Indoor Surveillance of Airborne Fungi Contaminating Intensive Care Units and Operation Rooms in Assiut University Hospitals, Egypt
1
作者 M. Bassam Aboul-Nasr Abdel-Naser A. Zohri Enas Mahmoud Amer 《Journal of Health Science》 2014年第1期20-27,共8页
Mycoflora of atmospheric air and dust samples collected from air conditioning systems in 12 of each I.C.U. (intensive care units) and O.R. (operation rooms) were tested using settle and dilution plate methods on f... Mycoflora of atmospheric air and dust samples collected from air conditioning systems in 12 of each I.C.U. (intensive care units) and O.R. (operation rooms) were tested using settle and dilution plate methods on four types of agar media and incubated at 25℃. Forty-five fungal species representing 23 genera were isolated and identified. The most prevalent genera recorded were Cladosporium, Aspergillus, Penicillium and Fusarium. The total colony forming units of airborne fungi recovered in I.C.U. and O.R. ranged between 31.13-49.61 colonies/m3 on the four types of media usedl The fungal total catch of the dust samples collected from the air conditioning system filters in I.C.U. and O.R. were ranged from 65.5-170 colonies/mg dust. Since, the interest to replace synthetic xenobiotics by natural compounds with low environmental persistence and biodegradable to control such airborne fungal contaminants is needed. In this respect, essential oils showed to possess a broad spectrum of antifungal activity. Fungal static ability of six oils was tested on 30 different fungal isolates. Vapors of common thyme oil exhibited the strongest inhibitory effects on the tested isolates, whereas the headspace vapors of blue gum and ginger had no inhibitory effects on the tested fungal isolates. These data revealed that the air conditioning systems may be an important source of contamination in I.C.U. and O.R. of Assiut university hospitals. Thus, patients may be in risk of being exposed to contaminated atmospheric air by opportunistic fungi and the use of essential oils as an alternative option to control hospital wards from fungal contaminants needs further studies. 展开更多
关键词 air conditions airborne fungi intensive care units operation rooms and volatile oils.
下载PDF
地铁车站弱电设备间设备发热量确定方法
2
作者 王艳 篮杰 +1 位作者 李国栋 王海涛 《暖通空调》 2024年第2期114-120,共7页
介绍了一种地铁车站弱电设备间设备发热量确定新方法,该方法利用弱电设备发热量实测数据与模型预测数据相互验证,可以有效提高弱电设备发热量确定结果的准确性。研究了室内气温、地铁是否运营、设备额定功率和车站类型等因素对设备发热... 介绍了一种地铁车站弱电设备间设备发热量确定新方法,该方法利用弱电设备发热量实测数据与模型预测数据相互验证,可以有效提高弱电设备发热量确定结果的准确性。研究了室内气温、地铁是否运营、设备额定功率和车站类型等因素对设备发热量的影响。研究结果表明:基于间接测量和预测模型的地铁车站弱电设备间设备发热量确定方法可以提高和保障设备发热量计算结果的准确性;室内气温会显著影响设备外表面和围护结构内表面温度及围护结构内表面热流密度,但对设备外表面热流密度的影响较小;地铁是否运营对弱电设备间设备发热量有较大影响,地铁运营期间设备发热量大于非运营期间;设备额定功率对弱电设备间设备发热量峰值有较大影响,车站类型和建筑面积对设备发热量峰值的影响很小。 展开更多
关键词 地铁车站 弱电设备间 空调负荷 设备发热量 影响因素
下载PDF
基于实测数据的地铁车站强电设备发热量影响因素分析
3
作者 王艳 付维纲 +3 位作者 孙心明 夏三县 篮杰 王海涛 《节能》 2024年第3期26-29,共4页
如果地铁车站强电设备管理用房的空调系统设计缺少可靠的设备发热量参数,不利于地铁空调系统的优化设计和节能减排。提出一种地铁车站强电设备管理用房空调设备发热量计算与分析方法,并在郑州地区4种地铁车站中进行应用,研究室内空气温... 如果地铁车站强电设备管理用房的空调系统设计缺少可靠的设备发热量参数,不利于地铁空调系统的优化设计和节能减排。提出一种地铁车站强电设备管理用房空调设备发热量计算与分析方法,并在郑州地区4种地铁车站中进行应用,研究室内空气温度、地铁是否运营、设备额定功率和车站类型等因素对地铁强电设备管理用房设备发热量的影响。结果显示:室内气温虽然对设备外表面温度有较大影响,但是对设备外表面热流密度和设备发热量的影响较小。地铁运营期间的设备发热量大于非营运期间的设备发热量,设备发热量低于设备额定功率。 展开更多
关键词 地铁车站 强电设备间 设备发热量 空调系统
下载PDF
基站空调在640层CT数据机房的使用效果
4
作者 刘辉 赵冰 《医疗装备》 2024年第10期11-14,共4页
目的探讨基站空调在640层CT数据机房的使用效果。方法640层CT正常开机时,分别记录并比较基站空调和普通空调开启后数据机房温度由28℃降至24℃所需时间、正常运行必需后勤维护项目及次数、整体价格。结果室外温度为-5~30℃时,两种空调... 目的探讨基站空调在640层CT数据机房的使用效果。方法640层CT正常开机时,分别记录并比较基站空调和普通空调开启后数据机房温度由28℃降至24℃所需时间、正常运行必需后勤维护项目及次数、整体价格。结果室外温度为-5~30℃时,两种空调达到设定温度所需时间比较,差异无统计学意义(P>0.05),后勤维护项目次数相同;室外环境温度为31~42℃时,基站空调机房降温时间短于普通空调(P<0.05);普通空调需完成后勤维护项目一2次和项目二1次,基站空调需完成项目一2次;在室外环境温度为-6~-15℃时,普通空调故障停机,基站空调达到设定温度需要(12.4±1.5)min;基站空调整体价格高于普通空调;基站空调的整机性价比、操作使用、降温效率、故障报警和环境影响评分高于普通空调(P<0.05)。结论基站空调虽整体价格偏贵,但制冷速度快、可靠性高、维护简单,更适用于640层CT数据机房。 展开更多
关键词 640层CT 基站空调 数据机房
下载PDF
基于盲板的地板送风式数据中心热管理与能效案例研究 被引量:1
5
作者 高启明 张羽 +1 位作者 冯秀敏 张忠斌 《制冷学报》 CAS CSCD 北大核心 2024年第3期129-142,共14页
数据中心机房空调设备长期运行,每年需对其性能进行测试和评估,以确保安全高效运行。针对机架内服务器布局、盲板结构以及工况适应性进行实测,研究了封闭式冷通道地板下送风式数据中心的热环境;并通过热性能指标和能效指标,对该数据中... 数据中心机房空调设备长期运行,每年需对其性能进行测试和评估,以确保安全高效运行。针对机架内服务器布局、盲板结构以及工况适应性进行实测,研究了封闭式冷通道地板下送风式数据中心的热环境;并通过热性能指标和能效指标,对该数据中心的安全性和能效进行了全年评估。结果表明:在冷通道中间区域推荐安装功率为2 kW以上的机架;机架间隙处安装盲板后,能够促进服务器内部冷气流循环,减少热气流的回流干扰,最大出口温度降低3.32℃,出口平均速度降低约24%;夏季工况时,该数据中心的PUE、WUE、CUE分别约为1.2、3.5、0.84,且WUE呈现出较强的季节性,冬季工况时,自由冷却可有效降低数据中心的能耗。此外,数据中心冷通道末端的机架过热问题显著,其中16个机架的机柜冷却指数均低于90%,热损失较高。 展开更多
关键词 数据中心 送风方式 机房空调 热性能评价指标 能源效率
下载PDF
某调度通信楼空调系统节能减碳改造设计实践 被引量:1
6
作者 曹涛 徐鸿 +2 位作者 马友才 胡志高 王聪 《暖通空调》 2024年第6期59-64,共6页
重点介绍了某调度通信楼空调系统的节能减碳改造设计,通过综合运用余热回收、可再生能源、固体蓄热、高效制冷机房等多项技术,构建了安全可靠、绿色低碳、高效节能的空调系统。采用HDY-SMAD空调负荷计算及分析软件模拟了建筑物全年的空... 重点介绍了某调度通信楼空调系统的节能减碳改造设计,通过综合运用余热回收、可再生能源、固体蓄热、高效制冷机房等多项技术,构建了安全可靠、绿色低碳、高效节能的空调系统。采用HDY-SMAD空调负荷计算及分析软件模拟了建筑物全年的空调能耗,并对优化前后空调系统的运行能耗和碳排放进行了测算。结果显示,优化方案空调系统全年节约电量100万kW·h,全年碳减排573 t,节能减碳效果显著。 展开更多
关键词 调度通信楼 空调 节能减碳 余热回收 可再生能源 固体蓄热 高效制冷机房 能耗模拟
下载PDF
包装顶空气氛和相对湿度对葡萄常温货架期和品质的影响
7
作者 杜笑然 石志敏 +3 位作者 赵立群 钱井 廖大智 李东立 《保鲜与加工》 CAS 北大核心 2024年第5期30-39,共10页
为分析气调透湿袋和多效抗菌纸对葡萄在常温下的保鲜效果,在室温条件(26℃和相对湿度(RH)70%)下使用PE保鲜袋(PE袋)、自制的透湿性薄膜袋(A袋)以及A袋内加入自制的乙烯吸附复合抗菌纸(A-P)3种被动气调(MA)保鲜方案,并研究包装顶空气氛... 为分析气调透湿袋和多效抗菌纸对葡萄在常温下的保鲜效果,在室温条件(26℃和相对湿度(RH)70%)下使用PE保鲜袋(PE袋)、自制的透湿性薄膜袋(A袋)以及A袋内加入自制的乙烯吸附复合抗菌纸(A-P)3种被动气调(MA)保鲜方案,并研究包装顶空气氛、顶空相对湿度以及乙烯吸附纸对‘巨峰’葡萄采后贮藏品质的影响。结果表明:A-P组建立的气调气氛(11.5%CO_(2)、14.5%O2和RH 78%)下‘巨峰’葡萄的果梗褐变率、落粒率和霉变率均最低,可滴定酸含量和可溶性固形物含量水平较高;A袋的顶空气氛(9.17%O2、25.4%CO_(2))抑制葡萄的褐变及霉变较为理想,但是由于相对湿度较高导致落粒;PE袋中较高O2(18.5%)和较低CO_(2)(2.2%),特别是高湿度(RH 99%)环境导致葡萄大量霉变与褐变,货架期仅3 d,裸放的CK组3 d时产生大量褐变,失去商业价值。综上,自制抗菌纸与透湿性薄膜的组合有利于葡萄的常温贮藏,延长货架期。A-P包装为葡萄的常温保鲜提供了新的方案。 展开更多
关键词 葡萄 气调包装 常温保鲜 抗菌包装 乙烯吸收
下载PDF
市域车客室空调通风系统仿真与优化研究
8
作者 刘智远 孙伟 +2 位作者 易柯 曹小林 窦雨凡 《暖通空调》 2024年第7期147-151,33,共6页
以某市域车客室空调通风系统为研究对象,提出了将客室、送风系统、回风系统、废气排风系统和新风系统整体耦合的新仿真模型,使仿真边界条件设置贴合实际工程。利用ANSYS Fluent软件,对市域车空调通风系统的气流组织和传热状况进行了仿... 以某市域车客室空调通风系统为研究对象,提出了将客室、送风系统、回风系统、废气排风系统和新风系统整体耦合的新仿真模型,使仿真边界条件设置贴合实际工程。利用ANSYS Fluent软件,对市域车空调通风系统的气流组织和传热状况进行了仿真计算与优化。结果表明:优化前2台空调机组4个回风口的回风量分别为0.24、0.26、0.35、0.19 kg/s,回风量分布不均匀;废气排风道过于窄小,导致废气排风系统阻力高达629 Pa。鉴于此,对客室回风结构与废气排风结构进行了优化研究,优化后最大回风量与最小回风量仅相差0.05 kg/s,客室到废气排风出口流动阻力降低至120 Pa。客室内大部分区域温度范围为24~26℃,客室内部人员主要活动范围处于微风速,乘坐舒适性提升显著。本研究可以为市域车空调通风系统的优化设计提供依据。 展开更多
关键词 市域车 客室 空调通风系统 结构优化 气流组织 仿真分析
下载PDF
某安保中心数据机房空调系统设计 被引量:1
9
作者 刘杰 侯青燕 《建筑节能(中英文)》 CAS 2024年第3期104-108,共5页
基于北京市某安保中心数据机房空调系统设计,介绍了数据机房室内温湿度的设计要求及空调负荷计算方法。分析了水冷冷水系统及自然冷却风冷冷水系统两种空调冷源形式的特点及优缺点并对A级机房应急冷源的设计进行了介绍。分析对比了数据... 基于北京市某安保中心数据机房空调系统设计,介绍了数据机房室内温湿度的设计要求及空调负荷计算方法。分析了水冷冷水系统及自然冷却风冷冷水系统两种空调冷源形式的特点及优缺点并对A级机房应急冷源的设计进行了介绍。分析对比了数据机房封闭冷通道及封闭热通道的优缺点及适用性,通过气流组织分析模拟验证了封闭冷通道送风可使冷、热通道内的温度达到设计要求。针对空调冷冻水系统,提出了确定空调冷冻水供回水温度的方法,介绍了能够保证空调水系统安全运行的管路设计方法。总结了数据中心空调节能设计措施,指出了设计时应注意的事项。 展开更多
关键词 数据机房 机房空调 空调负荷计算 恒温恒湿 封闭冷通道 节能措施
下载PDF
Deep learning analysis of smart meter data from a small sample of room air conditioners facilitates routine assessment of their operational efficiency
10
作者 Weiqi Wang Zixuan Zhou +2 位作者 Sybil Derrible Yangqiu Song Zhongming Lu 《Energy and AI》 EI 2024年第2期42-52,共11页
Room air conditioners (RACs) are crucial household appliances that consume substantial amounts of electricity. Their efficiency tends to deteriorate over time, resulting in unnecessary energy wastage. Smart meters hav... Room air conditioners (RACs) are crucial household appliances that consume substantial amounts of electricity. Their efficiency tends to deteriorate over time, resulting in unnecessary energy wastage. Smart meters have become popular to monitor electricity use of home appliances, offering underexplored opportunities to evaluate RAC operational efficiency. Traditional supervised data-driven analysis methods necessitate a large sample size of RACs and their efficiency, which can be challenging to acquire. Additionally, the prevalence of zero values when RACs are off can skew training. To overcome these challenges, we assembled a dataset comprising a limited number of window-type RACs with measured operational efficiencies from 2021. We devised an intuitive zero filter and resampling protocol to process smart meter data and increase training samples. A deep learning-based encoder–decoder model was developed to evaluate RAC efficiency. Our findings suggest that our protocol and model accurately classify and regress RAC operational efficiency. We verified the usefulness of our approach by evaluating the RACs replaced in 2022 using 2022 smart meter data. Our case study demonstrates that repairing or replacing an inefficient RAC can save electricity by up to 17 %. Overall, our study offers a potential energy conservation solution by leveraging smart meters for regularly assessing RAC operational efficiency and facilitating smart preventive maintenance. 展开更多
关键词 room air conditioning Operational energy efficiency Smart meter Deep learning Smart preventive maintenance
原文传递
地铁通风空调系统新技术及对东莞地铁适应性分析
11
作者 章燕 李文菁 《机电工程技术》 2024年第9期243-248,265,共7页
地铁通风空调系统运行能耗通常超地铁总能耗的50%以上,因此地铁通风空调系统具有较大的节能空间。从国内地铁通风空调系统的现状及问题切入,阐述了进一步优化地铁通风空调系统的必要性。针对国内在优化地铁通风空调领域的一些新技术与... 地铁通风空调系统运行能耗通常超地铁总能耗的50%以上,因此地铁通风空调系统具有较大的节能空间。从国内地铁通风空调系统的现状及问题切入,阐述了进一步优化地铁通风空调系统的必要性。针对国内在优化地铁通风空调领域的一些新技术与新产品,对以下几方面进行了深入研究:磁悬浮离心机的优势和获得广泛推广的现状;蒸发冷空调出现的契机、发展历史和碰到的困难;高效制冷机房的构成及如何实现整体提高机房能效ERRa值;精细化设计与施工需重点关注的问题、解决措施和实际效果。并对东莞地区进行了适应性分析,提出选用磁悬浮制冷主机,建设高能效机房,谨慎选择蒸发冷空调,以及更精细化设计与施工等措施来优化东莞地铁通风空调系统,对未来推动建设技术先进创新竞争力强的中国地铁具有积极的意义。 展开更多
关键词 地铁通风空调 磁悬浮离心机 蒸发冷制冷机 高能效机房 精细化设计与施工
下载PDF
一种用于一般手术室的新型空调系统
12
作者 吴丹芸 孙先景 高建国 《暖通空调》 2024年第10期165-172,共8页
提出了一种用于一般手术室的新型空调系统,即空气消毒屏+多联空调系统。该系统简单、易施工,造价较低,运维简单。通过气流模拟,对比了该系统与净化空调系统的温度场和速度场,并进行了方案优化。结果表明,该空调系统可以满足温度场和速... 提出了一种用于一般手术室的新型空调系统,即空气消毒屏+多联空调系统。该系统简单、易施工,造价较低,运维简单。通过气流模拟,对比了该系统与净化空调系统的温度场和速度场,并进行了方案优化。结果表明,该空调系统可以满足温度场和速度场需求,形成较好的气流组织,能够大幅提升室内空气质量,适于在一般手术室中使用。 展开更多
关键词 手术室 空气消毒屏 多联空调系统 气流模拟 净化空调系统 方案优化 温度场 速度场
下载PDF
夏热冬暖地区空调制冷机房发展现状研究
13
作者 宁振兴 易检长 谢玉军 《建筑节能(中英文)》 CAS 2024年第1期65-69,共5页
国内高效空调机房建设相关技术和相关标准研究如火如荼,但目前厦门市尚未发布公共建筑高效空调制冷机房建设与能效评价相关标准。厦门市乃至夏热冬暖地区的既有公共建筑空调制冷机房系统能效水平具体情况到底如何,新建公共建筑高效空调... 国内高效空调机房建设相关技术和相关标准研究如火如荼,但目前厦门市尚未发布公共建筑高效空调制冷机房建设与能效评价相关标准。厦门市乃至夏热冬暖地区的既有公共建筑空调制冷机房系统能效水平具体情况到底如何,新建公共建筑高效空调制冷机房系统能效建设可达到什么水平,如何规范厦门市乃至夏热冬暖地区高效空调制冷机房系统能效评价等一系列问题摆在我们面前。为解决上述问题,采用实地调查、线上调研、文献查阅相结合的方法,从国家政策、标准发布、典型项目能效水平调研三个方面开展了相关工作,为引导未来厦门市高效空调制冷机房建设与能效评价提供基础支撑. 展开更多
关键词 厦门市 高效空调制冷机房 现状研究
下载PDF
某数据中心精密空调调适案例
14
作者 赵泽 关德常 +5 位作者 周砜 王浩 胡宇阳 崔杰 党鹏飞 杨新春 《暖通空调》 2024年第10期124-127,共4页
以某大型金融业数据中心为研究对象,以实现风量供需匹配、降低末端精密空调风机能耗为目的,开展了精密空调优化调适。首先,通过分析精密空调历史运行数据,总结运行特点,挖掘节能潜力;其次,制定调适方案与应急回退方案,优化精密空调运行... 以某大型金融业数据中心为研究对象,以实现风量供需匹配、降低末端精密空调风机能耗为目的,开展了精密空调优化调适。首先,通过分析精密空调历史运行数据,总结运行特点,挖掘节能潜力;其次,制定调适方案与应急回退方案,优化精密空调运行参数与控制逻辑,改善机房内气流组织;最后,分析IT设备进风口温度变化与精密空调节能效果。结果表明,调适后IT机房局部热点减少,且精密空调能耗降幅达50%以上。 展开更多
关键词 数据中心 调适 运维 IT机房 精密空调 最小送风量 风量供需匹配 气流组织优化
下载PDF
某客运站中央空调高效机房设计与研究
15
作者 刘林 《制冷与空调(四川)》 2024年第3期394-398,415,共6页
中央空调系统在现代客运站的应用日益广泛,成为确保乘客舒适度和站内环境质量的重要组成部分。然而,随着客运站规模的扩大和功能的多样化,传统的中央空调系统在能效和运行管理方面面临诸多挑战。旨在探讨客运站中央空调高效机房的设计... 中央空调系统在现代客运站的应用日益广泛,成为确保乘客舒适度和站内环境质量的重要组成部分。然而,随着客运站规模的扩大和功能的多样化,传统的中央空调系统在能效和运行管理方面面临诸多挑战。旨在探讨客运站中央空调高效机房的设计与研究,从系统设计和控制策略两个方面进行深入分析,提出了一套切实可行的高效机房设计方案。研究结果表明,通过科学地设计和优化可以显著提升系统的能效,降低运行成本。 展开更多
关键词 中央空调系统 客运站 高效机房 系统设计 控制策略
下载PDF
一种实现无线设备机房空调节能的智能化方法
16
作者 葛澍 郭若沛 +2 位作者 刘扬 杨泽一 凌济民 《电信工程技术与标准化》 2024年第2期1-4,共4页
在无线主设备机房的总能耗当中,空调能耗占据着较大比重,而目前对机房空调的管控较为粗犷,造成较大的能源耗费,不符合当前国家绿色节能发展战略。本文对无线机房情况进行详细分析,设计出一套针对无线机房空调的节能方法,包括数据采集分... 在无线主设备机房的总能耗当中,空调能耗占据着较大比重,而目前对机房空调的管控较为粗犷,造成较大的能源耗费,不符合当前国家绿色节能发展战略。本文对无线机房情况进行详细分析,设计出一套针对无线机房空调的节能方法,包括数据采集分析、场景划分、时序预测与策略生成、后期监控等完整生产流程的方案,实现空调节能配置的实时化、精细化与智能化。该方案试点效果显著,具有很高的推广应用价值。 展开更多
关键词 空调节能 实时预测 无线设备机房 智能化
下载PDF
天津某地铁车站高效制冷机房的节能技术分析研究
17
作者 潘帅方 《工程建设与设计》 2024年第1期80-83,共4页
对天津某地铁车站的空调制冷系统进行节能技术分析,通过优化空调系统设计和高效设备选型,结合风水联动智能系统控制风-水系统高效运行,实现制冷机房的高能效、低能耗,相比常规地铁车站制冷系统的能效有大幅提升,制冷机房的EERS能达到5.... 对天津某地铁车站的空调制冷系统进行节能技术分析,通过优化空调系统设计和高效设备选型,结合风水联动智能系统控制风-水系统高效运行,实现制冷机房的高能效、低能耗,相比常规地铁车站制冷系统的能效有大幅提升,制冷机房的EERS能达到5.3以上,制冷系统的耗电量显著减少,约节省能耗40%。 展开更多
关键词 高效制冷机房 风水联动智能控制系统 节能
下载PDF
提高净化手术室洁净度的改造措施分析——以复旦大学附属眼耳鼻喉科医院洁净手术室改建为例
18
作者 周成 《现代工程科技》 2024年第1期77-80,共4页
为提高净化手术室的洁净度,运用模块化手术室、集成空调系统和净化机组,大大提高了工程效益,强化送回风管道、内密封的施工工序和质量控制,确保了净化系统在调试和检测环节均达到设计要求,为类似改建工程提供理论依据与实践标准。
关键词 净化手术室 洁净度 模块化手术室 空调系统集成 密封
下载PDF
中央空调系统诊断分析应用研究
19
作者 李梅 《区域供热》 2024年第1期25-32,共8页
通过测试某办公楼大厅中央空调系统,检测环境品质,发现该系统存在人机温度不适中、空气清新度差、运行能耗较高等问题。论述了通过系统诊断及数据分析,以寻求问题症结的过程,在最低成本控制的条件下,采用风平衡调试等系统运行策略,改善... 通过测试某办公楼大厅中央空调系统,检测环境品质,发现该系统存在人机温度不适中、空气清新度差、运行能耗较高等问题。论述了通过系统诊断及数据分析,以寻求问题症结的过程,在最低成本控制的条件下,采用风平衡调试等系统运行策略,改善大厅气流组织,解决了某大厅环境温度不适中的问题,并有效提供了一套“人机同室”的中央空调系统运行策略。该策略既降低了系统能耗,又提高了大厅内的环境舒适度和工作人员满意度,为“人机同室”室内温度难以调节等问题贡献了研究资料,具有一定的推广应用价值。 展开更多
关键词 中央空调系统 风平衡调试 人机同室
下载PDF
空调设备噪声自动测试消声室声学设计分析
20
作者 肖春鹏 《模具制造》 2024年第8期195-197,共3页
以空调为分析对象,在空调运行期间,空调的噪声是影响空调服务能力的关键。因此,要展开空调设备的噪声测试。在测试时,必须完成空调设备噪声测试室的声学设计,要求经过声学设计后能满足空调设备的噪声测试。再结合测试结果实现空调设备... 以空调为分析对象,在空调运行期间,空调的噪声是影响空调服务能力的关键。因此,要展开空调设备的噪声测试。在测试时,必须完成空调设备噪声测试室的声学设计,要求经过声学设计后能满足空调设备的噪声测试。再结合测试结果实现空调设备的噪声控制,促使空调设施能满足使用需求,提升空调的可靠性和服务性。 展开更多
关键词 空调设备 噪声测试室 声学设计
下载PDF