Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to loca...Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%.展开更多
分析了目前在实际光纤纵差保护中应用的数据同步方法的缺点,尤其是SDH(synchronous digital hierar-chy)光纤自愈环网中收发数据路由不一致导致线路两侧保护装置采样数据不同步问题,提出了一种适用于超、特高压长线路光纤纵差保护的采...分析了目前在实际光纤纵差保护中应用的数据同步方法的缺点,尤其是SDH(synchronous digital hierar-chy)光纤自愈环网中收发数据路由不一致导致线路两侧保护装置采样数据不同步问题,提出了一种适用于超、特高压长线路光纤纵差保护的采样数据同步方法,即基于时钟校正法,并通过精确线路模型的在线计算对时钟做进一步补偿校正的方法.EMTP仿真验证该方法的误差小于0.5μs.理论分析和仿真结果证明了该方法保证线路两侧保护装置采样数据同步的有效性及应用于超、特高压长线的可行性.展开更多
随着静态同步串联补偿器(static synchronous series compensator,SSSC)的不断发展及应用,其构成和控制的复杂化对传统超高压输电线路保护提出了挑战,需对含SSSC的输电线路保护原理进行深入的研究。为此,运用串补输电线路的频域模型,分...随着静态同步串联补偿器(static synchronous series compensator,SSSC)的不断发展及应用,其构成和控制的复杂化对传统超高压输电线路保护提出了挑战,需对含SSSC的输电线路保护原理进行深入的研究。为此,运用串补输电线路的频域模型,分析了串补输电线路故障时故障电流的频率特征。分析结果表明,当串补线路区内、外发生故障时,保护安装处获得的频率分量的含量明显不同。对串补线路区内、外故障时的暂态高频信号频率成分的复杂度进行仿真分析,根据信号复杂度的变化特征,提出一种适应于串补线路的单端暂态量保护新方案。仿真结果表明,该方案性能不受故障类型、故障位置、过渡电阻、故障初始相角和串补度的影响,且具有良好的适应性和灵敏性。展开更多
针对500 k V伊敏—冯屯串补电容器补偿装置(简称伊冯串补)运行过程中出现的故障,如阀基电子设备VBE电源板故障导致旁路断路器合闸、次同步谐振SSR保护误动作、断路器三相不一致保护动作、金属氧化物限压器MOV保护动作造成旁路断路器合...针对500 k V伊敏—冯屯串补电容器补偿装置(简称伊冯串补)运行过程中出现的故障,如阀基电子设备VBE电源板故障导致旁路断路器合闸、次同步谐振SSR保护误动作、断路器三相不一致保护动作、金属氧化物限压器MOV保护动作造成旁路断路器合闸等故障,根据伊冯串补的原理和结构特殊性,结合伊冯串补保护动作和录波数据,分析故障产生的原因,通过更换故障元件、优化保护程序、修改保护动作逻辑、加强设备制造工艺和设备维护等措施,提高了串补的抗干扰能力和运行稳定性,现场运行情况表明:采取的改进措施会使伊冯串补存在的隐患得到根本性消除,同时证明了防范措施的正确性和有效性。展开更多
文摘Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%.
文摘分析了目前在实际光纤纵差保护中应用的数据同步方法的缺点,尤其是SDH(synchronous digital hierar-chy)光纤自愈环网中收发数据路由不一致导致线路两侧保护装置采样数据不同步问题,提出了一种适用于超、特高压长线路光纤纵差保护的采样数据同步方法,即基于时钟校正法,并通过精确线路模型的在线计算对时钟做进一步补偿校正的方法.EMTP仿真验证该方法的误差小于0.5μs.理论分析和仿真结果证明了该方法保证线路两侧保护装置采样数据同步的有效性及应用于超、特高压长线的可行性.
文摘随着静态同步串联补偿器(static synchronous series compensator,SSSC)的不断发展及应用,其构成和控制的复杂化对传统超高压输电线路保护提出了挑战,需对含SSSC的输电线路保护原理进行深入的研究。为此,运用串补输电线路的频域模型,分析了串补输电线路故障时故障电流的频率特征。分析结果表明,当串补线路区内、外发生故障时,保护安装处获得的频率分量的含量明显不同。对串补线路区内、外故障时的暂态高频信号频率成分的复杂度进行仿真分析,根据信号复杂度的变化特征,提出一种适应于串补线路的单端暂态量保护新方案。仿真结果表明,该方案性能不受故障类型、故障位置、过渡电阻、故障初始相角和串补度的影响,且具有良好的适应性和灵敏性。
文摘针对500 k V伊敏—冯屯串补电容器补偿装置(简称伊冯串补)运行过程中出现的故障,如阀基电子设备VBE电源板故障导致旁路断路器合闸、次同步谐振SSR保护误动作、断路器三相不一致保护动作、金属氧化物限压器MOV保护动作造成旁路断路器合闸等故障,根据伊冯串补的原理和结构特殊性,结合伊冯串补保护动作和录波数据,分析故障产生的原因,通过更换故障元件、优化保护程序、修改保护动作逻辑、加强设备制造工艺和设备维护等措施,提高了串补的抗干扰能力和运行稳定性,现场运行情况表明:采取的改进措施会使伊冯串补存在的隐患得到根本性消除,同时证明了防范措施的正确性和有效性。