期刊文献+
共找到718篇文章
< 1 2 36 >
每页显示 20 50 100
A Financial Approach to Evaluate an Optimized Combined Cooling, Heat and Power System 被引量:20
1
作者 Shahab Bahrami Farahbakhsh Safe 《Energy and Power Engineering》 2013年第5期352-362,共11页
Iran’s removing subsidy from energy carrier in four years ago leads to spike electricity price dramatically. This abrupt change increases the interest on distributed generation (DG) because of its several benefits su... Iran’s removing subsidy from energy carrier in four years ago leads to spike electricity price dramatically. This abrupt change increases the interest on distributed generation (DG) because of its several benefits such as lower electricity generation price. In Iran among all type of DGs, because of wide natural gas network infrastructure and several incentives that government legislated to support combined cooling, heat and power (CCHP) investors, this type of technology is more prevalent in comparison with other technologies. Between existing CCHP technologies, certain economic choices are to be taken into account. For different buildings with different load curves, suitable size and operation of CCHP should be calculated to make the project more feasible. If CCHP does not well suited for a position, then the whole energy efficiency would be plunged significantly. In this paper, a model to find the optimal size and operation of CCHP and auxiliary boiler for any users is proposed by considering an integrated view of electricity and natural gas network using GAMS software. Then this method is applying for a hospital in Tehran as a real case study. Finally, by applying COMFAR III software, useful financial parameters and sensitivity analysis are calculated. 展开更多
关键词 combined cooling heat and power (CCHP) Energy HUB Optimal SIZE FINANCIAL Analysis
下载PDF
Initiative Optimization Operation Strategy and Multi-objective Energy Management Method for Combined Cooling Heating and Power 被引量:4
2
作者 Feng Zhao Chenghui Zhang Bo Sun 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI 2016年第4期385-393,共9页
This paper proposed an initiative optimization operation strategy and multi-objective energy management method for combined cooling heating and power(CCHP) with storage systems.Initially,the initiative optimization op... This paper proposed an initiative optimization operation strategy and multi-objective energy management method for combined cooling heating and power(CCHP) with storage systems.Initially,the initiative optimization operation strategy of CCHP system in the cooling season,the heating season and the transition season was formulated.The energy management of CCHP system was optimized by the multi-objective optimization model with maximum daily energy efficiency,minimum daily carbon emissions and minimum daily operation cost based on the proposed initiative optimization operation strategy.Furthermore,the pareto optimal solution set was solved by using the niche particle swarm multi-objective optimization algorithm.Ultimately,the most satisfactory energy management scheme was obtained by using the technique for order preference by similarity to ideal solution(TOPSIS) method.A case study of CCHP system used in a hospital in the north of China validated the effectiveness of this method.The results showed that the satisfactory energy management scheme of CCHP system was obtained based on this initiative optimization operation strategy and multi-objective energy management method.The CCHP system has achieved better energy efficiency,environmental protection and economic benefits. 展开更多
关键词 Multi-objective optimization energy management initiative optimization distributed energy sources combined cooling heating and power(CCHP) operation strategy
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
3
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
城市化进程的加快意味着城市和国际组织需要去寻找各种能够提高能源效率和减少空气中污染物排放的方法。冷热电联产(CCHP)系统可以同时供暖、制冷和发电,具有提高城市或城市区域能源发电效率的潜力。本研究的目的是在满足建筑热需求(供... 城市化进程的加快意味着城市和国际组织需要去寻找各种能够提高能源效率和减少空气中污染物排放的方法。冷热电联产(CCHP)系统可以同时供暖、制冷和发电,具有提高城市或城市区域能源发电效率的潜力。本研究的目的是在满足建筑热需求(供热和制冷)的各种运行条件下,对亚特兰大大都市区内的五种常见建筑类型在采用CCHP系统时的发电耗水、CO_2和NO_x排放,及其经济性进行评价。对于大多数采用或不采用净计量策略的建筑类型来说,以满足每小时热需求去运行CCHP系统均可减少CO_2的排放量。该系统能否对这些建筑类型产生经济效益,主要取决于天然气的价格、净计量策略的采用和假定的CCHP系统的成本结构。当建筑物采用净计量策略并且CCHP系统是以满足建筑物每年的最大热需求而运行时,CCHP系统的发电耗水量和NO_x的排放量均有最大限度的减少,尽管此时该运行情景会增加温室气体排放和发电成本。CCHP系统对中型办公楼、大型办公楼和多户型住宅建筑更经济、实用。 展开更多
关键词 电力系统 空气冷却 供热成本 亚特兰大 微型燃气轮机 空气污染 冷热电联供系统 二氧化碳排放
下载PDF
Multi-Objective Optimization Based on Life Cycle Assessment for Hybrid Solar and Biomass Combined Cooling,Heating and Power System
4
作者 LIU Jiejie LI Yao +1 位作者 MENG Xianyang WU Jiangtao 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第3期931-950,共20页
The complementary of biomass and solar energy in combined cooling,heating and power(CCHP)system provides an efficient solution to address the energy crisis and environmental pollutants.This work aims to propose a mult... The complementary of biomass and solar energy in combined cooling,heating and power(CCHP)system provides an efficient solution to address the energy crisis and environmental pollutants.This work aims to propose a multi-objective optimization model based on the life cycle assessment(LCA)method for the optimal design of hybrid solar and biomass system.The life-cycle process of the poly-generation system is divided into six phases to analyze energy consumption and greenhouse gas emissions.The comprehensive performances of the hybrid system are optimized by incorporating the evaluation criteria,including environmental impact in the whole life cycle,renewable energy contribution and economic benefit.The non-dominated sorting genetic algorithmⅡ(NSGA-Ⅱ)with the technique for order preference by similarity to ideal solution(TOPSIS)method is employed to search the Pareto frontier result and thereby achieve optimal performance.The developed optimization methodology is used for a case study in an industrial park.The results indicate that the best performance from the optimized hybrid system is reached with the environmental impact load reduction rate(EILRR)of 46.03%,renewable energy contribution proportion(RECP)of 92.73%and annual total cost saving rate(ATCSR)of35.75%,respectively.By comparing pollutant-eq emissions of different stages,the operation phase emits the largest pollutant followed by the phase of raw material acquisition.Overall,this study reveals that the proposed multi-objective optimization model integrated with LCA method delivers an alternative path for the design and optimization of more sustainable CCHP system. 展开更多
关键词 combined cooling heating and power system solar-biomass multi-objective optimization life cycle assessment optimal design
原文传递
Thermodynamic Analysis of Solid Oxide Fuel Cell Based Combined Cooling,Heating,and Power System Integrated with Solar-Assisted Electrolytic Cell
5
作者 GAO Yuefen YAO Wenqi +1 位作者 WANG Jiangjiang CUI Zhiheng 《Journal of Thermal Science》 SCIE EI CAS CSCD 2023年第1期93-108,共16页
Syngas fuel such as hydrogen and carbon monoxide generated by solar energy is a promising method to use solar energy and overcome its fluctuation effectively.This study proposes a combined cooling,heating,and power sy... Syngas fuel such as hydrogen and carbon monoxide generated by solar energy is a promising method to use solar energy and overcome its fluctuation effectively.This study proposes a combined cooling,heating,and power system using the reversible solid oxide fuel cell assisted by solar energy to produce solar fuel and then supply energy products for users during the period without solar radiation.The system runs a solar-assisted solid oxide electrolysis cell mode and a solid oxide fuel cell mode.The thermodynamic models are constructed,and the energetic and exergetic performances are analyzed.Under the design work conditions,the SOEC mode’s overall system energy and exergy efficiencies are 19.0%and 20.5%,respectively.The electrical,energy and exergy efficiencies in the SOFC mode are 51.4%,71.3%,and 45.2%,respectively.The solid oxide fuel cell accounts for 60.0%of total exergy destruction,caused by the electrochemical reactions’thermodynamic irreversibilities.The increase of operating temperature of solid oxide fuel cell from 800℃to 1050℃rises the exergy and energy efficiencies by 11.3%and 12.3%,respectively.Its pressure from 0.2 to 0.7 MPa improves electrical efficiency by 13.8%while decreasing energy and exergy efficiencies by 5.2%and 6.0%,respectively. 展开更多
关键词 solid oxide electrolysis cell(SOEC) solid oxide fuel cell(SOFC) solar energy combined cooling heatING and power(CCHP) exergy analysis
原文传递
Optimization of Operation Strategies for a Combined Cooling, Heating and Power System based on Adiabatic Compressed Air Energy Storage 被引量:8
6
作者 CHEN Shang ZHU Tong +2 位作者 GAN Zhongxue ZHU Xiaojun LIU Liuchen 《Journal of Thermal Science》 SCIE EI CAS CSCD 2020年第5期1135-1148,共14页
The fluctuations of renewable energy and various energy demands are crucial issues for the optimal design and operation of combined cooling,heating and power(CCHP)system.In this paper,a novel CCHP system is simulated ... The fluctuations of renewable energy and various energy demands are crucial issues for the optimal design and operation of combined cooling,heating and power(CCHP)system.In this paper,a novel CCHP system is simulated with advanced adiabatic compressed air energy storage(AA-CAES)technology as a join to connect with wind energy generation and an internal-combustion engine(ICE).The capital cost of utilities,energy cost,environmental protection cost and primary energy savings ratio(P E S R)are used as system performance indicators.To fulfill the cooling,heating and power requirements of a district and consider the thermal-electric coupling of ICE and AA-CAES in CCHP system,three operation strategies are established to schedule the dispatch of AA-CAES and ICE:ICE priority operation strategy,CAES priority operation strategy and simultaneous operation strategy.Each strategy leads the operation load of AA-CAES or ICE to improve the energy supply efficiency of the system.Moreover,to minimize comprehensive costs and maximize the P E S R,a novel optimization algorithm based on intelligent updating multi-objective differential evolution(MODE)is proposed to solve the optimization model.Considering the multi-interface characteristic and active management ability of the ICE and AA-CAES,the economic benefits and energy efficiency of the three operation strategies are compared by the simulation with the same system configuration.On a typical summer day,the simultaneous strategy is the best solution as the total cost is 3643 USD and the P E S R is 66.1%,while on a typical winter day,the ICE priority strategy is the best solution as the total cost is 4529 USD and the P E S R is 64.4%.The proposed methodology provides the CCHP based AA-CAES system with a better optimized operation. 展开更多
关键词 combined cooling heating and power(CCHP)system advanced adiabatic compressed air energy storage(AA-CAES) OPTIMIZATION
原文传递
Feasibility Analysis of the Operation Strategies for Combined Cooling, Heating and Power Systems (CCHP) based on the Energy-Matching Regime 被引量:1
7
作者 FENG Lejun DAI Xiaoye +1 位作者 MO Junrong SHI Lin 《Journal of Thermal Science》 SCIE EI CAS CSCD 2020年第5期1149-1164,共16页
Although numerous studies have considered the two traditional operation strategies:following the electric load(FEL)and following the thermal load(FTL),for combined cooling,heating,and power(CCHP)systems in different c... Although numerous studies have considered the two traditional operation strategies:following the electric load(FEL)and following the thermal load(FTL),for combined cooling,heating,and power(CCHP)systems in different case studies,there are limited theoretical studies on the quantification methods to assess the feasibility of these two strategies in different load demands scenarios.Therefore,instead of a case study,we have undertaken a theoretical analysis of the suitable application scenarios for FEL and FTL strategies based on the energy-matching performance between systems'provision and users'demands.To compare the calculation models of energy saving rate(ESR)for FEL and FTL strategies in the left and right sub-regions of the energy-supply curve,a comprehensive parameter(^)that combines three inherently influential factors(off-design operation parameter,energy-matching parameter,and install capacity coefficient)is defined to determine the optimal installed capacity and feasibility of FEL or FTL strategies quantitatively.The results indicate that greater value of x contribute to a better energy saving performance,and FEL strategy shows better performance than FTL in most load demands scenarios,and the optimal installed capacity occurs when the load demand points were located in different regions of the energy-supply curve.Finally,taking a hotel in Beijing as an example,the value of the optimal install capacity coefficient is 0.845 and the FEL strategy is also suggested,and compared to the maximum install capacity,the average values of the ESR on a typical summer day,transition season,and winter can be enhanced by 3.9%,8.8%,and 1.89%,respectively. 展开更多
关键词 combined cooling heating and power systems(CCHP) energy-matching performance operation strategies comprehensive parameter energy saving performance
原文传递
Energetic, economic, and environmental analysis of solid oxide fuel cell-based combined cooling, heating, and power system for cancer care hospital
8
作者 Ahmad K.Sleiti Wahib AAl-Ammari +1 位作者 Raiha Arshad Tarek EI Mekkawy 《Building Simulation》 SCIE EI CSCD 2022年第8期1437-1454,共18页
In this study,energetic,economic,and environmental analysis of solid oxide fuel cell-based combined cooling,heating,and power(SOFC-CCHP)system is proposed for a cancer care hospital building.The energy required for th... In this study,energetic,economic,and environmental analysis of solid oxide fuel cell-based combined cooling,heating,and power(SOFC-CCHP)system is proposed for a cancer care hospital building.The energy required for the hospital power,cooling,and heating demands was obtained based on real and detailed field data,which could serve as a reference for future works in the field.These data with a 3D model for the hospital building are constructed and created in eQUEST software to precisely calculate the energy demands of the existing system(baseline case).Then,energetic,economic,and environmental models were developed to compare and assess the performance of the proposed SOFC-CCHP system.The results show that the proposed system can cover about 49% to 77% of the power demand of the hospital with an overall efficiency of 78.3%.Also,the results show that the levelized cost of electricity of the system and its payback period at the designed capacity of the SOFC is 0.087S/kWh and 10 years,respectively.Furthermore,compared to the baseline system of the hospital,the SOFC-CCHP reduces the CO_(2) emission by 89% over the year.The sensitivity analysis showed that a maximum SOFC efficiency of 52%and overall efficiency of 80%are achieved at cell operating temperature of 1027℃ and fuel utilization factor of 0.85. 展开更多
关键词 combined cooling heating and power solid oxide fuel cell hospital power demand CO_(2)emissions levelized cost of electricity(LCOE)
原文传递
A multi agent-based optimal control method for combined cooling and power systems with thermal energy storage
9
作者 Zihao Wang Chaobo Zhang +1 位作者 Hongbo Li Yang Zhao 《Building Simulation》 SCIE EI CSCD 2021年第6期1709-1723,共15页
Combined cooling,heating and power(CCHP)systems have been considered as a potential energy saving technology for buildings due to their high energy efficiency and low carbon emission.Thermal energy storage(TES)can imp... Combined cooling,heating and power(CCHP)systems have been considered as a potential energy saving technology for buildings due to their high energy efficiency and low carbon emission.Thermal energy storage(TES)can improve the energy efficiency of CCHP systems,since they reduce the mismatch between the energy supply and demand.However,it also increases the complexity of operation optimization of CCHP systems.In this study,a multi-agent system(MAS)-based optimal control method is proposed to minimize the operation cost of CCHP systems combined with TES.Four types of agents,i.e.,coordinator agents,building agents,energy management agents and optimization agents,are implemented in the MAS to cooperate with each other.The operation optimization problem is solved by the genetic algorithm.A simulated system is utilized to validate the performance of the proposed method.Results show that the operation cost reductions of 10.0%on a typical summer day and 7.7%on a typical spring day are achieved compared with a rule-based control method.A sensitivity analysis is further performed and results show that the optimal operation cost does not change obviously when the rated capacity of TES exceeds a threshold. 展开更多
关键词 multi-agent systems distributed control-operation optimization demand response combined cooling heating and power system thermal energy storage
原文传递
Liquid Air Energy Storage for Decentralized Micro Energy Networks with Combined Cooling,Heating,Hot Water and Power Supply 被引量:1
10
作者 SHE Xiaohui ZHANG Tongtong +5 位作者 PENG Xiaodong WANG Li TONG Lige LUO Yimo ZHANG Xiaosong DING Yulong 《Journal of Thermal Science》 SCIE EI CAS CSCD 2021年第1期1-17,共17页
Liquid air energy storage(LAES)has been regarded as a large-scale electrical storage technology.In this paper,we first investigate the performance of the current LAES(termed as a baseline LAES)over a far wider range o... Liquid air energy storage(LAES)has been regarded as a large-scale electrical storage technology.In this paper,we first investigate the performance of the current LAES(termed as a baseline LAES)over a far wider range of charging pressure(1 to 21 MPa).Our analyses show that the baseline LAES could achieve an electrical round trip efficiency(e RTE)above 60%at a high charging pressure of 19 MPa.The baseline LAES,however,produces a large amount of excess heat particularly at low charging pressures with the maximum occurred at~1 MPa.Hence,the performance of the baseline LAES,especially at low charging pressures,is underestimated by only considering electrical energy in all the previous research.The performance of the baseline LAES with excess heat is then evaluated which gives a high e RTE even at lower charging pressures;the local maximum of 62%is achieved at~4 MPa.As a result of the above,a hybrid LAES system is proposed to provide cooling,heating,hot water and power.To evaluate the performance of the hybrid LAES system,three performance indicators are considered:nominal-electrical round trip efficiency(ne RTE),primary energy savings and avoided carbon dioxide emissions.Our results show that the hybrid LAES can achieve a high ne RTE between 52%and 76%,with the maximum at~5 MPa.For a given size of hybrid LAES(1 MW×8 h),the primary energy savings and avoided carbon dioxide emissions are up to 12.1 MWh and 2.3 ton,respectively.These new findings suggest,for the first time,that small-scale LAES systems could be best operated at lower charging pressures and the technologies have a great potential for applications in local decentralized micro energy networks. 展开更多
关键词 liquid air energy storage cryogenic energy storage micro energy grids combined heating cooling and power supply heat pump
原文传递
Modelling and optimization of combined heat and power system in microgrid based on renewable energy
11
作者 Ghassan F.Smaisim Azher M.Abed +2 位作者 Salema K.Hadrawi Hasan Sh.Majdi Ali Shamel 《Clean Energy》 EI CSCD 2023年第4期735-746,共12页
Due to the short distance between the sources of production and consumption,microgrids(MGs)have received considerable attention because these systems involve fewer losses and waste less energy.And another advantage of... Due to the short distance between the sources of production and consumption,microgrids(MGs)have received considerable attention because these systems involve fewer losses and waste less energy.And another advantage of MGs is that renewable energy sources can be widely used because these resources are not fully available and can provide a part of the required power.The purpose of this research is to model the MG considering the production sources of microturbines,gas turbines and internal combustion engines.Renewable energies such as wind turbines(WTs)and photovoltaic(PV)cells have been used to provide part of the required power and,because of the lack of access to renewable energy sources at all times,energy reserves such as batteries and fuel cells(FCs)have been considered.The power of the microturbine,gas turbine,internal combustion engine,FC and battery in this system is 162,150,90,100 and 225 kW,respectively.After modelling the studied system,optimization was done using the imperialist competitive algorithm to minimize production costs and provide maximum thermal and electrical loads.The maximum production power for PVs is equal to 0.6860 MWh and at this time this value for WTs is equal to 0.3812 MWh,in which case the excess electricity produced will be sold to the grid. 展开更多
关键词 microgrid energy management system OPTIMIZATION optimal power flow combined heat and power sustainable development
原文传递
Analysis and Economic Evaluation of Hourly Operation Strategy Based on MSW Classification and LNG Multi-Generation System
12
作者 Xueqing Lu Yuetao Shi Jinsong Li 《Energy Engineering》 EI 2023年第6期1325-1352,共28页
In this study,a model of combined cooling,heating and power system with municipal solid waste(MSW)and liquefied natural gas(LNG)as energy sources was proposed and developed based on the energy demand of a large commun... In this study,a model of combined cooling,heating and power system with municipal solid waste(MSW)and liquefied natural gas(LNG)as energy sources was proposed and developed based on the energy demand of a large community,andMSW was classified and utilized.The systemoperated by determining power by heating load,and measures were taken to reduce operating costs by purchasing and selling LNG,natural gas(NG),cooling,heating,and power.Based on this system model,three operation strategies were proposed based on whether MSW was classified and the length of kitchen waste fermentation time,and each strategy was simulated hourly throughout the year.The results showed that the strategy of MSW classified and centralized fermentation of kitchen waste in summer(i.e.,strategy 3)required the least total amount of LNG for the whole year,which was 47701.77 t.In terms of total annual cost expenditure,strategy 3 had the best overall economy,with the lowest total annual expenditure of 2.7730×108 RMB at LNG and NG unit prices of 4 and 4.2 RMB/kg,respectively.The lower heating value of biogas produced by fermentation of kitchen waste from MSW being classified was higher than that of MSW before being classified,so the average annual thermal economy of the operating strategy of MSW being classified was better than that of MSW not being classified.Among the strategies in which MSW was classified and utilized,strategy 3 could better meet the load demand of users in the corresponding season,and thus this strategy had better thermal economy than the strategy of year-round fermentation of kitchen waste(i.e.,strategy 2).The hourly analysis data showed that the net electrical efficiency of the system varies in the same trend as the cooling,heating and power loads in all seasons,while the relationship between the energy utilization efficiency and load varied from season to season.This study can provide guidance for the practical application of MSW being classified in the system. 展开更多
关键词 Municipal solid waste liquefied natural gas energy recovery combined power heating and cooling determining power by heating load net electrical efficiency energy utilization efficiency
下载PDF
Dynamic Simulation and Performance Analysis on Multi-Energy Coupled CCHP System
13
作者 Xueqin Tian Jinfei Sun +5 位作者 Tong Xu Mengran Cui Xinlei Wang Jianxiang Guo De-gejirifu Na Wang 《Energy Engineering》 EI 2022年第2期723-737,共15页
Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matchi... Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matching between supply and demand loads due to the unbalance features of the user’s cooling and heating loads.On the basis of user convenience and wide applicability of clean air energy,this paper tries to put forward a coupled CCHP system with combustion gas turbine and ASHP ordered power by heat,analyze trends of such parameters as gas consumption and power consumption of heat pump in line with adjustment of heating load proportion of combustion gas turbine,and optimize the system ratio in the method of annual costs and energy environmental benefit assessment.Based on the analysis of the hourly simulation and matching characteristics of the cold and hot load of the 100 thousand square meter building,it is found that the annual cost of the air source heat pump is low,but the energy and environmental benefits are poor.It will lead to 6.35%shortage of cooling load in summer.Combined with the evaluation method of primary energy consumption and zero carbon dioxide emission,the coupling system of CHHP and air source heat pump with 41%gas turbine load ratio is the best configuration.This system structure and optimization method can provide some reference for the development of CCHP coupling system. 展开更多
关键词 CCHP(combined cooling heating and power system) ASHP(Air Source heat Pump) annual costs absorption cooling transient simulation
下载PDF
Operation Strategy Analysis and Configuration Optimization of Solar CCHP System
14
作者 Duojin Fan Chengji Shi +1 位作者 Kai Sun Xiaojuan Lu 《Energy Engineering》 EI 2021年第4期1197-1221,共25页
This paper proposed a new type of combined cooling heating and power(CCHP)system,including the parabolic trough solar thermal(PTST)power generation and gas turbine power generation.The thermal energy storage subsystem... This paper proposed a new type of combined cooling heating and power(CCHP)system,including the parabolic trough solar thermal(PTST)power generation and gas turbine power generation.The thermal energy storage subsystem in the PTST unit provides both thermal energy and electrical energy.Based on the life cycle method,the configuration optimization under eight operation strategies is studied with the economy,energy,and environment indicators.The eight operation strategies include FEL,FEL-EC,FEL-TES,FEL-TES&EC,FTL,FTL-EC,FTL-TES,and FTL-TES&EC.The feasibility of each strategy is verified by taking a residential building cluster as an example.The indicators under the optimal configuration of each strategy are compared with that of the separate production(SP)system.The results showed that the PTST-CCHP system improves the environment and energy performance by changing the ratio of thermal energy and electric energy.The environment and energy indicators of FEL-TES&EC are superior to those of FTL-TES&EC in summer,and the results are just the opposite in winter.The initial annual investment of the PTST-CCHP system is higher than that of the SP system,but its economic performance is better than that of the SP system with the increase of life-cycle. 展开更多
关键词 combined cooling heating and power(CCHP)system trough solar thermal power generation operation strategy optimization configuration hill-climbing algorithm(HCA)
下载PDF
Comprehensive power-supply planning for active distribution system considering cooling,heating and power load balance 被引量:24
15
作者 Xinwei SHEN Yingduo HAN +3 位作者 Shouzhen ZHU Jinghong ZHENG Qingsheng LI Jing NONG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2015年第4期485-493,共9页
An active distribution system power-supply planning model considering cooling,heating and power load balance is proposed in this paper.A regional energy service company is assumed to be in charge of the investment and... An active distribution system power-supply planning model considering cooling,heating and power load balance is proposed in this paper.A regional energy service company is assumed to be in charge of the investment and operation for the system in the model.The expansion of substations,building up distributed combined cooling,heating and power(CCHP),gas heating boiler(GHB)and air conditioner(AC)are included as investment planning options.In terms of operation,the load scenarios are divided into heating,cooling and transition periods.Also,the extreme load scene is included to assure the power supply reliability of the system.Numerical results demonstrate the effectiveness of the proposed model and illustrate the economic benefits of applying distributed CCHP in regional power supply on investment and operation. 展开更多
关键词 Active distribution system combined cooling heating and power(CCHP) power-supply planning Load balance
原文传递
Dynamic scheduling of market price-based combined heat–power-constrained renewable microgrid
16
作者 Sunita Shukla Manjaree Pandit 《Clean Energy》 EI CSCD 2023年第4期859-872,共14页
In this paper,a market price-based combined heat–power dynamic dispatch model for a microgrid is presented.The microgrid comprises cogeneration units and wind and solar power-generation units.A battery and a heat sto... In this paper,a market price-based combined heat–power dynamic dispatch model for a microgrid is presented.The microgrid comprises cogeneration units and wind and solar power-generation units.A battery and a heat storage tank are incorporated to optimally balance variations in heat-and-power load demands.The proposed model explores the impact of market prices of electricity,heat supply and load variability on the optimal schedule such that profit maximizes and emission,loss and waste heat are minimized.The Weibull probability distribution function is applied to characterize the uncertain renewable power variable in the model and to find the over-and under-scheduling costs.The problem is solved using an improved differential evolution algorithm in which a fuzzy membership module is appended to obtain a solution having the highest attainment for the selected multiple objectives.The results show that the proposed model can handle uncertain heat–power demand and price scenarios to produce feasible and optimal schedules with owner profits,heat utilization and renewable share varying between 10.55–115.97%,72.51–90.39%and 26.82–38.05%,respectively. 展开更多
关键词 renewable energy combined heat power(CHP) microgrid(MG) economic dispatch MG profit
原文传递
Distributed energy management for interconnected operation of combined heat and power-based microgrids with demand response 被引量:11
17
作者 Nian LIU Jie WANG Lingfeng WANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第3期478-488,共11页
From the perspective of transactive energy, the energy trading among interconnected microgrids(MGs) is promising to improve the economy and reliability of system operations. In this paper, a distributed energy managem... From the perspective of transactive energy, the energy trading among interconnected microgrids(MGs) is promising to improve the economy and reliability of system operations. In this paper, a distributed energy management method for interconnected operations of combined heat and power(CHP)-based MGs with demand response(DR) is proposed. First, the system model of operational cost including CHP, DR, renewable distributed sources, and diesel generation is introduced, where the DR is modeled as a virtual generation unit. Second, the optimal scheduling model is decentralized as several distributed scheduling models in accordance with the number of associated MGs. Moreover, a distributed iterative algorithm based on subgradient with dynamic search direction is proposed. During the iterative process, the information exchange between neighboring MGs is limited to Lagrange multipliers and expected purchasing energy. Finally,numerical results are given for an interconnected MGs system consisting of three MGs, and the effectiveness of the proposed method is verified. 展开更多
关键词 Interconnected microgrids Energy management Distributed optimization Demand response combined heat and power(CHP)
原文传递
含分层储能的冷热电联供系统运行优化
18
作者 高冰 李国翊 +2 位作者 梅晓辉 赵海洲 贾建东 《化学工程》 CSCD 北大核心 2024年第1期88-94,共7页
为提高冷热电联供型微电网对可再生能源的消纳能力,解决源-荷的不确定性使得系统运行稳定性降低的问题,提出含分层储能的三级混合时间尺度滚动优化方法。日前优化目标为日运行成本最低;日内上层以燃料成本和蓄热罐功率变化惩罚成本最低... 为提高冷热电联供型微电网对可再生能源的消纳能力,解决源-荷的不确定性使得系统运行稳定性降低的问题,提出含分层储能的三级混合时间尺度滚动优化方法。日前优化目标为日运行成本最低;日内上层以燃料成本和蓄热罐功率变化惩罚成本最低为目标对冷热能进行优化,下层以电网交互成本和蓄电池功率变化惩罚成本最低为优化目标对电能进行优化;实时电系统反馈以电系统削峰填谷作用量和功率波动量最低为优化目标;得出最优的系统中各设备的出力计划。结果表明:该优化方法和分层储能能够有效达到削峰填谷的作用,各设备功率波动率均处于较低水平;冬季典型日的日运行成本比日前成本有所降低。 展开更多
关键词 冷热电联供型微电网 分层储能 滚动优化 分时间尺度 运行优化
下载PDF
含电动汽车和热电联产的区域微电网参与电网辅助服务调度
19
作者 刘杨 刘天羽 《计算机应用与软件》 北大核心 2024年第4期67-72,105,共7页
如今,在发达的特大城市,越来越多的分布式电源和电动汽车接入微电网。该文提出一个区域微电网,由一个热电联供系统和一系列插电式电动汽车组成。其主要目的是通过将PEV整合为快速响应存储来提供辅助服务和充分利用可再生能源提高系统的... 如今,在发达的特大城市,越来越多的分布式电源和电动汽车接入微电网。该文提出一个区域微电网,由一个热电联供系统和一系列插电式电动汽车组成。其主要目的是通过将PEV整合为快速响应存储来提供辅助服务和充分利用可再生能源提高系统的能源利用率和经济效益。停车场会聚集形成电力电子设备集群,并与CHP签订双边合同,以便能够参与调节电力市场。提出改进的乌鸦算法,对问题进行求解。通过MATLAB对算法进行数值仿真表明,如果区域微电网参与电力市场调控,每兆瓦的经济价值显著提高,总利润增加。 展开更多
关键词 插电式电动汽车 区域微电网 电力市场 热电联供系统 乌鸦算法
下载PDF
考虑风电消纳的热电联供微电网系统协同优化策略研究
20
作者 卢晓东 徐彤宇 +2 位作者 王明伟 陈剑 杨玉龙 《吉林电力》 2024年第2期1-4,19,共5页
针对新能源的波动性和随机性使其在电力系统中的消纳存在困难,弃风、弃光现象频发,提出一种考虑风电消纳的热电联供微电网源-荷-储协同优化技术。以微网的运行总成本及风电消纳水平为优化目标,在调节热电联供机组出力的同时,结合蓄热式... 针对新能源的波动性和随机性使其在电力系统中的消纳存在困难,弃风、弃光现象频发,提出一种考虑风电消纳的热电联供微电网源-荷-储协同优化技术。以微网的运行总成本及风电消纳水平为优化目标,在调节热电联供机组出力的同时,结合蓄热式电锅炉储热系统及储能系统的灵活调节能力,进行微电网运行的协同优化。所提出模型通过非支配排序遗传算法(non-dominated sorting genetic algorithm,NSGA-Ⅱ)进行求解,并基于某园区微电网数据进行了验证,相较于单一灵活性资源的优化调度,所提的源-荷-储协同优化模型能够在兼顾成本的同时保证较高的风电消纳水平。 展开更多
关键词 新能源 风电消纳 热电联供 微电网 蓄热式电锅炉 NSGA-Ⅱ
下载PDF
上一页 1 2 36 下一页 到第
使用帮助 返回顶部