In nuclear reactors,temperature fluctuations of fluids may cause fatigue damage to adjacent structures;this is referred to as thermal striping.Research on thermal striping in the upper plenum has mainly focused on flu...In nuclear reactors,temperature fluctuations of fluids may cause fatigue damage to adjacent structures;this is referred to as thermal striping.Research on thermal striping in the upper plenum has mainly focused on fluid fields.Few experimental studies have been reported on solid structures in a fluid field with a coaxial jet.This study entailed an experimental study of the temperature fluctuations in the fluid and on a plate surface caused by a coaxial jet.The temperature fluctuations of the fluid and plate surfaces located at different heights were analyzed.The cause of the temperature fluctuation was analyzed using a transient temperature distribution.The results show that the mixing of the hot and cold fluids gradually becomes uniform in the positive axial direction.The average surface temperatures tended to be consistent.When the jet reaches the plate surface,the swing of the jet center,contraction and expansion of the cold jet,and changes in the jet shape result in temperature fluctuations.The intensity of the temperature fluctuation was affected by the position.More attention should be paid when the plate is located at a lower height,and between the hot and cold-fluid nozzles.展开更多
In this study,numerical simulations of the pinching-off phenomena displayed by the dispersed phase in a continuous phase have been conducted using COMSOL Multiphysics(level-set method).Four flow patterns,namely“drop ...In this study,numerical simulations of the pinching-off phenomena displayed by the dispersed phase in a continuous phase have been conducted using COMSOL Multiphysics(level-set method).Four flow patterns,namely“drop flow”,“jet flow”,“squeeze flow”,and“co-flow”,have been obtained for different flow velocity ratios,channel diameter ratios,density ratios,viscosity ratios,and surface tension.The flow pattern map of two-phase flow in coaxial microchannels has been obtained accordingly,and the associated droplet generation process has been critically discussed considering the related frequency,diameter,and pinch-off length.In particular,it is shown that the larger the flow velocity ratio,the smaller the diameter of generated droplets and the shorter the pinch-off length.The pinch-off length of a droplet is influenced by the channel diameter ratio and density ratio.The changes in viscosity ratio have a negligible influence on the droplet generation pinching frequency.With an increase in surface tension,the frequency of generation and pinch-off length of droplets decrease,but for small surface tension the generation diameter of droplet increases.展开更多
Hexagonal boron nitride nanosheets(BNNSs)exhibit remarkable thermal and dielectric properties.However,their self-assembly and alignment in macroscopic forms remain challenging due to the chemical inertness of boron ni...Hexagonal boron nitride nanosheets(BNNSs)exhibit remarkable thermal and dielectric properties.However,their self-assembly and alignment in macroscopic forms remain challenging due to the chemical inertness of boron nitride,thereby limiting their performance in applications such as thermal management.In this study,we present a coaxial wet spinning approach for the fabrication of BNNSs/polymer composite fibers with high nanosheet orientation.The composite fibers were prepared using a superacid-based solvent system and showed a layered structure comprising an aramid core and an aramid/BNNSs sheath.Notably,the coaxial fibers exhibited significantly higher BNNSs alignment compared to uniaxial aramid/BNNSs fibers,primarily due to the additional compressive forces exerted at the core-sheath interface during the hot drawing process.With a BNNSs loading of 60 wt%,the resulting coaxial fibers showed exceptional properties,including an ultrahigh Herman orientation parameter of 0.81,thermal conductivity of 17.2 W m^(-1)K^(-1),and tensile strength of 192.5 MPa.These results surpassed those of uniaxial fibers and previously reported BNNSs composite fibers,making them highly suitable for applications such as wearable thermal management textiles.Our findings present a promising strategy for fabricating high-performance composite fibers based on BNNSs.展开更多
Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In...Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources.展开更多
BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guide...BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue.展开更多
Firefighting protective clothing is a crucial protective equipment for firefighters to minimize skin burn and ensure safety firefighting operation and rescue mission.A recent increasing concern is to develop self-powe...Firefighting protective clothing is a crucial protective equipment for firefighters to minimize skin burn and ensure safety firefighting operation and rescue mission.A recent increasing concern is to develop self-powered fire warning materials that can be incorporated into the firefighting clothing to achieve active fire protection for firefighters before the protective clothing catches fire on fireground.However,it is still a challenge to facilely design and manufacture thermoelectric(TE)textile(TET)-based fire warning electronics with dynamic surface conformability and breathability.Here,we develop an alternate coaxial wet-spinning strategy to continuously produce alternating p/n-type TE aerogel fibers involving n-type Ti_(3)C_(2)T_(x)MXene and p-type MXene/SWCNT-COOH as core materials,and tough aramid nanofiber as protective shell,which simultaneously ensure the flexibility and high-efficiency TE power generation.With such alternating p/n-type TE fibers,TET-based self-powered fire warning sensors with high mechanical stability and wearability are successfully fabricated through stitching the alternating p-n segment TE fibers into aramid fabric.The results indicate that TET-based fire warning electronics containing 50 p-n pairs produce the open-circuit voltage of 7.5 mV with a power density of 119.79 nW cm-2 at a temperature difference of 300℃.The output voltage signal is then calculated as corresponding surface temperature of firefighting clothing based on a linear relationship between TE voltage and temperature.The fire alarm response time and flame-retardant properties are further displayed.Such self-powered fire warning electronics are true textiles that offer breathability and compatibility with body movement,demonstrating their potential application in firefighting clothing.展开更多
The so-called coaxial compound helicopter features two rigid coaxial rotors,and possesses high-speed capabilities.Nevertheless,the small separation of the coaxial rotors causes severe aerodynamic interactions,which re...The so-called coaxial compound helicopter features two rigid coaxial rotors,and possesses high-speed capabilities.Nevertheless,the small separation of the coaxial rotors causes severe aerodynamic interactions,which require careful analysis.In the present work,the aerodynamic interaction between the various helicopter components is investigated by means of a numerical method considering both hover and forward flight conditions.While a sliding mesh method is used to deal with the rotating coaxial rotors,the Reynolds-Averaged Navier-Stokes(RANS)equations are solved for the flow field.The Caradonna&Tung(CT)rotor and Harrington-2 coaxial rotor are considered to validate the numerical method.The results show that the aerodynamic interaction of the two rigid coaxial rotors significantly influences hover’s induced velocity and pressure distribution.In addition,the average thrust of an isolated coaxial rotor is smaller than that of the corresponding isolated single rotor.Compared with the isolated coaxial rotor,the existence of the fuselage results in an increment in the thrust of the rotors.Furthermore,these interactions between the components of the considered coaxial compound helicopter decay with an increase in the advance ratio.展开更多
To address the restriction of fiber-optic surface plasmon resonance(SPR) sensors in the field of multi-sample detection, a novel dual-channel fiber-optic SPR sensor based on the cascade of coaxial dual-waveguide D-typ...To address the restriction of fiber-optic surface plasmon resonance(SPR) sensors in the field of multi-sample detection, a novel dual-channel fiber-optic SPR sensor based on the cascade of coaxial dual-waveguide D-type structure and microsphere structure is proposed in this paper. The fiber sidepolishing technique converts the coaxial dual-waveguide fiber into a D-type one, and the evanescent wave in the ring core leaks, generating a D-type sensing region;the fiber optic fused ball push technology converts the coaxial dual waveguides into microspheres, and the stimulated cladding mode evanescent wave leaks, producing the microsphere sensing region. By injecting light into the coaxial dual-waveguide middle core alone, the sensor can realize single-stage sensing in the microsphere sensing area;it can also realize dual-channel sensing in the D-type sensing area and microsphere sensing area by injecting light into the ring core. The refractive index measurement ranges for the two channels are 1.333–1.365 and 1.375–1.405, respectively, with detection sensitivities of 981.56 nm/RIU and 4138 nm/RIU. The sensor combines wavelength division multiplexing and space division multiplexing technologies, presenting a novel research concept for multi-channel fiber SPR sensors.展开更多
Dielectric barrier discharge (DBD) has been widely employed in ozone generation.However,the technology still exhibits relatively low energy yield (E_(Y)) referring to its theoretical value.In this work,E_(Y)of ozone g...Dielectric barrier discharge (DBD) has been widely employed in ozone generation.However,the technology still exhibits relatively low energy yield (E_(Y)) referring to its theoretical value.In this work,E_(Y)of ozone generation was improved by optimizing the mesh number,electrode length,and dielectric material in a coaxial DBD reactor with two wire mesh electrodes.Meanwhile,the discharge characteristics were investigated to elucidate the effect of reactor configuration on E_(Y).Results showed that the discharge characteristics were improved by increasing the mesh number,electrode length,and relative permittivity.When the mesh number was increased from 40 to 100,an improvement of approximately 48%in E_(Y) was obtained.Additionally,higher E_(Y) values were obtained using corundum as the dielectric material relative to polytetrafluoroethylene and quartz.Ultimately,E_(Y) in the optimal DBD reactor could reach 326.77 g·(k W·h)^(-1).Compared with the reported DBD reactor,the coaxial DBD reactor with the mesh electrode and the dielectric material of corundum could effectively improve E_(Y),which lays a foundation for the design of high-efficiency coaxial DBD reactor.展开更多
As an important wave energy converter(WEC),the double-buoy device has advantages of wider energy absorption band and deeper water adaptability,which attract an increasing number of attentions from researchers.This pap...As an important wave energy converter(WEC),the double-buoy device has advantages of wider energy absorption band and deeper water adaptability,which attract an increasing number of attentions from researchers.This paper makes an in-depth study on double-buoy WEC,by means of the combination of model experiment and numerical simulation.The Response Amplitude Operator(RAO)and energy capture of the double-buoy under constant power take-off(PTO)damping are investigated in the model test,while the average power output and capture width ratio(CWR)are calculated by the numerical simulation to analyze the influence of the wave condition,PTO,and the geometry parameters of the device.The AQWA-Fortran united simulation sy stem,including the secondary developme nt of AQWA software coupled with the flowchart of the Fortran code,models a new dynamic system.Various viscous damping and hydraulic friction from WEC system are measured from the experimental results,and these values are added to the equation of motion.As a result,the energy loss is contained in the final numerical model the by united simulation system.Using the developed numerical model,the optimal period of energy capture is identified.The power capture reaches the maximum value under the outer buoy's natural period.The paper gives the peak value of the energy capture under the linear PTO damping force,and calculates the optimal mass ratio of the device.展开更多
BACKGROUND The coaxial radiography-guided puncture technique(CR-PT)is a novel technique for endoscopic lumbar discectomy.As the X-ray beam and the puncturing needle are maintained in a parallel and coaxial direction,t...BACKGROUND The coaxial radiography-guided puncture technique(CR-PT)is a novel technique for endoscopic lumbar discectomy.As the X-ray beam and the puncturing needle are maintained in a parallel and coaxial direction,the X-ray beam can be used to guide the trajectory angle,facilitating the choice of the puncture site and providing real-time guidance.This puncture technique offers numerous advantages over the conventional anterior-posterior and lateral radiography-guided puncture technique(AP-PT),especially in cases of herniated lumbar discs with a hypertrophied transverse process or articular process,high iliac crest,and narrowed intervertebral foramen.AIM To confirm whether CR-PT is a superior approach to percutaneous transforaminal endoscopic lumbar discectomy compared to AP-PT.METHODS In this parallel,controlled,randomized clinical trial,herniated lumbar disc patients appointed to receive percutaneous endoscopic lumbar discectomy treatment were recruited from the Pain Management Department of the Affiliated Hospital of Xuzhou Medical University and Nantong Hospital of Traditional Chinese Medicine.Sixty-five participants were enrolled and divided into either a CR-PT group or an AP-PT group.The CR-PT group underwent CR-PT,and the AP-PT group underwent AP-PT.The number of fluoroscopies during puncturing,puncture duration(min),surgery duration(min),VAS score during puncturing,and puncture success rate were recorded.RESULTS Sixty-five participants were included,with 31 participants in the CR-PT group and 34 in the AP-PT group.One participant in the AP-PT group dropped out due to unsuccessful puncturing.The number of fluoroscopies[median(P25,P75)]was 12(11,14)in the CR-PT group vs 16(12,23)in the AP-PT group,while the puncture duration(mean±SD)was 20.42±5.78 vs 25.06±5.46,respectively.The VAS score was 3(2,4)in the CR-PT group vs 3(3,4)in the AP-PT group.Further subgroup analysis was performed,considering only the participants with L5/S1 segment herniation:9 patients underwent CR-PT,and 9 underwent AP-PT.The number of fluoroscopies was 11.56±0.88 vs 25.22±5.33;the puncture duration was 13.89±1.45 vs 28.89±3.76;the surgery duration was 105(99.5,120)vs 149(125,157.5);and the VAS score was 2.11±0.93 vs 3.89±0.6,respectively.All the above outcomes demonstrated statistical significance(P<0.05),favoring the CR-PT treatment.CONCLUSION CR-PT is a novel and effective technique.As opposed to conventional AP-PT,this technique significantly improves puncture accuracy,shortens puncture time and operation time,and reduces pain intensity during puncturing.展开更多
It is of significance to construct continuous multiphase percolation channels with fast lithium-ion pathway in hybrid solid electrolytes.3D ceramic nanostructure frameworks have attracted great attention in this field...It is of significance to construct continuous multiphase percolation channels with fast lithium-ion pathway in hybrid solid electrolytes.3D ceramic nanostructure frameworks have attracted great attention in this field.Herein,the three-dimensional perovskite Li_(0.33)La_(0.557)TiO_(3)nanotubes framework(3D-LLTO-NT)is fabricated via a facile coaxial electro-spinning process followed by a calcination process at 800°C.The hybrid polymer electrolyte of 3DLLTO-NT framework and poly(ethylene carbonate)(3D-LLTO-NT@PEC)shows improved ionic conductivity of 1.73×10^(-4)S cm^(-1)at ambient temperature,higher lithium-ion transference number(t_(Li)^(+))of 0.78 and electrochemical stability window up to 5.0 V vs Li/Li^(+).The all-solid-state cell of LiFePO_(4)/3D-LLTO-NT@PEC/Li delivers a high specific capacity of 140.2 mAh g^(-1)at 0.1 C at ambient temperature.This outstanding performance is attributed to the 3D ceramic nanotubes frameworks which provide fast lithium ion transfer pathway and stable interfaces.展开更多
基金supported by the National Natural Science Foundation of China (No. 52075173)the Overseas Expertise Introduction Project for Discipline Innovation (No. B13020)
文摘In nuclear reactors,temperature fluctuations of fluids may cause fatigue damage to adjacent structures;this is referred to as thermal striping.Research on thermal striping in the upper plenum has mainly focused on fluid fields.Few experimental studies have been reported on solid structures in a fluid field with a coaxial jet.This study entailed an experimental study of the temperature fluctuations in the fluid and on a plate surface caused by a coaxial jet.The temperature fluctuations of the fluid and plate surfaces located at different heights were analyzed.The cause of the temperature fluctuation was analyzed using a transient temperature distribution.The results show that the mixing of the hot and cold fluids gradually becomes uniform in the positive axial direction.The average surface temperatures tended to be consistent.When the jet reaches the plate surface,the swing of the jet center,contraction and expansion of the cold jet,and changes in the jet shape result in temperature fluctuations.The intensity of the temperature fluctuation was affected by the position.More attention should be paid when the plate is located at a lower height,and between the hot and cold-fluid nozzles.
基金funded by University Natural Science Research Project of Anhui Province,Grant Numbers (KJ2020A0826,2022AH051885,2022AH051891,2022AH030160,62303231)Intelligent Detection Research Team Funds for the Anhui Institute of Information Technology,Grant Number (AXG2023_kjc_5004).
文摘In this study,numerical simulations of the pinching-off phenomena displayed by the dispersed phase in a continuous phase have been conducted using COMSOL Multiphysics(level-set method).Four flow patterns,namely“drop flow”,“jet flow”,“squeeze flow”,and“co-flow”,have been obtained for different flow velocity ratios,channel diameter ratios,density ratios,viscosity ratios,and surface tension.The flow pattern map of two-phase flow in coaxial microchannels has been obtained accordingly,and the associated droplet generation process has been critically discussed considering the related frequency,diameter,and pinch-off length.In particular,it is shown that the larger the flow velocity ratio,the smaller the diameter of generated droplets and the shorter the pinch-off length.The pinch-off length of a droplet is influenced by the channel diameter ratio and density ratio.The changes in viscosity ratio have a negligible influence on the droplet generation pinching frequency.With an increase in surface tension,the frequency of generation and pinch-off length of droplets decrease,but for small surface tension the generation diameter of droplet increases.
基金This work was supported by the National Key Research and Development Project(Nos.2019YFA0705403,2022YFA1205300)the National Natural Science Foundation of China(No.T2293693)+3 种基金the Guangdong Innovative and Entrepreneurial Research Team Program(No.2017ZT07C341)the Guangdong Basic and Applied Basic Research Foundation(No.2020B0301030002)the Shenzhen Basic Research Project(Nos.WDZC20200824091903001,JSGG20220831105402004)Zhiyuan Xiong thanks the financial support from South China University of Technology.
文摘Hexagonal boron nitride nanosheets(BNNSs)exhibit remarkable thermal and dielectric properties.However,their self-assembly and alignment in macroscopic forms remain challenging due to the chemical inertness of boron nitride,thereby limiting their performance in applications such as thermal management.In this study,we present a coaxial wet spinning approach for the fabrication of BNNSs/polymer composite fibers with high nanosheet orientation.The composite fibers were prepared using a superacid-based solvent system and showed a layered structure comprising an aramid core and an aramid/BNNSs sheath.Notably,the coaxial fibers exhibited significantly higher BNNSs alignment compared to uniaxial aramid/BNNSs fibers,primarily due to the additional compressive forces exerted at the core-sheath interface during the hot drawing process.With a BNNSs loading of 60 wt%,the resulting coaxial fibers showed exceptional properties,including an ultrahigh Herman orientation parameter of 0.81,thermal conductivity of 17.2 W m^(-1)K^(-1),and tensile strength of 192.5 MPa.These results surpassed those of uniaxial fibers and previously reported BNNSs composite fibers,making them highly suitable for applications such as wearable thermal management textiles.Our findings present a promising strategy for fabricating high-performance composite fibers based on BNNSs.
基金supported by Bhabha Atomic Research Centre, Department of Atomic Energy, Government of IndiaDepartment of Atomic Energy, Government of India for financial assistance under DAE Doctoral Fellowship Scheme-2018。
文摘Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources.
文摘BACKGROUND The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma.Consequently,a definitive diagnosis primarily relies on his-tological results.The ultrasound(US)-guided coaxial core needle biopsy(CNB)not only procures sufficient tissue to help clarify the diagnosis,but reduces the incidence of puncture-related complications.CASE SUMMARY A 41-year-old female,with a history of pulmonary tuberculosis,was admitted to our hospital with multiple indeterminate splenic lesions.Gray-scale ultrasono-graphy demonstrated splenomegaly with numerous well-defined hypoechoic ma-sses.Abdominal contrast-enhanced computed tomography(CT)showed an en-larged spleen with multiple irregular-shaped,peripherally enhancing,hypodense lesions.Positron emission CT revealed numerous abnormal hyperglycemia foci.These imaging findings strongly indicated the possibility of infectious disease as the primary concern,with neoplastic lesions requiring exclusion.To obtain the precise pathological diagnosis,the US-guided coaxial CNB of the spleen was ca-rried out.The patient did not express any discomfort during the procedure.CONCLUSION Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples,as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and sur-rounding tissue.
基金This work was financially supported by the Opening Project of National Local Joint Laboratory for Advanced Textile Processing and Clean Production(FX2022006)Guiding Project of Natural Science Foundation of Hubei province(2022CFC072)+2 种基金Guiding Project of Scientific Research Plan of Education Department of Hubei Province(B2022081)Shenghong Key Scientific Research Project of Emergency Support and Public Safety Fiber Materials and Products(2022-rw0101)Science and Technology Guidance Program of China National Textile and Apparel Council(2022002).
文摘Firefighting protective clothing is a crucial protective equipment for firefighters to minimize skin burn and ensure safety firefighting operation and rescue mission.A recent increasing concern is to develop self-powered fire warning materials that can be incorporated into the firefighting clothing to achieve active fire protection for firefighters before the protective clothing catches fire on fireground.However,it is still a challenge to facilely design and manufacture thermoelectric(TE)textile(TET)-based fire warning electronics with dynamic surface conformability and breathability.Here,we develop an alternate coaxial wet-spinning strategy to continuously produce alternating p/n-type TE aerogel fibers involving n-type Ti_(3)C_(2)T_(x)MXene and p-type MXene/SWCNT-COOH as core materials,and tough aramid nanofiber as protective shell,which simultaneously ensure the flexibility and high-efficiency TE power generation.With such alternating p/n-type TE fibers,TET-based self-powered fire warning sensors with high mechanical stability and wearability are successfully fabricated through stitching the alternating p-n segment TE fibers into aramid fabric.The results indicate that TET-based fire warning electronics containing 50 p-n pairs produce the open-circuit voltage of 7.5 mV with a power density of 119.79 nW cm-2 at a temperature difference of 300℃.The output voltage signal is then calculated as corresponding surface temperature of firefighting clothing based on a linear relationship between TE voltage and temperature.The fire alarm response time and flame-retardant properties are further displayed.Such self-powered fire warning electronics are true textiles that offer breathability and compatibility with body movement,demonstrating their potential application in firefighting clothing.
基金supported by Rotor Aerodynamics Key Laboratory[Grant No.RAL202102-4].
文摘The so-called coaxial compound helicopter features two rigid coaxial rotors,and possesses high-speed capabilities.Nevertheless,the small separation of the coaxial rotors causes severe aerodynamic interactions,which require careful analysis.In the present work,the aerodynamic interaction between the various helicopter components is investigated by means of a numerical method considering both hover and forward flight conditions.While a sliding mesh method is used to deal with the rotating coaxial rotors,the Reynolds-Averaged Navier-Stokes(RANS)equations are solved for the flow field.The Caradonna&Tung(CT)rotor and Harrington-2 coaxial rotor are considered to validate the numerical method.The results show that the aerodynamic interaction of the two rigid coaxial rotors significantly influences hover’s induced velocity and pressure distribution.In addition,the average thrust of an isolated coaxial rotor is smaller than that of the corresponding isolated single rotor.Compared with the isolated coaxial rotor,the existence of the fuselage results in an increment in the thrust of the rotors.Furthermore,these interactions between the components of the considered coaxial compound helicopter decay with an increase in the advance ratio.
基金supported by the National Natural Science Foundation of China (Grant No. 61705025)the Natural Science Foundation of Chongqing (Grant Nos. cstc2019jcyjmsxm X043 and cstc2018jcyj AX0817)+2 种基金the Fund from the Science and Technology Project Affiliated to the Education Department of Chongqing Municipality (Grant Nos. KJQN201801217, KJQN202001214, KJQN201901226, and KJ1710247)the Fund from Chongqing Key Laboratory of Geological Environment Monitoring and Disaster Early-Warning in Three Gorges Reservoir Area (Grant Nos. ZD2020A0103 and ZD2020A0102)the Fundamental Research Funds for Chongqing Three Gorges University of China (Grant No. 19ZDPY08)。
文摘To address the restriction of fiber-optic surface plasmon resonance(SPR) sensors in the field of multi-sample detection, a novel dual-channel fiber-optic SPR sensor based on the cascade of coaxial dual-waveguide D-type structure and microsphere structure is proposed in this paper. The fiber sidepolishing technique converts the coaxial dual-waveguide fiber into a D-type one, and the evanescent wave in the ring core leaks, generating a D-type sensing region;the fiber optic fused ball push technology converts the coaxial dual waveguides into microspheres, and the stimulated cladding mode evanescent wave leaks, producing the microsphere sensing region. By injecting light into the coaxial dual-waveguide middle core alone, the sensor can realize single-stage sensing in the microsphere sensing area;it can also realize dual-channel sensing in the D-type sensing area and microsphere sensing area by injecting light into the ring core. The refractive index measurement ranges for the two channels are 1.333–1.365 and 1.375–1.405, respectively, with detection sensitivities of 981.56 nm/RIU and 4138 nm/RIU. The sensor combines wavelength division multiplexing and space division multiplexing technologies, presenting a novel research concept for multi-channel fiber SPR sensors.
基金supported by the National Natural Science Foundation of China (21725601 and 2187081058)。
文摘Dielectric barrier discharge (DBD) has been widely employed in ozone generation.However,the technology still exhibits relatively low energy yield (E_(Y)) referring to its theoretical value.In this work,E_(Y)of ozone generation was improved by optimizing the mesh number,electrode length,and dielectric material in a coaxial DBD reactor with two wire mesh electrodes.Meanwhile,the discharge characteristics were investigated to elucidate the effect of reactor configuration on E_(Y).Results showed that the discharge characteristics were improved by increasing the mesh number,electrode length,and relative permittivity.When the mesh number was increased from 40 to 100,an improvement of approximately 48%in E_(Y) was obtained.Additionally,higher E_(Y) values were obtained using corundum as the dielectric material relative to polytetrafluoroethylene and quartz.Ultimately,E_(Y) in the optimal DBD reactor could reach 326.77 g·(k W·h)^(-1).Compared with the reported DBD reactor,the coaxial DBD reactor with the mesh electrode and the dielectric material of corundum could effectively improve E_(Y),which lays a foundation for the design of high-efficiency coaxial DBD reactor.
基金financially supported by the National Key R&D Program of China (Grant No.2018YFB1501900)the Shandong Provincial Natural Science Foundation (Grant No.ZR2021ZD23)+3 种基金Qingdao Postdoctoral Program (Grant No.QDBSH20220201015)the Fundamental Research Funds for the Central Universities (Grant No.202313031)the National Natural Science Foundation of China (Grant No.52071303)the Taishan Scholars Program of Shandong Province (Grant No.ts20190914)。
文摘As an important wave energy converter(WEC),the double-buoy device has advantages of wider energy absorption band and deeper water adaptability,which attract an increasing number of attentions from researchers.This paper makes an in-depth study on double-buoy WEC,by means of the combination of model experiment and numerical simulation.The Response Amplitude Operator(RAO)and energy capture of the double-buoy under constant power take-off(PTO)damping are investigated in the model test,while the average power output and capture width ratio(CWR)are calculated by the numerical simulation to analyze the influence of the wave condition,PTO,and the geometry parameters of the device.The AQWA-Fortran united simulation sy stem,including the secondary developme nt of AQWA software coupled with the flowchart of the Fortran code,models a new dynamic system.Various viscous damping and hydraulic friction from WEC system are measured from the experimental results,and these values are added to the equation of motion.As a result,the energy loss is contained in the final numerical model the by united simulation system.Using the developed numerical model,the optimal period of energy capture is identified.The power capture reaches the maximum value under the outer buoy's natural period.The paper gives the peak value of the energy capture under the linear PTO damping force,and calculates the optimal mass ratio of the device.
文摘BACKGROUND The coaxial radiography-guided puncture technique(CR-PT)is a novel technique for endoscopic lumbar discectomy.As the X-ray beam and the puncturing needle are maintained in a parallel and coaxial direction,the X-ray beam can be used to guide the trajectory angle,facilitating the choice of the puncture site and providing real-time guidance.This puncture technique offers numerous advantages over the conventional anterior-posterior and lateral radiography-guided puncture technique(AP-PT),especially in cases of herniated lumbar discs with a hypertrophied transverse process or articular process,high iliac crest,and narrowed intervertebral foramen.AIM To confirm whether CR-PT is a superior approach to percutaneous transforaminal endoscopic lumbar discectomy compared to AP-PT.METHODS In this parallel,controlled,randomized clinical trial,herniated lumbar disc patients appointed to receive percutaneous endoscopic lumbar discectomy treatment were recruited from the Pain Management Department of the Affiliated Hospital of Xuzhou Medical University and Nantong Hospital of Traditional Chinese Medicine.Sixty-five participants were enrolled and divided into either a CR-PT group or an AP-PT group.The CR-PT group underwent CR-PT,and the AP-PT group underwent AP-PT.The number of fluoroscopies during puncturing,puncture duration(min),surgery duration(min),VAS score during puncturing,and puncture success rate were recorded.RESULTS Sixty-five participants were included,with 31 participants in the CR-PT group and 34 in the AP-PT group.One participant in the AP-PT group dropped out due to unsuccessful puncturing.The number of fluoroscopies[median(P25,P75)]was 12(11,14)in the CR-PT group vs 16(12,23)in the AP-PT group,while the puncture duration(mean±SD)was 20.42±5.78 vs 25.06±5.46,respectively.The VAS score was 3(2,4)in the CR-PT group vs 3(3,4)in the AP-PT group.Further subgroup analysis was performed,considering only the participants with L5/S1 segment herniation:9 patients underwent CR-PT,and 9 underwent AP-PT.The number of fluoroscopies was 11.56±0.88 vs 25.22±5.33;the puncture duration was 13.89±1.45 vs 28.89±3.76;the surgery duration was 105(99.5,120)vs 149(125,157.5);and the VAS score was 2.11±0.93 vs 3.89±0.6,respectively.All the above outcomes demonstrated statistical significance(P<0.05),favoring the CR-PT treatment.CONCLUSION CR-PT is a novel and effective technique.As opposed to conventional AP-PT,this technique significantly improves puncture accuracy,shortens puncture time and operation time,and reduces pain intensity during puncturing.
基金financial support from Key Scientific and Technological Project of Wuhan City(Grant no.2018010401011279)Team Innovation Foundation of Hubei province(Grant no.T201935)National Natural Science Foundation of China(Grant nos.51872127,22209059 and 22139001)
文摘It is of significance to construct continuous multiphase percolation channels with fast lithium-ion pathway in hybrid solid electrolytes.3D ceramic nanostructure frameworks have attracted great attention in this field.Herein,the three-dimensional perovskite Li_(0.33)La_(0.557)TiO_(3)nanotubes framework(3D-LLTO-NT)is fabricated via a facile coaxial electro-spinning process followed by a calcination process at 800°C.The hybrid polymer electrolyte of 3DLLTO-NT framework and poly(ethylene carbonate)(3D-LLTO-NT@PEC)shows improved ionic conductivity of 1.73×10^(-4)S cm^(-1)at ambient temperature,higher lithium-ion transference number(t_(Li)^(+))of 0.78 and electrochemical stability window up to 5.0 V vs Li/Li^(+).The all-solid-state cell of LiFePO_(4)/3D-LLTO-NT@PEC/Li delivers a high specific capacity of 140.2 mAh g^(-1)at 0.1 C at ambient temperature.This outstanding performance is attributed to the 3D ceramic nanotubes frameworks which provide fast lithium ion transfer pathway and stable interfaces.