期刊文献+
共找到2,716篇文章
< 1 2 136 >
每页显示 20 50 100
Measurements Of Cerebral Blood Flow in Postasphyxiated Newborns by Color Doppler Imaging(CDI) 被引量:7
1
作者 常立文 汪元芳 刘婉君 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1996年第4期249-252,共4页
Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the... Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the anterior, middle and posterior cerebral arteries were studied. The results showed evidently lower systolic amplitude in patients than that in normal subjects. End diastolic amplitude was zero in part of vessels, and values of bloed flow variables were all lower in day 1 of the life as compared with the control groups. Frequency spectrum recovered to normal patterns in 9 survived infants in day 2. but blood flow variables recovered to normal by day 7. Values of resistance index (RI) rose to 1 in some vessels of moderate hypoxic ischemic encephalopathy (HIE) infants and stayed at 1 in the severe HIE infants. It is concluded that low CBF plays a key role in brain damage of post-asphyxiated newborns and RI may be an important parameter in the evaluation prognosis. 展开更多
关键词 asphyxiated newborns cerebral blood flow ultrasound imaging color doppler
下载PDF
Hemodynamic Changes on Color Doppler Flow Imaging and Intravenous Contrast-enhanced Ultrasound for Assessing Transplanted Liver and Early Diagnosis of Complications 被引量:1
2
作者 黄道中 陈云超 +1 位作者 李开艳 张青萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期284-286,共3页
The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discu... The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS. 展开更多
关键词 color doppler flow imaging liver transplantation HEMODYNAMICS postoperative complications intravenous contrast-enhanced ultrasound
下载PDF
Assessment of Uterine Receptivity by Endometrial and Subendometrial Blood Flows Measured by Vaginal Color Doppler Ultrasound in Women Undergoing IVF Treatment 被引量:1
3
作者 Min-zhi GAO Xiao-ming ZHAO +3 位作者 Wen-ying LI Gui-mei LIU Xiao-feng JIA Hui-qin ZHANG 《Journal of Reproduction and Contraception》 CAS 2007年第3期205-212,共8页
Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infert... Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infertile patients undergoing the first IVF/ICSI-ET cycle were recruited. Three groups were divided according to a color Doppler ultrasound examination performed on the day of hCG injection. Group A, endometrial and subendometrial blood flows were 2 branches and below; group B, endometrial and subendometrial blood flows were between 3 and 4 branches; group C, endometrial and subendometrial blood flows were 5 branches and above. Patients were transferred 1-3 embryos each. Demographic data, ovarian responses, endometrial thickness, PI, RI, development of embryo and IVF result among groups were compared. Results Demographic data, ovarian responses, endometrial thickness, PI, RI and development of embryo among groups have no significant difference. The pregnancy rate of group A was significantly lower than that of group B (P〈0.05) and group C (P〈0.01). The implantation rate of group A was significantly lower than than of group C (P〈0.01). There was no significant difference of the rate of pregnancy and implantation between group B and group C (P〉0.05). Conclusion Endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound is a good predicator of pregnancy during IVF treatment. A good endometrial and subendometrial blood flows is benefit for the result of IVF. 展开更多
关键词 endometrial and subendometrial blood flows endometrial receptivity in vitro fertilization-embryo transfer (IVF) color doppler ultrasound
下载PDF
Measurement of Liver Size and Intrahepatic Blood Flow of Red-eared Turtles by Color Doppler Ultrasound
4
作者 Cheng Yu Xie Fuqiang 《Animal Husbandry and Feed Science》 CAS 2015年第4期246-248,共3页
In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The res... In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The results showed that the fight hepatic lobe could be scanned through the right carotid anterior acoustic win- dow, and the left hepatic lobe could be scanned through the left carotid anterior acoustic window, but the vision would be obstructed by the air in trachea. The liver could also be scanned through the left femoral anterior acoustic window and the fight femoral anterior acoustic window when filling of bladder was good. The correla- tion regression analysis suggested that estimated values of liver showed no linear relationship with weight, the longest back curve and the widest back curve. Through the study, the normal indicators for ultrasound examination of red-eared turtle liver were established, in order to provide a reference for examination of turtle liver. 展开更多
关键词 Red-eared turtle color doppler ultrasound LIVER blood flow
下载PDF
Real-time Three-Dimensional Color Doppler Flow Imaging: An Improved Technique for Quantitative Analysis of Aortic Regurgitation 被引量:3
5
作者 吕清 刘夏天 +3 位作者 谢明星 王新房 王静 庄磊 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第1期148-152,共5页
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT... The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF. 展开更多
关键词 real-time three-dimensional echocardiography color doppler flow imaging aortic regurgitation
下载PDF
FEASIBILITY STUDY OF AN ULTRASOUND CONTRAST AGENT(LEVOVIST) IN COLOR DOPPLER IMAGING OF LIVER NEOPLASMS 被引量:6
6
作者 姜玉新 戴晴 +4 位作者 刘吉斌 张缙熙 常欣 蔡胜 谭莉 《Chinese Medical Sciences Journal》 CAS CSCD 1999年第3期167-169,共3页
INTRODUCTIONColorDopplerimaging(CDI)forthenoninvasiveassesmentofbothnormalandabnormallivervascularityhaveo... INTRODUCTIONColorDopplerimaging(CDI)forthenoninvasiveassesmentofbothnormalandabnormallivervascularityhaveoferedasignificant... 展开更多
关键词 肝脏肿瘤 彩色多普勒显像 诊断 超声波检查
下载PDF
Assessment of voluntary rhythmic muscle contraction-induced exercising blood flow variability measured by Doppler ultrasound 被引量:1
7
作者 Takuya Osada Bengt Saltin Goran Radegran 《Open Journal of Molecular and Integrative Physiology》 2013年第4期158-165,共8页
Given recent technological developments, ultrasound Doppler can provide valuable measurements of blood velocity/flow in the conduit artery with high temporal resolution. In human-applied science such as exercise physi... Given recent technological developments, ultrasound Doppler can provide valuable measurements of blood velocity/flow in the conduit artery with high temporal resolution. In human-applied science such as exercise physiology, hemodynamic measurements in the conduit artery is commonly performed by blood flow feeding the exercising muscle, as the increase in oxygen uptake (calculated as a product of arterial blood flow to the exercising limb and the arterio-venous oxygen difference) is directly proportional to the work performed. The increased oxygen demand with physical activity is met through a central mechanism, an increase in cardiac output and blood pressure, as well as a peripheral mechanism, an increase in vascular conductance and oxygen extraction (a major part of the whole exercising muscles) from the blood. The increase in exercising muscle blood flow in relation to the target workload (quantitative response) may be one indicator in circulatory adjustment for the ac- tivity of muscle metabolism. Therefore, the determination of local blood flow dynamics (potential oxygen supply) feeding repeated (rhythmic) muscle contractions can contribute to the understanding of the factors limiting work capacity including, for instance, muscle metabolism, substance utilization and magnitude of vasodilatation in the exercising muscle. Using non-invasive measures of pulsed Doppler ultrasound, the validity of blood velocity/flow in the forearm or lower limb conduit artery feeding to the muscle has been previously demonstrated during rhythmic muscle exercise. For the evaluation of exercising blood flow, not only muscle contraction induced internal physiological variability, or fluctuations in the magnitude of blood velocity due to spontaneous muscle contraction and relaxation induced changes in force curve intensity, superimposed in cardiac beat-by-beat, but also the alterations in the blood velocity (external variability) due to a temporary sudden change in the achieved workload, compared to the target workload, should be considered. Furthermore, a small amount of inconsistency in the voluntary muscle contraction force at each kick seems to be unavoidable, and may influence exercising muscle blood flow, although subjects attempt to perform precisely similar repeated voluntary muscle contractions at target workload (muscle contraction force). This review presents the methodological considerations for the variability of exercising blood velocity/flow in the limb conduit artery during dynamic leg exercise assessed by pulsed Doppler ultrasound in relation to data previously reported in original research. 展开更多
关键词 Exercising blood flow doppler ultrasound Muscle Contraction blood flow Alterations
下载PDF
Left Coronary Artery Fistula Identified by Color Doppler Flow Imaging
8
作者 杨娅 李治安 +1 位作者 王新房 邓又兵 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1995年第3期176-177,共2页
Coronary artery fistula (CAF) is an abnormal communication between a coronary artery and a cardiac chamber, great vessel,or other vascular structures. The presence of the fistula is usually identified by angiography. ... Coronary artery fistula (CAF) is an abnormal communication between a coronary artery and a cardiac chamber, great vessel,or other vascular structures. The presence of the fistula is usually identified by angiography. In this paper, the diagnosis of left coronary artery-right ventricle fistula was made by color Doppler before angiography? and it was confirmed by surgery.Color Doppler flow imaging is a noninvasive method which can reveal the proximal dilatation, the course and the draining site of CAF. 展开更多
关键词 coronary artery fistula color doppler flow imaging
下载PDF
Role of color Doppler flow imaging in applicable anatomy of spleen vessels
9
作者 Wei-Li Xu Suo-Lin Li +2 位作者 Yan Wang Meng Li Ai-Guo Niu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第5期607-611,共5页
AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to defi ne its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic spl... AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to defi ne its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic splenectomy (LS) for various hematopathies and autoimmune diseases were randomly selected from April 2005 to May 2008. Anatomic types of spleen pedicle, adjacent relations between spleen vessels and pancreas, diameters of spleen artery and vein were detected and recorded by preoperative CDFI. Different operative procedures were performed according to different anatomic frameworks. The parameters were recorded by telerecording during LS and compared with those by preoperative CDFI using Chi-square test. RESULTS: Two anatomic types of spleen pedicle and four different adjacent relations between spleen vessels and pancreas were detected by CDFI. The diameters of spleen artery and vein detected by CDFI were 0.46 ± 0.09 cm and 0.85 ± 0.35 cm, respectively. There was no statistical difference between the parameters recorded by CDFI and by telerecording (χ2 = 0.250, 0.677, P > 0.05). LS was successfully performed following the anatomic information provided by preoperative CDFI.CONCLUSION: Different anatomic frameworks of spleen vessels can be provided by preoperative CDFI, which instructs micro-invasive operation of spleen and increase the safety of operation. 展开更多
关键词 人体解剖学 METHODS 实验
下载PDF
PRELIMINARY APPLICATION OF COLOR DOPPLER FLOW IMAGING IN THE LOCALIZATION OF PARATHYROID ADENOMAS
10
作者 张缙熙 李建初 《Chinese Medical Sciences Journal》 CAS CSCD 1994年第3期187-189,共3页
PRELIMINARYAPPLICATIONOFCOLORDOPPLERFLOWIMAGINGINTHELOCALIZATIONOFPARATHYROIDADENOMASZhanJinxi(张缙熙)andLiJian... PRELIMINARYAPPLICATIONOFCOLORDOPPLERFLOWIMAGINGINTHELOCALIZATIONOFPARATHYROIDADENOMASZhanJinxi(张缙熙)andLiJianchu(李建初)(PUMCHosp... 展开更多
关键词 彩色多普勒血流显像 甲状旁腺肿瘤 诊断 鉴别诊断 CDFI
下载PDF
Measurement of the exercising blood flow during rhythmical muscle contractions assessed by Doppler ultrasound:Methodological considerations
11
作者 Takuya Osada Bengt Saltin +1 位作者 Stefan P.Mortensen Goran Radegran 《Journal of Biomedical Science and Engineering》 2012年第12期779-788,共10页
Given the recent technological developments, ultra-sound Doppler can provide valuable measurements of arterial blood flow with high temporal resolution. In a clinical setting, measurements of hemodynamics is used to m... Given the recent technological developments, ultra-sound Doppler can provide valuable measurements of arterial blood flow with high temporal resolution. In a clinical setting, measurements of hemodynamics is used to monitor, diagnose and manage changes in blood velocity profile for cardiac valve disease, relatively large vessel stenosis and other cardiovascular diseases. In health science and preventive medicine for cardiovascular disease with exercise therapy, evaluation of cardiac and vascular function is a useful indicator not only at rest but also during exercise, leading to improved exercise tolerance as well as physical activity. During exercise, the increase in oxygen uptake (calculated as product of arterial blood flow to the exercising limb and the arteriovenous oxygen difference) is directly proportional to the work performed. The increased oxygen demand is met through a central mechanism, an increase in cardiac output and blood pressure, as well as a peripheral mechanism, an increase in vascular conductance and oxygen extraction (major part in the whole exercising muscles) from the blood. Therefore, the determination of the local blood flow dynamics (potential oxygen supply) feeding to rhythmic muscle contractions can contribute to the understanding of the factors limiting the work capacity including, for instance the muscle metabolism, substance utilization and vasodilatation in the exercising muscle. Using non-invasive measures of pulsed Doppler ultrasound the validity of evaluating blood velocity/flow in the fore- arm or lower limb conduit artery feeding to the mus- cle is demonstrated during rhythmic muscle exercise;however the exercising blood velocity profile (fast Fourier transformation) due to muscle contractions is always seen as a physiological variability or fluctuations in the magnitude in blood velocity due to the spontaneous muscle contraction and relaxation induced changes in force curve intensity. Considering the above mentioned variation in blood velocity in relation to muscle contractions may provide valuable information for evaluating the blood flow dynamics during exercise. This review presents the methodological concept that underlines the methodological considerations for determining the exercising blood velocity/flow in the limb conduit artery in relation the exercise model of dynamic leg exercise assessed by pulsed Doppler ultrasonography. 展开更多
关键词 Exercising blood flow doppler ultrasound Muscle Contraction Physiological flow Variations
下载PDF
Thrombelastography and color Doppler flow imaging in the perioperative period after closed lower limb fracture
12
作者 徐志强 《外科研究与新技术》 2011年第2期114-115,共2页
Objective To observe the changes of thrombelastography (TEG) and color Doppler flow imaging (CDFI) in the perioperative period after closed lower limb fracture.Methods Fasting venous blood samples in the morning from ... Objective To observe the changes of thrombelastography (TEG) and color Doppler flow imaging (CDFI) in the perioperative period after closed lower limb fracture.Methods Fasting venous blood samples in the morning from 11 healthy adults were used 展开更多
关键词 CDFI Thrombelastography and color doppler flow imaging in the perioperative period after closed lower limb fracture flow
下载PDF
Design of axial flaps with color Doppler flow imaging technique for repairing deep wounds of heels
13
作者 黎洪棉 《外科研究与新技术》 2005年第3期215-215,共1页
To report the methods and effect of axial pattern flap on lower limb in repairing deep wounds of heels by using color Doppler flow imaging (CDFI) technique so as to solve the ever before problems that the vessel can n... To report the methods and effect of axial pattern flap on lower limb in repairing deep wounds of heels by using color Doppler flow imaging (CDFI) technique so as to solve the ever before problems that the vessel can not be displayed in designing axial flap.Methods Suitable axial flaps on lower limbs were selected according to the character of the wounds.There were 25 flaps including 10 cases of the distal-based sural neurovascular flap,nine medial sole flap and six medial leg flap.All the axial pattern flaps were designed on the basis of traditional design ways before operation;then,CDFI appliance with high resolution was used to examine the starting spot,exterior diameter,trail and length of the flap’s major artery.The flaps were redesigned according to the results of CDFI and transferred to cover the wounds.In the meantime,both the results of operation and examination were compared.Results The major artery’s starting spot,exterior diameter,trail and anatomic layers were displayed clearly,in consistency with the results of operation.The flaps survived completely and recovered well,with perfect appearance,color and arthral function.Conclusion CDFI is a simple,macroscopic and atraumatic method for designing the axial pattern flap on lower limb,can provide more scientific and accurate evidence for preoperative determination of flap transplantation and is worthy of clinical application.10 refs,4 figs,2 tabs. 展开更多
关键词 Design of axial flaps with color doppler flow imaging technique for repairing deep wounds of heels
下载PDF
APPLICATION OF DOPPLER OPTICAL COHERENCE TOMOGRAPHY IN RHEOLOGICAL STUDIES:BLOOD FLOW AND VESSELS MECHANICAL PROPERTIES EVALUATION 被引量:1
14
作者 MARCO BONESI ANEURIN J.KENNERLEY +1 位作者 IGOR MEGLINSKI STEPHEN MATCHER 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2009年第4期431-440,共10页
Doppler Optical Coherence Tomography(DOCT)is a noninvasive optical diagnostic technique,which is well suited for the quantitative mapping of microflow velocity profiles and the analysis of flow-vessel interactions.The... Doppler Optical Coherence Tomography(DOCT)is a noninvasive optical diagnostic technique,which is well suited for the quantitative mapping of microflow velocity profiles and the analysis of flow-vessel interactions.The noninvasive imaging and quantitative analysis of blood flow in the complex-structured vascular bed is required in many biomedical applications,including those where the determination of mechanical properties of vessels or the knowledge of the mechanic interactions between the flow and the housing medium plays a key role.The change of microvessel wall elasticity could be a potential indicator of cardiovascular disease at the very early stage,whilst monitoring the blood flow dynamics and associated temporal and spatial variations in vessel’s wall shear stress could help predicting the possible rupture of atherosclerotic plaques.The results of feasibility studies of application of DOCT for the evaluation of mechanical properties of elastic vessel model are presented.The technique has also been applied for imaging of sub-cranial rat blood flow in vivo. 展开更多
关键词 Optical imaging optical coherence tomography doppler OCT blood flow elastic vessels mechanical properties.
下载PDF
Evaluation of Prognosis of Brain Function with Early Transcranial Color Doppler Ultrasound in Patients after Cardiopulmonary Resuscitation 被引量:1
15
作者 Hui Guo Zhangshun Shen +4 位作者 Ning Xu Qian Zhao Hongling Li Yangjuan Jia Jianguo Li 《World Journal of Cardiovascular Diseases》 2020年第9期658-665,共8页
<strong>Objective</strong><span style="font-family:;" "=""><span style="font-family:Verdana;"><strong>: </strong>To evaluate the clinical value of... <strong>Objective</strong><span style="font-family:;" "=""><span style="font-family:Verdana;"><strong>: </strong>To evaluate the clinical value of transcranial color Doppler ultrasound (TCCD) in assessing cerebral function after cardiopulmonary resuscitation (CPR). </span><b><span style="font-family:Verdana;">Methods</span></b><span style="font-family:Verdana;">: A prospective study was conducted in 52 patients with cardiac arrest treated by CPR from January 2018 to January 2020, and its clinical data were analyzed</span></span><span style="font-family:Verdana;">. </span><span style="font-family:;" "=""><span style="font-family:Verdana;">According to classification of cerebral performance category (CPC), 31 cases (CPC grade 1 - 2) were selected in the good prognosis group and 21 cases (CPC grade 3 - 5) in the poor prognosis group. The cerebral blood flow was measured by transcranial Doppler ultrasound (TCCD) 24 h after CPR, and the differences were compared between the two groups in stroke index, diastolic blood flow velocity (Vd), systolic peak blood flow velocity (Vs) and mean peak blood flow velocity (Vm). The ROC curve of cerebral blood flow after CPR was drawn to predict the prognosis of brain function. </span><b><span style="font-family:Verdana;">Results</span></b><span style="font-family:Verdana;">: The data showed that the pulsatility index of middle cerebral artery of the poor prognosis group decreased within 24 h</span></span><span style="font-family:Verdana;">;</span><span style="font-family:Verdana;">the difference between the two groups was statistically significant (p < 0.05);the Vd, Vs, Vm increased in the good prognosis group</span><span style="font-family:Verdana;">;</span><span style="font-family:;" "=""><span style="font-family:Verdana;">the difference between the two groups was statistically significant (p < 0.05). The ROC curve of cerebral blood flow after CPR was drawn to predict the prognosis of brain function, and the results showed that the area under the curve and the optimal critical value of cerebral blood flow were 0.731 and 5.69. The sensitivity and specificity were 67.3% and 79.1% respectively. </span><b><span style="font-family:Verdana;">Conclusion</span></b><span style="font-family:Verdana;">: The cerebral blood flow increase in the early stage of successful CPR is positively correlated with the prognosis of cerebral functional resuscitation. Monitoring intracranial blood flow after CPR by TCCD has clinical value to evaluate prognosis of brain function.</span></span> 展开更多
关键词 Cardiopulmonary Resuscitation (CPR) Transcranial color Bifunctional ultrasound (TCCD) Cerebral blood flow Prognosis of Brain Function
下载PDF
超声B-Flow联合外周血NLR、CRP对颈动脉粥样硬化斑块易损性的诊断效能研究
16
作者 李亮亮 《罕少疾病杂志》 2024年第4期21-23,共3页
目的探讨超声二维灰阶血流显像技术(B-Flow)联合外周血中性粒细胞与淋巴细胞比值(NLR)、C反应蛋白(CRP)诊断颈动脉粥样硬化(CAS)斑块易损性的价值。方法纳入2019年2月至2022年8月在天津市永久医院诊查的152例CAS患者为研究对象,均利用... 目的探讨超声二维灰阶血流显像技术(B-Flow)联合外周血中性粒细胞与淋巴细胞比值(NLR)、C反应蛋白(CRP)诊断颈动脉粥样硬化(CAS)斑块易损性的价值。方法纳入2019年2月至2022年8月在天津市永久医院诊查的152例CAS患者为研究对象,均利用颈动脉斑块超声B-Flow和数字减影血管造影(DSA)检查斑块性质,并检测外周血NLR、CRP水平,以DSA结果为“金标准”,将患者分为易损斑块组和稳定斑块组,统计超声B-Flow检查结果,比较两组外周血NLR、CRP水平,分析超声B-Flow、外周血NLR、CRP水平三者单独及联合诊断CAS斑块易损性的价值。结果DSA检查结果显示,152例CAS患者检出66例易损斑块,86例为稳定斑块;超声B-Flow检查出72例易损斑块,80例稳定斑块,以DSA检查结果作为“金标准”,超声B-Flow诊断易损斑块的灵敏度、特异度、准确度分别为84.85%、81.39%、82.89%;易损斑块组外周血NLR、CRP水平均高于稳定斑块组(P<0.05);超声B-Flow联合外周血NLR、CRP水平诊断CAS易损性斑块的灵敏度、特异度、曲线下面积(AUC)分别为98.48、81.39%、0.907,联合诊断的灵敏度高于单独诊断,AUC高于单独诊断(P<0.05),特异度与单独诊断相近。结论超声B-Flow、外周血NLR、CRP均对CAS斑块易损性具有一定的诊断效能,但三者联合诊断效能更好。 展开更多
关键词 颈动脉粥样硬化 超声二维灰阶血流显像技术 中性粒细胞 淋巴细胞 C反应蛋白 易损斑块
下载PDF
Value of Acceleration Flow in the Left Anterior Descending Coronary Artery for the Detection of Coronary Artery Stenosis by Transthoracic Coronary Color Doppler Echocardiography
17
作者 陈斌 邓又斌 +4 位作者 杨好意 阮燕菲 常青 毕小军 王红英 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第5期597-600,共4页
Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left... Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left anterior descending coronary arteries in 45 patients was detected by transthoratio color Doppler echocardiograph and multipoint pulse Doppler spectrums were recorded in the same segment. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was calculated. The ratio ≥1.5 was the cutoff value for the presence of localized acceleration flow. There were 23 patients with localized acceleration flow examined by eehoeardiography. Twenty of them were found to have luminal diameter stenosis (60%-98%) in the left anterior descending coronary arteries by coronary angiography and 3 patients were normal. There were 22 patients without localized acceleration flow examined by eehoeardiography. Eighteen of them had no or %60 stenosis. Four patients had serious stenosis (≥95%) or occluded segments in the left anterior descending coronary arteries on coronary angiography. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was significantly higher in patients with left anterior descending coronary artery stenosis than that in those without stenosis (1.9±0.3 vs 1.3±0.2, P〈0.01) and it correlated significantly with left anterior descending coronary artery stenosis (r=0.77, P〈0.01). The specificity by using the ratio≥1. 5 for stenosis detection was 85.7% (18/ 21), and the sensitivity was 83.3% (20/24). This study demonstrated that local blood flow velocity was increased in the resting stenotie left anterior descending coronary artery. Transthoraeie color Doppler eehoeardiography is a reliable noninvasive method to detect localized acceleration flow in the left anterior descending coronary artery stenosis and it is useful in the noninvasive diagnosis of stenosis in the left anterior descending coronary artery. 展开更多
关键词 ECHOCARDIOGRAPHY coronary artery STENOSIS color doppler flow imaging
下载PDF
COLOR FLOW IMAGING OF HEPATIC CARCINOMA
18
作者 Xu Zhizhang Wang Wenping(Department of Diagnostic Ultrasound,Zhongshan Hospital,Shanghai Medical University,Shanghai 200032) 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 1994年第1期45-50,共6页
Color flow imaging(CFI)ultrasound technique can discover the tumor vascularity and superimposed it to convontional B-mode ultrasonogram in real-time. The flow velocity on spectral Doppler sonogram can be measured by s... Color flow imaging(CFI)ultrasound technique can discover the tumor vascularity and superimposed it to convontional B-mode ultrasonogram in real-time. The flow velocity on spectral Doppler sonogram can be measured by setting the sample volume to any selected site.One hundred and thirty-six patients with solid hepatic space-occupied lesions had been admitted and 113 cases were confirmed by operation and pathology,23 patients were strongly suspected by hepatic angiography (HAA).Ninety nine patients with 109 nodules were finally diagnosed as hepatic cellular carcinoma(HCC).According to color flow distribution pattern,3 kinds of color configuation had been nominated.Tumor vascularity discovered by CFI,especially the arterial blood flow was easy to be recognized,and its emerge rate was quite different between HCC group(94.5%)and hemangioma(HCH)group(17.07%)(P<0.01).Spectral Doppler studies were also carried out in these cases and the detectability of arterial flow in HCC group(95.41%)was much higher than that to HCH group (21. 95%) (P<0. 005).Resistant index(RI)and pulsatile index(PI)could be used to differentiate HCC (>0. 50 and >0.80 respectively)from HCH (P<0.001 and P<0.001 respectively).Arterial-portal(A-P) shunt could also be detected by CFI and spectral Doppler(mostly its Vmax>0.6m/s).The detection rate of A-P shunt was 64% in HCC group,but no case could be detected in HCH group. 展开更多
关键词 Hepatic carcinoma color flow imaging(CFI) Spectral doppler sonogram Resistant index(RI) Pulsatile index(PI) Hepatic artery angiography(HAA).
下载PDF
Predicting Endometrium Receptivity with Parameters of Spiral Artery Blood Flow 被引量:12
19
作者 贡雪灏 李泉水 +1 位作者 张青萍 朱桂金 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第3期335-338,共4页
In order To evaluate whether the parameters of spiral artery blood flow, as measured by transvaginal color Doppler, may be used to assess endometrium receptivity prior to embryo transfer (ET), a retrospective study of... In order To evaluate whether the parameters of spiral artery blood flow, as measured by transvaginal color Doppler, may be used to assess endometrium receptivity prior to embryo transfer (ET), a retrospective study of 94 infertile women who had undergone ART treatments with different outcomes (pregnant or nonpregnant) was done. Subendometrial blood flow was evaluated. The resistance index (RI), systolic/diastolic ratio (S/D) and pulsatility index (PI) were significantly lower in those who achieved pregnancy as compared with those who did not: 0.62±0.04 vs 0.68±0.04 (P<0.001), 2.66±0.33 vs 3.19±0.39 (P<0.01) and 1.15±0.17 vs 1.34±0.22 (P<0.05), respectively. Furthermore, when RI>0.72, PI>1.6, and S/D>3.6, no pregnancy occurred. These data suggest that the parameters of spiral artery blood flow could be used as a new assay in predicting endometrial receptivity before ET. 展开更多
关键词 endometrium receptivity parameters of spiral artery blood flow INFERTILITY transvaginal color doppler
下载PDF
Diagnostic value of different color ultrasound diagnostic method in endometrial lesions 被引量:5
20
作者 Xiao-Lin Lin Dong-Sheng Zhang +2 位作者 Zhi-Ye Ju Xiu-Ming Li Yao-Zhu Zhang 《World Journal of Clinical Cases》 SCIE 2021年第19期5037-5045,共9页
BACKGROUND Endometrial lesions include endometrial cancer and inferior fibroids.Among them,endometrial cancer as a malignant tumor seriously endangers the life and health of patients.Ultrasonography is an important me... BACKGROUND Endometrial lesions include endometrial cancer and inferior fibroids.Among them,endometrial cancer as a malignant tumor seriously endangers the life and health of patients.Ultrasonography is an important means of diagnosing female reproductive system diseases,and it is of critical value for the early diagnosis of endometrial cancer.However,different ultrasound inspection programs have achieved different results.It is of great significance to choose a suitable inspection program.AIM To explore the diagnostic efficacy of different ultrasonic examination methods in clinical endometrial lesions.METHODS The 140 patients with endometrial lesions who were treated in our hospital from April 2018 to October 2019 were used as the research subjects.All patients underwent transvaginal color ultrasound and transabdominal color ultrasound.We compared the diagnostic coincidence and image display effects of the two different examination methods,and the endometrial thickness,blood flow,uterine effusion and resistance index of different diseases were observed by transvaginal color ultrasound.RESULTS The diagnostic coincidence rate of all types of diseases of transvaginal color ultrasound was significantly higher than that of transabdominal color ultrasound(P=0.001,0.005,0.001 and 0.001).In addition,the excellent and good rate of image display of transvaginal color ultrasound was higher than that of transabdominal color ultrasound(P=0.001).There were significant differences in endometrial thickness in patients with different types of endometrial lesions through the transvaginal color examination(P=0.001).The incidence rate of uterine effusion in patients with endometrial carcinoma was significantly higher than that in patients with other types of endometrial lesions(P=0.001),and the rate of the blood flow was the highest(P=0.001).The comparison of blood flow resistance index indicated that the blood flow resistance index in endometrial cancer patients was the lowest,which shows that the difference was statistically significant(P=0.001).CONCLUSION The overall diagnostic efficacy of transvaginal color ultrasound in the clinical diagnosis of endometrial lesions is better than that of transabdominal color ultrasound,which held higher diagnostic coincidence rate and image display effect.There were significant differences in the thickness of the endometrium and the blood flow in different types of lesions. 展开更多
关键词 Endometrial lesions Transvaginal color ultrasound Transabdominal color ultrasound Diagnostic conformity blood flow Resistance index
下载PDF
上一页 1 2 136 下一页 到第
使用帮助 返回顶部