The conventional solar heating floor system contains a big water tank to store energy in the day time for heating at night,which takes much building space and is very heavy.In order to reduce the water tank volume eve...The conventional solar heating floor system contains a big water tank to store energy in the day time for heating at night,which takes much building space and is very heavy.In order to reduce the water tank volume even to cancel the tank,a novel structure of integrated water pipe floor heating system using shape-stabilized phase change materials(SSPCM)for thermal energy storage was developed.A numerical model was developed to analyze the performance of SSPCM floor heating system under the intermittent heating condition,which was verified by our experimental data.The thermal performance of the heating system and the effects of various factors on it were analyzed numerically.The factors including phase transition temperature,heat of fusion,thermal conductivity of SSPCM and thermal conductivity of the decoration material were analyzed.The results show that tm and kd are the most import influencing factors on the thermal performance of SSPCM floor heating system,since they determine the heat source temperature and thermal resistance between SSPCM plates and indoor air,respectively.Hm should be large to store enough thermal energy in the day time for nighttimes heating.The effects of kp can be ignored in this system.The SSPCM floor heating system has potential of making use of the daytime solar energy for heating at night efficiently in various climates when its structure is properly designed.展开更多
To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho...To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.展开更多
This study evaluates the effectiveness of phase change materials(PCMs) inside a storage tank of warm water for solar water heating(SWH) system through the theoretical simulation based on the experimental model of S.Ca...This study evaluates the effectiveness of phase change materials(PCMs) inside a storage tank of warm water for solar water heating(SWH) system through the theoretical simulation based on the experimental model of S.Canbazoglu et al.The model is explained by five fundamental equations for the calculation of various parameters like the effectiveness of PCMs,the mass of hot water,total heat content,and duration of charging.This study simulated eleven PCMs to analyze their effectiveness like Sodium hydrogen phosphate dodecahydrate(SHPD),OM 37,N-Eicosane(NE),Lauric acid(LA),Paraffin wax(PW),OM 48,Paraffin wax C_(20-33)(PW-C20-33),Sodium acetate trihydrate(SAT),Palmitic acid(PA),Myristic acid(MA),and Stearic acid(SA).Among all PCMs,the SHPD has found the highest value of effectiveness factor of 3.27.So,it is the most recommended PCM for the storage tank of the SWH system.The study also includes the melt fraction analysis of all enumerated PCMs corresponding to container materials of stainless steel,glass,aluminum mixed,tin,aluminum,and copper.This melt fraction analysis is performed by making a coding program in the FORTRAN programming language.Through the analysis,copper container material is found to have high melting rate for all PCMs so it is superior to other container materials.展开更多
In this study,experimental and numerical investigations were conducted on a tube-fin heat-exchanger latent-heat cold energy storage unit.The fin side of the heat exchanger was filled with water as the energy storage m...In this study,experimental and numerical investigations were conducted on a tube-fin heat-exchanger latent-heat cold energy storage unit.The fin side of the heat exchanger was filled with water as the energy storage medium,and modified expanded graphite(MEG)was employed to improve the thermal characteristics of water.The water contact angle of the expanded graphite decreased from 106.31°to 0°,and the hydrophilicity and the absorption rate of water significantly improved after the modification.Moreover,the experimental analyses of the charge/discharge process showed that the cooling capacity of the system filled with 90 wt.%water/MEG was 80.8%of that of pure water,whereas its cooling time was only 69.7%of that of pure water.The average power increased by 15.9%compared with that of water.The system filled with 90 wt.%water/MEG completed two energy charging and discharging cycles,whereas the system filled with water completed only 1.5 cycles within 15000 s.Furthermore,the effects of the flow rate and inlet temperature of the heat transfer fluid on the charging process were explored.Finally,a numerical model was built and validated to investigate the phase change behavior and the effect of the structure size on the performance of the system.The heat-exchanger fin spacing had no significant effect on the cold energy storage unit,whereas the vertical spacing of the tube pass had the highest effect.It can be concluded that the heat exchanger combined with high-thermal-conductivity water/MEG exhibits better energy storage capacity and working power,showing a wide application prospect in the field of cold energy storage.展开更多
基金Supported by National 11th Five-Year Plan of Dept.of Science,China(2006BAA04B02,2006BAJ02A09)
文摘The conventional solar heating floor system contains a big water tank to store energy in the day time for heating at night,which takes much building space and is very heavy.In order to reduce the water tank volume even to cancel the tank,a novel structure of integrated water pipe floor heating system using shape-stabilized phase change materials(SSPCM)for thermal energy storage was developed.A numerical model was developed to analyze the performance of SSPCM floor heating system under the intermittent heating condition,which was verified by our experimental data.The thermal performance of the heating system and the effects of various factors on it were analyzed numerically.The factors including phase transition temperature,heat of fusion,thermal conductivity of SSPCM and thermal conductivity of the decoration material were analyzed.The results show that tm and kd are the most import influencing factors on the thermal performance of SSPCM floor heating system,since they determine the heat source temperature and thermal resistance between SSPCM plates and indoor air,respectively.Hm should be large to store enough thermal energy in the day time for nighttimes heating.The effects of kp can be ignored in this system.The SSPCM floor heating system has potential of making use of the daytime solar energy for heating at night efficiently in various climates when its structure is properly designed.
基金Project(50606007) supported by the National Natural Science Foundation of China
文摘To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.
基金the University Grants Commission (UGC) & Ministry of Human Resource Development (MHRD),Government of India,New Delhi for providing the Junior Research Fellowship (JRF)the Council of Science and Technology,UP (Reference No, CST 3012-dt.26-12-2016) for providing research grants to carry out the work at the institute。
文摘This study evaluates the effectiveness of phase change materials(PCMs) inside a storage tank of warm water for solar water heating(SWH) system through the theoretical simulation based on the experimental model of S.Canbazoglu et al.The model is explained by five fundamental equations for the calculation of various parameters like the effectiveness of PCMs,the mass of hot water,total heat content,and duration of charging.This study simulated eleven PCMs to analyze their effectiveness like Sodium hydrogen phosphate dodecahydrate(SHPD),OM 37,N-Eicosane(NE),Lauric acid(LA),Paraffin wax(PW),OM 48,Paraffin wax C_(20-33)(PW-C20-33),Sodium acetate trihydrate(SAT),Palmitic acid(PA),Myristic acid(MA),and Stearic acid(SA).Among all PCMs,the SHPD has found the highest value of effectiveness factor of 3.27.So,it is the most recommended PCM for the storage tank of the SWH system.The study also includes the melt fraction analysis of all enumerated PCMs corresponding to container materials of stainless steel,glass,aluminum mixed,tin,aluminum,and copper.This melt fraction analysis is performed by making a coding program in the FORTRAN programming language.Through the analysis,copper container material is found to have high melting rate for all PCMs so it is superior to other container materials.
基金National Key R&D Program of China(Grant No.:2020YFA0210704).
文摘In this study,experimental and numerical investigations were conducted on a tube-fin heat-exchanger latent-heat cold energy storage unit.The fin side of the heat exchanger was filled with water as the energy storage medium,and modified expanded graphite(MEG)was employed to improve the thermal characteristics of water.The water contact angle of the expanded graphite decreased from 106.31°to 0°,and the hydrophilicity and the absorption rate of water significantly improved after the modification.Moreover,the experimental analyses of the charge/discharge process showed that the cooling capacity of the system filled with 90 wt.%water/MEG was 80.8%of that of pure water,whereas its cooling time was only 69.7%of that of pure water.The average power increased by 15.9%compared with that of water.The system filled with 90 wt.%water/MEG completed two energy charging and discharging cycles,whereas the system filled with water completed only 1.5 cycles within 15000 s.Furthermore,the effects of the flow rate and inlet temperature of the heat transfer fluid on the charging process were explored.Finally,a numerical model was built and validated to investigate the phase change behavior and the effect of the structure size on the performance of the system.The heat-exchanger fin spacing had no significant effect on the cold energy storage unit,whereas the vertical spacing of the tube pass had the highest effect.It can be concluded that the heat exchanger combined with high-thermal-conductivity water/MEG exhibits better energy storage capacity and working power,showing a wide application prospect in the field of cold energy storage.