期刊文献+
共找到440篇文章
< 1 2 22 >
每页显示 20 50 100
Effect of an Internal Heat Exchanger on the Performances of a Double Evaporator Ejector Refrigeration Cycle
1
作者 Rachedi Khadraoui Latra Boumaraf Philippe Haberschill 《Fluid Dynamics & Materials Processing》 EI 2023年第5期1115-1128,共14页
A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by... A theoretical investigation is presented about a double evaporator ejector refrigeration cycle(DEERC).Special attention is paid to take into account the influence of the sub-cooling and superheating effects induced by an internal heat exchanger(IHX).The ejector is introduced into the baseline cycle in order to mitigate the throttling process losses and increase the compressor suction pressure.Moreover,the IHX has the structure of a concentric counter-flow type heat exchanger and is intentionally used to ensure that the fluid at the compressor inlet is vapor.To assess accurately the influence of the IHX on the DEERC performance,a mathematical model is derived in the frame of the dominant one-dimensional theory for ejectors.The model also accounts for the friction effect in the ejector mixing section.The equations of this model are solved using an Engineering Equation Solver(EES)for different fluids.These are:R134a as baseline fluid and other environment friendly refrigerants used for comparison,namely,R1234yf,R1234ze,R600,R600a,R290,R717 and R1270.The simulation results show that the DEERC with an IHX can achieve COP(the coefficient of performance)improvements from 5.2 until 10%. 展开更多
关键词 refrigeration cycle double evaporator EJECTOR IHX performance improvement environment-friendlyrefrigerants
下载PDF
A Review on Technologies for the Use of CO2 as a Working Fluid in Refrigeration and Power Cycles
2
作者 Orelien T. Boupda Hyacinthe D. Tessemo +3 位作者 Isidore B. Nkounda Fongang Francklin G. Nyami Frederic Lontsi Thomas Djiako 《Energy and Power Engineering》 2024年第6期217-256,共40页
The use of carbon dioxide as a working fluid has been the subject of extensive studies in recent years, particularly in the field of refrigeration where it is at the heart of research to replace CFC and HCFC. Its ther... The use of carbon dioxide as a working fluid has been the subject of extensive studies in recent years, particularly in the field of refrigeration where it is at the heart of research to replace CFC and HCFC. Its thermodynamic properties make it a fluid of choice in the efficient use of energy at low and medium temperatures in engine cycles. However, the performance of transcritical CO2 cycles weakens under high temperature and pressure conditions, especially in refrigeration systems;On the other hand, this disadvantage becomes rather interesting in engine cycles where CO2 can be used as an alternative to the organic working fluid in small and medium-sized electrical systems for low quality or waste heat sources. In order to improve the performance of systems operating with CO2 in the field of refrigeration and electricity production, research has made it possible to develop several concepts, of which this article deals with a review of the state of the art, followed by analyzes in-depth and critical of the various developments to the most recent modifications in these fields. Detailed discussions on the performance and technical characteristics of the different evolutions are also highlighted as well as the factors affecting the overall performance of the systems studied. Finally, perspectives on the future development of the use of CO2 in these different cycles are presented. 展开更多
关键词 refrigeration cycle Power cycle System performance Transcritical CO2 cycles Working Fluid
下载PDF
Performance analysis of ammonia-water absorption/compression combined refrigeration cycle 被引量:1
3
作者 鲍帅阳 杜垲 +2 位作者 蔡星辰 牛晓峰 武云龙 《Journal of Southeast University(English Edition)》 EI CAS 2014年第1期60-67,共8页
In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis ... In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis and calculations on two combination ways by adding the compressor in the high-pressure area and in the low-pressure area are conducted respectively.The effects of several factors including the evaporation temperature Te heat-source temperature Th as well as the cooling water temperature Tw on the equivalent heat consumption in compression qCW heat consumption in absorption qG and the system coefficient of performance COP are analyzed under the two combination configurations.The results show that the effect of the equivalent heat consumption in compression on the COP is less than that of the heat consumption in absorption.Besides the compressor set in the high-pressure area uses more energy than that in the low-pressure area. Moreover the compressor in the low-pressure area is superior to that in the high-pressure area with respect to the COP. Under the given intermediate pressure there is an optimum heat-source temperature corresponding to the maximum COP of the AWA/CCR cycle. 展开更多
关键词 AMMONIA-WATER ABSORPTION compression refrigeration combined refrigeration cycle coefficient of performance COP
下载PDF
Performance of an irreversible quantum refrigeration cycle
4
作者 何济洲 欧阳微频 伍歆 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第1期53-59,共7页
A new model of a quantum refrigeration cycle composed of two adiabatic and two isomagnetic field processes is established. The working substance in the cycle consists of many non-interacting spin-1/2 systems. The perf... A new model of a quantum refrigeration cycle composed of two adiabatic and two isomagnetic field processes is established. The working substance in the cycle consists of many non-interacting spin-1/2 systems. The performance of the cycle is investigated, based on the quantum master equation and semi-group approach. The general expressions of several important performance parameters, such as the coefficient of performance, cooling rate, and power input, are given. It is found that the coefficient of performance of this cycle is in the closest analogy to that of the classical Carnot cycle. Furthermore, at high temperatures the optimal relations of the cooling rate and the maximum cooling rate are analysed in detail. Some performance characteristic curves of the cycle are plotted, such as the cooling rate versus the maximum ratio between high and low "temperatures" of the working substances, the maximum cooling rate versus the ratio between high and low "magnetic fields" and the "temperature" ratio between high and low reservoirs. The obtained results are further generalized and discussed, so that they may be directly applied to describing the performance of the quantum refrigerator using spin-J systems as the working substance. Finally, the optimum characteristics of the quantum Carnot and Ericsson refrigeration cycles are derived by analogy. 展开更多
关键词 spin systems quantum refrigeration cycle performance parameters
下载PDF
Performance comparison and analysis of a combined power and cooling system based on organic Rankine cycle 被引量:2
5
作者 王志奇 周奇遇 +2 位作者 夏小霞 刘斌 张欣 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第2期353-359,共7页
A novel power and cooling system combined system which coupled organic Rankine cycle(ORC) with vapor compression refrigeration cycle(VCRC) was proposed. R245 fa and butane were selected as the working fluid for the po... A novel power and cooling system combined system which coupled organic Rankine cycle(ORC) with vapor compression refrigeration cycle(VCRC) was proposed. R245 fa and butane were selected as the working fluid for the power and refrigeration cycle, respectively. A performance comparison and analysis for the combined system was presented. The results show that dual-pressure ORC-VCRC system can achieve an increase of 7.1% in thermal efficiency and 6.7% in exergy efficiency than that of basic ORC-VCRC. Intermediate pressure is a key parameter to both net power and exergy efficiency of dual-pressure ORC-VCRC system. Combined system can produce maximum net power and exergy efficiency at 0.85 MPa for intermediate pressure and 2.4 MPa for high pressure, respectively. However, superheated temperature at expander inlet has little impact on the two indicators. It can achieve higher overall COP, net power and exergy efficiency at smaller difference between condensation temperature and evaporation temperature of VCRC. 展开更多
关键词 dual-pressure organic Rankine cycle vapor compression refrigeration waste heat performance analysis
下载PDF
Refrigeration Performance Analysis and Its Applicability of a New Metal Hydride Couple in Auto Air-conditioning
6
作者 倪久建 陈江平 +3 位作者 陈芝久 覃峰 吕曼琪 杨柯 《Journal of Shanghai Jiaotong university(Science)》 EI 2005年第1期80-85,共6页
With COP and dynamic characteristics in refrigeration cycle as criteria,a new metal hydride couple——LaNi 4.61 Mn 0.26 Al 0.13 /La 0.6 Y 0.4 Ni 4.8 Mn 0.2 was selected by establishing calculation procedure and metal ... With COP and dynamic characteristics in refrigeration cycle as criteria,a new metal hydride couple——LaNi 4.61 Mn 0.26 Al 0.13 /La 0.6 Y 0.4 Ni 4.8 Mn 0.2 was selected by establishing calculation procedure and metal hydride selection model.The experimental results show that the refigeration cycle of the selected couple is good in the performance.The recovered waste heat and refrigeration power from exhaust gas of several kinds of automobile are calculated by waste-heat formula,coefficient R Q and COP.Refrigeration cycle of the new couple can satisfy the air-conditioning requirement of truck and car and is not enough in passenger car,according to the respective cooling load. 展开更多
关键词 metal hydried COUPLE refrigeration cycle coefficient of performance (COP)
下载PDF
Calculating the Refrigeration Coefficient by Using the Second Law of Thermodynamics
7
作者 杨洪海 尹世永 《Journal of Donghua University(English Edition)》 EI CAS 2007年第6期811-814,共4页
Refrigeration coefficient, ε, is usually calculated by using the First Law of Thermodynamics. In this paper, a new derivation process is introduced through the combination of the Second Law of Thermodynamics with the... Refrigeration coefficient, ε, is usually calculated by using the First Law of Thermodynamics. In this paper, a new derivation process is introduced through the combination of the Second Law of Thermodynamics with the First Law of Thermodynamics. As a result, two new calculation equations for refrigeration coefficient are proposed. One equation is equivalent to the common method, but its form is a little complicated for real calculation. Another equation is the further simplification, and can be used to calculate the refrigeration coefficient instead of common method with a oermit error. 展开更多
关键词 vapor-compression refrigeration cycle refrigeration coefficient Second Law of Thernxxlynamics refrigerANT
下载PDF
Experimental Evaluation of the Heat Output/Input and Coefficient of Performance Characteristics of a Chemical Heat Pump in the Periodic Operation of CaCl<sub>2</sub>Hydration
8
作者 Atsuhiro Ichinose Kazuki Kuwata +2 位作者 Takehiro Esaki Takayuki Matsuda Noriyuki Kobayashi 《Journal of Materials Science and Chemical Engineering》 2020年第11期33-42,共10页
We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the... We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the practicality from the experimental results. The reactor module employed was an aluminum plate-tube heat exchanger with corrugated fins, and the CaCl<sub>2</sub> powder was in the form of a packed bed. Heat storage operation and heat dissipation operation are performed at the same time and supplied to the heat demand destination. At this time, an environmental heat source can be used during the heat radiation operation, and the heat output can release more heat than the heat input during heat storage. The heat discharging and charging characteristics of the reactor module were evaluated experimentally. The coefficient of performance (COP) was calculated for the heat upgrading cycle, and the heat output in the system was determined. A COP of 1.42 and output of 650 W/L, based on the heat exchanger volume, were obtained using a 600 s change time for the heat pump. 展开更多
关键词 Chemical Heat Pump CaCl2/H2O Hydration Reaction Heat Pump cycle coefficient of performance
下载PDF
Performance optimization analysis of a thermoelectric refrigerator with two resonances 被引量:4
9
作者 罗小光 何济洲 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第3期110-114,共5页
Based on electron transport theory, the performance of kx and kr filtered thermoelectric refrigerators with two resonances are studied in this paper. The performance characteristic curves between the cooling rate and ... Based on electron transport theory, the performance of kx and kr filtered thermoelectric refrigerators with two resonances are studied in this paper. The performance characteristic curves between the cooling rate and the coefficient of performance are plotted by numerical calculation. It is shown that the maximum cooling rate of the thermoelectric refrigerator with two resonances increases but the maximum coefficient of performance decreases compared with those with one resonance. No matter which resonance mechanism is used (kx or kr filtered), the cooling rate and the performance coefficient of the kr filtered refrigerator are much better than those of the kx filtered one. 展开更多
关键词 thermoelectric refrigerator two resonances cooling rate coefficient of performance
下载PDF
Experimental Performance of Moderate and High Temperature Heat Pump Charged with Refrigerant Mixture BY-3 被引量:3
10
作者 陈成敏 张于峰 +4 位作者 邓娜 马洪亭 张彦所 马丽筠 胡晓微 《Transactions of Tianjin University》 EI CAS 2011年第5期386-390,共5页
Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe... Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained. 展开更多
关键词 moderate and high temperature heat pump refrigerant mixture SINGLE-STAGE compression heat pump system coefficient of performance
下载PDF
Experimental Performance of TJR02 as an Alternative Refrigerant to R22 in a Small-Scale Cold Storage
11
作者 马洪亭 宋肖的 +1 位作者 杨国利 张于峰 《Transactions of Tianjin University》 EI CAS 2012年第5期330-334,共5页
A refrigerant mixture TJR02 was developed and the comparison experiment was performed on a singlestage vapor compression refrigeration system originally designed for R22.Experimental results show that TJR02 can be dir... A refrigerant mixture TJR02 was developed and the comparison experiment was performed on a singlestage vapor compression refrigeration system originally designed for R22.Experimental results show that TJR02 can be directly used in the system without modifying the original system or changing lubricant.By replacing R22 with TJR02,cooling rate gets faster and at least 20% of energy is saved.The actual detection in the standard test-bed verifies the experimental results and indicates that the adoption of TJR02 leads to greater efficiency and wider application.And the lower the refrigeratory temperature is,the more obvious the energy saving effects will be. 展开更多
关键词 alternative refrigerant TJR02 energy saving refrigeration capacity coefficient of performance
下载PDF
Aqueous ammonia solution cooling absorption refrigeration driven by fishing boat diesel exhaust heat 被引量:5
12
作者 陈亚平 林陈敏 田莹 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期333-338,共6页
A solution cooling absorption(SCA)approach is proposed to modify the aqueous ammonia absorption refrigerat-ion cycle using the strong solution from the absorber to cool the forepart of the absorption in the cycle fo... A solution cooling absorption(SCA)approach is proposed to modify the aqueous ammonia absorption refrigerat-ion cycle using the strong solution from the absorber to cool the forepart of the absorption in the cycle for reclaiming some portion of absorption heat.As a consequence of raised temperature at the inlet,the strong solution partially boils at the outlet of the solution heat exchanger,and diminishes the thermal heat consumption of the heat source.The calculation results show that the coefficient of performance(COP)of this modified cycle is about 28.3% higher than that of the traditional cycle under typical conditions;while the required heat transfer area of the total heat exchangers of the cycle is somewhat less than that of the traditional one.The capacity of refrigeration with the new absorption cycle is more than doubled in contrast to the adsorption scheme with an identical configuration.It is sufficient to supply a fishing boat the chilling capacity for preservation of fishing products with the modified cycle chiller driven by its diesel engine exhaust. 展开更多
关键词 aqueous ammonia absorption refrigeration solution cooling absorption waste heat recovery heat and mass transfer coefficient of performance
下载PDF
The performance characteristics of an irreversible quantum Otto harmonic refrigeration cycle 被引量:14
13
作者 HE JiZhou HE Xian TANG Wei 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2009年第9期1317-1323,共7页
In this paper, an irreversible quantum Otto refrigeration cycle working with harmonic systems is established. Base on Heisenberg quantum master equation, the equations of motion for the set of harmonic systems thermod... In this paper, an irreversible quantum Otto refrigeration cycle working with harmonic systems is established. Base on Heisenberg quantum master equation, the equations of motion for the set of harmonic systems thermodynamic observables are derived. The simulated diagrams of the quantum Otto refrigeration cycle are plotted. The relationship between average power of friction, cooling rate, power input, and the time of adiabatic process is analyzed by using numerical calculation. Moreover, the influence of the heat conductance and the time of iso-frequency process on the performance of the cycle is discussed. 展开更多
关键词 HARMONIC systems IRREVERSIBLE QUANTUM refrigeration cycle QUANTUM FRICTION performance analysis
原文传递
Thermodynamic Comparison Analysis on CO_2 Transcritical Reverse Cycles with IHX or Expander 被引量:2
14
作者 管海清 马一太 +1 位作者 杨俊兰 李敏霞 《Transactions of Tianjin University》 EI CAS 2005年第2期110-114,共5页
To improve the coefficient of performance (COP) of CO2 transcritical reverse cycle and determine the most efficient cycle, comparison analysis on (single-and) two-stage CO2 transcritical cycles with internal heat ... To improve the coefficient of performance (COP) of CO2 transcritical reverse cycle and determine the most efficient cycle, comparison analysis on (single-and) two-stage CO2 transcritical cycles with internal heat exchanger (IHX) or expander is presented adopting the principle of thermodynamics. Results indicate that the COP of four cycles,namely single-stage compression with IHX (SI), single-stage compression with expander (SE), two-stage compression with IHX (TI) and two-stage compression with expander (TE), can be ranged as TE>SE>TI>SI. It presents that adopting an expander to recover expansion power is the primary method to improve the COP of CO2 transcritical reverse cycle if the efficiency of the expander is up to a certain value. Under supposed operating condition, where the outlet temperature of gas cooler is 35 ℃ and the evaporating temperature is 5 ℃, the COP of TE cycle is about 4200 higher than that of SI cycle when the expander efficiency is 0.6 and the degree of superheat of IHX is 15 ℃. Therefore TE cycle is the most recommendatory one and it is better to adopt TE in those high-cooling capacity systems because its technology cost will be higher. 展开更多
关键词 CO_2 transcritical reverse cycle internal heat exchanger EXPANDER coefficient of performance
下载PDF
Magnetic Field Enhancement in Ammonia-Water Absorption Refrigeration Systems
15
作者 Moradeyo K. Odunfa Richard O. Fagbenle +1 位作者 Olanrewaju M. Oyewola Olayinka S. Ohunakin 《Energy and Power Engineering》 2014年第4期54-68,共15页
Absorption enhancement has been considered as an effective way of improving coefficient of performance (COP) of refrigeration systems and magnetic enhancement is one of these methods. A model of magnetic field enhance... Absorption enhancement has been considered as an effective way of improving coefficient of performance (COP) of refrigeration systems and magnetic enhancement is one of these methods. A model of magnetic field enhancement in ammonia-water absorption systems is presented in this paper. A numerical model using finite difference scheme was developed based on the conservation equations and mass transport relationship. Macroscopic magnetic field force was introduced in the momentum equation. The model was validated using data obtained from the literature. Changes in the physical properties of ammonia solution while absorbing both in the direction of falling film and across its thickness were investigated. The magnetic field was found to have some positive effect on the ammonia-water falling film absorption. The results indicate that absorption performance enhancement increased with magnetic intensity. The COP of simple ammonia solution absorption refrigeration system increased by 1.9% and 3.6% for magnetic induction of 1.4 and 3.0 Tesla respectively. 展开更多
关键词 AMMONIA-WATER Absorption refrigeration Magnetic Field Force AMMONIA SOLUTION Concentration coefficient of performance Finite DIFFERENCE Scheme Numerical SOLUTION
下载PDF
Establishment of a Model for the Calculation of the COP of a Solar Adsorption Refrigerator
16
作者 Amadou Konfe Gilbert G. Nana +1 位作者 Salif Ouedraogo Sié Kam 《Smart Grid and Renewable Energy》 2023年第11期197-208,共12页
This paper deals with the evaluation of the Coefficient of Performance (COP) of solar adsorption refrigeration. In the literature, simulation models to predict the thermal behaviour and the coefficient of performance ... This paper deals with the evaluation of the Coefficient of Performance (COP) of solar adsorption refrigeration. In the literature, simulation models to predict the thermal behaviour and the coefficient of performance of these systems are uncommon. This is why we suggest a model to simulate the operation of the machine in a typical hot and dry climate of the city of Ouagadougou. The objective is to provide a model for calculating the COP from the measurement of the ambient temperature and the irradiation of a given site. Starting from mathematical modelling, a resolution and simulation were made with COMSOL software based on the Dubinin-Astakhov adsorption model, the heat transfer balance equations, and the Linear Driving Force (LDF) model to describe the thermal behaviour of the system. A one-week measurement sequence on the adsorption solar refrigerator at the Albert Schweitzer Ecological Centre (CEAS) validated the numerical results. The measurement shows that for the days with high sunshine, the temperature of the reaction medium reaches 110°C, and the pressure reaches 500 mbar. This leads to a production of cold that allows it to reach the temperature of -5°C at the evaporator. Under these conditions, the COP is worth 14%. These results are obtained both by numerical simulation using the COMSOL 5.1 software and after a measurement session on the solar refrigerator available to the CEAS. We obtained an experimental and theoretical coefficient of performance varying between 9% and 14% with a difference of between 0% and 3%. We conclude that our model is suitable to estimate the COP of any device based on its thermal properties, the ambient temperature and the irradiation of a given site. 展开更多
关键词 SOLAR refrigeration ADSORPTION coefficient of performance Modelling
下载PDF
混合工质电动汽车空调全生命周期气候性能分析
17
作者 周峰 田旭文 李红旗 《汽车工程》 EI CSCD 北大核心 2024年第9期1707-1714,共8页
空调作为整车系统中环境调控的关键子系统,其全生命周期的碳排放对于电动汽车的环保和排放要求至关重要。本文结合汽车空调系统全生命周期气候性能LCCP模型及相关数据,对全国各省份电动汽车空调系统的LCCP情况进行分析,同时对两种不同... 空调作为整车系统中环境调控的关键子系统,其全生命周期的碳排放对于电动汽车的环保和排放要求至关重要。本文结合汽车空调系统全生命周期气候性能LCCP模型及相关数据,对全国各省份电动汽车空调系统的LCCP情况进行分析,同时对两种不同制热方案以及不同电力碳强度下的LCCP进行了比较分析。结果表明,RE170/R134a低GWP混合工质(二甲醚与R134a质量分数比90∶10)替换后电动汽车空调LCCP值降低了11.2%~28.1%,而采用热泵替换PTC电加热器后电动汽车空调LCCP值降低了0~33.1%,此外,随着未来我国电力碳强度与电动汽车保有量的变化,至2035年单辆车的LCCP值将会下降31.7%~39.3%,而全国整体电动汽车LCCP值将大幅上升。 展开更多
关键词 低GWP混合工质 全生命周期气候性能 空调系统 电动汽车
下载PDF
Coefficient of Performance at Maximum χ-Criterion for Feynman Ratchet as a Refrigerator
18
作者 盛世奇 杨盼 涂展春 《Communications in Theoretical Physics》 SCIE CAS CSCD 2014年第10期589-595,共7页
The χ-criterion is defined as the product of the energy conversion efficiency and the heat absorbed per unit time by the working substance [de Tom′as et al., Phys. Rev. E 85(2012) 010104(R)]. The χ-criterion for Fe... The χ-criterion is defined as the product of the energy conversion efficiency and the heat absorbed per unit time by the working substance [de Tom′as et al., Phys. Rev. E 85(2012) 010104(R)]. The χ-criterion for Feynman ratchet as a refrigerator operating between two heat baths is optimized. Asymptotic solutions of the coefficient of performance at maximum χ-criterion for Feynman ratchet are investigated at both large and small temperature difference. An interpolation formula, which fits the numerical solution very well, is proposed. Besides, the sufficient condition for the universality of the coefficient of performance at maximum χ is investigated. 展开更多
关键词 FEYNMAN RATCHET refrigerATOR coefficient of performance χ-criterion UNIVERSAL COP
原文传递
基于不同流动时间占比的紧凑式室温磁制冷系统实验研究
19
作者 李瑞 沈俊 +5 位作者 张志鹏 李振兴 莫兆军 高新强 海鹏 付琪 《物理学报》 SCIE EI CAS CSCD 北大核心 2024年第3期243-249,共7页
磁制冷因高效、环保、结构简单等特点,正有望成为替代传统蒸气制冷的新型室温制冷技术之一.当前针对单一影响因子对磁制冷样机的影响作用规律研究较为丰富,但对磁场-流场时序中流动时间占比工况的研究较少,且影响规律尚不明晰.本文以前... 磁制冷因高效、环保、结构简单等特点,正有望成为替代传统蒸气制冷的新型室温制冷技术之一.当前针对单一影响因子对磁制冷样机的影响作用规律研究较为丰富,但对磁场-流场时序中流动时间占比工况的研究较少,且影响规律尚不明晰.本文以前期研制的紧凑型室温磁制冷系统为基础,在固定的磁场时序情况下开展不同流动时间占比的实验研究,探索制冷温跨、制冷量、压降及性能系数与流动时间占比之间的关联.以磁场时序1:4:1:4与频率0.45 Hz的工况为例,开展了固定磁场时序的不同流动时间占比(100%,80%,60%)的实验研究.结果表明:1)小利用系数和高流动时间的组合可获得较大温跨,大利用系数和高流动时间占比的组合可获得较大冷量,其中当利用系数为0.42、流动时间占比为100%时,获得最大无负荷制冷温跨26.2 K;2)对比研究了利用系数与流动时间占比对回热器压降及性能系数的影响,流动时间占比的增大和利用系数的减小均会造成流体速度的减小,会使压降进一步减小,性能系数进一步增大.本研究阐明了制冷温跨、制冷量、压降及性能系数与流动时间占比之间的影响规律,为进一步提升室温磁制冷机的性能奠定基础. 展开更多
关键词 流动时间占比 制冷温跨 制冷量 性能系数
下载PDF
采用非共沸制冷剂的双喷气增焓两级压缩热泵循环研究 被引量:1
20
作者 杨锘 唐运通 +3 位作者 陈健勇 陈颖 罗向龙 何嘉诚 《制冷与空调》 2024年第4期67-72,79,共7页
提出一种采用非共沸制冷剂的双喷气增焓两级压缩热泵循环(DVIC),该循环在普通喷气增焓循环(VIC)的基础上采用分液冷凝技术,并增加一组闪蒸器,减少系统不可逆损失,改善热力性能。采用R290/R1336mzz(Z)非共沸制冷剂,对DVIC进行研究,并与VI... 提出一种采用非共沸制冷剂的双喷气增焓两级压缩热泵循环(DVIC),该循环在普通喷气增焓循环(VIC)的基础上采用分液冷凝技术,并增加一组闪蒸器,减少系统不可逆损失,改善热力性能。采用R290/R1336mzz(Z)非共沸制冷剂,对DVIC进行研究,并与VIC进行比较。结果表明:在设定工况下,DVIC比VIC拥有更优的循环性能,系统COP和(火用)效率分别提高5.82%和8.41%,压缩机功耗降低6.39%;在较低蒸发温度或较高冷凝温度的运行工况下,DVIC性能的改善效果更加明显。 展开更多
关键词 热泵 非共沸制冷剂 喷气增焓 分液冷凝 性能系数 (火用)损
下载PDF
上一页 1 2 22 下一页 到第
使用帮助 返回顶部