期刊文献+
共找到195篇文章
< 1 2 10 >
每页显示 20 50 100
Problems of Hazardous Waste Storage Facilities in Coal-fired Power Plants and Countermeasures
1
作者 Wenqi YUE 《Meteorological and Environmental Research》 CAS 2023年第2期57-60,65,共5页
The hazardous waste produced by coal-fired power plants are large in quantity and variety. It is important for ecological environment protection to properly store hazardous waste in coal-fired power plants. The enviro... The hazardous waste produced by coal-fired power plants are large in quantity and variety. It is important for ecological environment protection to properly store hazardous waste in coal-fired power plants. The environmental management of hazardous waste in coal-fired power plants started late, and there are many problems in the construction and management of their storage facilities. In this paper, taking eight typical coal-fired power plants as examples, the present problems of hazardous waste storage facilities in coal-fired power plants are analyzed, and corresponding countermeasures are put forward to solve the main common problems. 展开更多
关键词 coal-fired power plants Hazardous waste storage Types of problems COUNTERMEASURES
下载PDF
Progress and prospects of innovative coal-fired power plants within the energy internet 被引量:7
2
作者 Yongping Yang Chengzhou Li +1 位作者 Ningling Wang Zhiping Yang 《Global Energy Interconnection》 2019年第2期160-179,共20页
The development of electrical engineering and electronic, communications, smart power grid, and ultra-high voltage transmission technologies have driven the energy system revolution to the next generation: the energy ... The development of electrical engineering and electronic, communications, smart power grid, and ultra-high voltage transmission technologies have driven the energy system revolution to the next generation: the energy internet. Progressive penetration of intermittent renewable energy sources into the energy system has led to unprecedented challenges to the currently wide use of coal-fired power generation technologies. Here, the applications and prospects of advanced coal-fired power generation technologies are analyzed. These technologies can be summarized into three categories:(1) large-scale and higher parameters coal-fired power generation technologies, including 620/650/700 oC ultra-supercritical thermal power and double reheat ultra-supercritical coal-fired power generation technologies;(2) system innovation and specific, highefficiency thermal cycles, which consist of renewable energy-aided coal-fired power generation technologies, a supercritical CO_2 Brayton cycle for coal-fired power plants, large-scale air-cooling coal-fired power plant technologies, and innovative layouts for waste heat utilization and enhanced energy cascade utilization;(3) coal-fired power generation combined with poly-generation technologies, which are represented by integrated gasification combined cycle(IGCC) and integrated gasification fuel cell(IGFC) technologies. Concerning the existing coal-fired power units, which are responsible for peak shaving, possible strategies for enhancing flexibility and operational stability are discussed. Furthermore, future trends for coal-fired power plants coupled with cyber-physical system(CPS) technologies are introduced. The development of advanced, coal-fired power generation technologies demonstrates the progress of science and is suitable for the sustainable development of human society. 展开更多
关键词 En ergy In ternet coal-fired power GEN eration FLEXIBILITY Cyber-physical system Smart power plant
下载PDF
Formation and emission characteristics of VOCs from a coal-fired power plant 被引量:3
3
作者 Jingying Xu Yue Lyu +3 位作者 Jiankun Zhuo Yishu Xu Zijian Zhou Qiang Yao 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第7期256-264,共9页
On-site measurements of volatile organic compounds(VOCs)in different streams of flue gas were carried out on a real coal-fired power plant using sampling bags and SUMMA canisters to collect gas samples,filters to coll... On-site measurements of volatile organic compounds(VOCs)in different streams of flue gas were carried out on a real coal-fired power plant using sampling bags and SUMMA canisters to collect gas samples,filters to collect particle samples.Gas chromatography-flame ionization detector/mass spectrometry and gas chromatography-mass spectrometry was the offline analysis method.We found that the total mass concentration of the tested 102 VOC species at the outlet of wet flue gas desulfuration device was(13456±47)μg·m^(-3),which contained aliphatic hydrocarbons(57.9%),aromatic hydrocarbons(26.8%),halogen-containing species(14.5%),and a small amount of oxygen-containing and nitrogencontaining species.The most abundant species were 1-hexene,n-hexane and 2-methylpentane.The top ten species in terms of mass fraction(with a total mass fraction of 75.3%)were mainly hydrocarbons with a carbon number of 6 or higher and halogenated hydrocarbons with a lower carbon number.The mass concentration of VOC species in the particle phase was significantly lower than that in the gas phase.The change of VOC mass concentrations along the air pollution control devices indicates that conventional pollutant control equipment had a limited effect on VOC reduction.Ozone formation potential calculations showed that aromatic hydrocarbons contributed the highest ozone formation(46.4%)due to their relatively high mass concentrations and MIR(maximum increment reactivity)values. 展开更多
关键词 Volatile organic compounds Coal combustion Ozone formation potential coal-fired power plant On-site measurement
下载PDF
Optimization of an Existing Coal-fired Power Plant with CO<sup>2</sup>Capture 被引量:2
4
作者 Ying Wu Wenyi Liu Yong-ping Yang 《Energy and Power Engineering》 2013年第4期157-161,共5页
Nowadays, the worsening environmental issue caused by CO2 emission is greatly aggravated by human activity. Many CO2 reduction technologies are under fast development. Among these, monoethanolamine (MEA) based CO2 cap... Nowadays, the worsening environmental issue caused by CO2 emission is greatly aggravated by human activity. Many CO2 reduction technologies are under fast development. Among these, monoethanolamine (MEA) based CO2 capture technology has been paid great attention. However, when connecting the CO2 capture process with a coal-fired power plant, the huge energy and efficiency penalty caused by CO2 capture has become a serious problem for its application. Thus, it is of great significance to reduce the related energy consumption. Based on an existing coal-fired power plant, this paper proposes a new way for the decarburized retrofitting of the coal-fired power plant, which helps to improve the overall efficiency of the power plant with less energy and efficiency penalty. The decarburized retrofitting scheme proposed will provide a new route for the CO2 capture process in China. 展开更多
关键词 MEA CO2 CAPTURE Decarburized Retrofitting coal-fired power plant
下载PDF
Status and Prospect of Coal-fired Power Plant Automation in China 被引量:1
5
《Electricity》 1999年第1期28-31,共4页
关键词 MEH Status and Prospect of coal-fired power plant Automation in China
下载PDF
Field Studies on the Removal Characteristics of Particulate Matter and SO_(x) in Ultra-Low Emission Coal-Fired Power Plant
6
作者 Xu Zhao Houzhang Tan +1 位作者 Fuxin Yang Shuanghui Deng 《Energy Engineering》 EI 2022年第1期49-62,共14页
In order to reduce the environmental smog caused by coal combustion,air pollution control devices have been widely used in coal-fired power plants,especially of wet flue gas desulfurization(WFGD)and wet electrostatic ... In order to reduce the environmental smog caused by coal combustion,air pollution control devices have been widely used in coal-fired power plants,especially of wet flue gas desulfurization(WFGD)and wet electrostatic precipitator(WESP).In this work,particulate matter with aerodynamic diameter less than 10μm(PM_(10))and sulfur oxides(SO_(x))have been studied in a coal-fired power plant.The plant is equipped with selective catalytic reduction,electrostatic precipitator,WFGD,WESP.The results show that the PM_(10)removal efficiencies in WFGD and WESP are 54.34%and 50.39%,respectively,and the overall removal efficiency is 77.35%.WFGD and WESP have effects on the particle size distribution.After WFGD,the peak of particles shifts from 1.62 to 0.95μm,and the mass concentration of fine particles with aerodynamic diameter less than 0.61μm increases.After WESP,the peak of particle size shifts from 0.95 to 1.61μm.The differences are due to the agglomeration and growth of small particles.The SO_(3)mass concentration increases after SCR,but WFGD has a great influence on SO_(x)with the efficiency of 96.56%.WESP can remove SO_(x),but the efficiency is 20.91%.The final emission factors of SO_(2),SO_(3),PM_(1),PM_(2.5)and PM_(10)are 0.1597,0.0450,0.0154,0.0267 and 0.0215(kg·t^(−1)),respectively.Compared with the research results without ultra-low emission retrofit,the emission factors are reduced by 1~2 orders of magnitude,and the emission control level of air pollutants is greatly improved. 展开更多
关键词 Particulate matter sulfur oxides wet flue gas desulfurization wet electrostatic precipitator coal-fired power plant
下载PDF
Development of Carbon Dioxide Capture Technologies in Coal-Fired Power Plants
7
作者 Gao Shiwang, Xu Shisen, Liu Lianbo, Niu Hongwei and Cai Ming Xi’an Thermal Power Research Institute Co., Ltd. Liu Lianbo 《Electricity》 2010年第4期50-54,共5页
With a particular reference to China Huaneng Group's practices in CO_2 capture, this article presents a brief ing on the current development of CO_2 capture technologies in coal-fired power plants both in China an... With a particular reference to China Huaneng Group's practices in CO_2 capture, this article presents a brief ing on the current development of CO_2 capture technologies in coal-fired power plants both in China and abroad. Sooner or later, the integration of CO_2 capture and storage (CCS) facility with coal-fired power plant will be inevitably put on the agenda of developers. 展开更多
关键词 coal-fired power plant EMISSION control CARBON dioxide CAPTURE
下载PDF
Xiangfan Coal-fired Power Plant - a matched large power plant for Three Gorges Project starts to construct
8
《Electricity》 1996年第4期44-44,共1页
Xiangfan Coal-fired Power Plant, a key energy construction project matched with Three Gorges Project, approved by the State Council. formally started to build in the suburb of Xiangfan City, Hubei Province on November... Xiangfan Coal-fired Power Plant, a key energy construction project matched with Three Gorges Project, approved by the State Council. formally started to build in the suburb of Xiangfan City, Hubei Province on November 29, 1996. 展开更多
关键词 PROJECT Xiangfan coal-fired power plant a matched large power plant for Three Gorges Project starts to construct
下载PDF
Necessity and Measures of Water Conservation for Coal-fired Power Plants in China
9
《Electricity》 1999年第1期31-35,共5页
关键词 Necessity and Measures of Water Conservation for coal-fired power plants in China
下载PDF
Regulations and Practice on Flue Gas Denitrification for Coal-Fired Power Plants in China
10
作者 Zhu Fahua1 and Zhao Guohua2 1. State Power Environmental Protection Research Institute 2. Nanjing University of Information Science & Technology 《Electricity》 2008年第1期49-52,共4页
In China, according to the relative up-to-date regulations and standards, the maincontrol measure for NOX emission of coal-fired power plants is, in principle, low NOXcombustion. However, in recent years, more and mor... In China, according to the relative up-to-date regulations and standards, the maincontrol measure for NOX emission of coal-fired power plants is, in principle, low NOXcombustion. However, in recent years, more and more newlyapproved coal-fired plantswere required to install flue gas denitrification equipment. This article expounds if fluegas denitrification is necessary from several aspects, including constitution of NOX, itsimpact to environment, operation ofdeNOXequipment in USA, as wellas the differencein ambient air quality standard between China and World Health Organization. It setsforth themes in urgent need of study and areas where deNOX equipment is necessaryfor new projects, besides a recommendation that the emission standards for thermalpowerplants should be revised as soon as possible in China. 展开更多
关键词 Regulations and Practice on Flue Gas Denitrification for coal-fired power plants in China
下载PDF
Probabilistic Approach of Coastal Defense Against Typhoon Attacks for Nuclear Power Plant 被引量:1
11
作者 刘德辅 韩凤亭 +3 位作者 庞亮 李华军 谢波涛 王风清 《China Ocean Engineering》 SCIE EI 2010年第2期265-275,共11页
With the global warming and sea level rising, it is widely recognized that there is an increasing tendency of typhoon occurrence frequency and intensity. The defenses code against typhoon attacks for nuclear power pla... With the global warming and sea level rising, it is widely recognized that there is an increasing tendency of typhoon occurrence frequency and intensity. The defenses code against typhoon attacks for nuclear power plant should be calibrated because of the increasing threat of typhoon disaster and severe consequences. This paper discusses the probabilistic approach of definitions about "probable maximum typhoon" and "probable maximum storm surge" in nuclear safety regulations of China and has made some design code calibrations by use of a newly proposed Double Layer Nested Mtdti-objective Probability Model (DLNMPM). 展开更多
关键词 TYPHOON nuclear power plant coastal engineering code calibration double layer nested multi-objective probability model
下载PDF
Effects of coal-fired power plants on soil microbial diversity and community structures
12
作者 Bowen Sun Renbin Zhu +6 位作者 Yu Shi Wanying Zhang Zeming Zhou Dawei Ma Runfang Wang Haitao Dai Chenshuai Che 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2024年第3期206-223,共18页
Long-term deposition of atmospheric pollutants emitted from coal combustion and their effects on the eco-environment have been extensively studied around coal-fired power plants.However,the effects of coal-fired power... Long-term deposition of atmospheric pollutants emitted from coal combustion and their effects on the eco-environment have been extensively studied around coal-fired power plants.However,the effects of coal-fired power plants on soil microbial communities have received little attention through atmospheric pollutant deposition and coal-stacking.Here,we collected the samples of power plant soils(PS),coal-stacking soils(CSS)and agricultural soils(AS)around three coal-fired power plants and background control soils(BG)in Huainan,a typical mineral resource-based city in East China,and investigated the microbial diversity and community structures through a high-throughput sequencing technique.Coal-stacking significantly increased(p<0.05)the contents of total carbon,total nitrogen,total sulfur and Mo in the soils,whereas the deposition of atmospheric pollutants enhanced the levels of V,Cu,Zn and Pb.Proteobacteria,Actinobacteria,Thaumarchaeota,Thermoplasmata,Ascomycota and Basidiomycota were the dominant taxa in all soils.The bacterial community showed significant differences(p<0.05)among PS,CSS,AS and BG,whereas archaeal and fungal communities showed significant differences(p<0.01)according to soil samples around three coal-fired power plants.The predominant environmental variables affecting soil bacterial,archaeal and fungal communities were Mo-TN-TS,Cu-V-Mo,and organic matter(OM)-Mo,respectively.Certain soil microbial genera were closely related to multiple key factors associated with stacking coal and heavy metal deposition from power plants.This study provided useful insight into better understanding of the relationships between soil microbial communities and long-term disturbances from coal-fired power plants. 展开更多
关键词 coal-fired power plants Soil microbial communities Coal-stacking Heavy metals Environmental variables
原文传递
Choice of Site for the Installation of Photovoltaic Solar Power Plants in Senegal: Consequences on Electricity Production 被引量:1
13
作者 Mactar Faye Ababacar Thiam 《Journal of Power and Energy Engineering》 2017年第12期109-118,共10页
A theoretical analysis of the electricity production of a photovoltaic solar power plant of 22 MW for different sites in Senegal is presented. The study is carried out in two coastal regions (Dakar and Saint-Louis) an... A theoretical analysis of the electricity production of a photovoltaic solar power plant of 22 MW for different sites in Senegal is presented. The study is carried out in two coastal regions (Dakar and Saint-Louis) and two continental regions (Mbacké and Linguère). This study is done using the RET Screen clean energy project management software climate data. The amount of electricity exported to the grid is calculated for each site. The results show that the climatic conditions of the coastal and continental regions are different from November to June. From July to October, which corresponds to the rainy season in Senegal, the climatic conditions of the coastal and continental regions are similar. The results also show that although the efficiency of photovoltaic modules is better on the coast, electricity production varies little from one site to another. Climate conditions in Senegal therefore have no impact on electricity production. 展开更多
关键词 PHOTOVOLTAIC Solar power plant CLIMATIC Conditions Electricity Production coastal ZONE CONTINENTAL ZONE
下载PDF
An integrated analysis of air pollution from US coal-fired power plants 被引量:1
14
作者 Mikalai Filonchyk Michael P.Peterson 《Geoscience Frontiers》 SCIE CAS CSCD 2023年第2期204-216,共13页
The United States is one of the world’s leaders in electricity production,generating about 4116 billion kWh in 2021,of which coal accounted for 21.8%of the total.This study applies an integrated approach using both t... The United States is one of the world’s leaders in electricity production,generating about 4116 billion kWh in 2021,of which coal accounted for 21.8%of the total.This study applies an integrated approach using both terrestrial and satellite data to specifically examine emissions from coal-fired power plants and its spatial extent.The study also highlights the effectiveness of government policies to reduce emissions.It was found that emission of pollutants from the country’s energy sector has been steadily declining,with annual emissions of sulfur dioxide(SO_(2))and nitrogen oxides(NOx)decreasing from the US electric power sector between 1990 and 2020 by 93.4%and 84.8%,respectively,and carbon dioxide(CO_(2))by 37%between 2007 and 2020.Although overall emissions from coal-fired power plants are declining,some individual plants have yet to install environmental equipment to control emissions.According to US government data,major emitters of SO_(2),NO_(x),and CO_(2) in the US are the Martin Lake power plant in East Texas,the Labadie power plant near St.Louis,Missouri,and the James H Miller Jr plant near Birmingham,Alabama.This study also integrates TROPOMI satellite data to detect point emissions from individual power plants.While the highest levels of measured pollutants were over the country’s major cities and areas of fossil fuel extraction,TROPOMI could clearly distinguish the pollution caused by power plants in more rural areas.Although the US has made great strides in reducing emissions from coal-fired power plants,these plants still represent a major source of pollution and remain a major concern.Totally eliminating coal as a power source will be difficult with the higher power demands resulting from the transition to electric automobiles. 展开更多
关键词 coal-fired power plants EMISSIONS TROPOMI Air pollution Sulfur dioxide Nitrogen oxides
原文传递
Increasing Coal-Fired Power Plant Operational Flexibility by Integrating Solar Thermal Energy and Compressed Air Energy Storage System 被引量:1
15
作者 LI Xiaoyu WANG Yumeng +4 位作者 ZHANG Xinjing LI Bin XU Yujie CHEN Haisheng SHENG Siqing 《Journal of Thermal Science》 SCIE EI CAS CSCD 2023年第6期2032-2047,共16页
This paper proposed a novel integrated system with solar energy,thermal energy storage(TES),coal-fired power plant(CFPP),and compressed air energy storage(CAES)system to improve the operational flexibility of the CFPP... This paper proposed a novel integrated system with solar energy,thermal energy storage(TES),coal-fired power plant(CFPP),and compressed air energy storage(CAES)system to improve the operational flexibility of the CFPP.A portion of the solar energy is adopted for preheating the boiler’s feedwater,and another portion is stored in the TES for the CAES discharging process.Condensate water from the CFPP condenser is used for cooling compressed air during the CAES charging process.The thermodynamic performance of the integrated system under different load conditions is studied.The system operations in a typical day are simulated with EBSILON software.The system enables daily coal saving of 9.88 t and reduces CO_(2)emission by 27.95 t compared with the original CFPP at 100%load.Under partial load conditions,the system enables maximum coal saving of 10.29 t and maximum CO_(2)emission reduction of 29.11 t at 75%load.The system has maximum peak shaving depth of 9.42%under 40%load condition.The potential of the system participating ancillary service is also discussed.It is found that the integration of solar thermal system and CAES system can bring significant ancillary service revenue to a conventional CFPP. 展开更多
关键词 solar thermal compressed air energy storage coal-fired power plant thermal energy storage operation flexibility ancillary service
原文传递
Zooplankton community size-structure change and mesh size selection under the thermal stress caused by a power plant in a semi-enclosed bay
16
作者 Qianwen Shao Yifeng Zhu +3 位作者 Meixia Dai Xia Lin Chengxu Zhou Xiaojun Yan 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2020年第8期62-70,共9页
Zooplankton samples were collected using 505, 160 and 77 μm mesh nets around a power plant during four seasons in 2011. We measured total length of zooplankton and divided zooplankton into seven size classes in order... Zooplankton samples were collected using 505, 160 and 77 μm mesh nets around a power plant during four seasons in 2011. We measured total length of zooplankton and divided zooplankton into seven size classes in order to explore how zooplankton community size-structure might be altered by thermal discharge from power plant. The total length of zooplankton varied from 93.7 to 40 074.7 μm. The spatial distribution of mesozooplankton(200-2 000 μm) populations were rarely affected by thermal discharge, while macro-(2 000-10 000 μm)and megalo-zooplankton(>10 000 μm) had an obvious tendency to migrate away from the outfall of power plant.Thus, zooplankton community tended to become smaller and biodiversity reduced close to power plant.Moreover, we compared the zooplankton communities in three different mesh size nets. Species richness,abundance, evenness index and Shannon-Wiener diversity index of the 505 μm mesh size were significantly lower than those recorded from the 160 and 77 μm mesh size. Average zooplankton abundance was highest in the 77 μm mesh net((27 690.0±1 633.7) ind./m^3), followed by 160 μm mesh net((9 531.1±1 079.5) ind./m^3), and lowest in 505 μm mesh net((494.4±104.7) ind./m^3). The ANOSIM and SIMPER tests confirmed that these differences were mainly due to small zooplankton and early developmental stages of zooplankton. It is the first time to use the 77 μm mesh net to sample zooplankton in such an environment. The 77 μm mesh net had the overwhelming abundance of the copepod genus Oithona, as an order of magnitude greater than recorded for 160 μm mesh net and 100% loss through the 505 μm mesh net. These results indicate that the use of a small or even multiple sampling net is necessary to accurately quantify entire zooplankton community around coastal power plant. 展开更多
关键词 ZOOPLANKTON coastal power plant temperature elevation size class community structure mesh size selection
下载PDF
Valuing Health Effects of Natural Radionuclides Releases from Yatagan Power Plant
17
作者 Tayfun BUKE Aylin CiGdem KONE 《Energy and Power Engineering》 2010年第1期46-52,共7页
The objective of this paper is the valuation of radiological health effects of Yatagan Power Plant. To this aim the radiation dose calculations are carried out for the population living within 80 km radius of the plan... The objective of this paper is the valuation of radiological health effects of Yatagan Power Plant. To this aim the radiation dose calculations are carried out for the population living within 80 km radius of the plant. The average of the maximum measured specific isotopes 238U, 232Th and 226Ra in the flying ash samples are considered as radioactive sources. Based on the dose calculations, first the stochastic health effects and then monetary health effects are estimated. The estimated total collective dose and economic value of the pre-dicted health effects are 0.3098 man Sv/y and 14791 US$/y respectively. The results obtained from the dose calculations are lower than the limits of International Commission of Radiation Protection (ICRP) and it does not pose any risk for public health. Monetary value of health risks is also negligible in comparison to the av-erage yearly sales revenue of the plant which is 250 million US$. 展开更多
关键词 coal-fired power plants COLLECTIVE DOSE ATMOSPHERIC DISPERSION VALUING health effects
下载PDF
Research on Structural Design of Coal Crusher House in Thermal Power Plant
18
作者 Junhu Wang 《Journal of Architectural Environment & Structural Engineering Research》 2020年第2期14-17,共4页
This paper takes the specific characteristics of pulverized coal room in thermal power plant as the starting point,firstly,this paper analyzes the process layout and structure selection,and then the structural design ... This paper takes the specific characteristics of pulverized coal room in thermal power plant as the starting point,firstly,this paper analyzes the process layout and structure selection,and then the structural design and vibration design requirements of coal crusher house are introduced in this paper.Finally,based on the engineering example,a new structure form of vibration isolation design is creatively proposed,which provides a new design idea for the practical engineering design. 展开更多
关键词 coal-fired power plant Coal crusher house Vibration calculation Vibration isolation design
下载PDF
Distribution and bioavailability of mercury in size-fractioned atmospheric particles around an ultra-low emission power plant in Southwest China
19
作者 Wei Zhang Jinjuan Li +4 位作者 Hao Qiu Xingqiang Guo Zhijun Fei Yi Xing Deliang Yin 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2024年第4期141-152,共12页
Ultra-low emission(ULE)technology retrofits significantly impact the particulate-bound mercury(Hg)emissions from coal-fired power plants(CFPPs);however,the distribution and bioavailability of Hg in size-fractioned par... Ultra-low emission(ULE)technology retrofits significantly impact the particulate-bound mercury(Hg)emissions from coal-fired power plants(CFPPs);however,the distribution and bioavailability of Hg in size-fractioned particulate matter(PM)around the ULE-retrofitted CF-PPs are less understood.Here,total Hg and its chemical speciation in TSP(total suspended particles),PM_(10)(aerodynamic particle diameter≤10μm)and PM_(2.5)(aerodynamic particle diameter≤2.5μm)around a ULE-retrofitted CFPP in Guizhou Province were quantified.Atmospheric PM_(2.5)concentration was higher around this ULE-retrofitted CFPP than that in the intra-regional urban cities,and it had higher mass Hg concentration than other sizefractioned PM.Total Hg concentrations in PM had multifarious sources including CFPP,vehicle exhaust and biomass combustion,while they were significantly higher in autumn and winter than those in other seasons(P<0.05).Regardless of particulate size,atmospheric PM-bound Hg had lower residual fractions(<21%)while higher HCl-soluble fractions(>40%).Mass concentrations of exchangeable,HCl-soluble,elemental,and residual Hg in PM_(2.5)were higher than those in other size-fractioned PM,and were markedly elevated in autumn and winter(P<0.05).In PM_(2.5),HCl-soluble Hg presented a significantly positive relationship with elemental Hg(P<0.05),while residual Hg showed the significantly positive relationships with HCl-soluble Hg and elemental Hg(P<0.01).Overall,these results suggested that atmospheric PM-bound Hg around the ULE-retrofitted CFPP tends to accumulate in finer PM,and has higher bioavailable fractions,while has potential transformation between chemical speciation. 展开更多
关键词 Size-fractioned particles MERCURY Chemical speciation coal-fired power plant Ultra-low emission
原文传递
滨海火电厂循环水管道硫化氢气体的产生、危害及预防措施
20
作者 郑耿桦 尤亮 +8 位作者 冯庭有 江永 冯浩 李灵钰 梁淑怡 李平 王双喜 蔡润林 王慧 《汕头大学学报(自然科学版)》 2024年第3期73-80,共8页
滨海火电厂循环水管道中硫化氢等有毒有害气体的积累不仅会影响冷却系统的正常运行,还会对周边环境及现场作业人员的健康造成严重危害,是困扰火电厂安全运行的重大难题.因此,研究火电厂循环水管道中硫化氢的产生机制并针对性提出防控措... 滨海火电厂循环水管道中硫化氢等有毒有害气体的积累不仅会影响冷却系统的正常运行,还会对周边环境及现场作业人员的健康造成严重危害,是困扰火电厂安全运行的重大难题.因此,研究火电厂循环水管道中硫化氢的产生机制并针对性提出防控措施,是火电厂亟需解决的科学问题.基于此,本文从滨海火电厂循环水管道中如何产生硫化氢及防治的科学问题出发,介绍了硫化氢对环境、设备和人员的严重危害,综述了不同自然环境中硫化氢产生的机制,指出了微生物介导硫酸盐还原作用是循环水管道中硫化氢产生的关键,并根据国内外研究进展对硫化氢的防治策略进行了展望.本文对于科学防控火电厂循环水管道产生硫化氢等有毒有害气体的风险具有重要的指导意义. 展开更多
关键词 滨海火电厂 硫化氢 防控措施
下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部