期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Initiative Optimization Operation Strategy and Multi-objective Energy Management Method for Combined Cooling Heating and Power 被引量:4
1
作者 Feng Zhao Chenghui Zhang Bo Sun 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI 2016年第4期385-393,共9页
This paper proposed an initiative optimization operation strategy and multi-objective energy management method for combined cooling heating and power(CCHP) with storage systems.Initially,the initiative optimization op... This paper proposed an initiative optimization operation strategy and multi-objective energy management method for combined cooling heating and power(CCHP) with storage systems.Initially,the initiative optimization operation strategy of CCHP system in the cooling season,the heating season and the transition season was formulated.The energy management of CCHP system was optimized by the multi-objective optimization model with maximum daily energy efficiency,minimum daily carbon emissions and minimum daily operation cost based on the proposed initiative optimization operation strategy.Furthermore,the pareto optimal solution set was solved by using the niche particle swarm multi-objective optimization algorithm.Ultimately,the most satisfactory energy management scheme was obtained by using the technique for order preference by similarity to ideal solution(TOPSIS) method.A case study of CCHP system used in a hospital in the north of China validated the effectiveness of this method.The results showed that the satisfactory energy management scheme of CCHP system was obtained based on this initiative optimization operation strategy and multi-objective energy management method.The CCHP system has achieved better energy efficiency,environmental protection and economic benefits. 展开更多
关键词 Multi-objective optimization energy management initiative optimization distributed energy sources combined cooling heating and power(CCHP) operation strategy
下载PDF
Energetic, economic, and environmental analysis of solid oxide fuel cell-based combined cooling, heating, and power system for cancer care hospital
2
作者 Ahmad K.Sleiti Wahib AAl-Ammari +1 位作者 Raiha Arshad Tarek EI Mekkawy 《Building Simulation》 SCIE EI CSCD 2022年第8期1437-1454,共18页
In this study,energetic,economic,and environmental analysis of solid oxide fuel cell-based combined cooling,heating,and power(SOFC-CCHP)system is proposed for a cancer care hospital building.The energy required for th... In this study,energetic,economic,and environmental analysis of solid oxide fuel cell-based combined cooling,heating,and power(SOFC-CCHP)system is proposed for a cancer care hospital building.The energy required for the hospital power,cooling,and heating demands was obtained based on real and detailed field data,which could serve as a reference for future works in the field.These data with a 3D model for the hospital building are constructed and created in eQUEST software to precisely calculate the energy demands of the existing system(baseline case).Then,energetic,economic,and environmental models were developed to compare and assess the performance of the proposed SOFC-CCHP system.The results show that the proposed system can cover about 49% to 77% of the power demand of the hospital with an overall efficiency of 78.3%.Also,the results show that the levelized cost of electricity of the system and its payback period at the designed capacity of the SOFC is 0.087S/kWh and 10 years,respectively.Furthermore,compared to the baseline system of the hospital,the SOFC-CCHP reduces the CO_(2) emission by 89% over the year.The sensitivity analysis showed that a maximum SOFC efficiency of 52%and overall efficiency of 80%are achieved at cell operating temperature of 1027℃ and fuel utilization factor of 0.85. 展开更多
关键词 combined cooling heating and power solid oxide fuel cell hospital power demand CO_(2)emissions levelized cost of electricity(LCOE)
原文传递
Operation Strategy Analysis and Configuration Optimization of Solar CCHP System
3
作者 Duojin Fan Chengji Shi +1 位作者 Kai Sun Xiaojuan Lu 《Energy Engineering》 EI 2021年第4期1197-1221,共25页
This paper proposed a new type of combined cooling heating and power(CCHP)system,including the parabolic trough solar thermal(PTST)power generation and gas turbine power generation.The thermal energy storage subsystem... This paper proposed a new type of combined cooling heating and power(CCHP)system,including the parabolic trough solar thermal(PTST)power generation and gas turbine power generation.The thermal energy storage subsystem in the PTST unit provides both thermal energy and electrical energy.Based on the life cycle method,the configuration optimization under eight operation strategies is studied with the economy,energy,and environment indicators.The eight operation strategies include FEL,FEL-EC,FEL-TES,FEL-TES&EC,FTL,FTL-EC,FTL-TES,and FTL-TES&EC.The feasibility of each strategy is verified by taking a residential building cluster as an example.The indicators under the optimal configuration of each strategy are compared with that of the separate production(SP)system.The results showed that the PTST-CCHP system improves the environment and energy performance by changing the ratio of thermal energy and electric energy.The environment and energy indicators of FEL-TES&EC are superior to those of FTL-TES&EC in summer,and the results are just the opposite in winter.The initial annual investment of the PTST-CCHP system is higher than that of the SP system,but its economic performance is better than that of the SP system with the increase of life-cycle. 展开更多
关键词 combined cooling heating and power(CCHP)system trough solar thermal power generation operation strategy optimization configuration hill-climbing algorithm(HCA)
下载PDF
A multi agent-based optimal control method for combined cooling and power systems with thermal energy storage
4
作者 Zihao Wang Chaobo Zhang +1 位作者 Hongbo Li Yang Zhao 《Building Simulation》 SCIE EI CSCD 2021年第6期1709-1723,共15页
Combined cooling,heating and power(CCHP)systems have been considered as a potential energy saving technology for buildings due to their high energy efficiency and low carbon emission.Thermal energy storage(TES)can imp... Combined cooling,heating and power(CCHP)systems have been considered as a potential energy saving technology for buildings due to their high energy efficiency and low carbon emission.Thermal energy storage(TES)can improve the energy efficiency of CCHP systems,since they reduce the mismatch between the energy supply and demand.However,it also increases the complexity of operation optimization of CCHP systems.In this study,a multi-agent system(MAS)-based optimal control method is proposed to minimize the operation cost of CCHP systems combined with TES.Four types of agents,i.e.,coordinator agents,building agents,energy management agents and optimization agents,are implemented in the MAS to cooperate with each other.The operation optimization problem is solved by the genetic algorithm.A simulated system is utilized to validate the performance of the proposed method.Results show that the operation cost reductions of 10.0%on a typical summer day and 7.7%on a typical spring day are achieved compared with a rule-based control method.A sensitivity analysis is further performed and results show that the optimal operation cost does not change obviously when the rated capacity of TES exceeds a threshold. 展开更多
关键词 multi-agent systems distributed control-operation optimization demand response combined cooling heating and power system thermal energy storage
原文传递
Dynamic Simulation and Performance Analysis on Multi-Energy Coupled CCHP System
5
作者 Xueqin Tian Jinfei Sun +5 位作者 Tong Xu Mengran Cui Xinlei Wang Jianxiang Guo De-gejirifu Na Wang 《Energy Engineering》 EI 2022年第2期723-737,共15页
Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matchi... Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matching between supply and demand loads due to the unbalance features of the user’s cooling and heating loads.On the basis of user convenience and wide applicability of clean air energy,this paper tries to put forward a coupled CCHP system with combustion gas turbine and ASHP ordered power by heat,analyze trends of such parameters as gas consumption and power consumption of heat pump in line with adjustment of heating load proportion of combustion gas turbine,and optimize the system ratio in the method of annual costs and energy environmental benefit assessment.Based on the analysis of the hourly simulation and matching characteristics of the cold and hot load of the 100 thousand square meter building,it is found that the annual cost of the air source heat pump is low,but the energy and environmental benefits are poor.It will lead to 6.35%shortage of cooling load in summer.Combined with the evaluation method of primary energy consumption and zero carbon dioxide emission,the coupling system of CHHP and air source heat pump with 41%gas turbine load ratio is the best configuration.This system structure and optimization method can provide some reference for the development of CCHP coupling system. 展开更多
关键词 CCHP(combined cooling heating and power System) ASHP(Air Source Heat Pump) annual costs absorption cooling transient simulation
下载PDF
Prime Mover Capacity Optimization and Thermodynamic Performance Analysis of Internal Combustion Engine Based CCHP System
6
作者 WANG Shucheng MUHAMMAD Imran +2 位作者 LI Hongwei CHEN Xiaoxu QIN Mei 《Journal of Thermal Science》 SCIE EI CAS CSCD 2023年第4期1583-1594,共12页
In this research,a solar hybrid combined cooling heating and power(CCHP)system is proposed considering the different scenarios of Prime Movers(PMs)and the part-load performance of PMs is validated by the designed valu... In this research,a solar hybrid combined cooling heating and power(CCHP)system is proposed considering the different scenarios of Prime Movers(PMs)and the part-load performance of PMs is validated by the designed values from the manufacturer of Volvo.Moreover,a multi-optimization model based on a genetic algorithm is developed in order to select both the most promising performance PM and the most cost-effectiveness,environmentally friendly number of collectors for the proposed CCHP system,simultaneously.Then the hourly performance of this solar hybrid CCHP is determined through a case study of a hotel in Shanghai.Results show that the highest efficiency of the PM with larger capacity has the most promising performance and the collector number of 90 turns out to be a superior value for the hotel building based on the primary energy saving ratio of 61.61%.Moreover,on a typical summer day,the recovered waste heat and the solar energy can provide all the thermal energy demands,while,an auxiliary boiler should be started to fulfill the energy gap in both typical transition and winter days.From the simulation result,the CO_(2) emissions can be reduced by 856.2 t/a due to the solar energy introduced into the system.Besides,the dynamic investment payback period will change from 3.01 years to 3.56 years when the fuel price(P_(fuel))ranges from 0.8P_(fuel) to1.2P_(fuel). 展开更多
关键词 combined cooling heating and power(CCHP)system distributed energy system OPTIMIZATION waste heat recovery ICE
原文传递
Thermo-economic analysis of the performance of the combined system with evacuated tube collectors
7
作者 Ghassan Fadhil Smaisim Salema K.Hadrawi +2 位作者 Azher M.Abed Hasan Sh.Majdi Ali Shamel 《Clean Energy》 EI CSCD 2023年第2期242-252,共11页
Using combined cooling,heat and power systems can be an appropriate substitute for preventing emissions of pollutants and excessive consumption of fossil fuels.Utilizing renewable energy in these systems as a source o... Using combined cooling,heat and power systems can be an appropriate substitute for preventing emissions of pollutants and excessive consumption of fossil fuels.Utilizing renewable energy in these systems as a source of power generation can be an appropriate substitute for fossil-fuel-based systems.Therefore,in this paper,cogeneration cooling,heat and power systems based on gas-fired internal combustion engines with a solar-thermal system with evacuated tube collectors have been modelled and thermo-economic analysis has been done to compare fossil-fuel-based systems.The required rate of heat to supply the hot water is 50 kW.In the studied system,the internal combustion engine produces electrical energy.Then,the solar-thermal system with evacuated tube collectors and the gas-burning generator provide the thermal energy required by the studied building and the primary stimulus of the absorption chiller for cooling.In this study,two different scenarios are conducted in states considering simultaneous production systems and regardless of this environmental and thermo-economic analysis system.The results showed that the efficiency of the studied system was 60% in summer and 56% in winter. 展开更多
关键词 combined cooling heat and power thermo-economic analysis evacuated tube collectors environmental analysis solar-thermal energy
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部