A novel carbon trap sampling system for gas-phase mercury measurement in flue gas is developed, including the high efficient sorbents made of modified biomass cokes and high precision sorbent traps for measuring parti...A novel carbon trap sampling system for gas-phase mercury measurement in flue gas is developed, including the high efficient sorbents made of modified biomass cokes and high precision sorbent traps for measuring particle-bound and total vapor-phase mercury in flue gas. A dedusting device is installed to collect fine fly ash for reducing the measurement errors. The thorough comparison test of mercury concentration in flue gas is conducted between the novel sampling system and the Ontario hydro method (OHM) in a 6 kW circulating fluidized bed combustor. Mercury mass balance rates of the OHM range from 95.47% to 104.72%. The mercury breakthrough rates for the second section of the sorbent trap are all below 2%. The relative deviations in the two test cases are in the range of 15. 96% to 17. 56% under different conditions. The verified data suggest that this novel carbon trap sampling system can meet the standards of quality assurance and quality control required by EPA Method 30B and can be applied to the coal-fired flue gas mercury sampling system.展开更多
Northern China has rich wind power and photovoltaic renewable resources. Combined Heat and Power (CHP) Units to meet the load demand and limit its peaking capacity in winter, to a certain extent, it results in structu...Northern China has rich wind power and photovoltaic renewable resources. Combined Heat and Power (CHP) Units to meet the load demand and limit its peaking capacity in winter, to a certain extent, it results in structural problems of wind-solar power and thermoelectric. To solve these problems, this paper proposes a plurality of units together to ensure supply of heat load on the premise, by building a thermoelectric power peaking considering thermal load unit group dynamic scheduling model, to achieve the potential of different thermoelectric properties peaking units of the excavation. Simulation examples show, if the unit group exists obvious relationship thermoelectric individual differences, the thermal load dynamic scheduling can be more significantly improved overall performance peaking unit group, effectively increase clean energy consumptive.展开更多
With the increase in the power receiving proportion and an insufficient peak regulation capacity of the local units, the receiving-end power grid struggles to achieve peak regulation in valley time. To solve this prob...With the increase in the power receiving proportion and an insufficient peak regulation capacity of the local units, the receiving-end power grid struggles to achieve peak regulation in valley time. To solve this problem while considering the potential of the large-scale charge load of electric vehicles(EVs), an aggregator-based demand response(DR) mechanism for EVs that are participating in the peak regulation in valley time is proposed in this study. In this aggregator-based DR mechanism, the profits for the power grid’s operation and the participation willingness of the EV owners are considered. Based on the characteristics of the EV charging process and the day-ahead unit generation scheduling, a rolling unit commitment model with the DR is established to maximize the social welfare. In addition, to improve the efficiency of the optimization problem solving process and to achieve communication between the independent system operator(ISO) and the aggregators, the clustering algorithm is utilized to extract typical EV charging patterns. Finally, the feasibility and benefits of the aggregator-based DR mechanism for saving the costs and reducing the peak-valley difference of the receiving-end power grid are verified through case studies.展开更多
Due to the shortage of fossil energy and the pollution caused by combustion of fossil fuels,the proportion of renewable energy in power systems is gradually increasing across the world.Accordingly,the capacity of powe...Due to the shortage of fossil energy and the pollution caused by combustion of fossil fuels,the proportion of renewable energy in power systems is gradually increasing across the world.Accordingly,the capacity of power systems to accommodate renewable energy must be improved.However,integration of a large amount of renewable energy into power grids may result in network congestion.Hence,in this study,optimal transmission switching(OTS)is considered as an important method of accommodating renewable energy.It is incorporated into the operation of a power grid along with deep peak regulation of thermal power units,forming an interactive mode of coordinated operation of source and network.A stochastic unit commitment model consider!ng deep peak regulation and OTS is established,and the role of OTS in promoting the accommodation of renewable energy is analyzed quantitatively.The results of case studies involving the IEEE 30-bus system demonstrate that OTS can enable utilization of the potential of deep peak regulation and facilitate the accommodation of renewable energy.展开更多
We proposed unit flood discharge model that defined as the discharge into end-order (smallest) drainage canals. The discharge acts an important role for estimating regional flooding by big rainfall events which leadin...We proposed unit flood discharge model that defined as the discharge into end-order (smallest) drainage canals. The discharge acts an important role for estimating regional flooding by big rainfall events which leading roughly estimation of flood discharge associated with land use changes as urbanization. In some areas of Japan, increased urbanization with insufficient drainage canal capacity has led to increasingly frequent flooding and flood damage. The aim of this study was to investigate the effect of urbanization on unit flood discharge using a runoff model for the Tedori River alluvial fan area, Japan. The discharge was studied as collecting runoff from paddy fields, upland crop fields, and residential lots. A runoff model for various land use types in the study area was developed using actual and physical properties of the runoff sites, and parameters for paddy fields. The model was tested using 54 big events and inputted those. The maximum total runoff ratio among different land use types was observed for residential lots, and the ratio remained relatively constant across different flood events. The minimum total runoff ratio was observed for irrigated paddy fields. There was a positive relationship between the total runoff ratio and total precipitation for all land use types. Whereas, the relationship between the peak runoff ratio and peak precipitation was variable. The runoff analysis was carried out using 60-min and 10-min precipitation data. For agricultural land, data for both intervals produced similar results.展开更多
Unit hydrograph is a very practical tool in runoff prediction which has been used since decades ago and to date it remains useful. Unit hydrograph method is applied in Way Kuala Garuntang, an ungauged catchment in Lam...Unit hydrograph is a very practical tool in runoff prediction which has been used since decades ago and to date it remains useful. Unit hydrograph method is applied in Way Kuala Garuntang, an ungauged catchment in Lampung Province, Indonesia. To derive an observed unit hydrograph it requires rainfall and water level data with fine time scale which are obtained from automatic gauges. Observed unit hydrograph has an advantage that it is possible to derive it for various time steps including those with time step less than an hour. In order to get a more accurate unit hydrograph, it is necessary to derive a unit hydrograph with small time step for a small catchment such as those used in this study. The study area includes Way Kuala Garuntang and its tributaries, i.e. Way Simpur, Way Awi with areas are 60.52 km2, 3.691 km2, and 9.846 km2 respectively. The results of this study highlight the importance of time step selection on unit hydrograph, which are shown to have a significant impact on the resulting unit hydrograph’s variables such as peak discharge and time to peak.展开更多
Recently severe damage of flooding by urbanization was frequently occurred. To prevent this damage, small reservoir was constructed in the urbanized residential area. This paper describes an effect of flood peak disch...Recently severe damage of flooding by urbanization was frequently occurred. To prevent this damage, small reservoir was constructed in the urbanized residential area. This paper describes an effect of flood peak discharge control by a small reservoir (control reservoir) caused by rapidly developed urbanization. Although work for this purpose was conducted, research on the effects of the control reservoir was not conducted until now. This research, conducted by simulation, was a case study in the Kurabe River Basin in the Tedori River Alluvial Fan Area, Japan, based on the precise investigation of the reservoir in the actual field. The study was conducted to determine not only the actual control reservoir capacity for the newly developed residential area but also the ideal capacity for all present residential areas and the largest capacity allowable for a maximum rainfall event that recently occurred. The control reservoir effects between individual blocks and the entire basin area were compared by dividing the test basin into 15 blocks (sub-basins). The results showed that the effects on the capacity per unit area of the residential area in blocks have close relationship with the decreasing ratio of peak discharge in blocks. Consequently, the effects of control reservoir capacity and the limitation were clarified. In the future, control reservoirs should be constructed for all of the already developed residential areas, for example, by utilizing underground car parking lot. The results of this research can contribute to the design of the control reservoir for protection against flooding damage in urbanized areas.展开更多
There exists a certain amount of SO_3 in flue gas discharged from coal-fired power plants. With the operation of the selective catalystic reduction( SCR) denitrification system,SO_3 concentration in the flue gas incre...There exists a certain amount of SO_3 in flue gas discharged from coal-fired power plants. With the operation of the selective catalystic reduction( SCR) denitrification system,SO_3 concentration in the flue gas increases,which will lead to fouling,erosion and plugging of downstream equipment. In this study,the main effects of SO_3 on the safety,stability and efficiency of units were analyzed,and measures to control SO_3 were proposed.展开更多
针对分布式电源和新型负荷容量累积造成负荷影响因素多元化和不确定性特性增强的问题,文中提出一种采用记忆神经网络和曲线形状修正的负荷预测方法。在负荷峰值预测中,采用最大信息系数计算负荷峰值与影响因素的非线性相关性,实现对输...针对分布式电源和新型负荷容量累积造成负荷影响因素多元化和不确定性特性增强的问题,文中提出一种采用记忆神经网络和曲线形状修正的负荷预测方法。在负荷峰值预测中,采用最大信息系数计算负荷峰值与影响因素的非线性相关性,实现对输入特征的筛选;综合考虑负荷峰值序列的长短期自相关性和输入特征与负荷峰值的不同程度相关性,结合Attention机制和双向长短时记忆(bidirectional long short-term memory,BiLSTM)神经网络建立负荷峰值预测模型。在负荷标幺曲线预测中,通过误差倒数法组合相似日和相邻日,建立负荷标幺曲线预测模型;针对预测偏差的非平稳特征,利用自适应噪声的完全集成经验模态分解和BiLSTM网络建立误差预测模型,对曲线形状进行修正。应用中国北方某城市的区域电网负荷数据为算例,验证了所提模型的有效性。展开更多
基金The National Natural Science Foundation of China(No.51376046,51076030)the National Science and Technology Support Program of China(No.2012BAA02B01)+1 种基金the Fundamental Research Funds for the Central Universitiesthe Scientific Innovation Research of College Graduates in Jiangsu Province(No.CXZZ13_0093,KYLX_0115,KYLX_018)
文摘A novel carbon trap sampling system for gas-phase mercury measurement in flue gas is developed, including the high efficient sorbents made of modified biomass cokes and high precision sorbent traps for measuring particle-bound and total vapor-phase mercury in flue gas. A dedusting device is installed to collect fine fly ash for reducing the measurement errors. The thorough comparison test of mercury concentration in flue gas is conducted between the novel sampling system and the Ontario hydro method (OHM) in a 6 kW circulating fluidized bed combustor. Mercury mass balance rates of the OHM range from 95.47% to 104.72%. The mercury breakthrough rates for the second section of the sorbent trap are all below 2%. The relative deviations in the two test cases are in the range of 15. 96% to 17. 56% under different conditions. The verified data suggest that this novel carbon trap sampling system can meet the standards of quality assurance and quality control required by EPA Method 30B and can be applied to the coal-fired flue gas mercury sampling system.
文摘Northern China has rich wind power and photovoltaic renewable resources. Combined Heat and Power (CHP) Units to meet the load demand and limit its peaking capacity in winter, to a certain extent, it results in structural problems of wind-solar power and thermoelectric. To solve these problems, this paper proposes a plurality of units together to ensure supply of heat load on the premise, by building a thermoelectric power peaking considering thermal load unit group dynamic scheduling model, to achieve the potential of different thermoelectric properties peaking units of the excavation. Simulation examples show, if the unit group exists obvious relationship thermoelectric individual differences, the thermal load dynamic scheduling can be more significantly improved overall performance peaking unit group, effectively increase clean energy consumptive.
基金supported by the Science and Technology Project from the State Grid Shanghai Municipal Electric Power Company of China (52094019006U)the Shanghai Rising-Star Program (18QB1400200)。
文摘With the increase in the power receiving proportion and an insufficient peak regulation capacity of the local units, the receiving-end power grid struggles to achieve peak regulation in valley time. To solve this problem while considering the potential of the large-scale charge load of electric vehicles(EVs), an aggregator-based demand response(DR) mechanism for EVs that are participating in the peak regulation in valley time is proposed in this study. In this aggregator-based DR mechanism, the profits for the power grid’s operation and the participation willingness of the EV owners are considered. Based on the characteristics of the EV charging process and the day-ahead unit generation scheduling, a rolling unit commitment model with the DR is established to maximize the social welfare. In addition, to improve the efficiency of the optimization problem solving process and to achieve communication between the independent system operator(ISO) and the aggregators, the clustering algorithm is utilized to extract typical EV charging patterns. Finally, the feasibility and benefits of the aggregator-based DR mechanism for saving the costs and reducing the peak-valley difference of the receiving-end power grid are verified through case studies.
基金the National Natural Science Foundation of China(No.U1966204)the China State Key Lab.of Power System(SKJLD19KM09).
文摘Due to the shortage of fossil energy and the pollution caused by combustion of fossil fuels,the proportion of renewable energy in power systems is gradually increasing across the world.Accordingly,the capacity of power systems to accommodate renewable energy must be improved.However,integration of a large amount of renewable energy into power grids may result in network congestion.Hence,in this study,optimal transmission switching(OTS)is considered as an important method of accommodating renewable energy.It is incorporated into the operation of a power grid along with deep peak regulation of thermal power units,forming an interactive mode of coordinated operation of source and network.A stochastic unit commitment model consider!ng deep peak regulation and OTS is established,and the role of OTS in promoting the accommodation of renewable energy is analyzed quantitatively.The results of case studies involving the IEEE 30-bus system demonstrate that OTS can enable utilization of the potential of deep peak regulation and facilitate the accommodation of renewable energy.
文摘We proposed unit flood discharge model that defined as the discharge into end-order (smallest) drainage canals. The discharge acts an important role for estimating regional flooding by big rainfall events which leading roughly estimation of flood discharge associated with land use changes as urbanization. In some areas of Japan, increased urbanization with insufficient drainage canal capacity has led to increasingly frequent flooding and flood damage. The aim of this study was to investigate the effect of urbanization on unit flood discharge using a runoff model for the Tedori River alluvial fan area, Japan. The discharge was studied as collecting runoff from paddy fields, upland crop fields, and residential lots. A runoff model for various land use types in the study area was developed using actual and physical properties of the runoff sites, and parameters for paddy fields. The model was tested using 54 big events and inputted those. The maximum total runoff ratio among different land use types was observed for residential lots, and the ratio remained relatively constant across different flood events. The minimum total runoff ratio was observed for irrigated paddy fields. There was a positive relationship between the total runoff ratio and total precipitation for all land use types. Whereas, the relationship between the peak runoff ratio and peak precipitation was variable. The runoff analysis was carried out using 60-min and 10-min precipitation data. For agricultural land, data for both intervals produced similar results.
文摘Unit hydrograph is a very practical tool in runoff prediction which has been used since decades ago and to date it remains useful. Unit hydrograph method is applied in Way Kuala Garuntang, an ungauged catchment in Lampung Province, Indonesia. To derive an observed unit hydrograph it requires rainfall and water level data with fine time scale which are obtained from automatic gauges. Observed unit hydrograph has an advantage that it is possible to derive it for various time steps including those with time step less than an hour. In order to get a more accurate unit hydrograph, it is necessary to derive a unit hydrograph with small time step for a small catchment such as those used in this study. The study area includes Way Kuala Garuntang and its tributaries, i.e. Way Simpur, Way Awi with areas are 60.52 km2, 3.691 km2, and 9.846 km2 respectively. The results of this study highlight the importance of time step selection on unit hydrograph, which are shown to have a significant impact on the resulting unit hydrograph’s variables such as peak discharge and time to peak.
文摘Recently severe damage of flooding by urbanization was frequently occurred. To prevent this damage, small reservoir was constructed in the urbanized residential area. This paper describes an effect of flood peak discharge control by a small reservoir (control reservoir) caused by rapidly developed urbanization. Although work for this purpose was conducted, research on the effects of the control reservoir was not conducted until now. This research, conducted by simulation, was a case study in the Kurabe River Basin in the Tedori River Alluvial Fan Area, Japan, based on the precise investigation of the reservoir in the actual field. The study was conducted to determine not only the actual control reservoir capacity for the newly developed residential area but also the ideal capacity for all present residential areas and the largest capacity allowable for a maximum rainfall event that recently occurred. The control reservoir effects between individual blocks and the entire basin area were compared by dividing the test basin into 15 blocks (sub-basins). The results showed that the effects on the capacity per unit area of the residential area in blocks have close relationship with the decreasing ratio of peak discharge in blocks. Consequently, the effects of control reservoir capacity and the limitation were clarified. In the future, control reservoirs should be constructed for all of the already developed residential areas, for example, by utilizing underground car parking lot. The results of this research can contribute to the design of the control reservoir for protection against flooding damage in urbanized areas.
基金Supported by National High Technology Research and Development Program of China(863 Program)(2013AA065401)
文摘There exists a certain amount of SO_3 in flue gas discharged from coal-fired power plants. With the operation of the selective catalystic reduction( SCR) denitrification system,SO_3 concentration in the flue gas increases,which will lead to fouling,erosion and plugging of downstream equipment. In this study,the main effects of SO_3 on the safety,stability and efficiency of units were analyzed,and measures to control SO_3 were proposed.
文摘针对分布式电源和新型负荷容量累积造成负荷影响因素多元化和不确定性特性增强的问题,文中提出一种采用记忆神经网络和曲线形状修正的负荷预测方法。在负荷峰值预测中,采用最大信息系数计算负荷峰值与影响因素的非线性相关性,实现对输入特征的筛选;综合考虑负荷峰值序列的长短期自相关性和输入特征与负荷峰值的不同程度相关性,结合Attention机制和双向长短时记忆(bidirectional long short-term memory,BiLSTM)神经网络建立负荷峰值预测模型。在负荷标幺曲线预测中,通过误差倒数法组合相似日和相邻日,建立负荷标幺曲线预测模型;针对预测偏差的非平稳特征,利用自适应噪声的完全集成经验模态分解和BiLSTM网络建立误差预测模型,对曲线形状进行修正。应用中国北方某城市的区域电网负荷数据为算例,验证了所提模型的有效性。