44.7%(P=0.001).Furthermore,analysis of Clarke questionnaire showed no increase in awareness of hypoglycemic episodes.WHO-5 showed no improvements in subject’s wellbeing among participants after starting the 670G HCL system.Finally,analysis of Pittsburgh Sleep Quality Index showed no difference in sleep quality,sleep latency,or duration of sleep from baseline to 12 mo.CONCLUSION The use of HCL in real-world clinical practice for one year was associated with significant improvements in A1C,%TIR,physical functioning,hypoglycemia fear,emotional distress,and emotional burden related to diabetes management.However,these changes were not associated with time in auto mode.
基金The National High Technology Research and Development Program of China (863Program)(No.2002AA812038)the National Defense Pre-Research Support Program (No.41308050109)
文摘A novel closed-loop control strategy of a silicon microgyroscope (SMG) is proposed. The SMG is sealed in metal can package in drive and sense modes and works under the air pressure of 10 Pa. Its quality factor reaches greater than l0 000. Self-oscillating and closed-loop methods based on electrostatic force feedback are adopted in both measure and control circuits. Both single side driving and sensing methods are used to simplify the drive circuit. These dual channel decomposition and reconstruction closed loops are applied in sense modes. The testing results demonstrate that useful signals and guadrature signals do not interact with each other because of the decoupling of their phases. Under the condition of a scale factor of 9. 6 mV/((°) .s), in a full measurement range of±300 (°)/s, the zero bias stability reaches 28 (°)/h with a nonlinear coefficient of 400 × 10^-6 and a simulated bandwidth of more than 100 Hz. The overall performance is improved by two orders of magnitude in comparison to that at atmospheric pressure.
基金supported by the National Natural Science Foundation of China(11272027)
文摘A dynamics-based adaptive control approach is proposed for a planar dual-arm space robot in the presence of closed-loop constraints and uncertain inertial parameters of the payload. The controller is capable of controlling the po- sition and attitude of both the satellite base and the payload grasped by the manipulator end effectors. The equations of motion in reduced-order form for the constrained system are derived by incorporating the constraint equations in terms of accelerations into Kane's equations of the unconstrained system. Model analysis shows that the resulting equations perfectly meet the requirement of adaptive controller design. Consequently, by using an indirect approach, an adaptive control scheme is proposed to accomplish position/attitude trajectory tracking control with the uncertain parameters be- ing estimated on-line. The actuator redundancy due to the closed-loop constraints is utilized to minimize a weighted norm of the joint torques. Global asymptotic stability is proven by using Lyapunov's method, and simulation results are also presented to demonstrate the effectiveness of the proposed approach.
基金Project(2011ZK2030)supported by the Soft Science Research Plan of Hunan Province,ChinaProject(2010ZDB42)supported by the Social Science Foundation of Hunan Province,China+1 种基金Projects(09A048,11B070)supported by the Science Research Foundation of Education Bureau of Hunan Province,ChinaProjects(2010GK3036,2011FJ6049)supported by the Science and Technology Plan of Hunan Province,China
文摘As the huge computation and easily trapped local optimum in remanufacturing closed-loop supply chain network (RCSCN) design considered, a genetic particle swarm optimization algorithm was proposed. The total cost of closed-loop supply chain was selected as fitness function, and a unique and tidy coding mode was adopted in the proposed algorithm. Then, some mutation and crossover operators were introduced to achieve discrete optimization of RCSCN structure. The simulation results show that the proposed algorithm can gain global optimal solution with good convergent performance and rapidity. The computing speed is only 22.16 s, which is shorter than those of the other optimization algorithms.
基金supported by the Talented Program of Guizhou University(702759203301)the Natural Science Foundation of Guizhou Science and Technology Department(QKHJC-ZK[2021]-YB257)。
文摘Efficient recycling technology for the rapid growth of spent lithium-ion batteries(LIBs)is essential to tackle the resources and environmental crisis.Hydrometallurgical approach has attracted extensive research due to its potential to reduce the consumption of energy and threat to the environment.However,the simultaneous realization of green,efficient and closed-loop recycling is still challenging.Herein,we report a closed-loop and highly efficient approach to recycle lithium cobalt oxide from spent LIBs based on a choline chloride:oxalic acid(ChCl:OA)type deep eutectic solvent(DES).An ultrafast leaching process is observed at 180°C for 10 s with no observable residues.The energy barrier during leaching is calculated to be 113.9 kJ/mol.Noteworthy,the solubility of cobalt ions can be reversibly tuned by simply adding/evaporating deionized water,thus avoiding the addition of precipitant and enabling the easy recovery of the leaching solvent for realizing a closed-loop recycling process.The simultaneous realization of high efficiency,green and closed-loop process is expected to push the DES into practical application for recycling the electrodes of LIBs.
基金supported by the National Natural Science Foundation of China(Nos.91743110,61674114,and 21861132001)the National Key R&D Program of China(Nos.2017YFF0204604 and 2018YFE0118700)+1 种基金Tianjin Applied Basic Research and Advanced Technology(No.17JCJQJC43600),the“111”Project(No.B07014)the Foundation for Talent Scientists of Nanchang Institute for Micro-technology of Tianjin University.
文摘Ambient suspended particulate matter(PM)(primarily with particle diameter 2.5m or less,i.e.,PM2.5)can adversely affect ecosystems and human health.Currently,optical particle sensors based on light scattering dominate the portable PM sensing market.However,the light scattering method has poor adaptability to different-sized PM and adverse environmental conditions.Here,we design and develop a portable PM sensing microsystem that consists of a micromachined virtual impactor(VI)for particle separation,a thermophoretic deposition chip for particle collection,and an extended-gate field-effect transistor(FET)for particle analysis.This system can realize on-site separation,collection,and analysis of aerosol particles without being influenced by environmental factors.In this study,the design of the VI is thoroughly analyzed by numerical simulation,and mixtures of different-sized silicon dioxide(SiO2)particles are used in an experimental verification of the performance of the VI and FET.Considering the low cost and compact design of the whole system,the proposed PM analysis microsystem has potential for PM detection under a wide range of conditions,such as heavily polluted industrial environments and for point-of-need outdoor and indoor air quality monitoring.
基金the financial support from the National Natural Science Foundation of China(Grant Nos.51702095,51722503,51975204)Natural Science Foundation of Hunan Province,China(Grant No.2018JJ3041)+1 种基金the Fundamental Research Funds for the Central Universities(531118010016)Science and Technology Bureau Foundation of Changsha City(kh1904005)。
文摘The rapid progress of micro/nanoelectronic systems and miniaturized portable devices has tremendously increased the urgent demands for miniaturized and integrated power supplies.Miniaturized energy storage devices(MESDs),with their excellent properties and additional intelligent functions,are considered to be the preferable energy supplies for uninterrupted powering of microsystems.In this review,we aim to provide a comprehensive overview of the background,fundamentals,device configurations,manufacturing processes,and typical applications of MESDs,including their recent advances.Particular attention is paid to advanced device configurations,such as two-dimensional(2D)stacked,2D planar interdigital,2D arbitrary-shaped,three-dimensional planar,and wire-shaped structures,and their corresponding manufacturing strategies,such as printing,scribing,and masking techniques.Additionally,recent developments in MESDs,including microbatteries and microsupercapacitors,as well as microhybrid metal ion capacitors,are systematically summarized.A series of on-chip microsystems,created by integrating functional MESDs,are also highlighted.Finally,the remaining challenges and future research scope on MESDs are discussed.
基金supported by grant from National Nature Science Found (30670767)
文摘Objective: To evaluate the efficiency of an implanted chip system for the control of heart rate (HR). Methods: The HR was recorded in six conscious Sprague-Dawley (SD) rats. An implanted chip system was designed to regulate the HR by stimulating the right cervical vagus nerve according to the feedback of real time HR. Each rat was subjected to 30-min regulation and 30-min recovery. The change of HR during the regulation period was compared with the control. The ECG was recorded during the experiment for 24 h. Results: The ECG signals were successfully recorded during the experiment. The HR was significantly decreased during the period of regulation compared with control (-79.3 ± 34.5, P 〈 0.01, n = 6) and then recovered to normal after regulation. Conclusion: The described implanted chip system can regulate the HR to a designated set point.