Experimental and numerical study regarding H-steel all-bolted connection steel frame with composite wall boards
1
作者 Fan Min Guo Hongchao +2 位作者 Li Shen Wang Zhenshan Wang Huaqiang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期427-443,共17页
H-steel all-bolted connection steel frame structures with heat preservation and decoration composite wall boards were investigated and the seismic performances of three scaled specimens were studied.The failure modes,... H-steel all-bolted connection steel frame structures with heat preservation and decoration composite wall boards were investigated and the seismic performances of three scaled specimens were studied.The failure modes,hysteresis curves,bearing capacity,ductility,energy dissipation capacity,stiffness degradation and strain distribution were discussed.The calculation method of structural theoretical internal force was presented.The results showed that the overall structural seismic performance was better,and the structural ductility met the demands of elastic-plastic inter-story drift angle for seismic design.The H-steel weak-axis connection structure obtained better energy dissipation capacity,and its bearing capacity and stiffness were slightly different from the strong-axis connection.The heat preservation and decoration performance of composite wallboard and the all-bolted connection of the steel frame realized prefabrication during the whole construction period.The plastic hinge of the steel beam can be moved outwards because of the L-angles,which effectively avoids stress concentration in joint areas and expands the plastic hinge range.The errors between the theoretical structural capacity calculated by the plastic analysis method and the test results were within 2.44%.In addition,structural failure mechanisms and bearing capacities were verified by the finite element(FE)analysis,and the effects of the main parameters on the structures were investigated.The FE verification results were the same as in the test.The research results provide theoretical support and technical guidance for the application of thermal insulation and decorative composite wall panels in H-shaped steel all-bolted steel frames. 展开更多
关键词 composite wall boards all-bolted steel frame H-steel low-cyclic loading failure modes
下载PDF
An effective simplified model of composite compression struts for partially-restrained steel frame with reinforced concrete infill walls 被引量:2
2
作者 Sun Guohua Chuang-Sheng Walter Yang +1 位作者 Gu Qiang Reginald DesRoches 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第2期403-415,共13页
To resolve the issue regarding inaccurate prediction of the hysteretic behavior by micro-based numerical analysis for partially-restrained(PR)steel frames with solid reinforced concrete(RC)infill walls,an innovati... To resolve the issue regarding inaccurate prediction of the hysteretic behavior by micro-based numerical analysis for partially-restrained(PR)steel frames with solid reinforced concrete(RC)infill walls,an innovative simplified model of composite compression struts is proposed on the basis of experimental observation on the cracking distribution,load transferring mechanism,and failure modes of RC infill walls filled in PR steel frame.The proposed composite compression struts model for the solid RC infill walls is composed ofαinclined struts and main diagonal struts.Theαinclined struts are used to reflect the part of the lateral force resisted by shear connectors along the frame-wall interface,while the main diagonal struts are introduced to take into account the rest of the lateral force transferred along the diagonal direction due to the complicated interaction between the steel frame and RC infill walls.This study derives appropriate formulas for the effective widths of theαinclined strut and main diagonal strut,respectively.An example of PR steel frame with RC infill walls simulating simulated by the composite inclined compression struts model is illustrated.The maximum lateral strength and the hysteresis curve shape obtained from the proposed composite strut model are in good agreement with those from the test results,and the backbone curve of a PR steel frame with RC infill walls can be predicted precisely when the inter-story drift is within 1%.This simplified model can also predict the structural stiffness and the equivalent viscous damping ratio well when the inter-story drift ratio exceeds 0.5%. 展开更多
关键词 PR connection steel frame infill walls shear connector hysteretic behavior STRUT
下载PDF
Evaluation of the Performance of Galvanized Steel Support in Construction of Living Wall Systems
3
作者 Fernando B. Mainier Maria Alejandra Rico Pérez +1 位作者 Leandro V. Pontual Ana Lucia Torres Seroa da Motta 《Open Journal of Civil Engineering》 2016年第4期566-576,共11页
Currently, Living Wall Systems (LWSs) are assuming great importance in the built environment, due to environmental and aesthetic advantages, as well as the use of urban residual space and underutilized surfaces of bui... Currently, Living Wall Systems (LWSs) are assuming great importance in the built environment, due to environmental and aesthetic advantages, as well as the use of urban residual space and underutilized surfaces of buildings. However, the maintenance and the durability of the materials used have been a challenge for architects and professionals in the field. The aim of this paper is to evaluate the anti-corrosion performance of a steel framing profile, galvanized carbon steel (55% Al-Zn), a sustainable material with easy assembly, to apply LWS in the hot and humid tropical climate of Niterói (Rio de Janeiro, Brazil). In order to create the conditions of the tests, “X” cut were made in Al-Zn coating, sanding, and application of epoxy and glass fiber-reinforced polyester. After the experiments that lasted four months, the 55% Al-Zn coating was analyzed using Scanning Electron Microscope (SEM) and energy dispersive X-ray spectroscopy (EDS). The results of the tests were promising for the use of this galvanized steel for application as a support for green vertical facades. 55% Al-Zn coatings are recommended for marine atmospheres due to their good anti-corrosion performance. 展开更多
关键词 Living wall System (LWS) 55% Al-Zn Coating steel framing Galvanized steel CORROSION
下载PDF
高烈度地区体育馆类公共建筑结构设计探讨
4
作者 王烨妮 王固琴 《山西建筑》 2025年第1期51-54,共4页
风雨操场作为体育馆类公共建筑,通常造型独特且体型复杂;而作为乙类建筑,存在大跨度、水平和竖向刚度分布不均等结构分析中较难处理的问题,因此其计算分析较为严格,而宁夏银川作为8度区,其抗震要求则更为严格且计算分析亦更为复杂。以... 风雨操场作为体育馆类公共建筑,通常造型独特且体型复杂;而作为乙类建筑,存在大跨度、水平和竖向刚度分布不均等结构分析中较难处理的问题,因此其计算分析较为严格,而宁夏银川作为8度区,其抗震要求则更为严格且计算分析亦更为复杂。以银川一中风雨操场为例,对体育馆类结构中存在的问题及其处理方法进行了分析和探讨,为同类建筑的结构设计提供参考。 展开更多
关键词 风雨操场 体育馆 大跨度 斜柱 轻钢龙骨金属网墙体 网架屋面 钢骨架轻型板屋面
下载PDF
Numerical modeling of external light gauge steel framed wall systems exposed to bushfire flame zone conditions
5
作者 Sahani HENDAWITHARANA Anthony ARIYANAYAGAM Mahen MAHENDRAN 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2024年第9期1424-1444,共21页
Bushfire-related building losses cause adverse economic impacts to countries prone to bushfires.Building materials and components play a vital role in reducing these impacts.However,due to high costs of experimental s... Bushfire-related building losses cause adverse economic impacts to countries prone to bushfires.Building materials and components play a vital role in reducing these impacts.However,due to high costs of experimental studies and lack of numerical studies,the heat transfer behavior of building’s external components in bushfire-prone areas has not been adequately investigated.Often large-scale heat transfer models are developed using Computational Fluid Dynamics(CFD)tools,and the availability of CFD models for heat transfer in building components improves the understanding of the behavior of systems and systems of systems.Therefore,this paper uses a numerical modeling approach to investigate the bushfire/wildfire resistance of external Light gauge Steel Framed(LSF)wall systems.Both full-scale and small-scale heat transfer models were developed for the LSF wall systems.Experimental results of six internal and external LSF wall systems with varying plasterboard thickness and cladding material were used to validate the developed models.The study was then extended to investigate the bushfire resistance of seven external wall systems under two different bushfire flame zone conditions.The results illustrate the significant effects of fire curves,LSF wall components and configuration on the heat transfer across the walls.They have shown 1)the favorable performance of steel cladding and Autoclaved Aerated Concrete(AAC)panels when used on the external side of wall systems and 2)the adequacy of thin-walled steel studs’load-bearing capacity during bushfire exposures.This study has shown that most of the investigated external LSF walls could be reused with cost-effective retrofitting such as replacing the Fire Side(FS)steel cladding after bushfire exposures.Overall,this study has advanced the understanding of the behavior of external light steel framed walls under bushfire flame zone conditions. 展开更多
关键词 bushfires flame zone external light gauge steel framed walls heat transfer analyses numerical models
原文传递
Seismic behavior and mechanism analysis of innovative precast shear wall involving vertical joints 被引量:3
6
作者 孙建 邱洪兴 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第4期1536-1547,共12页
To study the seismic performance and load-transferring mechanism of an innovative precast shear wall(IPSW) involving vertical joints, an experimental investigation and theoretical analysis were successively conducted ... To study the seismic performance and load-transferring mechanism of an innovative precast shear wall(IPSW) involving vertical joints, an experimental investigation and theoretical analysis were successively conducted on two test walls. The test results confirm the feasibility of the novel joints as well as the favorable seismic performance of the walls, even though certain optimization measures should be taken to improve the ductility. The load-transferring mechanism subsequently is theoretically investigated based on the experimental study. The theoretical results show the load-transferring route of the novel joints is concise and definite. During the elastic stage, the vertical shear stress in the connecting steel frame(CSF) distributes uniformly; and each high-strength bolt(HSB)primarily delivers vertical shear force. However, the stress in the CSF redistributes when the walls develop into the elastic-plastic stage. At the ultimate state, the vertical shear stress and horizontal normal stress in the CSF distribute linearly; and the HSBs at both ends of the CSF transfer the maximum shear forces. 展开更多
关键词 precast shear wall vertical joint seismic behavior high-strength bolt connecting steel frame
下载PDF
Development of realistic design fire time-temperature :urves for the testing of cold-formed steel wall systems 被引量:1
7
作者 Anthony Deloge ARIYANAYAGAM Mahen MAHENDRAN 《Frontiers of Structural and Civil Engineering》 CSCD 2014年第4期427-447,共21页
Fire resistance rating of light gauge steel frame (LSF) wall systems is obtained from fire tests based on the standard fire time-temperature curve. However, fire severity has increased in modem buildings due to high... Fire resistance rating of light gauge steel frame (LSF) wall systems is obtained from fire tests based on the standard fire time-temperature curve. However, fire severity has increased in modem buildings due to higher fuel loads as a result of modern furniture and light weight constructions that make use of thermoplastics materials, synthetic foams and fabrics. Some of these materials are high in calorific values and increase both the spread of fire growth and heat release rate, thus increasing the fire severity beyond that of the standard fire curve. Further, the standard fire curve does not include a decay phase that is present in natural fires. Despite the increasing usage of LSF walls, their behavior in real building fires is not fully understood. This paper presents the details of a research study aimed at developing realistic design fire curves for use in the fire tests of LSF walls. It includes a review of the characteristics of building fires, previously developed fire time-temperature curves, computer models and available parametric equations. The paper highlights that real building fire time-temperature curves depend on the fuel load representing the combustible building contents, ventilation openings and thermal properties of wall lining materials, and provides suitable values of many required parameters including fuel loads in residential buildings. Finally, realistic design fire time-temperature curves simulating the fire conditions in modem residential buildings are proposed for the testing of LSF walls. 展开更多
关键词 fire safety standard fire curve realistic design fire time-temperature curves light gauge steel frame (LSF) walls fuel load fire resistance rating
原文传递
钢管混凝土键连接框架梁和剪力墙的受剪性能 被引量:1
8
作者 李明 刘栩邑 +2 位作者 吴潜 吴欣禹 吴永新 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2024年第1期38-46,共9页
目的 研究钢管混凝土键连接框架梁和剪力墙的受剪性能,为工程应用提供设计依据。方法 应用有限元分析软件ABAQUS对比钢管混凝土键连接与现浇连接梁墙的结构受剪性能,分析前者受剪机理及不同因素对受剪性能的影响。结果 钢管混凝土键连... 目的 研究钢管混凝土键连接框架梁和剪力墙的受剪性能,为工程应用提供设计依据。方法 应用有限元分析软件ABAQUS对比钢管混凝土键连接与现浇连接梁墙的结构受剪性能,分析前者受剪机理及不同因素对受剪性能的影响。结果 钢管混凝土键连接梁墙的结构承载力和延性系数较现浇结构分别提高约10%和34%;钢材强度从Q235到Q390,初始刚度增加8.44%;截面高度从100 mm到120 mm,延性系数提高17.73%;截面厚度每增加2 mm,承载力提高约15%;截面长度和混凝土强度等级对承载力、初始刚度和延性系数的影响均小于15%,纵向距离对其受剪性能几乎无影响。结论 采用钢管混凝土键连接梁墙的结构总体受剪性能优于现浇结构;钢材强度和截面厚度分别是影响初始刚度和承载力的主要因素。 展开更多
关键词 钢管混凝土键 框架-剪力墙结构 梁墙试件 抗剪性能 有限元分析
下载PDF
装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能 被引量:6
9
作者 曹万林 杨兆源 《北京工业大学学报》 CAS CSCD 北大核心 2024年第2期165-179,共15页
为研究装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能,对1个足尺轻钢框架结构试件和3个足尺轻钢框架-轻钢骨架轻混凝土墙板结构试件进行了低周反复荷载下的抗震性能试验及理论分析,试件变量包括:2种装配构造,即内嵌式装配墙板、外... 为研究装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能,对1个足尺轻钢框架结构试件和3个足尺轻钢框架-轻钢骨架轻混凝土墙板结构试件进行了低周反复荷载下的抗震性能试验及理论分析,试件变量包括:2种装配构造,即内嵌式装配墙板、外贴式装配墙板;2种轻钢骨架轻混凝土墙板,即框架式轻钢骨架轻混凝土墙板、桁架式轻钢骨架轻混凝土墙板。研究了各试件的破坏特征和损伤演化过程,分析了结构滞回特性、承载力、变形能力、刚度退化、耗能性能和应变。结果表明:装配式轻钢框架-轻钢骨架轻混凝土墙板结构共同工作性能良好,其水平承载力相比轻钢框架提高了204.7%~210.4%,抗侧刚度提高了257.3%~512.5%,结构变形及耗能能力有显著提高;内嵌墙板的自攻钉连接构造以及外贴墙板的螺栓连接构造传力性能可靠,结构具备2道抗震防线的受力特征;基于简化塑性分析模型以及拉压杆软化桁架模型,对试件承载力进行了计算,计算结果与试验符合较好。 展开更多
关键词 装配式组合结构 轻钢框架 轻钢骨架轻混凝土墙板 抗震性能 低周反复荷载试验 承载力计算
下载PDF
外附轻质墙板的弱轴全螺栓装配式钢框架试验研究
10
作者 韦俊 樊敏 +3 位作者 王洪臣 郭宏超 李慎 王振山 《应用力学学报》 CAS CSCD 北大核心 2024年第6期1378-1384,共7页
为实现钢框架H型钢柱的弱轴连接,设计了一种悬臂段H型钢梁柱的弱轴顶底L型件连接钢框架,并将保温装饰轻质墙板作为围护结构外挂于钢框架。对1榀单层单跨1∶2缩尺试件进行抗震试验研究,分析结构体系的整体破坏模式、承载力、刚度以及耗... 为实现钢框架H型钢柱的弱轴连接,设计了一种悬臂段H型钢梁柱的弱轴顶底L型件连接钢框架,并将保温装饰轻质墙板作为围护结构外挂于钢框架。对1榀单层单跨1∶2缩尺试件进行抗震试验研究,分析结构体系的整体破坏模式、承载力、刚度以及耗能能力的变化,评价外挂轻质墙板体系的整体性能。结果表明:外挂轻质墙板全螺栓装配式弱轴连接钢框架的破坏模式合理,墙板体系稳定,L型件连接节点实现了梁端塑性铰外移。结构滞回曲线饱满,骨架曲线呈S型,正向屈服位移与极限承载力分别为27.08 mm与351.99 kN,负向为19.78 mm和377.43 kN,满足结构延性与承载力需求;试件塑性刚度退化缓慢,最大阻尼比达0.35,整体耗能性能较好。外挂墙板的干挂形式与钢框架的全螺栓连接方法共同提高了建筑装配化效率。 展开更多
关键词 钢框架 弱轴连接 轻质墙板 循环加载 抗震性能
下载PDF
柱脚不同连接形式钢框架-摇摆墙结构抗震性能对比分析
11
作者 蔡新江 陈磊 +2 位作者 毛小勇 田石柱 王文晋 《防灾减灾工程学报》 CSCD 北大核心 2024年第5期1062-1071,共10页
增设摇摆墙后框架结构地震下柱脚仍会发生一定程度的塑性损伤,将柱脚设置为铰接或提离后有望减轻上述缺陷。以三层、六层和九层钢框架为基准模型,分别建立柱脚固接、铰接及提离三种框架-摇摆墙结构模型并进行动力弹塑性时程分析,对比各... 增设摇摆墙后框架结构地震下柱脚仍会发生一定程度的塑性损伤,将柱脚设置为铰接或提离后有望减轻上述缺陷。以三层、六层和九层钢框架为基准模型,分别建立柱脚固接、铰接及提离三种框架-摇摆墙结构模型并进行动力弹塑性时程分析,对比各结构最大侧向位移、层间位移角、峰值加速度、层间剪力、墙体剪力和弯矩等;进一步建立耗能连梁固接和铰接的对比模型,研究连梁连接方式对结构抗震性能的影响。结果表明:三层模型中柱脚固接时侧向位移、层间位移角、加速度、层间剪力及摇摆墙墙体剪力的控制效果最优,六层、九层模型中分别对应柱脚提离和柱脚铰接效果最好;摇摆墙墙体剪力图和弯矩图分别呈现“C形”和“反C形”,柱脚固接时墙体弯矩均为最小,与层数无关。柱脚固接耗能连梁两端采用固接最优,柱脚铰接和柱脚提离时耗能连梁两端采用铰接形式效果更优。此分析可为框架-摇摆墙结构进一步推广应用提供参考。 展开更多
关键词 钢框架-摇摆墙 柱脚形式 变形 加速度 内力 连接形式
下载PDF
木结构墙体空气声隔声性能
12
作者 岳孔 程相宇 +3 位作者 张玉才 吴鹏 石鑫磊 郭华瑜 《林业科学》 EI CAS CSCD 北大核心 2024年第10期104-115,共12页
【目的】研究全频段范围内木结构墙体空气声隔声性能,明确限制常规构造木骨架墙体隔声性能的瓶颈,揭示设置隔声垫层、改变骨架类型、设置窗体等设计参数对墙体隔声性能的影响规律,提出高空气声隔声等级的木结构墙体体系,为木结构墙体在... 【目的】研究全频段范围内木结构墙体空气声隔声性能,明确限制常规构造木骨架墙体隔声性能的瓶颈,揭示设置隔声垫层、改变骨架类型、设置窗体等设计参数对墙体隔声性能的影响规律,提出高空气声隔声等级的木结构墙体体系,为木结构墙体在装配式建筑中的高效应用提供技术支撑。【方法】通过小尺寸材料层面的阻抗管法试验,比较分析60~6300 Hz频率范围内工业级弹性橡胶板(橡胶板)、聚氨酯橡胶隔音减震板(聚氨酯板)和聚苯乙烯挤塑板(XPS板)等隔声垫层的隔声性能;基于实验室法开展全尺寸墙体在100~5000 Hz频率范围内的隔声试验,通过1/3倍频程频段18个中心频率对应的单值隔声量,得到墙体计权隔声量(R_(w))、频谱修正量和隔声等级,并与装配式建筑中广泛应用的蒸压加气混凝土(ALC)墙体和正交胶合木(CLT)墙体进行比较。【结果】相较同一厚度的聚氨酯板和XPS板,全频段范围内橡胶板的隔声量较高,且其隔声性能随板厚增加而提高,试验范围内,10 mm厚橡胶板隔声效率最高。常规构造木骨架墙体的隔声量整体上随声波频率增加而提高,该墙体体系在125和3150 Hz处分别出现明显的共振隔声低谷和吻合隔声低谷,其R_(w)为43 dB,用作隔墙或围护构件时的空气声隔声等级分别为4和3级;在墙骨架和定向刨花板(OSB)间设置10 mm厚橡胶板后,受制于木龙骨的声桥作用,墙体隔声性能提升有限,R_(w)增至45 dB,隔声等级未发生改变,常规构造和设置橡胶板的木骨架墙体体系均不满足现行国家标准对普通住宅墙体的隔声要求。当墙骨架采用轻钢骨架且轻钢骨架两侧均覆面双层石膏板(GB)时,该墙体体系的R_(w)增至50 dB,用作隔墙或围护构件时的空气声隔声等级分别升至6和5级;在石膏板和轻钢骨架间设置10 mm压缩玻璃棉条后,R_(w)增至51 dB,隔声等级未发生改变,该轻钢骨架墙体体系满足现行国家标准对普通住宅墙体的隔声要求。与200 mm厚单层和复合ALC墙体相比,试验范围内轻钢骨架墙体的厚度和面密度分别降低35%和70%,但空气声隔声性能更高;针对道路交通、企业生产经营和日常生活等噪音对应的频率范围(160~630 Hz),该轻钢骨架墙体体系的隔声性能增加明显。在常规构造木骨架墙体基础上开洞安装R_(w)为33 dB的窗体,墙体在全频段范围内的隔声频谱特性曲线未发生明显变化,其R_(w)达44 dB,用作隔墙或围护构件时的空气声隔声等级分别为5和4级;常规构造木骨架墙体一侧的GB由单层增至双层、木骨架和OSB间设置10 mm厚橡胶板、木骨架和GB间设置金属减震龙骨制成复合墙体,在复合墙体上安装窗体,该墙体的R_(w)增至48 dB,且在低频段下的共振隔声低谷和高频段下的吻合效应低谷消除或明显变浅,用作隔墙或围护构件时的空气声隔声等级分别升至6和5级,满足现行国家标准对普通住宅墙体的隔声要求。【结果】与木骨架墙体相比,CLT墙体的空气声隔声性能较低;共振隔声低谷、吻合隔声低谷和声桥效应是限制常规构造木骨架墙体隔声性能的瓶颈因素,导致该墙体体系不能满足现行国家标准对普通住宅墙体的隔声要求。将木骨架替换为轻钢骨架,并设置隔声垫层、增加墙面板数量,能够有效提高墙体的空气声隔声性能。 展开更多
关键词 木结构墙体 空气声隔声性能 隔声垫层 轻钢骨架 计权隔声量
下载PDF
湖北省科技新馆结构设计
13
作者 熊森 李霆 +5 位作者 许敏 刘明 陈元坤 陈焰周 陈晓强 刘柳 《建筑结构》 北大核心 2024年第17期1-8,共8页
湖北省科技新馆为大跨度、大悬挑的复杂高层结构。利用4个电梯井筒布置了由矩形钢管混凝土柱+钢支撑(钢板墙)组成的4个筒体巨柱,巨柱支撑着由4榀斜拉长悬臂跨层钢桁架组成的巨梁,形成新型大跨巨型钢框架结构体系。4个筒体巨柱内采用BRB... 湖北省科技新馆为大跨度、大悬挑的复杂高层结构。利用4个电梯井筒布置了由矩形钢管混凝土柱+钢支撑(钢板墙)组成的4个筒体巨柱,巨柱支撑着由4榀斜拉长悬臂跨层钢桁架组成的巨梁,形成新型大跨巨型钢框架结构体系。4个筒体巨柱内采用BRB+摇摆耗能墙的新型联合减震方案以减小地震作用;4榀巨梁内设置斜拉索以减小大悬挑区域的竖向变形;中庭沉浸影院采用新型的“上挂下支”的双曲面网壳结构体系,采用了内衬圆钢管的相贯焊节点保证网壳节点的刚性连接。进行了BRB+摇摆耗能墙大震下的减震分析、桁架与柱连接复杂铸钢节点的有限元分析及节点试验、3层和4层大悬挑角部的舒适度分析及人致振动实测及长悬臂结构的低周往复荷载试验。结果表明:湖北省科技新馆结构体系布置合理,各部分满足设计要求。 展开更多
关键词 湖北省科技新馆 大跨巨型钢框架结构 网壳结构 屈曲约束支撑 摇摆耗能墙 舒适度分析
下载PDF
半刚接钢框架内填实体RC墙结构的地震易损性能评估
14
作者 孙国华 李坤明 +1 位作者 胡月华 黎明 《西安建筑科技大学学报(自然科学版)》 北大核心 2024年第1期38-46,共9页
为评估半刚接钢框架内填实体RC墙结构(PSRCW)的地震易损性能及倒塌储备能力,考虑层数和抗震设防烈度影响合理设计了4个PSRCW结构基准算例,采用Latin超立方抽样方法考虑型钢、混凝土、钢筋等材料力学性能及内填RC墙体厚度几何尺寸的随机... 为评估半刚接钢框架内填实体RC墙结构(PSRCW)的地震易损性能及倒塌储备能力,考虑层数和抗震设防烈度影响合理设计了4个PSRCW结构基准算例,采用Latin超立方抽样方法考虑型钢、混凝土、钢筋等材料力学性能及内填RC墙体厚度几何尺寸的随机性,拓展为4组共计160个PSRCW算例.通过合理选取40条汶川地区实测地震记录,与每组40个PSRCW结构样本随机组合,构成了4组40个地震-结构样本对,通过弹塑性时程分析方法确定了PSRCW结构在“弹性极限”“完全运行”“运行”“生命安全”“接近倒塌”“倒塌”性态下的地震易损性曲线,并进行了抗震性能评估,量化了PSRCW结构的倒塌储备能力.分析结果表明:PSRCW结构的倒塌安全储备系数在3.0~4.3之间,具有良好的抗地震倒塌能力. 展开更多
关键词 钢框架 内填墙 易损性 倒塌安全储备系数
下载PDF
装配式轻钢框架-短肢组合墙结构抗震性能研究
15
作者 曹万林 杨兆源 +1 位作者 刘岩 陈建伟 《建筑结构》 北大核心 2024年第20期10-18,共9页
为研究装配式轻钢框架-短肢组合墙结构的抗震性能,对3个足尺试件(1个轻钢框架结构、1个轻钢框架-短肢桁架结构、1个轻钢框架-短肢桁架组合墙结构)进行了低周反复荷载试验。分析了结构破坏模式、滞回曲线、承载力、刚度退化、变形性能、... 为研究装配式轻钢框架-短肢组合墙结构的抗震性能,对3个足尺试件(1个轻钢框架结构、1个轻钢框架-短肢桁架结构、1个轻钢框架-短肢桁架组合墙结构)进行了低周反复荷载试验。分析了结构破坏模式、滞回曲线、承载力、刚度退化、变形性能、耗能和应变。结果表明:短肢桁架以及短肢桁架组合墙作为结构第一道抗震防线,高效提升了轻钢框架结构的抗震性能;相对于轻钢框架结构试件,轻钢框架-短肢桁架组合墙结构试件的极限承载力提高了28482%,初始刚度提高了24446%;组合墙内的短肢钢桁架与混凝土的共同工作性能良好,混凝土的约束作用抑制了短肢桁架的屈曲失稳,短肢桁架提高了组合墙核心混凝土的变形能力。所提出的装配式轻钢框架-短肢组合墙结构传力路径明确、抗震性能优越、装配便捷,特别适用于低、多层装配式轻钢组合结构,其设计思路同样可用于其他装配式钢框架结构。 展开更多
关键词 装配式组合结构 轻钢框架 短肢组合墙 抗震性能 试验研究
下载PDF
钢筋-砂浆面层交叉条带加固带填充墙框架抗震性能试验研究
16
作者 蒋济同 高之皓 +2 位作者 隋正昂 周献祥 王家存 《建筑结构》 北大核心 2024年第7期30-37,共8页
为研究钢筋-砂浆面层交叉条带加固带填充墙框架结构的抗震性能并建立受剪承载力计算公式,设计制作了8榀低矮填充墙框架结构、3榀高窄填充墙框架结构、1榀未设钢筋-砂浆面层交叉条带加固的对照试件,进行了抗震性能试验。结果表明:钢筋-... 为研究钢筋-砂浆面层交叉条带加固带填充墙框架结构的抗震性能并建立受剪承载力计算公式,设计制作了8榀低矮填充墙框架结构、3榀高窄填充墙框架结构、1榀未设钢筋-砂浆面层交叉条带加固的对照试件,进行了抗震性能试验。结果表明:钢筋-砂浆面层交叉条带加固带填充墙框架的受剪承载力受混凝土强度、框架柱截面尺寸以及交叉条带配筋量影响较大,加固后受剪承载力最高可提升40%;加固后试件的耗能能力和延性均有一定程度的提升;在填充墙上增设的钢筋-砂浆面层交叉条带可视为协助框架结构受力的拉压杆体系。对试验数据进行拟合得到加固后试件受剪承载力计算公式,结果表明:框架、填充墙和交叉条带之间有承载力协同效果,填充墙框架结构的公式计算值和试验值吻合较好。 展开更多
关键词 钢筋-砂浆面层交叉条带 带填充墙框架 受剪承载力 抗震性能
下载PDF
全钢架保温棉墙体轻简化日光温室的创新设计与建造
17
作者 丁明元 梁顺有 +2 位作者 杨桂玲 杨钧国 孔晓霞 《蔬菜》 2024年第6期66-70,共5页
为有效解决传统温室造价高、用工多等问题,有效提高日光温室的建造效率,提升设施农业科技水平,创新设计了全钢架保温棉墙体轻简化日光温室。全钢架保温棉墙体轻简化日光温室是以轻质材料保温棉(玻璃丝棉)为墙体(包括后墙、山墙)、以全... 为有效解决传统温室造价高、用工多等问题,有效提高日光温室的建造效率,提升设施农业科技水平,创新设计了全钢架保温棉墙体轻简化日光温室。全钢架保温棉墙体轻简化日光温室是以轻质材料保温棉(玻璃丝棉)为墙体(包括后墙、山墙)、以全钢骨架组装配套的日光温室,相对于传统土墙温室,具有建造成本低、建造周期短、施工轻便、建造及拆卸方便,节省土地、不破坏自然环境,抗风、抗压能力强,空间大,有利于组装并应用智能水肥一体化、远程终端控制等物联网设施设备,便于设施园艺新产品、新技术的组装配套等优势。建造1座长70 m、跨度10 m的全钢架保温棉墙体轻简化日光温室,造价约为13.87万元,平均198.14元/m^(2),比传统土墙温室总成本减少3万元以上,适宜在河西走廊及西北地区的戈壁、耕地上推广,特别适合在戈壁荒漠地区开展葡萄、樱桃等园艺作物产品的提早、延迟上市栽培,及其他水果及蔬菜、花卉等园艺作物的1年2茬或周年生产及种苗繁育。 展开更多
关键词 日光温室 全钢架 保温棉墙体 轻简化 建造
下载PDF
钢框架外挂ALC墙板十字形新型连接节点抗震性能试验研究 被引量:1
18
作者 丁克伟 杨添 刘运林 《建筑结构》 北大核心 2024年第12期90-97,共8页
提出一种蒸压加气混凝土(ALC)外挂墙板与钢梁的十字形新型连接节点,形式简洁,便于安装。为研究新型节点的抗震性能和工作机理,设计试件SJ-`1和SJ-2,两组试件的ALC墙板与钢框架之间分别采用传统钩头螺栓节点和新型节点进行连接。对两组... 提出一种蒸压加气混凝土(ALC)外挂墙板与钢梁的十字形新型连接节点,形式简洁,便于安装。为研究新型节点的抗震性能和工作机理,设计试件SJ-`1和SJ-2,两组试件的ALC墙板与钢框架之间分别采用传统钩头螺栓节点和新型节点进行连接。对两组试件进行低周往复荷载试验,着重对比分析了两组试件的破坏情况、滞回曲线、骨架曲线、刚度退化曲线和耗能能力,并采用ABAQUS有限元软件对新型节点进行有限元计算。结果表明:十字形新型连接节点能够有效地延缓并减轻墙板的破坏,使钢结构整体表现出更优越的抗震性能和协调变形能力,且模拟数据与试验数据能够较好的吻合,这表明十字形新型连接节点可以安全有效地连接外挂ALC墙板与钢结构主体,且受力、抗震性能良好,具有很高的推广使用价值。 展开更多
关键词 蒸压加气混凝土 钢框架 外挂墙板 新型连接节点 抗震性能
下载PDF
全螺栓装配式钢框架外挂轻质墙板有限元分析
19
作者 樊敏 郭宏超 +2 位作者 李慎 王振山 王华强 《计算力学学报》 CAS CSCD 北大核心 2024年第3期474-482,共9页
基于一体化轻质保温装饰墙板全螺栓装配式钢框架的抗震性能试验研究,本文采用商业有限元软件ABAQUS对结构进行了精细化非线性有限元分析。研究了结构的滞回性能、结构能力、应力分布以及失效模式等,提出了在柱脚和龙骨间设置加劲肋的改... 基于一体化轻质保温装饰墙板全螺栓装配式钢框架的抗震性能试验研究,本文采用商业有限元软件ABAQUS对结构进行了精细化非线性有限元分析。研究了结构的滞回性能、结构能力、应力分布以及失效模式等,提出了在柱脚和龙骨间设置加劲肋的改进设计方案,并对诸如顶底L型件水平板和竖向板螺栓数量、加劲肋形式、结构高跨比以及轴压比等关键设计参数进行了拓展分析。结果表明,采用本文有限元建模方法能够精准地模拟试验的滞回性能,极限承载力与试验最大差值为8.86%,模型失效模式及应力分布与试验现象高度吻合;柱脚和龙骨间加劲肋使柱脚内外翼缘协同变形,减小翼缘局部屈曲,避免龙骨连接处焊缝的应力集中,显著提升了结构承载力;通过优化顶底L型件的螺栓数量和加劲肋形式等设计参数,可进一步提升结构能力;实际工程中应合理控制结构高跨比和轴压比,以满足抗震设防要求。 展开更多
关键词 钢框架 全螺栓装配 轻质墙板 滞回性能 有限元分析
下载PDF
冷弯型钢“框-墙”复合结构墙体上下层间受力性能研究
20
作者 王蕴哲 周天华 +3 位作者 吴函恒 隋璐 王继琴 王帅兵 《建筑科学与工程学报》 CAS 北大核心 2024年第4期31-41,共11页
提出了一种新型的冷弯型钢“框-墙”复合结构墙体,并对2片不同层数的足尺墙体试件进行了拟静力试验。依据破坏形态、滞回曲线、骨架曲线、位移延性系数等性能指标,与单层墙体对比,重点考察双层墙体上下层间的受力性能。此外,基于ABAQUS... 提出了一种新型的冷弯型钢“框-墙”复合结构墙体,并对2片不同层数的足尺墙体试件进行了拟静力试验。依据破坏形态、滞回曲线、骨架曲线、位移延性系数等性能指标,与单层墙体对比,重点考察双层墙体上下层间的受力性能。此外,基于ABAQUS有限元分析软件对双层墙体的滞回性能进行模拟,并对层间连接部位的层间边框梁屈服强度、层间抗拔螺栓间距和高宽比进行参数分析。结果表明:试验全程双层墙体上下层间螺栓连接无明显滑移与拔起,具有半刚性特征,且根据位移计实测结果,墙体上下层间位移趋近于0;在考虑了上下层间连接部位后,双层墙体的位移延性系数和峰值荷载较单层墙体分别降低了1.84%和8.33%,说明冷弯型钢“框-墙”复合结构墙体上下层间传力、连接性较好;层间边框梁屈服强度和层间抗拔螺栓间距对墙体的抗剪承载力和抗侧刚度影响较小,而高宽比对双层墙体的抗侧刚度和抗剪承载力影响较大;研究成果可为该类墙体应用于多层冷弯型钢房屋住宅提供参考。 展开更多
关键词 冷弯型钢组合墙体 双层墙体 拟静力试验 层间受力性能 数值分析