期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
ANGULAR DISTORTION ALLOWABLE VALUE AND ASSESS METHOD OF WELD ON COKE TOWER 被引量:1
1
作者 CHEN Sunyi 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第6期13-17,共5页
A graph as the new engineering method for estimate the safety of bulging deformation of coke tower is proposed. Through stresses analysis of circumferential weld of coke tower and comparing the stresses produced by pr... A graph as the new engineering method for estimate the safety of bulging deformation of coke tower is proposed. Through stresses analysis of circumferential weld of coke tower and comparing the stresses produced by pressure with heat stress of steady state, residual stress, bending stress produced by both itself weight and wind loads, it showed that the stresses produced by pressure on the angle distortion are the main factor of equivalent stress of the combined stress. After comparing four kinds of stress controlling conditions, the relation to stress with depth of angular distortion, grade of curvature of angular distortion and half of region of angular distortion has been inferred. Graph of deformation allowable value of coke tower for different condition by angular distortion and half of region of angular distortion has been plotted. The five steps for its engineering use have been explained. The lighter the grade of curvature is, the larger of bulge allowance, may be, and the bigger of depth of angular distortion may pose too. For the coke tower with a popular structure of Dg 5 400 mmx28 mm, the result by graph is nearly more than the result of two formulas formed by other research, the error is less than 7.0%. But, the graph can be easily applied to different size of angular distortion. 展开更多
关键词 Coke tower Bulging deformation Angular distortion Allowable limit
下载PDF
The Transient Modal Dynamic Analysis of a Coke Tower
2
作者 XIE Teng-teng SUN Tie XING Ling ZHANG Su-xiang 《International Journal of Plant Engineering and Management》 2012年第3期187-192,共6页
Dynamic analysis must be performed when the duration of the applied load is short or if the load is dynamic in nature. Wind load, as a random load, can lead to the vibration of the coke tower. In order to study the in... Dynamic analysis must be performed when the duration of the applied load is short or if the load is dynamic in nature. Wind load, as a random load, can lead to the vibration of the coke tower. In order to study the influence to the strength of the coke tower by wind, ABAQUS was used to conduct the transient modal dynamic analysis of the wind load. The response of the structure during loading and unloading was mainly observed. The results indicate that, with the effect of wind, the maximal nodal displacement appears at the top of the tower, which is 0.79 mm; while the maximal stress locates at the node around the skirt, the maximum is 3.26 MPa. Both of the displacement and stress cannot cause the failure of the structure. After loading and unloading, the structure engenders vibration along the loading direction. The frequency is 10 Hz, under the effect of external loads, it may easily cause the resonance of the structure, which can cause damage to the structure. So it must be taken into consideration during the process of design and operation. 展开更多
关键词 wind load coke tower dynamic analysis VIBRATION RESONANCE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部