Intensity-modulated proton therapy(IMPT)is becoming essential for proton therapy and is under rapid development.However,for IMPT,the lateral penumbra of the spot-scanning proton beam is still an urgent issue to be sol...Intensity-modulated proton therapy(IMPT)is becoming essential for proton therapy and is under rapid development.However,for IMPT,the lateral penumbra of the spot-scanning proton beam is still an urgent issue to be solved.Patient-specific block collimators(PSBCs),which can block unnecessary doses,play a crucial role in passive scattering delivery technology but are rarely used in spot scanning.One objective of this study is to investigate the lateral penumbra variations of intensity-modulated spot scanning with and without a PSBC.For fields with varying degrees of sharpness and at varying depths in a water phantom,the lateral penumbral widths were calculated using a Monte Carlo-based dose engine from RayStation 6.The results suggest that the lateral penumbral widths can be reduced by more than 30%for uniform target volumes,regardless of whether a range-shifter is used,and that the maximum dose beyond the field edges can be reduced significantly.The results of patient cases show that the doses in organs-at-risk near the edge of the target volume decrease if a PSBC is implemented.This study demonstrates that intensity-modulated spot scanning with a PSBC can effectively reduce the lateral penumbra and block unnecessary doses and is therefore promising for clinical applications in spot-scanning proton therapy.展开更多
A novel method to generate a collimated hollow-laser-beam (HLB) by only a single axicon is proposed. With some reasonable assumptions, the radial light intensity distribution is calculated in detail by diffraction int...A novel method to generate a collimated hollow-laser-beam (HLB) by only a single axicon is proposed. With some reasonable assumptions, the radial light intensity distribution is calculated in detail by diffraction integral theory.The result of numerical simulation shows that this method is valid.Compared with other methods of generating HLB,this scheme is extraordinarily simple in principle and can be utilized experimentally to construct a light trap in atomic fountain for convenience.展开更多
We have built and investigated a detector module for animal SPECT imaging, especially for use in large field of view (FOV) conditions. The module consists of a PMT-based detector and a parallel-hole collimator with ...We have built and investigated a detector module for animal SPECT imaging, especially for use in large field of view (FOV) conditions. The module consists of a PMT-based detector and a parallel-hole collimator with an effective area of 80 mm× 80 mm. The detector is composed of a NaI scintillation crystal array coupled to four H8500 position sensitive photomultiplier tubes (PS-PMT). The intrinsic energy resolution of the detector is 11.5% at 140 keV on average. The planar spatial resolution of the module changes from 2.2 mm to 5.1 mm at different source-to-collimator distances with an unchanged sensitivity of about 34cps/MBq. Additionally, the SPECT Micro Deluxe Phantom imaging was performed with a radius of rotation (ROR) of 40 mm. Using the FBP reconstruction algorithm, a high performance image was obtained, indicating the feasibility of this detector module.展开更多
Background: In linear accelerators, the treatment field’s uniform intensity is achieved by including a flattening filter in the beam. However, to produce more conformal dose distributions, contemporary radiotherapy p...Background: In linear accelerators, the treatment field’s uniform intensity is achieved by including a flattening filter in the beam. However, to produce more conformal dose distributions, contemporary radiotherapy practice now frequently uses fluence and aperture modifying techniques, such as volumetric modulated arc therapy. In these circumstances, the flattening filter in the beam manufacturing process is no longer required. It is therefore necessary to compare the monitor units of 6 MV and flattening filter free plans and how it influences the gamma pass rates to determine which is best for treating cervical cancer with pelvic lymph node metastasis. Methods: VMAT plans for fifteen patients with cervical cancer with pathological pelvic lymph node metastasis were included in this study. Each patient had two VMAT plans using conventional 6 MV beam with flattening filter and one with flattening filter free beam (FFF). The VMAT plans were made using two arcs, and then recalculated to give the planned dose distribution to the detectors in a Delta4 phantom. The VMAT plans were irradiated on the Delta4 phantom using an Elekta linear accelerator (6 MV). Results: The mean monitor unit for the 6 MV plans was 506.3 MU and a standard deviation of 48.6 while that of the FFF plans had a mean MU of 701.5 with a standard deviation of 87.6. The total monitor units (MUs) for the FFF plans were significantly greater than the 6 MV plans (p = 6.1 × 10<sup>-5</sup>). Conclusion: Flattening filter free (FFF) plans require more numbers of monitor units in comparison to conventional 6 MV filtered beams for external radiation of cervical cancer with pelvic lymph nodes involvement.展开更多
Many scientific domains use gamma-ray spectrometry, but non-destructive gamma scanning and gamma emission tomography of radioactive fuel in particular. In the experimental setting, a collimator is frequently employed ...Many scientific domains use gamma-ray spectrometry, but non-destructive gamma scanning and gamma emission tomography of radioactive fuel in particular. In the experimental setting, a collimator is frequently employed to focus on a particular location of interest in the fuel. Predictive models for the transmitted gamma-ray intensity through the collimator are required for both the optimization of instrument design and the planning of measurement campaigns. Gamma-ray transport accuracy is frequently predicted using Monte Carlo radiation transport methods, but using these tools in low-efficiency experimental setups is challenging due to the lengthy computation times needed. This study focused on the full-energy peak intensity that was transmitted through several collimator designs, including rectangle and cylinder. The rate of photons arriving at a detector on the other side of the collimator was calculated for anisotropic source of SNM (U<sub>3</sub>O<sub>8</sub>). Some geometrical assumptions that depended on the source-to-collimator distance and collimator dimensions (length, radius or length, height, and width) were applied to achieve precise findings.展开更多
Complex study of glycerol effects on the skin tissue was performed.The change in optical,weight and geometrical parameters of the rat skin under the action of the glycerol solutions was studied ex vivo.Possible mechan...Complex study of glycerol effects on the skin tissue was performed.The change in optical,weight and geometrical parameters of the rat skin under the action of the glycerol solutions was studied ex vivo.Possible mechanisms of the skin optical clearing under the action of glycerol solutions of different concentrations were discussed.The results can be helpful for refinement of models developed to evaluate the effective diffusion coefficients of glycerol in tissues.展开更多
Optical immersion clearing is a technique that has been widely studied for more than two decades and that is used to originate a temporary transparency effect in biological tissues.If applied in cooperation with clini...Optical immersion clearing is a technique that has been widely studied for more than two decades and that is used to originate a temporary transparency effect in biological tissues.If applied in cooperation with clinical methods it provides optimization of diagnosis and treatment procedures.This technique turns biological tissues more transparent through two main mechanisms-tissue dehydration and refractive index(RI)matching between tissue compo-nents.Such matching is obtained by partial replacement of interstit ial water by a biocompat ible agent that presents higher RI and it can be completely rever sible by natural rehydration in vrivo or by assisted rehydration in ex vivo tissues.Experimental data to characterize and discriminate between the two mechanisms and to find new ones are necessary.Using a simple method,based on collimated transmittance and thickness measurements made from muscle samples under treatment,we have estimated the diffusion properties of glucose,ethylene glycol(EG)and water that were used to perform such char acterization and discrimination.Comparing these properties with data from literature that characterize their diffusion in water we have observed that musde cell membrane permeability limits agent and water diffusion in the muscle.The same experi-mental data has allowed to calculate the optical dearing(OC)eficiency and make an inter-pretation of the internal changes that occurred in muscle during the treatments.The same methodology can now be used to perform similar studies with other agents and in other tissues in order to solve engineering problems at design of inexpensive and robust technologies for a consider.able improvement of optical tomogr aphic techmiques with better contrast and in depth imaging.展开更多
The purpose of this paper is to design a portable two linearly polarized beams absorption biometric system (PTLPBABS) that measures the amount of absorption of the visible collimated beam passing by the sample to know...The purpose of this paper is to design a portable two linearly polarized beams absorption biometric system (PTLPBABS) that measures the amount of absorption of the visible collimated beam passing by the sample to know the absorbance of the sample. The measured object in the system is the gold colloid that the sample produces after a biochemical reaction. After measuring the absorbance of the gold colloid we can obtain the concentrations of the waiting-measured sample and further obtain the concentration of chemical solution contained in the sample. The two linearly polarized beams device can be used to enhance rejection of ambient light and causes PTLPBABS to have excellent data stability measured. The process of the double optical path method increases the opportunities that the visible collimated beam is absorbed, which raise the detection sensitivity of the system to a sensitivity of 0.1%.展开更多
The world's first full Experimental Advanced Superconducting Tokamak(EAST) is designed with the auxiliary heating method of neutral beam injection(NBI)system. Beam collimators are arranged on both sides of the bea...The world's first full Experimental Advanced Superconducting Tokamak(EAST) is designed with the auxiliary heating method of neutral beam injection(NBI)system. Beam collimators are arranged on both sides of the beam channel for absorbing the divergence beam during the beam transmission process in the EAST-NBI system.The gas baffle entrance collimator(GBEC) is a typical high-heat-flux component located at the entrance of gas baffle. An efficient and accurate analysis of its thermodynamic performance is of great significance to explore the working limit and to ensure safe operation of the system under a high-parameter steady-state condition. Based on the thermo-fluid coupled method, thermodynamic analysis and simulation of GBEC is performed to get the working states and corresponding operating limits at different beam extraction conditions. This study provides a theoretical guidance for the next step to achieve long pulse with highpower experimental operation and has an important reference to ensure the safe operation of the system.展开更多
We present an experimental study on tilt-tip(TT) and phase-locking(PL) control in a coherent beam combination(CBC) system of adaptive fiber laser array.The TT control is performed using the adaptive fiber-optics...We present an experimental study on tilt-tip(TT) and phase-locking(PL) control in a coherent beam combination(CBC) system of adaptive fiber laser array.The TT control is performed using the adaptive fiber-optics collimator(AFOC),and the PL control is realized by the phase modulator(PM).Cascaded and simultaneous controls of TT and PL using stochastic parallel gradient descent(SPGD) algorithm are investigated in this paper.Two-fiber-laser-,four-fiber-laser-,and six-fiber-laser-arrays are employed to study the TT and PL control.In the cascaded control system,only one high-speed CMOS camera is used to collect beam data and a computer is used as the controller.In a simultaneous control system one high-speed CMOS camera and one photonic detector(PD) are employed,and a computer and a control circuit based on field programmable gate array(FPGA) are used as the controllers.Experimental results reveal that both cascaded and simultaneous controls of TT using AFOC and PL using PM in fiber laser array are feasible and effective.Cascaded control is more effective in static control situation and simultaneous control can be applied to the dynamic control system directly.The control signals of simultaneous PL and TT disturb each other obviously and TT and PL control may compete with each other,so the control effect is limited.展开更多
Direct-write atom lithography,one of the potential nanofabrication techniques,is restricted by some difficulties in producing optical masks for the deposition of complex structures.In order to make further progress,a ...Direct-write atom lithography,one of the potential nanofabrication techniques,is restricted by some difficulties in producing optical masks for the deposition of complex structures.In order to make further progress,a structured mirror array is developed to transversely collimate the chromium atomic beam in two dimensions.The best collimation is obtained when the laser red detunes by natural line-width of transition 7S3 → 7P40 of the chromium atom.The collimation ratio is 0.45 vertically(in x axis),and it is 0.55 horizontally(in y axis).The theoretical model is also simulated,and success of our structured mirror array is achieved.展开更多
The transport of sub-picosecond laser-driven fast electrons in nanopore array targets is studied.Attributed to the generation of micro-structured magnetic fields,most fast electron beams are proven to be effectively g...The transport of sub-picosecond laser-driven fast electrons in nanopore array targets is studied.Attributed to the generation of micro-structured magnetic fields,most fast electron beams are proven to be effectively guided and restricted during the propagation.Different transport patterns of fast electrons in the targets are observed in experiments and reproduced by particle-in-cell simulations,representing two components:initially collimated low-energy electrons in the center and high-energy scattering electrons turning into surrounding annular beams.The critical energy for confined electrons is deduced theoretically.The electron guidance and confinement by the nano-structured targets offer a technological approach to manipulate and optimize the fast electron transport by properly modulating pulse parameters and target design,showing great potential in many applications including ion acceleration,microfocus x-ray sources and inertial confinement fusion.展开更多
A space-borne hard X-ray collimator,comprising 91 pairs of grids,has been developed for the Hard X-ray Imager(HXI).The HXI is one of the three scientific instruments onboard the first Chinese solar mission:the Advance...A space-borne hard X-ray collimator,comprising 91 pairs of grids,has been developed for the Hard X-ray Imager(HXI).The HXI is one of the three scientific instruments onboard the first Chinese solar mission:the Advanced Space-based Solar Observatory(ASO-S).The HXI collimator(HXI-C)is a spatial modulation X-ray telescope designed to observe hard X-rays emitted by energetic electrons in solar flares.This paper presents the detailed design of the HXI-C for the qualification model that will be inherited by the flight model.Series tests on the HXI-C qualification model are reported to verify the ability of the HXI-C to survive the launch and to operate normally in on-orbit environments.Furthermore,results of the X-ray beam test for the HXI-C are presented to indirectly identify the working performance of the HXI-C.展开更多
AIM: To study the leakage-penumbra(LP) effect with a proposed correction method for the step-and-shoot intensity modulated radiation therapy(IMRT).METHODS: Leakage-penumbra dose profiles from 10 randomly selected pros...AIM: To study the leakage-penumbra(LP) effect with a proposed correction method for the step-and-shoot intensity modulated radiation therapy(IMRT).METHODS: Leakage-penumbra dose profiles from 10 randomly selected prostate IMRT plans were studied. The IMRT plans were delivered by a Varian 21 EX linear accelerator equipped with a 120-leaf multileaf collimator(MLC). For each treatment plan created by the Pinnacle3 treatment planning system,a 3-dimensional LP dose distribution generated by 5 coplanar photon beams,starting from 0o with equal separation of 72 o,was investigated. For each photon beam used in the stepand-shoot IMRT plans,the first beam segment was set to have the largest area in the MLC leaf-sequencing,and was equal to the planning target volume(PTV). The overshoot effect(OSE) and the segment positional errors were measured using a solid water phantom with Kodak(TL and X-OMAT V) radiographic films. Film dosimetric analysis and calibration were carried out using a film scanner(Vidar VXR-16). The LP dose profiles were determined by eliminating the OSE and segment positional errors with specific individual irradiations. RESULTS: A non-uniformly distributed leaf LP dose ranging from 3% to 5% of the beam dose was measured in clinical IMRT beams. An overdose at the gap between neighboring segments,represented as dose peaks of up to 10% of the total BP,was measured. The LP effect increased the dose to the PTV and surrounding critical tissues. In addition,the effectdepends on the number of beams and segments for each beam. Segment positional error was less than the maximum tolerance of 1 mm under a dose rate of 600 monitor units per minute in the treatment plans. The OSE varying with the dose rate was observed in all photon beams,and the effect increased from 1 to 1.3 Gy per treatment of the rectal intersection. As the dosimetric impacts from the LP effect and OSE may increase the rectal post-radiation effects,a correction of LP was proposed and demonstrated for the central beam profile for one of the planned beams. CONCLUSION: We concluded that the measured dosimetric impact of the LP dose inaccuracy from photon beam segment in step-and-shoot IMRT can be corrected.展开更多
基金supported by the Key Program of the 13th Five-Year Plan,the Hefei Institutes of Physical Science of the Chinese Academy of Sciences(No.KP-2017-24)
文摘Intensity-modulated proton therapy(IMPT)is becoming essential for proton therapy and is under rapid development.However,for IMPT,the lateral penumbra of the spot-scanning proton beam is still an urgent issue to be solved.Patient-specific block collimators(PSBCs),which can block unnecessary doses,play a crucial role in passive scattering delivery technology but are rarely used in spot scanning.One objective of this study is to investigate the lateral penumbra variations of intensity-modulated spot scanning with and without a PSBC.For fields with varying degrees of sharpness and at varying depths in a water phantom,the lateral penumbral widths were calculated using a Monte Carlo-based dose engine from RayStation 6.The results suggest that the lateral penumbral widths can be reduced by more than 30%for uniform target volumes,regardless of whether a range-shifter is used,and that the maximum dose beyond the field edges can be reduced significantly.The results of patient cases show that the doses in organs-at-risk near the edge of the target volume decrease if a PSBC is implemented.This study demonstrates that intensity-modulated spot scanning with a PSBC can effectively reduce the lateral penumbra and block unnecessary doses and is therefore promising for clinical applications in spot-scanning proton therapy.
基金This work was supported by the National Natural Science Foundation of China (No. 60008002)the Key Oriental Project of Chinese Academy of Sciences (KGCX_2-SW-110)the Shanghai Optical-Tech Special Project (01DJGK015).
文摘A novel method to generate a collimated hollow-laser-beam (HLB) by only a single axicon is proposed. With some reasonable assumptions, the radial light intensity distribution is calculated in detail by diffraction integral theory.The result of numerical simulation shows that this method is valid.Compared with other methods of generating HLB,this scheme is extraordinarily simple in principle and can be utilized experimentally to construct a light trap in atomic fountain for convenience.
基金Supported by Natural Science Foundation of China(10805049,10775149)
文摘We have built and investigated a detector module for animal SPECT imaging, especially for use in large field of view (FOV) conditions. The module consists of a PMT-based detector and a parallel-hole collimator with an effective area of 80 mm× 80 mm. The detector is composed of a NaI scintillation crystal array coupled to four H8500 position sensitive photomultiplier tubes (PS-PMT). The intrinsic energy resolution of the detector is 11.5% at 140 keV on average. The planar spatial resolution of the module changes from 2.2 mm to 5.1 mm at different source-to-collimator distances with an unchanged sensitivity of about 34cps/MBq. Additionally, the SPECT Micro Deluxe Phantom imaging was performed with a radius of rotation (ROR) of 40 mm. Using the FBP reconstruction algorithm, a high performance image was obtained, indicating the feasibility of this detector module.
文摘Background: In linear accelerators, the treatment field’s uniform intensity is achieved by including a flattening filter in the beam. However, to produce more conformal dose distributions, contemporary radiotherapy practice now frequently uses fluence and aperture modifying techniques, such as volumetric modulated arc therapy. In these circumstances, the flattening filter in the beam manufacturing process is no longer required. It is therefore necessary to compare the monitor units of 6 MV and flattening filter free plans and how it influences the gamma pass rates to determine which is best for treating cervical cancer with pelvic lymph node metastasis. Methods: VMAT plans for fifteen patients with cervical cancer with pathological pelvic lymph node metastasis were included in this study. Each patient had two VMAT plans using conventional 6 MV beam with flattening filter and one with flattening filter free beam (FFF). The VMAT plans were made using two arcs, and then recalculated to give the planned dose distribution to the detectors in a Delta4 phantom. The VMAT plans were irradiated on the Delta4 phantom using an Elekta linear accelerator (6 MV). Results: The mean monitor unit for the 6 MV plans was 506.3 MU and a standard deviation of 48.6 while that of the FFF plans had a mean MU of 701.5 with a standard deviation of 87.6. The total monitor units (MUs) for the FFF plans were significantly greater than the 6 MV plans (p = 6.1 × 10<sup>-5</sup>). Conclusion: Flattening filter free (FFF) plans require more numbers of monitor units in comparison to conventional 6 MV filtered beams for external radiation of cervical cancer with pelvic lymph nodes involvement.
文摘Many scientific domains use gamma-ray spectrometry, but non-destructive gamma scanning and gamma emission tomography of radioactive fuel in particular. In the experimental setting, a collimator is frequently employed to focus on a particular location of interest in the fuel. Predictive models for the transmitted gamma-ray intensity through the collimator are required for both the optimization of instrument design and the planning of measurement campaigns. Gamma-ray transport accuracy is frequently predicted using Monte Carlo radiation transport methods, but using these tools in low-efficiency experimental setups is challenging due to the lengthy computation times needed. This study focused on the full-energy peak intensity that was transmitted through several collimator designs, including rectangle and cylinder. The rate of photons arriving at a detector on the other side of the collimator was calculated for anisotropic source of SNM (U<sub>3</sub>O<sub>8</sub>). Some geometrical assumptions that depended on the source-to-collimator distance and collimator dimensions (length, radius or length, height, and width) were applied to achieve precise findings.
基金This work was carried out under the support from the Russian Foundation for Basic Research(Grant Nos.18-52-16025 and 19-32-90224)The Fund for Promoting Innovation grant UMNIK-19/HealthNet.NTI-2019 No.15929GU/2020 of 07.23.2020(code 0059878,application(U-65096)).
文摘Complex study of glycerol effects on the skin tissue was performed.The change in optical,weight and geometrical parameters of the rat skin under the action of the glycerol solutions was studied ex vivo.Possible mechanisms of the skin optical clearing under the action of glycerol solutions of different concentrations were discussed.The results can be helpful for refinement of models developed to evaluate the effective diffusion coefficients of glycerol in tissues.
基金support from the Government of Russian Federation(Grant No.14.Z50.31.0004)The Tomsk State University Academic D.I.Mendeleev Fund Program.
文摘Optical immersion clearing is a technique that has been widely studied for more than two decades and that is used to originate a temporary transparency effect in biological tissues.If applied in cooperation with clinical methods it provides optimization of diagnosis and treatment procedures.This technique turns biological tissues more transparent through two main mechanisms-tissue dehydration and refractive index(RI)matching between tissue compo-nents.Such matching is obtained by partial replacement of interstit ial water by a biocompat ible agent that presents higher RI and it can be completely rever sible by natural rehydration in vrivo or by assisted rehydration in ex vivo tissues.Experimental data to characterize and discriminate between the two mechanisms and to find new ones are necessary.Using a simple method,based on collimated transmittance and thickness measurements made from muscle samples under treatment,we have estimated the diffusion properties of glucose,ethylene glycol(EG)and water that were used to perform such char acterization and discrimination.Comparing these properties with data from literature that characterize their diffusion in water we have observed that musde cell membrane permeability limits agent and water diffusion in the muscle.The same experi-mental data has allowed to calculate the optical dearing(OC)eficiency and make an inter-pretation of the internal changes that occurred in muscle during the treatments.The same methodology can now be used to perform similar studies with other agents and in other tissues in order to solve engineering problems at design of inexpensive and robust technologies for a consider.able improvement of optical tomogr aphic techmiques with better contrast and in depth imaging.
文摘The purpose of this paper is to design a portable two linearly polarized beams absorption biometric system (PTLPBABS) that measures the amount of absorption of the visible collimated beam passing by the sample to know the absorbance of the sample. The measured object in the system is the gold colloid that the sample produces after a biochemical reaction. After measuring the absorbance of the gold colloid we can obtain the concentrations of the waiting-measured sample and further obtain the concentration of chemical solution contained in the sample. The two linearly polarized beams device can be used to enhance rejection of ambient light and causes PTLPBABS to have excellent data stability measured. The process of the double optical path method increases the opportunities that the visible collimated beam is absorbed, which raise the detection sensitivity of the system to a sensitivity of 0.1%.
基金supported by the National Natural Science Foundation of China(No.11605234)the Foundation of ASIPP(No.DSJJ-15-GC02)
文摘The world's first full Experimental Advanced Superconducting Tokamak(EAST) is designed with the auxiliary heating method of neutral beam injection(NBI)system. Beam collimators are arranged on both sides of the beam channel for absorbing the divergence beam during the beam transmission process in the EAST-NBI system.The gas baffle entrance collimator(GBEC) is a typical high-heat-flux component located at the entrance of gas baffle. An efficient and accurate analysis of its thermodynamic performance is of great significance to explore the working limit and to ensure safe operation of the system under a high-parameter steady-state condition. Based on the thermo-fluid coupled method, thermodynamic analysis and simulation of GBEC is performed to get the working states and corresponding operating limits at different beam extraction conditions. This study provides a theoretical guidance for the next step to achieve long pulse with highpower experimental operation and has an important reference to ensure the safe operation of the system.
文摘We present an experimental study on tilt-tip(TT) and phase-locking(PL) control in a coherent beam combination(CBC) system of adaptive fiber laser array.The TT control is performed using the adaptive fiber-optics collimator(AFOC),and the PL control is realized by the phase modulator(PM).Cascaded and simultaneous controls of TT and PL using stochastic parallel gradient descent(SPGD) algorithm are investigated in this paper.Two-fiber-laser-,four-fiber-laser-,and six-fiber-laser-arrays are employed to study the TT and PL control.In the cascaded control system,only one high-speed CMOS camera is used to collect beam data and a computer is used as the controller.In a simultaneous control system one high-speed CMOS camera and one photonic detector(PD) are employed,and a computer and a control circuit based on field programmable gate array(FPGA) are used as the controllers.Experimental results reveal that both cascaded and simultaneous controls of TT using AFOC and PL using PM in fiber laser array are feasible and effective.Cascaded control is more effective in static control situation and simultaneous control can be applied to the dynamic control system directly.The control signals of simultaneous PL and TT disturb each other obviously and TT and PL control may compete with each other,so the control effect is limited.
基金Project supported by the Shanghai Nanoscience Foundation,China (Grant Nos. 0852nm07000 and 0952nm07000)the National Natural Science Foundation of China (Grant Nos. 10804084 and 91123022)+1 种基金the National Key Technology R & D Program,China (Grant No. 2006BAF06B08)the Specialized Research Fund for the Doctoral Program of Ministry of High Education of China (Grant No. 200802471008)
文摘Direct-write atom lithography,one of the potential nanofabrication techniques,is restricted by some difficulties in producing optical masks for the deposition of complex structures.In order to make further progress,a structured mirror array is developed to transversely collimate the chromium atomic beam in two dimensions.The best collimation is obtained when the laser red detunes by natural line-width of transition 7S3 → 7P40 of the chromium atom.The collimation ratio is 0.45 vertically(in x axis),and it is 0.55 horizontally(in y axis).The theoretical model is also simulated,and success of our structured mirror array is achieved.
基金supported by the National Key R&D Program of China(Grant No.2016YFA0401100)the Science and Technology on Plasma Physics Laboratory(Grant Nos.6142A04180201 and JCKYS2020212006)+1 种基金National Natural Science Foundation of China(Grant No.11975214)the Science Challenge Program(Grant Nos.TZ2016005 and TZ2018005)
文摘The transport of sub-picosecond laser-driven fast electrons in nanopore array targets is studied.Attributed to the generation of micro-structured magnetic fields,most fast electron beams are proven to be effectively guided and restricted during the propagation.Different transport patterns of fast electrons in the targets are observed in experiments and reproduced by particle-in-cell simulations,representing two components:initially collimated low-energy electrons in the center and high-energy scattering electrons turning into surrounding annular beams.The critical energy for confined electrons is deduced theoretically.The electron guidance and confinement by the nano-structured targets offer a technological approach to manipulate and optimize the fast electron transport by properly modulating pulse parameters and target design,showing great potential in many applications including ion acceleration,microfocus x-ray sources and inertial confinement fusion.
基金supported by the Strategic Priority Research Program on Space Science,Chinese Academy of Sciences(No.XDA 15320104)the National Natural Science Foundation of China(Grant Nos.11803093,11973097 and 12022302)the Scientific Instrument Developing Project of the CAS(No.20200077)。
文摘A space-borne hard X-ray collimator,comprising 91 pairs of grids,has been developed for the Hard X-ray Imager(HXI).The HXI is one of the three scientific instruments onboard the first Chinese solar mission:the Advanced Space-based Solar Observatory(ASO-S).The HXI collimator(HXI-C)is a spatial modulation X-ray telescope designed to observe hard X-rays emitted by energetic electrons in solar flares.This paper presents the detailed design of the HXI-C for the qualification model that will be inherited by the flight model.Series tests on the HXI-C qualification model are reported to verify the ability of the HXI-C to survive the launch and to operate normally in on-orbit environments.Furthermore,results of the X-ray beam test for the HXI-C are presented to indirectly identify the working performance of the HXI-C.
基金supported by the Medical Physics Department of GRRCC,Kitchener,Ontario
文摘AIM: To study the leakage-penumbra(LP) effect with a proposed correction method for the step-and-shoot intensity modulated radiation therapy(IMRT).METHODS: Leakage-penumbra dose profiles from 10 randomly selected prostate IMRT plans were studied. The IMRT plans were delivered by a Varian 21 EX linear accelerator equipped with a 120-leaf multileaf collimator(MLC). For each treatment plan created by the Pinnacle3 treatment planning system,a 3-dimensional LP dose distribution generated by 5 coplanar photon beams,starting from 0o with equal separation of 72 o,was investigated. For each photon beam used in the stepand-shoot IMRT plans,the first beam segment was set to have the largest area in the MLC leaf-sequencing,and was equal to the planning target volume(PTV). The overshoot effect(OSE) and the segment positional errors were measured using a solid water phantom with Kodak(TL and X-OMAT V) radiographic films. Film dosimetric analysis and calibration were carried out using a film scanner(Vidar VXR-16). The LP dose profiles were determined by eliminating the OSE and segment positional errors with specific individual irradiations. RESULTS: A non-uniformly distributed leaf LP dose ranging from 3% to 5% of the beam dose was measured in clinical IMRT beams. An overdose at the gap between neighboring segments,represented as dose peaks of up to 10% of the total BP,was measured. The LP effect increased the dose to the PTV and surrounding critical tissues. In addition,the effectdepends on the number of beams and segments for each beam. Segment positional error was less than the maximum tolerance of 1 mm under a dose rate of 600 monitor units per minute in the treatment plans. The OSE varying with the dose rate was observed in all photon beams,and the effect increased from 1 to 1.3 Gy per treatment of the rectal intersection. As the dosimetric impacts from the LP effect and OSE may increase the rectal post-radiation effects,a correction of LP was proposed and demonstrated for the central beam profile for one of the planned beams. CONCLUSION: We concluded that the measured dosimetric impact of the LP dose inaccuracy from photon beam segment in step-and-shoot IMRT can be corrected.