1 Scope This standard specifies the definition, classification, technical requirements, test methods, inspection rules, packing, marking, transportation and quality certificate of corundum block containing plastic ph...1 Scope This standard specifies the definition, classification, technical requirements, test methods, inspection rules, packing, marking, transportation and quality certificate of corundum block containing plastic phase.展开更多
The present study deals with development of conceptual proof for jute rubber based flexible composite block to completely arrest the projectile impacting the target at high velocity impact of 400 m/s through numerical...The present study deals with development of conceptual proof for jute rubber based flexible composite block to completely arrest the projectile impacting the target at high velocity impact of 400 m/s through numerical simulation approach using finite element(FE)method.The proposed flexible composite blocks of repeating jute/rubber/jute(JRJ)units are modelled with varying thickness from 30 mm to 120 mm in increments of 30 mm and impacted by flat(F),ogival(O)and hemispherical(HS)shaped projectiles.All the considered projectiles are impacted with proposed flexible composite blocks of different thicknesses and the penetration behaviour of the projectile in each case is studied.The penetration depth of the projectile in case of partially penetrated cases are considered and the effect of thickness and projectile shape on percentage of penetration depth is statistically analyzed using Taguchi’s design of experiments(DOE).Results reveal that the though proposed flexible composite block with thickness of 90 mm is just sufficient to arrest the complete penetration of the projectile,considering the safety issues,it is recommended to use the flexible composite with thickness of 120 mm.The nature of damage caused by the projectile in the flexible composite is also studied.Statistical studies show that thickness of the block plays a prominent role in determining the damage resistance of the flexible composite.展开更多
Ceramic fiber,a kind of furnace lining material, is widely utilized in industrial furnaces. Fiber blocks can be made into various shapes. They have advantages of low thermal conductivity, low density and light weight ...Ceramic fiber,a kind of furnace lining material, is widely utilized in industrial furnaces. Fiber blocks can be made into various shapes. They have advantages of low thermal conductivity, low density and light weight for the development of industrial furnaces, This paper, taking a continuous annealing furnace as an example, describes the application of ceramic fiber blocks in the furnace and the installation methods. The temperatures of the furnace wall with different linings are analyzed. In the furnace design or the renovation of the existing furnaces, lining with ceramic fiber blocks is the preferred solution.展开更多
文摘1 Scope This standard specifies the definition, classification, technical requirements, test methods, inspection rules, packing, marking, transportation and quality certificate of corundum block containing plastic phase.
文摘The present study deals with development of conceptual proof for jute rubber based flexible composite block to completely arrest the projectile impacting the target at high velocity impact of 400 m/s through numerical simulation approach using finite element(FE)method.The proposed flexible composite blocks of repeating jute/rubber/jute(JRJ)units are modelled with varying thickness from 30 mm to 120 mm in increments of 30 mm and impacted by flat(F),ogival(O)and hemispherical(HS)shaped projectiles.All the considered projectiles are impacted with proposed flexible composite blocks of different thicknesses and the penetration behaviour of the projectile in each case is studied.The penetration depth of the projectile in case of partially penetrated cases are considered and the effect of thickness and projectile shape on percentage of penetration depth is statistically analyzed using Taguchi’s design of experiments(DOE).Results reveal that the though proposed flexible composite block with thickness of 90 mm is just sufficient to arrest the complete penetration of the projectile,considering the safety issues,it is recommended to use the flexible composite with thickness of 120 mm.The nature of damage caused by the projectile in the flexible composite is also studied.Statistical studies show that thickness of the block plays a prominent role in determining the damage resistance of the flexible composite.
文摘Ceramic fiber,a kind of furnace lining material, is widely utilized in industrial furnaces. Fiber blocks can be made into various shapes. They have advantages of low thermal conductivity, low density and light weight for the development of industrial furnaces, This paper, taking a continuous annealing furnace as an example, describes the application of ceramic fiber blocks in the furnace and the installation methods. The temperatures of the furnace wall with different linings are analyzed. In the furnace design or the renovation of the existing furnaces, lining with ceramic fiber blocks is the preferred solution.