Five phospholipids in human placenta were determined by phosphorus 31 nuclear magnetic resonance(^(31)P NMR)spectroscopy and thin-layer chromatography(TLC) scanning combined with the corrective method of absorbance pr...Five phospholipids in human placenta were determined by phosphorus 31 nuclear magnetic resonance(^(31)P NMR)spectroscopy and thin-layer chromatography(TLC) scanning combined with the corrective method of absorbance proportional coefficient. The NMR spectrometer used this investigation was a Bruker AM-500 spectrometer operating at 202.4 MHz for ^(31)P chemical shifts are relative to 85% phosphoric acid. TIC was carried out by silica gel H plate developed in chloroform-methanol-glacial acetic acid-ethanol-water(25:4:6:2:0.5),with Vaskovsky reagent as colour -developing agent of phospholipids.展开更多
The exciton states of semiconducting carbon nanotubes are calculated by a tight-binding model supplemented by Coulomb interactions under the combined effect of uniaxial strain and magnetic field. It is found that the ...The exciton states of semiconducting carbon nanotubes are calculated by a tight-binding model supplemented by Coulomb interactions under the combined effect of uniaxial strain and magnetic field. It is found that the excitation energies and absorption spectra of zigzag tubes(11,0) and(10,0) show opposite trends with the strain under the action of the magnetic field. For the(11,0) tube, the excitation energy decreases with the increasing uniaxial strain, with a splitting appearing in the absorption spectra. For the(10,0) tube, the variation trend firstly increases and then decreases, with a reversal point appearing in the absorption spectra. More interesting,at the reversal point the intensity of optical absorption is the largest because of the degeneracy of the two bands nearest to the Fermi Level, which is expected to be observed in the future experiment. The similar variation trend is also exhibited in the binding energy for the two kinds of semiconducting tubes.展开更多
To address the alignment and measuring force problem in the segmenting-stitching technique for the circularity metrology of small cylindrical workpieces(diameter less than 1.5 mm and length less than 10 mm),a magnet c...To address the alignment and measuring force problem in the segmenting-stitching technique for the circularity metrology of small cylindrical workpieces(diameter less than 1.5 mm and length less than 10 mm),a magnet combination jig method is proposed.A small round magnet is attached between the round magnetic jig and small cylinder,and the other end of the small cylindrical workpiece is attached to some cylindrical magnets.Thus,the smaller cylinder can be put in the V-groove and measured successfully with the magnet combination.For verifying the advantage of the magnet combination jig,four measurement quality evaluations are proposed:the circumferential deviation of neighbor arc contours,radial deviation of neighbor arc contours,angle of inclination between the V-groove and small cylinder,and curvature of the obtained arc.The results show that the matching coefficient is enhanced by 98%,the Euclidean distance of overlap parts of neighbor arc contours is reduced by 68%,the position error is reduced 27%,and the average curvature of the arc contours is improved.It can be concluded that the measuring quality can be enhanced prominently by this magnet combination method for the segmenting-stitching method.展开更多
文摘Five phospholipids in human placenta were determined by phosphorus 31 nuclear magnetic resonance(^(31)P NMR)spectroscopy and thin-layer chromatography(TLC) scanning combined with the corrective method of absorbance proportional coefficient. The NMR spectrometer used this investigation was a Bruker AM-500 spectrometer operating at 202.4 MHz for ^(31)P chemical shifts are relative to 85% phosphoric acid. TIC was carried out by silica gel H plate developed in chloroform-methanol-glacial acetic acid-ethanol-water(25:4:6:2:0.5),with Vaskovsky reagent as colour -developing agent of phospholipids.
基金Supported by the National Natural Science Foundation of China under Grant No 11304378the Fundamental Research Funds for the Central Universities under Grant No 2017XKQY093
文摘The exciton states of semiconducting carbon nanotubes are calculated by a tight-binding model supplemented by Coulomb interactions under the combined effect of uniaxial strain and magnetic field. It is found that the excitation energies and absorption spectra of zigzag tubes(11,0) and(10,0) show opposite trends with the strain under the action of the magnetic field. For the(11,0) tube, the excitation energy decreases with the increasing uniaxial strain, with a splitting appearing in the absorption spectra. For the(10,0) tube, the variation trend firstly increases and then decreases, with a reversal point appearing in the absorption spectra. More interesting,at the reversal point the intensity of optical absorption is the largest because of the degeneracy of the two bands nearest to the Fermi Level, which is expected to be observed in the future experiment. The similar variation trend is also exhibited in the binding energy for the two kinds of semiconducting tubes.
基金supported by the National Defense Basic Scientific Research Program of China(Grant numbers JCKY2019427D002).
文摘To address the alignment and measuring force problem in the segmenting-stitching technique for the circularity metrology of small cylindrical workpieces(diameter less than 1.5 mm and length less than 10 mm),a magnet combination jig method is proposed.A small round magnet is attached between the round magnetic jig and small cylinder,and the other end of the small cylindrical workpiece is attached to some cylindrical magnets.Thus,the smaller cylinder can be put in the V-groove and measured successfully with the magnet combination.For verifying the advantage of the magnet combination jig,four measurement quality evaluations are proposed:the circumferential deviation of neighbor arc contours,radial deviation of neighbor arc contours,angle of inclination between the V-groove and small cylinder,and curvature of the obtained arc.The results show that the matching coefficient is enhanced by 98%,the Euclidean distance of overlap parts of neighbor arc contours is reduced by 68%,the position error is reduced 27%,and the average curvature of the arc contours is improved.It can be concluded that the measuring quality can be enhanced prominently by this magnet combination method for the segmenting-stitching method.