期刊文献+
共找到6,713篇文章
< 1 2 250 >
每页显示 20 50 100
Investigation of lacrimal sac space-occupying lesions using color doppler ultrasound, computed tomography, and computed tomography dacryocystography
1
作者 Zhen-Bin Qian Bo Yu +3 位作者 Ye Yang Wei Fang Jian-Li Dong Li-Qing Wei 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1224-1230,共7页
AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:T... AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:This retrospective case series study included 21 patients with lacrimal sac SOLs who underwent lacrimal sac surgery between January 2018 and March 2022.The imaging features of CDU and CT or CT-DCG in these patients were extracted from the examination cloud system.The images were observed and analyzed.RESULTS:The detection rate of lacrimal SOLs between CDU(21/21,100%)and CT or CT-DCG(20/21,95.2%)had no statistically significant difference(P=1.0).CDU could detect the blood flow signals in all SOLs except mucocele and mucopeptide concretion.Among them,polyps had characteristic imaging changes on CDU and CT-DCG.The mucoceles and mucopeptide concretions had characteristic imaging changes on CDU,which could provide more information for differential diagnosis.CONCLUSION:The morphology and internal blood flow signals of lacrimal sac SOLs can be observed using CDU.CT or CT-DCG has advantages in observing structural damage around the lacrimal sac mass.Therefore,CDU may be used as a routine examination to exclude lacrimal sac SOLs before dacryocystorhinostomy in the absence of preoperative CT or CT-DCG. 展开更多
关键词 lacrimal sac computed tomography computed tomography dacryocystography color doppler ultrasound space-occupying lesions
下载PDF
Hemodynamic analysis of esophageal varices in patients with liver cirrhosis using color Doppler ultrasound 被引量:24
2
作者 Feng-Hua Li Jing Hao +2 位作者 Jian-Guo Xia Hong-Li Li Hua Fang 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第29期4560-4565,共6页
AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patien... AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patients with liver cirrhosis and portal hypertension. METHODS: One hundred and twenty cirrhotic patients with esophageal varices but without any previous bleeding were enrolled in the prospective study. During a 2-year observation period, 52 patients who had at least one episode of acute esophageal variceal hemorrhage constituted the bleeding group, and the remaining 68 patients without any previous hemorrhage constituted the non-bleeding group. All patients underwent endoscopy before or after color Doppler-ultrasonic examination, and images were interpreted independently by two endoscopists. The control group consisted of 30 healthy subjects, matched to the patient group in age and gender. Measurements of diameter, flow direction and flow velocity in the left gastric vein (LGV) and the portal vein (PV) were done in all patients and controls using color Doppler unit. After baseline measurements, 30 min after oral administration of 75 g glucose in 225 mL, changes of the diameter, flow velocity and direction in the PV and LGV were examined in 60 patients with esophageal varices and 15 healthy controls. RESULTS: The PV and LGV were detected successfully in 115 (96%) and 105 (88%) of 120 cirrhotic patients, respectively, and in 27 (90%) and 21 (70%) of 30 healthy controls, respectively. Among the 120 cirrhotic patients, 37 had F1, 59 had F2, and 24 had F3 grade varices. Compared with the healthy controls, cirrhotic group had a significantly lower velocity in the PV, a significantly greater diameter of the PV and LGV, and a higher velocity in the LGV. In the cirrhotic group, no difference in portal flow velocity and diameter were observed between patients with or without esophageal variceal bleeding (EVB). However, the diameter and blood flow velocity of the LGV were significantly higher for EVB (+) group compared with EVB (-) group (P〈0.01). Diameter of the LGV increased with enlarged size of varices. There were differences between F1 and F2, F1 and F3 varices, but no differences between F2 and F3 varices (P = 0.125). However, variceal bleeding was more frequent in patients with a diameter of LGV 〉6 mm. The flow velocity in the LGV of healthy controls was 8.70+1.91 cm/s (n = 21). In patients with liver cirrhosis, it was 10.3+2.1 cm/s (n = 12) when the flow was hepatopetal and 13.5+2.3 cm/s (n = 87) when it was hepatofugal. As the size of varices enlarged, hepatofugal flow velocity increased (P〈0.01) and was significantly different between patients with F1 and F2 varices and between patients with F2 and F3 varices. Variceal bleeding was more frequent in patients with a hepatofugal flow velocity 〉15 cm/s (32 of 52 patients, 61.5%). Within the bleeding group, the mean LGV blood flow velocity was 16.6+2.62 cm/s. No correlation was observed between the portal blood flow velocity and EVB. In all healthy controls, the flow direction in the LGV was hepatopetal, toward the PV. In patients with F1 varices, flow direction was hepatopetal in 10 patients, to-and-fro state in 3 patients, and hepatofugal in the remaining 18. The flow was hepatofugal in 91% patients with F2 and all F3 varices. Changes in diameter of the PV and LGV were not significant before and after ingestion of glucose (PV: 1.41+1.5 cm before and 1.46+1.6 cm after; LGV: 0.57+1.7 cm before and 0.60+1.5 cm after). Flow direction in the LGV was hepatopetal and to-and-fro in 16 patients and hepatofugal in 44 patients before ingestion of glucose. Flow direction changed to hepatofugal in 9 of 16 patients with hepatopetal and to-and-fro blood flow after ingestion of glucose. In 44 patients with hepatofugal blood flow in the LGV, a significant increase in hepatofugal flow velocity was observed in 38 of 44 patients (86%) with esophageal varices. There was a relationship between the percentage changes in flow velocity and the size of varices. Patients who responded excessively to food ingestion might have a high risk for bleeding. The changes of blood flow velocity in the LGV were greater than those in the PV (LGV: 28.3+26.1%, PV: 7.2+13.2%, P〈0.01), whereas no significant changes in the LGV occurred before and after ingestion of glucose in the control subjects. CONCLUSION: Hemodynamics of the PV is unrelated to the degree of endoscopic abnormalities in patients with liver cirrhosis. The most important combinations are endoscopic findings followed by the LGV hemodynamics. Duplex-Doppler ultrasonography has no value in the identification of patients with cirrhosis at risk of variceal bleeding. Hemodynamics of the LGV appears to be superior to those of the PV in predicting bleeding. 展开更多
关键词 HEMODYNAMICS Esophageal varices Liver cirrhosis color doppler ultrasound
下载PDF
Clinical Evaluation of Color Doppler Ultrasound in Selecting the Optimal Treatment Modality for Infantile Hemangioma 被引量:6
3
作者 MinLi JuanLiu +2 位作者 ValeskaMaya DanLuo Bingrong Zhou 《Chinese Medical Sciences Journal》 CAS CSCD 2017年第2期100-106,共7页
Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler u... Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler ultrasound guidance in choosing the optimal treatment modality. Methods Infantile patients who were clinical diagnosed as hemangiomas were randomly divided into group A, who had color Doppler ultrasound examinations before the treatment, and group B who had the treatment without ultrasound evaluation. Patients in the group A were assigned into subgroups according to the depth of lesion by sonography: group A-1 for those who had a lesion depth 〈1.2 mm, and took intense pulsed light therapy; group A-2 for those who had a lesion depth ≥1.2mm and 〈 3 mm, and took long pulse 1064 nm Nd:YAG laser therapy; group A-3 for those who had a lesion depth ≥3mm and 〈5 mm, and were treated by IPL combined with long pulse 1064 nm Nd:YAG laser treatment; Group A-4 for those who had a lesion depth ≥5 mm, and took lauromacrogol injection therapy. Patients in the group B took long pulse 1064 nm Nd:YAG laser treatment without preoperative ultrasound evaluation. The efficacy and adverse reactions of the treatments between the groups were evaluated and compared statistically. Results Totally 113 patients with 128 skin lesions were enrolled in this study, 85 in the group A (mean age 6.8±7.9 months) and 28 in the group B (mean age 6.9±9.9 months). The mean depth of hemangioma was 3.3±1.1 mm in the group A, ranging from 0.5-7.8 mm, with 0.8±0.4 mm, 2.2±0.4 mm, 4.2±0.6 mm and 6.2±0.7 mm in group A1, A2, A3 and A4, respectively. The cure rates and effective rates in the group A were significantly higher than those in the group B (cure rates: 64.5% vs 56.3%, U=3.378, P=0.045; effective rates: 89.5% vs 78.1%, U=4.163, P=0.041). The adverse effect rates of the group A (vesicle 20.0%, pigmentation 46.9%, scarring 17.7%) were lower than those of the group B (vesicle 21.9%, pigmentation 60.4%, scarring 25.0%). Incidences of pigmentation and scarring were statistically significantly different (U=3.884, P=0.034, and U=4.016, P=0.032 respectively) between the two groups. Conclusion With the guidance of color Doppler ultrasound, the efficacy and safety of long pulse 1064 nmNd:YAG laser, intense pulsed light, and lauromacrogol injection in the treatment of infantile hemangioma have better outcomes compared to laser treatment alone without preoperative ultrasound examination. 展开更多
关键词 color doppler ultrasound infantile hemangioma Nd:YAG laser intense pulsed light LAUROMACROGOL
下载PDF
FEASIBILITY STUDY OF AN ULTRASOUND CONTRAST AGENT(LEVOVIST) IN COLOR DOPPLER IMAGING OF LIVER NEOPLASMS 被引量:6
4
作者 姜玉新 戴晴 +4 位作者 刘吉斌 张缙熙 常欣 蔡胜 谭莉 《Chinese Medical Sciences Journal》 CAS CSCD 1999年第3期167-169,共3页
The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tu... The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tumors were enrolled in this study.After intravenous administration of levovist,the color Doppler signals of normal hepatic vessels were enhanced.In various hepatic tumors,the different patterns of tumor vascularity were observed,which had not been demonstrated in conventional non contrast color Doppler imaging.In 11 of 16 patients with hepatocarcinoma,additional color Doppler signals were observed in the central part of the tumors.On the contrary,3 patients with metastatic liver lesions the enhanced color Doppler signals appear only at the peripheral of tumors.A typical rim like color enhancement was seen in 2 of the 3 cases.In six patients with hepatic hemangiomas contrast enhanced color Doppler imaging demonstrated the blood vessels at the margin of the neoplasms.Contrast enhanced color Doppler imaging improves the visualization of the hepatic neoplasm vascularity.This technique holds great promise for detecting small liver tumors and differentiating hepatic neoplasms. 展开更多
关键词 ultrasound contrast agent color doppler imaging liver neoplasms
下载PDF
Hemodynamic Changes on Color Doppler Flow Imaging and Intravenous Contrast-enhanced Ultrasound for Assessing Transplanted Liver and Early Diagnosis of Complications 被引量:1
5
作者 黄道中 陈云超 +1 位作者 李开艳 张青萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期284-286,共3页
The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discu... The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS. 展开更多
关键词 color doppler flow imaging liver transplantation HEMODYNAMICS postoperative complications intravenous contrast-enhanced ultrasound
下载PDF
The Diagnostic Value of Color Doppler Ultrasound and Grey Scale Sonography in Predicting the Malignancy of Thyroid Nodules 被引量:2
6
作者 Hamad Elniel H. Eltyib Sameh A. Aborizk +2 位作者 Hanan A. Albalawi Afaf S. Almotairi Arwa H. Aidrus 《Open Journal of Radiology》 2020年第4期215-222,共8页
Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. ... Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. Out of 120 patients, 106 (88.3%) female and 14 (11.7%) male patients. Out of 106 female patients, 64 (91.45) had benign and 42 had malignant thyroid nodules. Out of 14 (11.7) male patients, 6 had benign and 8 had malignant thyroid nodules. The youngest patient in our study was 31 years and the oldest patient was 76 years. The common range of patients age was ≥ 60 years and consisting of twenty (28.6%) benign thyroid nodules and fourteen (28%) malignant thyroid nodules. The majority of patients’ age group with malignant thyroid nodules were between 50 - 60 years and consisting of twenty (40%) malignant nodules. In our study, according to the result of gray scale and color Doppler ultrasonography, hypo-echogenicity, solid echo structure, micro-calcification and intra-nodular vascularity were the significant characteristics of malignancy in nodules with sensitivity (72%, 74%, 48% and 88% respectively), specificity (66%, 63%, 94% and 69% respectively), PPV (60%, 59%, 86% and 67% respectively) and NPV (77%, 77%, 72% and 89% respectively). 展开更多
关键词 ultrasound Thyroid Nodules MALIGNANT color doppler Fine Needle Aspiration
下载PDF
Assessment of Uterine Receptivity by Endometrial and Subendometrial Blood Flows Measured by Vaginal Color Doppler Ultrasound in Women Undergoing IVF Treatment 被引量:1
7
作者 Min-zhi GAO Xiao-ming ZHAO +3 位作者 Wen-ying LI Gui-mei LIU Xiao-feng JIA Hui-qin ZHANG 《Journal of Reproduction and Contraception》 CAS 2007年第3期205-212,共8页
Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infert... Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infertile patients undergoing the first IVF/ICSI-ET cycle were recruited. Three groups were divided according to a color Doppler ultrasound examination performed on the day of hCG injection. Group A, endometrial and subendometrial blood flows were 2 branches and below; group B, endometrial and subendometrial blood flows were between 3 and 4 branches; group C, endometrial and subendometrial blood flows were 5 branches and above. Patients were transferred 1-3 embryos each. Demographic data, ovarian responses, endometrial thickness, PI, RI, development of embryo and IVF result among groups were compared. Results Demographic data, ovarian responses, endometrial thickness, PI, RI and development of embryo among groups have no significant difference. The pregnancy rate of group A was significantly lower than that of group B (P〈0.05) and group C (P〈0.01). The implantation rate of group A was significantly lower than than of group C (P〈0.01). There was no significant difference of the rate of pregnancy and implantation between group B and group C (P〉0.05). Conclusion Endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound is a good predicator of pregnancy during IVF treatment. A good endometrial and subendometrial blood flows is benefit for the result of IVF. 展开更多
关键词 endometrial and subendometrial blood flows endometrial receptivity in vitro fertilization-embryo transfer (IVF) color doppler ultrasound
下载PDF
Early warning study of color doppler ultrasound in children with thyroid nodules and thyroid cancer 被引量:1
8
作者 Li Yang Wen-Qi Ma +1 位作者 Bai-Ling Liu Qi Zhou 《Journal of Hainan Medical University》 2019年第9期66-69,共4页
Objective: To study the diagnostic value of color doppler ultrasound in children with thyroid nodules and thyroid cancer. Methods: A total of sixty children with thyroid nodules treated in our hospital from March 2017... Objective: To study the diagnostic value of color doppler ultrasound in children with thyroid nodules and thyroid cancer. Methods: A total of sixty children with thyroid nodules treated in our hospital from March 2017 to March 2018 were selected for study. All patients underwent color Doppler ultrasound diagnosis. According to the diagnostic data, benign thyroid nodules and thyroid cancer were analyzed. The nodule nature was grouped into benign nodules group and malignant nodules group. The aspect ratio and boundary of the two groups were compared in blurring, calcification, blood flow signal classification, etc. Results: A total of 95 nodules were diagnosed by color doppler ultrasonography in 60 cases of thyroid nodules. 49 cases were benign nodules. There were 80 nodules, accounting for 82.11%, 11 cases of thyroid cancer, and 15 nodules. Accounted for 15.79%. Biopsy puncture pathology confirmed 77 benign nodules and 18 malignant nodules. The pathological results were gold standard. The specificity of color Doppler ultrasound was 90%, the sensitivity was 66.67%, and the accuracy of ultrasound diagnosis was 86.32%.The two nodules were statistically significant in terms of boundary, aspect ratio, calcification, echo, and resistance index (P<0.05), but the end-diastolic blood flow velocity (EDV) and peak systolic blood flow velocity ( There was no statistical difference between the PSV levels (P>0.05).Conclusion: Color Doppler ultrasound has the advantages of simple operation, high accuracy, non-invasive and painless, and reproducible detection. The high-frequency probe can clearly display changes such as minute lesions, blood flow signals, echoes, calcifications, etc., and can diagnose thyroid cancer in time. It provides a favorable basis for clinical treatment and has important clinical warning value, especially for children with thyroid examination. 展开更多
关键词 THYROID NODULES color doppler ultrasound PEDIATRIC THYROID cancer Early WARNING
下载PDF
Measurement of Liver Size and Intrahepatic Blood Flow of Red-eared Turtles by Color Doppler Ultrasound
9
作者 Cheng Yu Xie Fuqiang 《Animal Husbandry and Feed Science》 CAS 2015年第4期246-248,共3页
In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The res... In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The results showed that the fight hepatic lobe could be scanned through the right carotid anterior acoustic win- dow, and the left hepatic lobe could be scanned through the left carotid anterior acoustic window, but the vision would be obstructed by the air in trachea. The liver could also be scanned through the left femoral anterior acoustic window and the fight femoral anterior acoustic window when filling of bladder was good. The correla- tion regression analysis suggested that estimated values of liver showed no linear relationship with weight, the longest back curve and the widest back curve. Through the study, the normal indicators for ultrasound examination of red-eared turtle liver were established, in order to provide a reference for examination of turtle liver. 展开更多
关键词 Red-eared turtle color doppler ultrasound LIVER Blood flow
下载PDF
Diagnosis of parathyroid tumor using Color Doppler ultrasound
10
作者 Qiuling Shi Haibo Fan Qi Lin Zhanghong Wei Ying Wu 《International English Education Research》 2014年第2期74-77,共4页
What the liver organized examining to the diagnosis of liver disease, course of disease alive is appraised and treated and taught fruits by stages, judge respects such as the prognosis, etc. play an important role. In... What the liver organized examining to the diagnosis of liver disease, course of disease alive is appraised and treated and taught fruits by stages, judge respects such as the prognosis, etc. play an important role. In recent years, supersound lead down, examine marksmanship walk liver puncture the technology that examines living to employ at clinic extensively becoming while being living. In order to appraise its application effect, specially carry on reviewing summary analysis. 展开更多
关键词 color doppler ultrasound DIAGNOSIS TUMOUR
下载PDF
Application value of color Doppler ultrasound in the detection of hemodynamic change in patients with chronic kidney disease
11
作者 Qiu-Hong Zhong Jia-Fu Lan +3 位作者 Peng-Wei Guo Mei-Ying Huang Fei-Fan Huang Xu Lin 《Journal of Hainan Medical University》 2017年第3期116-119,共4页
Objective:To explore the application value of color Doppler ultrasound in the detection of hemodynamic change in patients with chronic kidney disease (CKD). Methods:A total of 720 patients with CKD who were admitted i... Objective:To explore the application value of color Doppler ultrasound in the detection of hemodynamic change in patients with chronic kidney disease (CKD). Methods:A total of 720 patients with CKD who were admitted in our hospital from June, 2014 to May, 2016 were included in the study and divided into CKD2 group (n=242), CKD3 group (n=230), and CKD4 group (n=248) according to K/DOQI guideline. Meanwhile, 100 healthy volunteers were served as the control group. The renal parenchymal thickness, length, width, thickness, and hemodynamics by the two-dimensional ultrasound and color Doppler ultrasound in the four groups were observed. Results:The renal parenchymal thickness, length, width, and thickness in CKD2 group were reduced when compared with the control group, but the difference was not statistically significant (P>0.05);the above indicators in CKD3 group were significantly lower than those in the control group and CKD2 group (P<0.001);and the comparison of the above indicators between CKD4 group and other three groups was statistically significant (P<0.001). The comparison of hemodynamic parameters between CKD2 group and the control group was not statistically significant (P>0.05). The various hemodynamic parameters of Vs and Vd in CKD3 group were significantly lower than those in the control group and CKD2 group (P<0.001), while the various indicators of RI were significantly higher than those in the control group and CKD2 group (P<0.001). The various hemodynamic parameters of Vs and Vd in CKD4 group were significantly lower than those in the other three groups (P<0.001), while the various indicators of RI were significantly higher than those in the other three groups (P<0.001). Conclusions:Application of color Doppler ultrasound in detection of the hemodynamic change in patients with CKD can provide a reliable evidence for the disease diagnosis, condition monitoring, and prognosis evaluation, with an important application value. 展开更多
关键词 color doppler ultrasound Chronic KIDNEY disease HEMODYNAMICS APPLICATION VALUE
下载PDF
Color Doppler ultrasound evaluation of asphyxial neonatal left ventricular function and its correlation with target organ damage
12
作者 Cheng-Cai Chen Li-Zhen Li +1 位作者 Qi-Sheng Lu Yan-Ling Lang 《Journal of Hainan Medical University》 2017年第1期147-150,共4页
Objective:To study the color Doppler ultrasound parameters of asphyxial neonatal left ventricular function and the correlation with target organ damage.Methods: Normal neonates, mildly asphyxial neonates and severely ... Objective:To study the color Doppler ultrasound parameters of asphyxial neonatal left ventricular function and the correlation with target organ damage.Methods: Normal neonates, mildly asphyxial neonates and severely asphyxial neonates born in our hospital between January 2014 and December 2015 were selected as the control group (n = 46), mild asphyxia group (n= 37) and severe asphyxia group (n = 23) respectively. On the 1st day after birth, color Doppler ultrasound was used to evaluate left ventricular function, and serum was collected to determine myocardial tissue injury, brain tissue injury and brain tissue metabolism indexes. Results: Color Doppler ultrasound parameters cardiac output (CO), ejection fraction (EF) and left ventricular fraction shortening (FS) as well as serum folate and vitamin B12 content of mild asphyxia group and severe asphyxia group were significantly lower than those of control group (P<0.05) while serum creatine kinase isoenzyme (CK-MB), troponin I (cTnI), troponin T (cTnT), S100B, neuron-specific enolase (NSE), creatine kinase BB (CK-BB), glycogen phosphorylase BB (GPBB), and homocysteine (Hcy) content were significantly higher than those of control group (P<0.05);CO, FS and EF as well as serum folate and vitamin B12 content of severe asphyxia group were significantly lower than those of mild asphyxia group (P<0.05) while serum CK-MB, cTnT, cTnI, S100B, NSE, CK-BB, GPBB and Hcy content were significantly higher than those of mild asphyxia group (P<0.05).Conclusions:Color Doppler ultrasound can accurately assess asphyxial neonatal left ventricular function damage degree and is closely related to myocardial tissue injury and brain tissue injury degree. 展开更多
关键词 NEONATAL ASPHYXIA color doppler ultrasound MYOCARDIAL INJURY BRAIN INJURY
下载PDF
Use of Color Doppler Ultrasound for the Diagnosis of Subarachnoid Hemorrhage in Asymptomatic Full-Term Neonate:A Case Report
13
作者 Helio A.Guimaraes Filho Janett J.Liberalino +3 位作者 Ana T.P.Mendonca Carlos V.S.B.Leite Filho Leonardo F.Felipe Carlos F.Melo Júnior 《International Journal of Clinical Medicine》 2012年第2期151-153,共3页
Cerebral hemorrhages are fairly common in full-term neonates with no history of traumatic birth, mostly limited, and with benign evolution. We report a case of a full-term neonate from vaginal birth with caput succeda... Cerebral hemorrhages are fairly common in full-term neonates with no history of traumatic birth, mostly limited, and with benign evolution. We report a case of a full-term neonate from vaginal birth with caput succedaneum in the right parietal area. The neonate underwent cranial ultrasonography and color Doppler which showed extra-axial blood effusion. Color Doppler showed vessels crossing the collection area, which allowed the diagnosis of subarachnoid hematoma. 展开更多
关键词 Cerebral Hemorrhage Subarachnoid Hematoma Cranial ultrasound color doppler
下载PDF
Measurements Of Cerebral Blood Flow in Postasphyxiated Newborns by Color Doppler Imaging(CDI) 被引量:7
14
作者 常立文 汪元芳 刘婉君 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1996年第4期249-252,共4页
Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the... Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the anterior, middle and posterior cerebral arteries were studied. The results showed evidently lower systolic amplitude in patients than that in normal subjects. End diastolic amplitude was zero in part of vessels, and values of bloed flow variables were all lower in day 1 of the life as compared with the control groups. Frequency spectrum recovered to normal patterns in 9 survived infants in day 2. but blood flow variables recovered to normal by day 7. Values of resistance index (RI) rose to 1 in some vessels of moderate hypoxic ischemic encephalopathy (HIE) infants and stayed at 1 in the severe HIE infants. It is concluded that low CBF plays a key role in brain damage of post-asphyxiated newborns and RI may be an important parameter in the evaluation prognosis. 展开更多
关键词 asphyxiated newborns cerebral blood flow ultrasound imaging color doppler
下载PDF
Color Doppler ultrasonographic examination on the relationship between the gallbladder bed and major branch of the middle hepatic vein 被引量:3
15
作者 Wei-Zhong Zhang, Jie Shen, Jue-Xing Xie and Hong Zhu Taizhou, China Departments of Surgery and Ultrasonography , Taizhou First People’s Hospital, Taizhou 318020, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2005年第2期299-301,共3页
BACKGROUND: There is a controversy about the risk of injury to the branch of the middle hepatic vein during lapa- roscopic cholecystectomy. This study was conducted to further investigate the relationship between the ... BACKGROUND: There is a controversy about the risk of injury to the branch of the middle hepatic vein during lapa- roscopic cholecystectomy. This study was conducted to further investigate the relationship between the gallbladder bed and the branch of the middle hepatic vein. METHODS: Color Doppler ultrasound was used to exa- mine the anatomical relationship between the gallbladder bed and the branches of the middle hepatic vein in 143 healthy volunteers. RESULTS: Not all the middle hepatic vein extended close to the gallbladder bed, the branches and gallbladder beds in 23 subjects were not in the same plane during ultrasound scanning. In 21 of the 143 subjects the branch of the middle hepatic vein was completely adherent to the gallbladder bed with a diameter ranging from 1.2 mm to 3.6 mm. In 10 subjects the branches of the middle hepatic vein traversed approximately 1.0 mm from the gallbladder bed with a dia- meter ranging from 1.6 mm to 3.0 mm. CONCLUSIONS: In most subjects the branch of the middle hepatic vein and the gallbladder bed are well separated. Only patients with large branches of the middle hepatic vein close to the gallbladder bed are at risk of hemorrhage during laparoscopic cholecystectomy. 展开更多
关键词 laparoscopic cholecystectomy color doppler ultrasound hepatic vein
下载PDF
Correlation Study of Color Doppler Examination of Deep Veins of Both Lower Extremities Combined with Fibrinolysis System in Hypertension during Pregnancy 被引量:4
16
作者 Chundong Qiu Haiyan Chen +3 位作者 Xiaohua Huang Xiaoling Kong Chong Liang Chunhong Qiu 《Open Journal of Obstetrics and Gynecology》 2020年第8期981-989,共9页
<strong>Objective</strong><span style="font-family:Verdana;"><strong>:</strong></span><span style="font-family:Verdana;"> To investigate the correlation be... <strong>Objective</strong><span style="font-family:Verdana;"><strong>:</strong></span><span style="font-family:Verdana;"> To investigate the correlation between deep static color Doppler ultrasound of both lower extremities combined with fibrinolytic system detection in pregnancy-induced hypertension.</span><span style="font-family:""> </span><b><span style="font-family:Verdana;">Methods</span></b><b><span style="font-family:Verdana;">:</span></b><span style="font-family:Verdana;"> A total of 70 normal pregnant women, 70 pregnant women with hypertension during pregnancy, and 50 healthy non-pregnant women in the same period were selected as the research objects. The deep veins of both lower limbs were examined by Rili Erlangshen’s color Doppler ultrasound diagnostic instrument (CDU),</span><span style="font-family:""> </span><span style="font-family:""><span style="font-family:Verdana;">and the </span><span style="font-family:Verdana;">fibrinolysis system was tested by enzyme-linked immunosorbent assay (ELISA) </span><span style="font-family:Verdana;">method and </span><a name="OLE_LINK12"></a><span style="font-family:Verdana;">automatic hemagglutination analyzer.</span><b><span style="font-family:Verdana;"> Results</span></b></span><b><span style="font-family:Verdana;">:</span></b><b><span style="font-family:""> </span></b><span style="font-family:Verdana;">Compared with the non-pregnant group, the inner diameters of the left/right femoral vein (CFV) and popliteal vein (POV) in the normal pregnancy group and the pregnancy-induced hypertension group were significantly widened, and the peak blood flow spectrum was significantly reduced. The difference was statistically significant (P < 0.01);FIB, PLG, t-PA, PAI, D-Dimer were significantly increased, the difference was statistically significant (P < 0.01);Compared with the normal pregnancy group, the inner diameter of the left/right femoral vein (CFV) in the hypertensive pregnancy group was significantly wider than that in the normal pregnancy group, and the peak value of the left/right POV blood flow spectrum was significantly lower than that in the normal pregnancy group,</span><span style="font-family:""> </span><span style="font-family:Verdana;">the difference w</span><span style="font-family:Verdana;">as</span><span style="font-family:Verdana;"> statistically significant (P < 0.01)</span><span style="font-family:Verdana;">,</span><span style="font-family:""> <span style="font-family:Verdana;">while the left/right popliteal vein (POV) inner diameter, left/right CFV blood flow peak value did not change significantly from the normal pregnancy</span><span style="font-family:Verdana;"> grou</span></span><span style="font-family:Verdana;">p, </span><span style="font-family:Verdana;">and the difference was not statistically significant (P > 0.05);FIB, PLG, PAI, D-Dimer of the hypertensive disease group during pregnancy significantly increased, the difference was statistically significant (P < 0.01), while t-PA was not statistically significant (P > 0.05).</span><span style="font-family:""> </span><b><span style="font-family:Verdana;">Conclusion</span></b><b><span style="font-family:Verdana;">:</span></b><b><span style="font-family:""> </span></b><span style="font-family:Verdana;">Normal pregnant women have a hypercoagulable state compared with healthy non-pregnant women, and pregnant women with hypertension during pregnancy are more likely to be in a pre-thrombotic state than pregnant women with normal pregnancy. Deep vein CDU examination of both lower extremities combined with blood fibrinolysis monitoring is of great value in the prevention and treatment of hypertension during pregnancy.</span> 展开更多
关键词 Hypertension during Pregnancy Prothrombotic State color doppler ultrasound Fibrinolysis Index
下载PDF
Paper Clinical Value of Color Doppler Ultrasonography in Diagnosis of Lower Extremity Arterial Disease of Diabetes Patients 被引量:2
17
作者 Jianyu Zhang Haijiao Mao 《Journal of Biosciences and Medicines》 2020年第6期209-214,共6页
<div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. &l... <div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. <strong>Methods: </strong>48 patients with diabetic lower extremity vascular disease admitted in our hos-pital from September 2018 to September 2019 were included in the study and divided into the observation group, and another 48 patients with the same period of health examination in our hospital were included in the study and divided into the control group. Both groups used color Doppler ultrasound to detect the blood flow of lower extremity vessels. The incidence of blood flow, vascular diameter and stenosis, occlusion and arteriosclerosis of the lower extremity were observed. <strong>Results:</strong> The blood flow and vascular di-ameter of the lower extremity in the observation group were significantly lower than those in the control group (p < 0.05). The incidence of vascular stenosis, vascular occlusion, thrombus, intimal thickening and plaque in the observation group was 85.42%, 22.92%, 10.42% and 93.75% respectively, which was significantly higher than that in the control group was 10.42%, 0.00%, 0.00% and 14.58% (p < 0.05). The incidence of lower extremity vascular lesions in the observation group was significantly higher than that in the control group (p < 0.05). <strong>Conclusion:</strong> Color Doppler ultrasound is of high diagnostic value in the diagnosis of diabetic lower extremity vascular diseases, and can be used to determine the blood flow of the lower extremity and the inner diameter of popliteal artery, thigh artery, dorsalis pedis artery and so on. At the same time, it can also clearly show the specific situation of vascular occlusion, arteriosclerosis and thrombosis, which is of great signif-icance for the prevention and diagnosis of lower extremity vascular lesions, and can provide the basis for the treatment of lower extremity vascular lesions. </div> 展开更多
关键词 Super color doppler ultrasound Diabetic Complications Lower Extremity Vascular Disease Diagnostic Value
下载PDF
Role of color Doppler flow imaging in applicable anatomy of spleen vessels
18
作者 Wei-Li Xu Suo-Lin Li +2 位作者 Yan Wang Meng Li Ai-Guo Niu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第5期607-611,共5页
AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic ... AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic splenectomy (LS) for various hematopathies and autoimmune diseases were randomly selected from April 2005 to May 2008. Anatomic types of spleen pedicle, adjacent relations between spleen vessels and pancreas, diameters of spleen artery and vein were detected and recorded by preoperative CDFI. Different operative procedures were performed according to different anatomic frameworks. The parameters were recorded by telerecording during LS and compared with those by preoperative CDFI using Chi-square test. RESULTS: Two anatomic types of spleen pedicle and four different adjacent relations between spleen vessels and pancreas were detected by CDFI. The diameters of spleen artery and vein detected by CDFI were 0.46 ± 0.09 cm and 0.85 ± 0.35 cm, respectively. There was no statistical difference between the parameters recorded by CDFI and by telerecording (X^2 = 0.250, 0.677, P 〉 0.05). LS was successfully performed following the anatomic information provided by preoperative CDFI.CONCLUSION: Different anatomic frameworks of spleen vessels can be provided by preoperative CDFI, which instructs micro-invasive operation of spleen and increase the safety of operation. 展开更多
关键词 ultrasound color doppler imaging SPLEEN ANATOMY Laparoscopic operation
下载PDF
超声CDFI联合RT-SWE鉴别诊断乳腺癌与乳腺良性结节效果 被引量:9
19
作者 许寿星 姜美娟 +2 位作者 吴晓瑾 何慧灵 陈剑 《中国计划生育学杂志》 2023年第8期1981-1986,共6页
目的:分析高频彩色多普勒超声(CDFI)联合实时剪切波弹性成像(RT-SWE)在乳腺癌与乳腺良性结节中的鉴别诊断价值。方法:选取2019年1月-2021年12月在本院收治的乳腺肿瘤患者118例,根据病理结果分为乳腺癌组(64例)和乳腺良性结节组(54例)。... 目的:分析高频彩色多普勒超声(CDFI)联合实时剪切波弹性成像(RT-SWE)在乳腺癌与乳腺良性结节中的鉴别诊断价值。方法:选取2019年1月-2021年12月在本院收治的乳腺肿瘤患者118例,根据病理结果分为乳腺癌组(64例)和乳腺良性结节组(54例)。两组均行CDFI及RT-SWE检查,比较两组CDFI检查下乳腺影像报告和数据系统(BI-RADS)分级、超声征象以及RT-SWE检查下弹性模量值,分析CDFI、RT-SWE单独及联合检查鉴别乳腺癌与乳腺良性结节的符合率,根据受试者工作特征(ROC)曲线分析各指标检查对乳腺癌与乳腺良性结节鉴别诊断价值。结果:乳腺良性结节组CDFI检查下BI-RADS分级高于乳腺癌组,存在后方衰减、纵横比≥1、低或极低内部回声、边缘不规则、存在微钙化、实性内部结构占比均低于乳腺癌组,RT-SWE检查下平均弹性模量值(Emean)、最大弹性模量值(Emax)、最小弹性模量值(Emin)值均低于乳腺癌组(均P<0.05);对乳腺癌及乳腺良性结节的阳性与阴性预测率,CDFI分别为80.0%、77.4%,RT-SWE分别为87.3%、83.6%,二者联合分别为93.9%、96.2%;CDFI、RT-SWE及二者联合检查诊断乳腺癌及乳腺良性结节的曲线下面积分别为0.786、0.849、0.913。结论:CDFI和RT-SWE联合检查对乳腺肿瘤良恶性鉴别诊断有较高临床参考价值。 展开更多
关键词 乳腺癌 乳腺良性结节 高频彩色多普勒超声 实时剪切波弹性成像 鉴别诊断
下载PDF
Application and prospects of AI-based radiomics in ultrasound diagnosis
20
作者 Haoyan Zhang Zheling Meng +2 位作者 Jinyu Ru Yaqing Meng Kun Wang 《Visual Computing for Industry,Biomedicine,and Art》 EI 2023年第1期288-303,共16页
Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high tempora... Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis. 展开更多
关键词 Radiomics ultrasound imaging Artificial intelligence Deep learning B-mode ultrasound color doppler flow imaging ultrasound elastography Contrast-enhanced ultrasound Multimodal ultrasound
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部