Under the assumption that' is a strongly convex weakly Khler Finsler metric on a complex manifold M, we prove that F is a weakly complex Berwald metric if and only if F is a real Landsberg metric.This result toget...Under the assumption that' is a strongly convex weakly Khler Finsler metric on a complex manifold M, we prove that F is a weakly complex Berwald metric if and only if F is a real Landsberg metric.This result together with Zhong(2011) implies that among the strongly convex weakly Kahler Finsler metrics there does not exist unicorn metric in the sense of Bao(2007). We also give an explicit example of strongly convex Kahler Finsler metric which is simultaneously a complex Berwald metric, a complex Landsberg metric,a real Berwald metric, and a real Landsberg metric.展开更多
This paper reports a study of complex focussing acoustic fields of a convex phased array probe widely used in ultrasonic diagnostic B-scanner. The time delay necessary for electronic focussing and for geometric focuss...This paper reports a study of complex focussing acoustic fields of a convex phased array probe widely used in ultrasonic diagnostic B-scanner. The time delay necessary for electronic focussing and for geometric focussing of complex focussing is given. By means of Helmholtz's integral formula, the expressions of acoustic fields were obtained for the electronic focussing and complex focussing.With Simpson's numerical integral, a great deal of computations was carried out with an 86 / 330 computer. By means of using different parameters, an optimum focal range and beam width of a 4 sequences electronic and complex focussing acoustic system was selected. With an EUB-40 ultrasound diagnostic B-scanner produced by the Hitachi company, the lateral focussing acoustic field and lateral resolution in an echoic tank were photographed by latticing method and the experimental result is consistent with the theory.展开更多
基金supported by Program for New Century Excellent Talents in University (Grant No. NCET-13-0510)National Natural Science Foundation of China(Grant Nos. 11271304,10971170, 11171277,11571288,11461064 and 11671330)+1 种基金the Fujian Province Natural Science Funds for Distinguished Young Scholar (Grant No.2013J06001)the Scientific Research Foundation for the Returned Overseas Chinese Scholars,State Education Ministry
文摘Under the assumption that' is a strongly convex weakly Khler Finsler metric on a complex manifold M, we prove that F is a weakly complex Berwald metric if and only if F is a real Landsberg metric.This result together with Zhong(2011) implies that among the strongly convex weakly Kahler Finsler metrics there does not exist unicorn metric in the sense of Bao(2007). We also give an explicit example of strongly convex Kahler Finsler metric which is simultaneously a complex Berwald metric, a complex Landsberg metric,a real Berwald metric, and a real Landsberg metric.
文摘This paper reports a study of complex focussing acoustic fields of a convex phased array probe widely used in ultrasonic diagnostic B-scanner. The time delay necessary for electronic focussing and for geometric focussing of complex focussing is given. By means of Helmholtz's integral formula, the expressions of acoustic fields were obtained for the electronic focussing and complex focussing.With Simpson's numerical integral, a great deal of computations was carried out with an 86 / 330 computer. By means of using different parameters, an optimum focal range and beam width of a 4 sequences electronic and complex focussing acoustic system was selected. With an EUB-40 ultrasound diagnostic B-scanner produced by the Hitachi company, the lateral focussing acoustic field and lateral resolution in an echoic tank were photographed by latticing method and the experimental result is consistent with the theory.