Based on the transmission line code (TLCODE), a circuit model is developed here for analyses of main switches in the high pulsed-power facilities. With the structure of the ZR main switch as an example, a circuit mo...Based on the transmission line code (TLCODE), a circuit model is developed here for analyses of main switches in the high pulsed-power facilities. With the structure of the ZR main switch as an example, a circuit model topology of the switch is proposed, and in particular, calculation methods of the dynamic inductance and resistance of the switching arc are described. Moreover, a set of closed equations used for calculations of various node voltages are theoretically derived and numericMly discretized. Based on these discrete equations and the Matlab program, a simulation procedure is established for analyses of the ZR main switch. Voltages and currents at different key points are obtained, and comparisons are made with those of a PSpice L-C model. The comparison results show that these two models are perfectly in accord with each other with discrepancy less than 0.1%, which verifies the effectiveness of the TLCODE model to a certain extent.展开更多
脉冲噪声是影响电力线通信性能的最主要因素。为了提升极化码在电力线信道的性能,文章提出了分段循环冗余校验码辅助串行抵消列表比特翻转(segmented CRC aid SCL-bit flip,SCA-SCL-BF)译码算法,并在加性高斯白噪声(additive white gaus...脉冲噪声是影响电力线通信性能的最主要因素。为了提升极化码在电力线信道的性能,文章提出了分段循环冗余校验码辅助串行抵消列表比特翻转(segmented CRC aid SCL-bit flip,SCA-SCL-BF)译码算法,并在加性高斯白噪声(additive white gaussian noise,AWGN)信道和电力线信道下进行了仿真。在构造关键集合时引入Rate1子块,避免了全集搜索的复杂度;根据关键集合中比特的位置进行分段,每段翻转一比特,可以实现多比特翻转。仿真结果表明,SCA-SCL-BF算法的性能相较于公开文献中性能在信噪比(signal-to-noiseratios,SNR)大于0dB时有显著提升。该算法对于提升电力线传输性能有重要意义。展开更多
Based on the transmission line code TLCODE, a 1D circuit model for a transmission- line impedance transformer was developed and the simulation results were compared with those in the literature. The model was used to ...Based on the transmission line code TLCODE, a 1D circuit model for a transmission- line impedance transformer was developed and the simulation results were compared with those in the literature. The model was used to quantify the efficiencies of voltage-transport, energy- transport and power-transport for a transmission-line impedance transformer as functions of ψ (the ratio of the output impedance to the input impedance of the transformer) and Г (the ratio of the pulse width to the one-way transit time of the transformer) under a large scale of m (the coefficient of the generalized exponential impedance profile). Simulation results suggest that with the increase in Г, from 0 to ∞, the power transport efficiency first increases and then decreases. The maximum power transport efficiency can reach 90% or even higher for an exponential impedance profile (m = 1). With a consideration of dissipative loss in the dielectric and electrodes of the transformer, two representative designs of the water-insulated transformer are investigated for the next generation of petawatt-class z-pinch drivers. It is found that the dissipative losses in the electrodes are negligibly small, below 0.1%, but the dissipative loss in the water dielectric is about 1% to 4%.展开更多
In order to exploit the evolution and find novel low-molecular-weight glutenin subunit (LMW-GS) for improvement of common wheat quality, thirteen variants from a somatic hybrid introgression line II-12 between Triti...In order to exploit the evolution and find novel low-molecular-weight glutenin subunit (LMW-GS) for improvement of common wheat quality, thirteen variants from a somatic hybrid introgression line II-12 between Triticum aestivum cv. Jinan 177 (JN177) and Agropyron elongatum were characterized via genomic PCR. Four clones were pseudogenes because they contained an internal stop codon. The remaining nine variants contained intact open reading frames (ORFs). Sequence alignment indicates that the proteins deduced from the nine ORFs have similar primary structure with LMW-GS cloned from its parents previously. However, they have some unique modifications in the structures. For example, EU292737 contains not only an extra Cys residue in the C-terminal domain but also a long repetitive domain. Both EU 159511 and EU292738 start their first Cys residue in the N-terminal repetitive domain, but not in the N-conserved domain traditionally. These structural alterations may have positive contributions to wheat flour quality. The results of phylogeny showed that most LMW-GS variances from 11-12 were homologous to those from parent JN177 and other wheat lines. The reason for quick evolution of LMW-GS in 11-12 was discussed.展开更多
基金supported by National Natural Science Foundation of China(Nos.51307141,51077111)by the State Key Laboratory Foundational Research Funds of China(Nos.SKLIPR1302Z,SKLIPR1306)
文摘Based on the transmission line code (TLCODE), a circuit model is developed here for analyses of main switches in the high pulsed-power facilities. With the structure of the ZR main switch as an example, a circuit model topology of the switch is proposed, and in particular, calculation methods of the dynamic inductance and resistance of the switching arc are described. Moreover, a set of closed equations used for calculations of various node voltages are theoretically derived and numericMly discretized. Based on these discrete equations and the Matlab program, a simulation procedure is established for analyses of the ZR main switch. Voltages and currents at different key points are obtained, and comparisons are made with those of a PSpice L-C model. The comparison results show that these two models are perfectly in accord with each other with discrepancy less than 0.1%, which verifies the effectiveness of the TLCODE model to a certain extent.
文摘脉冲噪声是影响电力线通信性能的最主要因素。为了提升极化码在电力线信道的性能,文章提出了分段循环冗余校验码辅助串行抵消列表比特翻转(segmented CRC aid SCL-bit flip,SCA-SCL-BF)译码算法,并在加性高斯白噪声(additive white gaussian noise,AWGN)信道和电力线信道下进行了仿真。在构造关键集合时引入Rate1子块,避免了全集搜索的复杂度;根据关键集合中比特的位置进行分段,每段翻转一比特,可以实现多比特翻转。仿真结果表明,SCA-SCL-BF算法的性能相较于公开文献中性能在信噪比(signal-to-noiseratios,SNR)大于0dB时有显著提升。该算法对于提升电力线传输性能有重要意义。
基金supported by National Natural Science Foundation of China(No.50637010)
文摘Based on the transmission line code TLCODE, a 1D circuit model for a transmission- line impedance transformer was developed and the simulation results were compared with those in the literature. The model was used to quantify the efficiencies of voltage-transport, energy- transport and power-transport for a transmission-line impedance transformer as functions of ψ (the ratio of the output impedance to the input impedance of the transformer) and Г (the ratio of the pulse width to the one-way transit time of the transformer) under a large scale of m (the coefficient of the generalized exponential impedance profile). Simulation results suggest that with the increase in Г, from 0 to ∞, the power transport efficiency first increases and then decreases. The maximum power transport efficiency can reach 90% or even higher for an exponential impedance profile (m = 1). With a consideration of dissipative loss in the dielectric and electrodes of the transformer, two representative designs of the water-insulated transformer are investigated for the next generation of petawatt-class z-pinch drivers. It is found that the dissipative losses in the electrodes are negligibly small, below 0.1%, but the dissipative loss in the water dielectric is about 1% to 4%.
基金supported by the National High Technology Research and Development Program(No.2006AA10Z173 and 2006011001020)the Natural Science Foundation of Shandong Province(Y2007D48)
文摘In order to exploit the evolution and find novel low-molecular-weight glutenin subunit (LMW-GS) for improvement of common wheat quality, thirteen variants from a somatic hybrid introgression line II-12 between Triticum aestivum cv. Jinan 177 (JN177) and Agropyron elongatum were characterized via genomic PCR. Four clones were pseudogenes because they contained an internal stop codon. The remaining nine variants contained intact open reading frames (ORFs). Sequence alignment indicates that the proteins deduced from the nine ORFs have similar primary structure with LMW-GS cloned from its parents previously. However, they have some unique modifications in the structures. For example, EU292737 contains not only an extra Cys residue in the C-terminal domain but also a long repetitive domain. Both EU 159511 and EU292738 start their first Cys residue in the N-terminal repetitive domain, but not in the N-conserved domain traditionally. These structural alterations may have positive contributions to wheat flour quality. The results of phylogeny showed that most LMW-GS variances from 11-12 were homologous to those from parent JN177 and other wheat lines. The reason for quick evolution of LMW-GS in 11-12 was discussed.