Ultra-high molecular weight polyethylene(UHMWPE)fiber composite has been extensively used to construct lightweight protective structures against ballistic impacts,yet little is known about its performance when subject...Ultra-high molecular weight polyethylene(UHMWPE)fiber composite has been extensively used to construct lightweight protective structures against ballistic impacts,yet little is known about its performance when subjected to combined blast and fragment impacts.Built upon a recently developed laboratory-scale experimental technique to generate simulated combined loading through the impact of a fragment-foam composite projectile launched from a light gas gun,the dynamic responses of fullyclamped UHMWPE plates subjected to combined loading were characterized experimentally,with corresponding deformation and failure modes compared with those measured with simulated blast loading alone.Subsequently,to explore the underlying physical mechanisms,three-dimensional(3D)numerical simulations with the method of finite elements(FE)were systematically carried out.Numerical predictions compared favorably well with experimental measurements,thus validating the feasibility of the established FE model.Relative to the case of blast loading alone,combined blast and fragment loading led to larger maximum deflections of clamped UHMWPE plates.The position of the FSP in the foam sabot affected significantly the performance of a UHMWPE target,either enhancing or decreasing its ballistic resistance.When the blast loading and fragment impact arrived simultaneously at the target,its ballistic resistance was superior to that achieved when subjected to fragment impact alone,and benefited from the accelerated movement of the target due to simultaneous blast loading.展开更多
Dynamic load on anchoring structures(AS)within deep roadways can result in cumulative damage and failure.This study develops an experimental device designed to test AS under triaxial loads.The device enables the inves...Dynamic load on anchoring structures(AS)within deep roadways can result in cumulative damage and failure.This study develops an experimental device designed to test AS under triaxial loads.The device enables the investigation of the mechanical response,failure mode,instability assessment criteria,and anchorage effect of AS subjected to combined cyclic dynamic-static triaxial stress paths.The results show that the peak bearing strength is positively correlated with the anchoring matrix strength,anchorage length,and edgewise compressive strength.The bearing capacity decreases significantly when the anchorage direction is severely inclined.The free face failure modes are typically transverse cracking,concave fracturing,V-shaped slipping and detachment,and spallation detachment.Besides,when the anchoring matrix strength and the anchorage length decrease while the edgewise compressive strength,loading rate,and anchorage inclination angle increase,the failure intensity rises.Instability is determined by a negative tangent modulus of the displacement-strength curve or the continued deformation increase against the general downward trend.Under cyclic loads,the driving force that breaks the rock mass along the normal vector and the rigidity of the AS are the two factors that determine roadway stability.Finally,a control measure for surrounding rock stability is proposed to reduce the internal driving force via a pressure relief method and improve the rigidity of the AS by full-length anchorage and grouting modification.展开更多
In this study,an iterative-based three-dimensional finite element lower bound in association with the second-order cone programming method is adopted to evaluate the limit load of a single pile embedded in cross-aniso...In this study,an iterative-based three-dimensional finite element lower bound in association with the second-order cone programming method is adopted to evaluate the limit load of a single pile embedded in cross-anisotropic soils under general loading condition.The lower bound solutions of the pile embedded in an anisotropic soil deposit can be found by formulating the element equilibrium,equilibrium of shear and normal stresses along discontinuities,boundary conditions,yield function,and optimizing the objective function through the second-order cone programming method in conjunction with an iterative-based update procedure.A general loading condition is considered to profile the expansion of the safe load in the vertical-horizontal-moment(V-H-M)space.The results of this study are compared and validated against three different cases including an isotropic lateral loading,anisotropic end bearing capacity,and a pile embedded in an isotropic soil deposit under general loading condition.A parametric study is conducted to evaluate the impact of different influencing factors.It was found that the effect of anisotropy on the variation of lateral limit load of a single pile is more pronounced than the corresponding vertical and bending moment limit loads,whereas the interface properties have more significant effects on the vertical and bending moment limit loads in comparison to the lateral limit load.展开更多
This paper presents two kinematic failure mechanisms of threc-dimensional rectangular footing resting on homogeneous undrained clay foundation under uniaxial vertical loading and uniaxial moment loading. The failure m...This paper presents two kinematic failure mechanisms of threc-dimensional rectangular footing resting on homogeneous undrained clay foundation under uniaxial vertical loading and uniaxial moment loading. The failure mechanism under vertical loading comprises a plane strain Prandti-type mechanism over the central part of the longer side, and the size of the mechanism gradually reduces at the ends of the longer side and over the shorter side as the corner of rectangular footing is being approached where the direction of soil motion remains normal to each corresponding side respectively. The failure mechanism under moment loading comprises a plane strain scoop sliding mechanism over the central part of the longer side, and the radius of scoop sliding mechanism increases linearly at the ends of the longer side. On the basis of the kinematic failure mechanisms mentioned above, the vertical ultimate bearing capacity and the ultimate bearing capacity against moment or moment ultimate bearing capacity are obtained by use of upper bound limit analysis theory. At the same time, numerical analysis results, Skempton' s results and Salgado et al. 's results are compared with this upper bound solution. It shows that the presented failure mechanisms and plastic limit analysis predictions are validated. In order to investigate the behaviors of undrained clay foundation beneath the rectangular footing subjected to the combined loadings, numerical analysis is adopted by virtue of the general-purpose FEM software ABAQUS, where the clay is assumed to obey the Mohr-Coulomb yielding criterion. The failure envelope and the ultimate bearing capacity are achieved by the numerical analysis results with the varying aspect ratios from length L to breadth B of the rectangular footing. The failure mechanisms of rectangular footing which are subjected to the combined vertical loading V and horizontal loading H (Vertical loading V and moment loading M, and horizontal loading H and moment loading M respectively are observed in the finite element analysis. ) is explained by use of the upper bound plasticity limit analysis theory. Finally, the reason of eccentricity of failure envelope in H-M loading space is given in this study, which can not be explained by use of the traditional ' swipe test'.展开更多
Suction caissons are widely used to support offshore fixed platforms in coastal areas. The loadings transferred to suction caissons include the eccentric lateral force induced by waves and self weight of the platform ...Suction caissons are widely used to support offshore fixed platforms in coastal areas. The loadings transferred to suction caissons include the eccentric lateral force induced by waves and self weight of the platform structure. However, under this kind of combined loading conditions, the failure mechanism of caissons with shallow embedment depths is quite different from conventional deep foundations or onshore shallow footings. The behaviour of caissons subjected to combined loadings may be described with the "failure locus" in force resultant spaces. Here the failure loci of smooth caissons are studied by use of finite dement approach, with the embedment ratio of caissons varying in the range of 0.25 - 1.0 and eccentricity ratio of horizontal loadiugs in 0 - 10. The platform settlement and tilt limits are involved into determination of failure loci, thus the platforms can avoid significant displacements for the combined loadings located inside the failure locus. Three families of loading paths are used to map out the locus. It is found that the shape of failure loci depends on 3 non-dimensional parameters, and the failure locus of a given caisson changes gradually from the elliptical curve to hooked curve with increasing shear strength of soil. The lateral capacity of short caissons may be enhanced by vertical forces, compared with the maximum lateral capacity of long caissons occurring at the vertical force being zero. The critical embedment ratios partitioning elliptical and hooked loci are proposed.展开更多
The bearing capacities of spudcan foundation under pure vertical (/1), horizontal (H), moment (M) loading and the combined loading are studied based on a series of three-dimensional finite element analysis. The ...The bearing capacities of spudcan foundation under pure vertical (/1), horizontal (H), moment (M) loading and the combined loading are studied based on a series of three-dimensional finite element analysis. The effects of embedment ratio and soil non-homogeneity on the bearing capacity are investigated in detail. The capacities of spudcan under different pure loading are expressed in non-dimensional bearing capacity factors, which are compared with published results. Ultimate limit states under combined loading are presented by failure envelopes, which are expressed in terms of dimensionless and normalized form in three-dimensional load space. The comparison between the presented failure envelopes and available published numerical results reveals that the size and shape of failure envelopes are dependent on the embedment ratio and the non-homogeneity of the soil.展开更多
The large design freedom of variable-stiffness (VS) composite material presupposes its potential for wide engineering application. Previous research indicates that the design of VS cylindrical structures helps to incr...The large design freedom of variable-stiffness (VS) composite material presupposes its potential for wide engineering application. Previous research indicates that the design of VS cylindrical structures helps to increase the buckling load as compared to quasi-isotropic (QI) cylindrical structures. This paper focuses on the anti-buckling performance of VS cylindrical structures under combined loads and the efficient optimization design method. Two kinds of conditions, bending moment and internal pressure, and bending moment and torque are considered. Influences of the geometrical defects, ovality, on the cylinder's performances are also investigated. To increase the computational efficiency, an adaptive Kriging meta-model is proposed to approximate the structural response of the cylinders. In this improved Kriging model, a mixed updating rule is used in constructing the meta-model. A genetic algorithm (GA) is implemented in the optimization design. The optimal results show that the buckling load of VS cylinders in all cases is greatly increased as compared with a QI cylinder.展开更多
Combined shear-compression tests and simulations were performed on a closed-cell aluminum foam over a wide range of loading angles in order to probe their yield behaviors under biaxial loading conditions.Combined shea...Combined shear-compression tests and simulations were performed on a closed-cell aluminum foam over a wide range of loading angles in order to probe their yield behaviors under biaxial loading conditions.Combined shear-compression tests were carried out by using a pair of cylindrical bars with beveled ends.The yield surfaces were experimentally measured and compared with various theoretical yield surface models.The cellular structures of closed-cell aluminum foams were modeled as tetrakaidecahedrons and their biaxial crushing behaviors were simulated by the finite element method.The results show that,yield initiates from the stress-concentrated corners in the specimens under combined shear-compression loading and the stress distribution is no longer uniform at the specimen/bar interfaces.In the range of cell sizes studied,the larger the foam cell size is,the higher the yield stress is.Aluminum foam density is found to be the dominant factor on its mechanical properties compared with the cell size and is much more significant in engineering practice.展开更多
The foundations of some ocean engineering structures are built to withstand not only the vertical gravity load V, but also the horizontal load H induced by sea waves and current. The horizontal load includes the conce...The foundations of some ocean engineering structures are built to withstand not only the vertical gravity load V, but also the horizontal load H induced by sea waves and current. The horizontal load includes the concentrated force load, the moment load M, and the torque load T termed also as combined loading. It is of academic and engineering significance to study the deformation law of submarine seabed due to combined loading. On the basis of the three-dimensional elastic mechanics solution of circular foundation, numerical methods are used to analyze the deformation law of submarine soil under circular foundation with six degrees of freedom. The finite element analysis results give the elastic deformation law of soil in three dimensional spaces, modify the theoretical elasticity solution, and presents nonlinear soil deformation mechanism under the circular foundation with six degrees of freedom.展开更多
The main objective of this study is to investigate the buckling analysis of CCSs reinforced by CNTs subjected to combined loading of hydrostatic pressure and axial compression resting on the twoparameter elastic found...The main objective of this study is to investigate the buckling analysis of CCSs reinforced by CNTs subjected to combined loading of hydrostatic pressure and axial compression resting on the twoparameter elastic foundation(T-P-EF).It is one of the first attempts to derive the governing equations of the CCSs reinforced with CNTs,based on a generalized first-order shear deformation shell theory(FSDST)which includes shell-foundation interaction.By adopting the extended mixing rule,the effective material properties of CCSs reinforced by CNTs with linear distributions are approximated by introducing some efficiency parameters.Three carbon nanotube distribution in the matrix,i.e.uniform distribution(U)and V and X-types linear distribution are taken into account.The stability equations are solved by using the Galerkin procedure to determine the combined buckling loads(CBLs)of the structure selected here.The numerical illustrations cover CBLs characteristics of CCSs reinforced by CNTs in the presence of the T-P-EF.Finally,a parametric study is carried out to study the influences of the foundation parameters,the volume fraction of carbon nanotubes and the types of reinforcement on the CBLs.展开更多
The dynamic stress intensity factor history for a half plane crack in an otherwise unbounded elastic body, with the crack faces subjected to a traction distribution consisting of two pairs of suddenly-applied shear li...The dynamic stress intensity factor history for a half plane crack in an otherwise unbounded elastic body, with the crack faces subjected to a traction distribution consisting of two pairs of suddenly-applied shear line loads is consid- ered. The analytic expression for the combined mode stress intensity factors as a function of time is obtained. The method of solution is based on the application of integral transforms and the Wiener-Hopf technique. Some features of the solutions are discussed and graphical numerical results are presented.展开更多
The shakedown behavior of structures subjected to a combined loading of constant and cyclic loads has been well researched.For some specified problems,shakedown limit loads have been obtained.However,the general effec...The shakedown behavior of structures subjected to a combined loading of constant and cyclic loads has been well researched.For some specified problems,shakedown limit loads have been obtained.However,the general effect of combined loading on the structural shakedown has not yet been presented.The general analytic solution of the elastic shakedown limit load is thus derived for a structure subjected to combined loading.Polizzotto's extended static shakedown theorem for combined loading is applied.The stress field in equilibrium with the external constant load required in Polizzotto's extended theorem is constructed by subtracting the reference elastic stress field of the peak cyclic load from the elastic-plastic stress field of the combined constant load and peak cyclic load.The shakedown condition of the stress field is then derived according to the extended theorem.Through the analytical analysis of the shakedown condition,the structural shakedown behavior under combined loading is investigated.A general solution of the shakedown limit load is then derived,and the effects of the combined loading on the shakedown behavior are proposed.The obtained general analytical result is applied to a hollow tension specimen under constant tension and alternating torsion and a plate with a central hole under constant and cyclic tension.The results are consistent with the solutions reported in the literature.展开更多
A new fracture criterion was proposed. The physical explanation of the criterion is that crack will propagate when the minimum strain energy density in iso hoop stress curve reach a critical strength of the material c...A new fracture criterion was proposed. The physical explanation of the criterion is that crack will propagate when the minimum strain energy density in iso hoop stress curve reach a critical strength of the material considered. The resulting curve of critical fracture of mixed mode cracks shows that the present fracture is efficient and more accurate than the previous criteria.展开更多
A marine riser,one of the most important components of offshore oil/gas transportation,needs to be designed to eliminate the risks caused by complex ocean environments,platform displacement and internal corrosion,etc....A marine riser,one of the most important components of offshore oil/gas transportation,needs to be designed to eliminate the risks caused by complex ocean environments,platform displacement and internal corrosion,etc.In this study,a new analytical-numerical assessment approach is proposed in order to quantitatively investigate the reliability of internally corroded risers under combined loads including axial tension and internal pressure.First,an analytical solution of the limit state function of intact risers under combined loads is obtained,which is further modified by the non-dimensional corrosion depth (d/ t) for the risers with a narrow and long corrosion defect.The relationship between d/t and limited internal pressure is obtained by finite element analysis and nonlinear regression.Through an advanced first-order reliability method (HL-RF) algorithm,reliability analysis is performed to obtain the failure probability,the reliability index and the sensitivity.These results are further verified by Monte-Carlo importance sampling.The proposed approach of reliability analysis provides an accurate and effective way to estimate the reliability of marine risers with narrow and long corrosion defects under combined loads.展开更多
Tackling the problems of underground water storage in collieries in arid regions requires knowledge of the effect of water intrusion and loading rate on the mechanical properties of and crack development in coal–rock...Tackling the problems of underground water storage in collieries in arid regions requires knowledge of the effect of water intrusion and loading rate on the mechanical properties of and crack development in coal–rock combinations. Fifty-four coal–rock combinations were prepared and split equally into groups containing different moisture contents(dry, natural moisture and saturated) to conduct acoustic emission testing under uniaxial compression with loading rates ranging from 0.1 mm/min to 0.6 mm/min. The results show that the peak stress and strength-softening modulus, elastic modulus, strain-softening modulus, and post-peak modulus partly decrease with increasing moisture content and loading rate. In contrast, peak strain increases with increasing moisture content and fluctuates with rising loading rate. More significantly, the relationship between stiffness and stress, combined with accumulated counts of acoustic emission, can be used to precisely predict all phases of crack propagation. This is helpful in studying the impact of moisture content and loading rate on crack propagation and accurately calculating mechanical properties. We also determined that the stress thresholds of crack closure, crack initiation, and crack damage do not vary with changes of moisture content and loading rate, constituting 15.22%, 32.20%, and 80.98% of peak stress, respectively. These outcomes assist in developing approaches to water storage in coal mines, determining the necessary width of waterproof coal–rock pillars, and methods of supporting water-enriched roadways, while also advances understanding the mechanical properties of coal–rock combinations and laws of crack propagation.展开更多
Rock bolts are subjected to different loading conditions along their lengths such as axial,bending,and/or shear forces,which can cause failure at lower loads than those considered for design purposes.The common existi...Rock bolts are subjected to different loading conditions along their lengths such as axial,bending,and/or shear forces,which can cause failure at lower loads than those considered for design purposes.The common existing methodologies do not consider the actual loading of the rock bolts and assume it is only pure axial or pure shear.This study was conducted to investigate the un-grouted rock bolt performance under combined load conditions.Two loading regimes were evaluated:the effect of initial shear displacement on axial load capacity and displacement,and the effect of axial displacement on the shear load capacity.The first regime was also conducted for shear with a gap,when there is a spacing between the shear interfaces.The results of this study showed that the rock bolt can resist higher axial loads than shear under pure or combined load conditions.Under combined load conditions,the rock bolt capacity decreased significantly for both regimes.However,when applying the shear load with a gap,the rock bolt load capacity was not affected significantly.Also,the total bar deformation was improved for shear and axial.The findings of this study show the need to improve the rock bolt design considering the complex loading conditions in situ with/without a gap.展开更多
In order to improve the reliability of the design and calculation of single piles under the combined vertical and lateral loads, the solutions were presented based on the subgrade reaction method, in which the ultimat...In order to improve the reliability of the design and calculation of single piles under the combined vertical and lateral loads, the solutions were presented based on the subgrade reaction method, in which the ultimate soil resistance was considered and the coefficient of subgrade reaction was assumed to be a constant. The corresponding computational program was developed using FORTRAN language. A comparison between the obtained solutions and the model test results was made to show the validity of the obtained solutions. The calculation results indicate that both the maximum lateral displacement and bending moment increase with the increase of the vertical and lateral loads and the pile length above ground, while decrease as the pile stiffness, the coefficient of subgrade reaction and the yielding displacement of soil increase. It is also shown that the pile head condition controls the pile responses and the vertical load may cause the instability problem to the pile. In general, the proposed method can be employed to calculate the pile responses independent of the magnitude of the pile deflection.展开更多
A unified stress function for bi-modulus beams is proposed based on its mechanic sense on the boundary of beams. Elasticity solutions of stress and displacement for bi-modulus beams under combined loads are derived. T...A unified stress function for bi-modulus beams is proposed based on its mechanic sense on the boundary of beams. Elasticity solutions of stress and displacement for bi-modulus beams under combined loads are derived. The example analysis shows that the maximum tensile stress using the same elastic modulus theory is underestimated if the tensile elastic modulus is larger than the compressive elastic modulus. Otherwise, the maximum compressive stress is underestimated. The maximum tensile stress using the material mechanics solution is underestimated when the tensile elastic modulus is larger than the compressive elastic modulus to a certain extent. The error of stress using the material mechanics theory decreases as the span-to-height ratio of beams increases, which is apparent when L/h ≤ 5. The error also varies with the distributed load patterns.展开更多
A nonlinear numerical model was developed to analyze reinforced concrete columns under combined axial load and bending up to failure. Results of reinforced concrete columns under eccentric compression tested to failur...A nonlinear numerical model was developed to analyze reinforced concrete columns under combined axial load and bending up to failure. Results of reinforced concrete columns under eccentric compression tested to failure are presented and compared to results from a numerical nonlinear model. The tests involved 10 columns with cross-section of 250 mm × 120 mm, geometrical reinforcement ratio of 1.57% and concrete with compression strength around 40 MPa, with 3,000 mm in length. The main variable was the load eccentricity in the direction of the smaller dimension of cross-section. Experimental results of ultimate load and of the evolution of transverse displacements and concrete strains are compared with the numerical results. The estimated results obtained by the numerical model are close to the experimental ones, being suitable for use in verification of elements under combined axial load and bending.展开更多
In order to solve the problem of calculating the ultimate strength of marine plate under pitting corrosion,the plate taking from marine with pitting corrosion was studied. Based on the data of pitting corrosion record...In order to solve the problem of calculating the ultimate strength of marine plate under pitting corrosion,the plate taking from marine with pitting corrosion was studied. Based on the data of pitting corrosion recorded,the concept of pitting corrosion characteristic element matrix was proposed to describe the distribution and the forms of pitting. Moreover,the model of sensitivity calculation was established to analyse the sensitivity of pitting corrosion characteristic elements for the ultimate bearing capacity of ship structural plate. A new approach was proposed to calculate the ultimate strength of pitting damaged ship structural plate under combined loads based on the factor of rigidity reduction. Simultaneously this new approach was proven to be validated by finite element simulation. Finally,formula of ultimate strength of pitting damaged ship hull plate was established by series of numerical calculations based on the approach,and the reliability of the formula was validated as well.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.12032010,11902155 and 12072250)by the Natural Science Foundation of Jiangsu Province(Grant No.BK20190382)+2 种基金by the Research Fund of State Key Laboratory of Mechanics and Control of Mechanical Structures(Grant No.MCMS-I-0222K01)by the Fund of Prospective Layout of Scientific Research for NUAAby the Foundation for the Priority Academic Program Development of Jiangsu Higher Education Institutions。
文摘Ultra-high molecular weight polyethylene(UHMWPE)fiber composite has been extensively used to construct lightweight protective structures against ballistic impacts,yet little is known about its performance when subjected to combined blast and fragment impacts.Built upon a recently developed laboratory-scale experimental technique to generate simulated combined loading through the impact of a fragment-foam composite projectile launched from a light gas gun,the dynamic responses of fullyclamped UHMWPE plates subjected to combined loading were characterized experimentally,with corresponding deformation and failure modes compared with those measured with simulated blast loading alone.Subsequently,to explore the underlying physical mechanisms,three-dimensional(3D)numerical simulations with the method of finite elements(FE)were systematically carried out.Numerical predictions compared favorably well with experimental measurements,thus validating the feasibility of the established FE model.Relative to the case of blast loading alone,combined blast and fragment loading led to larger maximum deflections of clamped UHMWPE plates.The position of the FSP in the foam sabot affected significantly the performance of a UHMWPE target,either enhancing or decreasing its ballistic resistance.When the blast loading and fragment impact arrived simultaneously at the target,its ballistic resistance was superior to that achieved when subjected to fragment impact alone,and benefited from the accelerated movement of the target due to simultaneous blast loading.
基金This paper is financially supported by the National Natural Science Foundation of China(Grant Nos.52074263 and 52034007)the Postgraduate Research and Practice Innovation Program of Jiangsu Province(Grant No.KYCX21_2332).
文摘Dynamic load on anchoring structures(AS)within deep roadways can result in cumulative damage and failure.This study develops an experimental device designed to test AS under triaxial loads.The device enables the investigation of the mechanical response,failure mode,instability assessment criteria,and anchorage effect of AS subjected to combined cyclic dynamic-static triaxial stress paths.The results show that the peak bearing strength is positively correlated with the anchoring matrix strength,anchorage length,and edgewise compressive strength.The bearing capacity decreases significantly when the anchorage direction is severely inclined.The free face failure modes are typically transverse cracking,concave fracturing,V-shaped slipping and detachment,and spallation detachment.Besides,when the anchoring matrix strength and the anchorage length decrease while the edgewise compressive strength,loading rate,and anchorage inclination angle increase,the failure intensity rises.Instability is determined by a negative tangent modulus of the displacement-strength curve or the continued deformation increase against the general downward trend.Under cyclic loads,the driving force that breaks the rock mass along the normal vector and the rigidity of the AS are the two factors that determine roadway stability.Finally,a control measure for surrounding rock stability is proposed to reduce the internal driving force via a pressure relief method and improve the rigidity of the AS by full-length anchorage and grouting modification.
文摘In this study,an iterative-based three-dimensional finite element lower bound in association with the second-order cone programming method is adopted to evaluate the limit load of a single pile embedded in cross-anisotropic soils under general loading condition.The lower bound solutions of the pile embedded in an anisotropic soil deposit can be found by formulating the element equilibrium,equilibrium of shear and normal stresses along discontinuities,boundary conditions,yield function,and optimizing the objective function through the second-order cone programming method in conjunction with an iterative-based update procedure.A general loading condition is considered to profile the expansion of the safe load in the vertical-horizontal-moment(V-H-M)space.The results of this study are compared and validated against three different cases including an isotropic lateral loading,anisotropic end bearing capacity,and a pile embedded in an isotropic soil deposit under general loading condition.A parametric study is conducted to evaluate the impact of different influencing factors.It was found that the effect of anisotropy on the variation of lateral limit load of a single pile is more pronounced than the corresponding vertical and bending moment limit loads,whereas the interface properties have more significant effects on the vertical and bending moment limit loads in comparison to the lateral limit load.
基金This project is financially supported by the National Natural Science Foundation of China(Grant Nos.50639010,50579006 and 50179006)
文摘This paper presents two kinematic failure mechanisms of threc-dimensional rectangular footing resting on homogeneous undrained clay foundation under uniaxial vertical loading and uniaxial moment loading. The failure mechanism under vertical loading comprises a plane strain Prandti-type mechanism over the central part of the longer side, and the size of the mechanism gradually reduces at the ends of the longer side and over the shorter side as the corner of rectangular footing is being approached where the direction of soil motion remains normal to each corresponding side respectively. The failure mechanism under moment loading comprises a plane strain scoop sliding mechanism over the central part of the longer side, and the radius of scoop sliding mechanism increases linearly at the ends of the longer side. On the basis of the kinematic failure mechanisms mentioned above, the vertical ultimate bearing capacity and the ultimate bearing capacity against moment or moment ultimate bearing capacity are obtained by use of upper bound limit analysis theory. At the same time, numerical analysis results, Skempton' s results and Salgado et al. 's results are compared with this upper bound solution. It shows that the presented failure mechanisms and plastic limit analysis predictions are validated. In order to investigate the behaviors of undrained clay foundation beneath the rectangular footing subjected to the combined loadings, numerical analysis is adopted by virtue of the general-purpose FEM software ABAQUS, where the clay is assumed to obey the Mohr-Coulomb yielding criterion. The failure envelope and the ultimate bearing capacity are achieved by the numerical analysis results with the varying aspect ratios from length L to breadth B of the rectangular footing. The failure mechanisms of rectangular footing which are subjected to the combined vertical loading V and horizontal loading H (Vertical loading V and moment loading M, and horizontal loading H and moment loading M respectively are observed in the finite element analysis. ) is explained by use of the upper bound plasticity limit analysis theory. Finally, the reason of eccentricity of failure envelope in H-M loading space is given in this study, which can not be explained by use of the traditional ' swipe test'.
基金the National Natural Science Foundation of China (Grant No.50309001)
文摘Suction caissons are widely used to support offshore fixed platforms in coastal areas. The loadings transferred to suction caissons include the eccentric lateral force induced by waves and self weight of the platform structure. However, under this kind of combined loading conditions, the failure mechanism of caissons with shallow embedment depths is quite different from conventional deep foundations or onshore shallow footings. The behaviour of caissons subjected to combined loadings may be described with the "failure locus" in force resultant spaces. Here the failure loci of smooth caissons are studied by use of finite dement approach, with the embedment ratio of caissons varying in the range of 0.25 - 1.0 and eccentricity ratio of horizontal loadiugs in 0 - 10. The platform settlement and tilt limits are involved into determination of failure loci, thus the platforms can avoid significant displacements for the combined loadings located inside the failure locus. Three families of loading paths are used to map out the locus. It is found that the shape of failure loci depends on 3 non-dimensional parameters, and the failure locus of a given caisson changes gradually from the elliptical curve to hooked curve with increasing shear strength of soil. The lateral capacity of short caissons may be enhanced by vertical forces, compared with the maximum lateral capacity of long caissons occurring at the vertical force being zero. The critical embedment ratios partitioning elliptical and hooked loci are proposed.
基金supported by the National Natural Science Foundation of China(Grant No. 50779061)
文摘The bearing capacities of spudcan foundation under pure vertical (/1), horizontal (H), moment (M) loading and the combined loading are studied based on a series of three-dimensional finite element analysis. The effects of embedment ratio and soil non-homogeneity on the bearing capacity are investigated in detail. The capacities of spudcan under different pure loading are expressed in non-dimensional bearing capacity factors, which are compared with published results. Ultimate limit states under combined loading are presented by failure envelopes, which are expressed in terms of dimensionless and normalized form in three-dimensional load space. The comparison between the presented failure envelopes and available published numerical results reveals that the size and shape of failure envelopes are dependent on the embedment ratio and the non-homogeneity of the soil.
基金the National NaturalScience Foundation of China (Grant 11572134)the China PostdoctoralScience Foundation (Grant 2017M612443).
文摘The large design freedom of variable-stiffness (VS) composite material presupposes its potential for wide engineering application. Previous research indicates that the design of VS cylindrical structures helps to increase the buckling load as compared to quasi-isotropic (QI) cylindrical structures. This paper focuses on the anti-buckling performance of VS cylindrical structures under combined loads and the efficient optimization design method. Two kinds of conditions, bending moment and internal pressure, and bending moment and torque are considered. Influences of the geometrical defects, ovality, on the cylinder's performances are also investigated. To increase the computational efficiency, an adaptive Kriging meta-model is proposed to approximate the structural response of the cylinders. In this improved Kriging model, a mixed updating rule is used in constructing the meta-model. A genetic algorithm (GA) is implemented in the optimization design. The optimal results show that the buckling load of VS cylinders in all cases is greatly increased as compared with a QI cylinder.
基金Project(2017JJ3359)supported by the Natural Science Foundation of Hunan Province,ChinaProject(KFJJ13-11M)supported by the Opening Project of State Key Laboratory of Explosion Science and Technology(Beijing Institute of Technology),China.
文摘Combined shear-compression tests and simulations were performed on a closed-cell aluminum foam over a wide range of loading angles in order to probe their yield behaviors under biaxial loading conditions.Combined shear-compression tests were carried out by using a pair of cylindrical bars with beveled ends.The yield surfaces were experimentally measured and compared with various theoretical yield surface models.The cellular structures of closed-cell aluminum foams were modeled as tetrakaidecahedrons and their biaxial crushing behaviors were simulated by the finite element method.The results show that,yield initiates from the stress-concentrated corners in the specimens under combined shear-compression loading and the stress distribution is no longer uniform at the specimen/bar interfaces.In the range of cell sizes studied,the larger the foam cell size is,the higher the yield stress is.Aluminum foam density is found to be the dominant factor on its mechanical properties compared with the cell size and is much more significant in engineering practice.
基金The financial support for this study is through the grants 50909050 from the National Natural Science Foundation of ChinaZR2009FQ004 from the Natural Science Foundation of Shandong Province
文摘The foundations of some ocean engineering structures are built to withstand not only the vertical gravity load V, but also the horizontal load H induced by sea waves and current. The horizontal load includes the concentrated force load, the moment load M, and the torque load T termed also as combined loading. It is of academic and engineering significance to study the deformation law of submarine seabed due to combined loading. On the basis of the three-dimensional elastic mechanics solution of circular foundation, numerical methods are used to analyze the deformation law of submarine soil under circular foundation with six degrees of freedom. The finite element analysis results give the elastic deformation law of soil in three dimensional spaces, modify the theoretical elasticity solution, and presents nonlinear soil deformation mechanism under the circular foundation with six degrees of freedom.
文摘The main objective of this study is to investigate the buckling analysis of CCSs reinforced by CNTs subjected to combined loading of hydrostatic pressure and axial compression resting on the twoparameter elastic foundation(T-P-EF).It is one of the first attempts to derive the governing equations of the CCSs reinforced with CNTs,based on a generalized first-order shear deformation shell theory(FSDST)which includes shell-foundation interaction.By adopting the extended mixing rule,the effective material properties of CCSs reinforced by CNTs with linear distributions are approximated by introducing some efficiency parameters.Three carbon nanotube distribution in the matrix,i.e.uniform distribution(U)and V and X-types linear distribution are taken into account.The stability equations are solved by using the Galerkin procedure to determine the combined buckling loads(CBLs)of the structure selected here.The numerical illustrations cover CBLs characteristics of CCSs reinforced by CNTs in the presence of the T-P-EF.Finally,a parametric study is carried out to study the influences of the foundation parameters,the volume fraction of carbon nanotubes and the types of reinforcement on the CBLs.
基金The project supported by the National Natural Science Foundation of China
文摘The dynamic stress intensity factor history for a half plane crack in an otherwise unbounded elastic body, with the crack faces subjected to a traction distribution consisting of two pairs of suddenly-applied shear line loads is consid- ered. The analytic expression for the combined mode stress intensity factors as a function of time is obtained. The method of solution is based on the application of integral transforms and the Wiener-Hopf technique. Some features of the solutions are discussed and graphical numerical results are presented.
基金Sponsored by the National Natural Science Foundation of China(Grant No.51575474)the College Innovation Team Leader Training Program of Province(Grant No.LJRC012)the Natural Science Foundation of Hebei Province,China(Grant No.E2015203220)
文摘The shakedown behavior of structures subjected to a combined loading of constant and cyclic loads has been well researched.For some specified problems,shakedown limit loads have been obtained.However,the general effect of combined loading on the structural shakedown has not yet been presented.The general analytic solution of the elastic shakedown limit load is thus derived for a structure subjected to combined loading.Polizzotto's extended static shakedown theorem for combined loading is applied.The stress field in equilibrium with the external constant load required in Polizzotto's extended theorem is constructed by subtracting the reference elastic stress field of the peak cyclic load from the elastic-plastic stress field of the combined constant load and peak cyclic load.The shakedown condition of the stress field is then derived according to the extended theorem.Through the analytical analysis of the shakedown condition,the structural shakedown behavior under combined loading is investigated.A general solution of the shakedown limit load is then derived,and the effects of the combined loading on the shakedown behavior are proposed.The obtained general analytical result is applied to a hollow tension specimen under constant tension and alternating torsion and a plate with a central hole under constant and cyclic tension.The results are consistent with the solutions reported in the literature.
文摘A new fracture criterion was proposed. The physical explanation of the criterion is that crack will propagate when the minimum strain energy density in iso hoop stress curve reach a critical strength of the material considered. The resulting curve of critical fracture of mixed mode cracks shows that the present fracture is efficient and more accurate than the previous criteria.
基金the National Basic Research Program of China(973 Program,Grant No.2011CB013702)the Beijing Natural Science Foundation(Grant No.KZ201210017017)
文摘A marine riser,one of the most important components of offshore oil/gas transportation,needs to be designed to eliminate the risks caused by complex ocean environments,platform displacement and internal corrosion,etc.In this study,a new analytical-numerical assessment approach is proposed in order to quantitatively investigate the reliability of internally corroded risers under combined loads including axial tension and internal pressure.First,an analytical solution of the limit state function of intact risers under combined loads is obtained,which is further modified by the non-dimensional corrosion depth (d/ t) for the risers with a narrow and long corrosion defect.The relationship between d/t and limited internal pressure is obtained by finite element analysis and nonlinear regression.Through an advanced first-order reliability method (HL-RF) algorithm,reliability analysis is performed to obtain the failure probability,the reliability index and the sensitivity.These results are further verified by Monte-Carlo importance sampling.The proposed approach of reliability analysis provides an accurate and effective way to estimate the reliability of marine risers with narrow and long corrosion defects under combined loads.
基金Project(2014QNB31)supported by the Fundamental Research Funds for the Central Universities,ChinaProjects(51674248)supported by the National Natural Science Foundation of ChinaProject supported by the Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD),China
文摘Tackling the problems of underground water storage in collieries in arid regions requires knowledge of the effect of water intrusion and loading rate on the mechanical properties of and crack development in coal–rock combinations. Fifty-four coal–rock combinations were prepared and split equally into groups containing different moisture contents(dry, natural moisture and saturated) to conduct acoustic emission testing under uniaxial compression with loading rates ranging from 0.1 mm/min to 0.6 mm/min. The results show that the peak stress and strength-softening modulus, elastic modulus, strain-softening modulus, and post-peak modulus partly decrease with increasing moisture content and loading rate. In contrast, peak strain increases with increasing moisture content and fluctuates with rising loading rate. More significantly, the relationship between stiffness and stress, combined with accumulated counts of acoustic emission, can be used to precisely predict all phases of crack propagation. This is helpful in studying the impact of moisture content and loading rate on crack propagation and accurately calculating mechanical properties. We also determined that the stress thresholds of crack closure, crack initiation, and crack damage do not vary with changes of moisture content and loading rate, constituting 15.22%, 32.20%, and 80.98% of peak stress, respectively. These outcomes assist in developing approaches to water storage in coal mines, determining the necessary width of waterproof coal–rock pillars, and methods of supporting water-enriched roadways, while also advances understanding the mechanical properties of coal–rock combinations and laws of crack propagation.
基金The authors would like to thank Mining3,Minerals Research Institute of Western Australia,Curtin University and Peabody Energy for funding this research project.They also wish to thank Minova Global and its personnel who assisted in completing all the tests conducted at their facility in Nowra,NSW and for providing the rock bolts for testing.
文摘Rock bolts are subjected to different loading conditions along their lengths such as axial,bending,and/or shear forces,which can cause failure at lower loads than those considered for design purposes.The common existing methodologies do not consider the actual loading of the rock bolts and assume it is only pure axial or pure shear.This study was conducted to investigate the un-grouted rock bolt performance under combined load conditions.Two loading regimes were evaluated:the effect of initial shear displacement on axial load capacity and displacement,and the effect of axial displacement on the shear load capacity.The first regime was also conducted for shear with a gap,when there is a spacing between the shear interfaces.The results of this study showed that the rock bolt can resist higher axial loads than shear under pure or combined load conditions.Under combined load conditions,the rock bolt capacity decreased significantly for both regimes.However,when applying the shear load with a gap,the rock bolt load capacity was not affected significantly.Also,the total bar deformation was improved for shear and axial.The findings of this study show the need to improve the rock bolt design considering the complex loading conditions in situ with/without a gap.
基金Foundation item: Projects(50708093, 50808159) supported by the National Natural Science Foundation of China
文摘In order to improve the reliability of the design and calculation of single piles under the combined vertical and lateral loads, the solutions were presented based on the subgrade reaction method, in which the ultimate soil resistance was considered and the coefficient of subgrade reaction was assumed to be a constant. The corresponding computational program was developed using FORTRAN language. A comparison between the obtained solutions and the model test results was made to show the validity of the obtained solutions. The calculation results indicate that both the maximum lateral displacement and bending moment increase with the increase of the vertical and lateral loads and the pile length above ground, while decrease as the pile stiffness, the coefficient of subgrade reaction and the yielding displacement of soil increase. It is also shown that the pile head condition controls the pile responses and the vertical load may cause the instability problem to the pile. In general, the proposed method can be employed to calculate the pile responses independent of the magnitude of the pile deflection.
基金Project supported by the Doctoral Fund of Ministry of Education of China(No.20103108110019)the National Natural Science Foundation of China(No.51208292)the National Key Technology R&D Programs(Nos.2011BAG07B01 and 2012BAK24B04)
文摘A unified stress function for bi-modulus beams is proposed based on its mechanic sense on the boundary of beams. Elasticity solutions of stress and displacement for bi-modulus beams under combined loads are derived. The example analysis shows that the maximum tensile stress using the same elastic modulus theory is underestimated if the tensile elastic modulus is larger than the compressive elastic modulus. Otherwise, the maximum compressive stress is underestimated. The maximum tensile stress using the material mechanics solution is underestimated when the tensile elastic modulus is larger than the compressive elastic modulus to a certain extent. The error of stress using the material mechanics theory decreases as the span-to-height ratio of beams increases, which is apparent when L/h ≤ 5. The error also varies with the distributed load patterns.
文摘A nonlinear numerical model was developed to analyze reinforced concrete columns under combined axial load and bending up to failure. Results of reinforced concrete columns under eccentric compression tested to failure are presented and compared to results from a numerical nonlinear model. The tests involved 10 columns with cross-section of 250 mm × 120 mm, geometrical reinforcement ratio of 1.57% and concrete with compression strength around 40 MPa, with 3,000 mm in length. The main variable was the load eccentricity in the direction of the smaller dimension of cross-section. Experimental results of ultimate load and of the evolution of transverse displacements and concrete strains are compared with the numerical results. The estimated results obtained by the numerical model are close to the experimental ones, being suitable for use in verification of elements under combined axial load and bending.
基金Sponsored by the National Natural Science Foundation of China(Grant Nos.51309231 and 51779261)
文摘In order to solve the problem of calculating the ultimate strength of marine plate under pitting corrosion,the plate taking from marine with pitting corrosion was studied. Based on the data of pitting corrosion recorded,the concept of pitting corrosion characteristic element matrix was proposed to describe the distribution and the forms of pitting. Moreover,the model of sensitivity calculation was established to analyse the sensitivity of pitting corrosion characteristic elements for the ultimate bearing capacity of ship structural plate. A new approach was proposed to calculate the ultimate strength of pitting damaged ship structural plate under combined loads based on the factor of rigidity reduction. Simultaneously this new approach was proven to be validated by finite element simulation. Finally,formula of ultimate strength of pitting damaged ship hull plate was established by series of numerical calculations based on the approach,and the reliability of the formula was validated as well.