期刊文献+
共找到216,129篇文章
< 1 2 250 >
每页显示 20 50 100
Study on sex differences and potential clinical value of threedimensional computerized tomography pelvimetry in rectal cancer patients
1
作者 Xiao-Cong Zhou Fei-Yue Ke +2 位作者 Gaurav Dhamija Hao Chen Qiang Wang 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第3期773-786,共14页
BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampe... BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampers the establishment of consistent conclusions.AIM To comprehensively assess 16 pelvic and 7 soft tissue parameters through computerized tomography(CT)-based three-dimensional(3D)reconstruction,providing a strong theoretical basis to address challenges in laparoscopic rectal cancer radical surgery.METHODS We analyzed data from 218 patients who underwent radical laparoscopic surgery for rectal cancer,and utilized CT data for 3D pelvic reconstruction.Specific anatomical points were carefully marked and measured using advanced 3D modeling software.To analyze the pelvic and soft tissue parameters,we emp-loyed statistical methods including paired sample t-tests,Wilcoxon rank-sum tests,and correlation analysis.RESULTS The investigation highlighted significant sex disparities in 14 pelvic bone parameters and 3 soft tissue parameters.Males demonstrated larger measurements in pelvic depth and overall curvature,smaller measurements in pelvic width,a larger mesorectal fat area,and a larger anterior-posterior abdominal diameter.By contrast,females exhibited wider pelvises,shallower depth,smaller overall curvature,and an increased amount of subcutaneous fat tissue.However,there were no significant sex differences observed in certain parameters such as sacral curvature height,superior pubococcygeal diameter,rectal area,visceral fat area,waist circumference,and transverse abdominal diameter.CONCLUSION The reconstruction of 3D CT data enabled accurate pelvic measurements,revealing significant sex differences in both pelvic and soft tissue parameters.This study design offer potential in predicting surgical difficulties and creating personalized surgical plans for male rectal cancer patients with a potentially“difficult pelvis”,ultimately improving surgical outcomes.Further research and utilization of these parameters could lead to enhanced surgical methods and patient care in laparoscopic rectal cancer radical surgery. 展开更多
关键词 computerized tomography Rectal cancer Three-dimensional reconstruction PELVIMETRY Sex differences
下载PDF
Multidetector computer tomography and magnetic resonance imaging of double superior mesenteric veins:A case report
2
作者 Wei Tang Song Peng 《World Journal of Clinical Cases》 SCIE 2024年第17期3265-3270,共6页
BACKGROUND This study aimed to describe the findings of double superior mesenteric veins(SMVs),a rare anatomical variation,on multidetector computer tomography(MDCT)and magnetic resonance imaging(MRI)images.CASE SUMMA... BACKGROUND This study aimed to describe the findings of double superior mesenteric veins(SMVs),a rare anatomical variation,on multidetector computer tomography(MDCT)and magnetic resonance imaging(MRI)images.CASE SUMMARY We describe the case of a 34-year-old male,who underwent both MDC and MRI examinations of the upper abdomen because of liver cirrhosis.MDCT and MRI angiography images of the upper abdomen revealed an anatomic variation of the superior mesenteric vein(SMV),the double SMVs.CONCLUSION The double SMVs are a congenital abnormality without potential clinical manifestation.Physicians need to be aware of this anatomical variation during abdominal surgery to avoid iatrogenic injury. 展开更多
关键词 Superior mesenteric vein Anatomic variation Magnetic resonance imaging Multidetector computer tomography Case report
下载PDF
Computerized tomography-guided therapeutic percutaneous puncture catheter drainage-combined with somatostatin for severe acute pancreatitis: An analysis of efficacy and safety
3
作者 Xue-Lan Zheng Wan-Ling Li +1 位作者 Yan-Ping Lin Ting-Long Huang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期59-66,共8页
BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to impr... BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to improve treatment efficacy.AIM To evaluate the efficacy and safety of computerized tomography-guided the-rapeutic percutaneous puncture catheter drainage(CT-TPPCD)combined with somatostatin(SS)in the treatment of SAP.METHODS Forty-two SAP patients admitted to The Second Affiliated Hospital of Fujian Medical University from June 2020 to June 2023 were selected.On the basis of routine treatment,20 patients received SS therapy(control group)and 22 patients were given CT-TPPCD plus SS intervention(research group).The efficacy,safety(pancreatic fistula,intra-abdominal hemorrhage,sepsis,and organ dysfunction syndrome),abdominal bloating and pain relief time,bowel recovery time,hospital stay,inflammatory indicators(C-reactive protein,interleukin-6,and pro-calcitonin),and Acute Physiology and Chronic Health Evaluation(APACHE)II score of both groups were evaluated for comparison.RESULTS Compared with the control group,the research group had a markedly higher total effective rate,faster abdominal bloating and pain relief and bowel recovery,INTRODUCTION Pancreatitis,an inflammatory disease occurring in the pancreatic tissue,is classified as either acute or chronic and is associated with high morbidity and mortality,imposing a socioeconomic burden[1,2].The pathogenesis of this disease involves early protease activation,activation of nuclear factor kappa-B-related inflammatory reactions,and infiltration of immune cells[3].Severe acute pancreatitis(SAP)is a serious condition involving systemic injury and subsequent possible organ failure,accounting for 20%of all acute pancreatitis cases[4].SAP is also characterized by rapid onset,critical illness and unsatisfactory prognosis and is correlated with serious adverse events such as systemic inflammatory response syn-drome and acute lung injury,threatening the health of patients[5,6].Therefore,timely and effective therapeutic inter-ventions are of great significance for improving patient prognosis and ensuring therapeutic effects.Somatostatin(SS),a peptide hormone that can be secreted by endocrine cells and the central nervous system,is in-volved in the regulatory mechanism of glucagon and insulin synthesis in the pancreas[7].It has complex and pleiotropic effects on the gastrointestinal tract,which can inhibit the release of gastrointestinal hormones and negatively modulate the exocrine function of the stomach,pancreas and bile,while exerting a certain influence on the absorption of the di-gestive system[8,9].SS has shown certain clinical effectiveness when applied to SAP patients and can regulate the severity of SAP and immune inflammatory responses,and this regulation is related to its influence on leukocyte apoptosis and adhesion[10,11].Computerized tomography-guided therapeutic percutaneous puncture catheter drainage(CT-TPPCD)is a surgical procedure to collect lesion fluid and pus samples from necrotic lesions and perform puncture and drainage by means of CT image examination and precise positioning[12].In the research of Liu et al[13],CT-TPPCD applied to pa-tients undergoing pancreatic surgery contributes to not only good curative effects but also a low surgical risk.Baudin et al[14]also reported that CT-TPPCD has a clinical success rate of 64.6%in patients with acute infectious necrotizing pan-creatitis,with nonfatal surgery-related complications found in only two cases,suggesting that this procedure is clinically effective and safe in the treatment of the disease.In light of the limited studies on the efficacy and safety of SS plus CT-TPPCD in SAP treatment,this study performed a relevant analysis to improve clinical outcomes in SAP patients. 展开更多
关键词 computerized tomography guidance Therapeutic percutaneous puncture catheter drainage SOMATOSTATIN Severe acute pancreatitis Efficacy and safety
下载PDF
Deep learning-based inpainting of saturation artifacts in optical coherence tomography images 被引量:2
4
作者 Muyun Hu Zhuoqun Yuan +2 位作者 Di Yang Jingzhu Zhao Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期1-10,共10页
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ... Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness. 展开更多
关键词 Optical coherence tomography saturation artifacts deep learning image inpainting.
下载PDF
Multilocular thymic cysts can be easily misdiagnosed as malignant tumor on computer tomography:A case report 被引量:2
5
作者 Jun Sun Qing-Ning Yang +5 位作者 Yi Guo Ping Zeng Long-Yan Ma Ling-Wen Kong Bo-Ying Zhao Chuan-Ming Li 《World Journal of Clinical Cases》 SCIE 2024年第8期1474-1480,共7页
BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with t... BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with transparent liquid.CASE SUMMARY We report on a 39-year-old male with a cystic-solid mass in the anterior mediastinum.Computer tomography(CT)imaging showed that the mass was irregular with unclear boundaries.After injection of contrast agent,there was a slight enhancement of stripes and nodules.According to CT findings,it was diagnosed as thymic cancer.CONCLUSION After surgery,MTC accompanied by bleeding and infection was confirmed by pathological examination.The main lesson of this case was that malignant thymic tumor and MTC of the anterior mediastinum sometimes exhibit similar CT findings.Caution is necessary in clinical work to avoid misdiagnosis. 展开更多
关键词 Multilocular thymic cyst computer tomography MISDIAGNOSIS HEMORRHAGE INFEctION Case report
下载PDF
Glaucoma surgery experiments using digital microscope-integrated optical coherence tomography and OCT-compatible instruments 被引量:1
6
作者 Tianliang Jiang Jinyu Fan +2 位作者 Ning Tang Yi He Guohua Shi 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第5期105-113,共9页
There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)... There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)system and several custom-made OCT-compatible instruments for glaucoma surgery.Sixteen ophthalmologists were asked to perform trabeculectomy and canaloplasty on live porcine eyes using the system and instruments.After surgery,a subjective feedback survey about the user experience was taken.The experiment results showed that our system can help surgeons easily locate important tissue structures during surgery.The custom-made instruments also solved the shadowing problem in OCT imaging.Surgeons preferred to use the system in their future practice. 展开更多
关键词 Microscope-integrated optical coherence tomography Oct-compatible instruments glaucoma surgery TRABECULEctOMY CANALOPLASTY
下载PDF
Double contrast-enhanced ultrasonography improves diagnostic accuracy of T staging compared with multi-detector computed tomography in gastric cancer patients 被引量:1
7
作者 Yan-Fen Xu Hui-Yun Ma +4 位作者 Gui-Ling Huang Yu-Ting Zhang Xue-Yan Wang Ming-Jie Wei Xiao-Qing Pei 《World Journal of Gastroenterology》 SCIE CAS 2024年第23期3005-3015,共11页
BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and ... BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and third for mortality.Knowledge of the invasive depth of the tumor is vital to treatment decisions.AIM To evaluate the diagnostic performance of double contrast-enhanced ultrasonography(DCEUS)for preoperative T staging in patients with GC by comparing with multi-detector computed tomography(MDCT).METHODS This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023.Patients underwent DCEUS,including ultrasonography(US)and intravenous contrast-enhanced ultrasonography(CEUS),and MDCT examinations for the assessment of preoperative T staging.Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual.The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard.RESULTS A total of 229 patients with GC(80 T1,33 T2,59 T3 and 57 T4)were included.Overall accuracies were 86.9%for DCEUS and 61.1%for MDCT(P<0.001).DCEUS was superior to MDCT for T1(92.5%vs 70.0%,P<0.001),T2(72.7%vs 51.5%,P=0.041),T3(86.4%vs 45.8%,P<0.001)and T4(87.7%vs 70.2%,P=0.022)staging of GC.CONCLUSION DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT,and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making. 展开更多
关键词 Double contrast-enhanced ultrasonography Multi-detector computed tomography Gastric cancer T staging
下载PDF
Intravascular photoacoustic and optical coherence tomography imaging dual-mode system for detecting spontaneous coronary artery dissection: A feasibility study 被引量:1
8
作者 Yongwei Wang Yuyang Wan Zhongjiang Chen 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期77-86,共10页
In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary ... In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications. 展开更多
关键词 Spontaneous coronary artery dissection(SCAD) intravascular optical coherence tomography(IVOct) intravascular photoacoustic imaging(IVPAI)
下载PDF
A machine learning-based strategy for predicting the mechanical strength of coral reef limestone using X-ray computed tomography
9
作者 Kai Wu Qingshan Meng +4 位作者 Ruoxin Li Le Luo Qin Ke ChiWang Chenghao Ma 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第7期2790-2800,共11页
Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL... Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL samples were utilized for training the support vector machine(SVM)-,random forest(RF)-,and back propagation neural network(BPNN)-based models,respectively.Simultaneously,the machine learning model was embedded into genetic algorithm(GA)for parameter optimization to effectively predict uniaxial compressive strength(UCS)of CRL.Results indicate that the BPNN model with five hidden layers presents the best training effect in the data set of CRL.The SVM-based model shows a tendency to overfitting in the training set and poor generalization ability in the testing set.The RF-based model is suitable for training CRL samples with large data.Analysis of Pearson correlation coefficient matrix and the percentage increment method of performance metrics shows that the dry density,pore structure,and porosity of CRL are strongly correlated to UCS.However,the P-wave velocity is almost uncorrelated to the UCS,which is significantly distinct from the law for homogenous geomaterials.In addition,the pore tensor proposed in this paper can effectively reflect the pore structure of coral framework limestone(CFL)and coral boulder limestone(CBL),realizing the quantitative characterization of the heterogeneity and anisotropy of pore.The pore tensor provides a feasible idea to establish the relationship between pore structure and mechanical behavior of CRL. 展开更多
关键词 Coral reef limestone(CRL) Machine learning Pore tensor X-ray computed tomography(ct)
下载PDF
Gates joint locally connected network for accurate and robust reconstruction in optical molecular tomography
10
作者 Minghua Zhao Yahui Xiao +2 位作者 Jiaqi Zhang Xin Cao Lin Wang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期11-22,共12页
Optical molecular tomography(OMT)is a potential pre-clinical molecular imaging technique with applications in a variety of biomedical areas,which can provide non-invasive quantitative three-dimensional(3D)information ... Optical molecular tomography(OMT)is a potential pre-clinical molecular imaging technique with applications in a variety of biomedical areas,which can provide non-invasive quantitative three-dimensional(3D)information regarding tumor distribution in living animals.The construction of optical transmission models and the application of reconstruction algorithms in traditional model-based reconstruction processes have affected the reconstruction results,resulting in problems such as low accuracy,poor robustness,and long-time consumption.Here,a gates joint locally connected network(GLCN)method is proposed by establishing the mapping relationship between the inside source distribution and the photon density on surface directly,thus avoiding the extra time consumption caused by iteration and the reconstruction errors caused by model inaccuracy.Moreover,gates module was composed of the concatenation and multiplication operators of three different gates.It was embedded into the network aiming at remembering input surface photon density over a period and allowing the network to capture neurons connected to the true source selectively by controlling three different gates.To evaluate the performance of the proposed method,numerical simulations were conducted,whose results demonstrated good performance in terms of reconstruction positioning accuracy and robustness. 展开更多
关键词 Optical molecular tomography gates module positioning accuracy ROBUSTNESS
下载PDF
Energy spectrum computed tomography multi-parameter imaging in preoperative assessment of vascular and neuroinvasive status in gastric cancer
11
作者 Jing Wang Jian-Cheng Liang +1 位作者 Fa-Te Lin Jun Ma 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第8期2511-2520,共10页
BACKGROUND Vascular and nerve infiltration are important indicators for the progression and prognosis of gastric cancer(GC),but traditional imaging methods have some limitations in preoperative evaluation.In recent ye... BACKGROUND Vascular and nerve infiltration are important indicators for the progression and prognosis of gastric cancer(GC),but traditional imaging methods have some limitations in preoperative evaluation.In recent years,energy spectrum computed tomography(CT)multiparameter imaging technology has been gradually applied in clinical practice because of its advantages in tissue contrast and lesion detail display.AIM To explore and analyze the value of multiparameter energy spectrum CT imaging in the preoperative assessment of vascular invasion(LVI)and nerve invasion(PNI)in GC patients.METHODS Data from 62 patients with GC confirmed by pathology and accompanied by energy spectrum CT scanning at our hospital between September 2022 and September 2023,including 46 males and 16 females aged 36-71(57.5±9.1)years,were retrospectively collected.The patients were divided into a positive group(42 patients)and a negative group(20 patients)according to the presence of LVI/PNI.The CT values(CT40 keV,CT70 keV),iodine concentration(IC),and normalized IC(NIC)of lesions in the upper energy spectrum CT images of the arterial phase,venous phase,and delayed phase 40 and 70 keV were measured,and the slopes of the energy spectrum curves[K(40-70)]from 40 to 70 keV were calculated.Arterial Core Tip:To investigate the application value of multiparameter energy spectrum computed tomography(CT)imaging in the preoperative assessment of vascular and nerve infiltration in patients with gastric cancer(GC).The imaging data of GC patients were retrospectively analyzed to evaluate the accuracy and sensitivity of CT for identifying and quantifying vascular and nerve infiltration and for comparison with postoperative pathological results.The purpose of this study was to verify the clinical feasibility and potential advantages of multiparameter energy spectrum CT imaging in guiding preoperative diagnosis and treatment decision-making and to provide a new imaging basis for improving the diagnostic accuracy and prognosis of GC patients. 展开更多
关键词 tomography X-ray computer Energy spectrum computed tomography Gastric cancer Vascular invasion Nerve invasion Cross-sectional study
下载PDF
The risk of prostate cancer on incidental finding of an avid prostate uptake on 2-deoxy-2-[^(18)F]fluoro-D-glucose positron emission tomography/computed tomography for non-prostate cancer-related pathology:A single centre retrospective study
12
作者 Anthony Franklin Troy Gianduzzo +7 位作者 Boon Kua David Wong Louise McEwan James Walters Rachel Esler Matthew J.Roberts Geoff Coughlina John W.Yaxley 《Asian Journal of Urology》 CSCD 2024年第1期33-41,共9页
Objective:To review the risk of prostate cancer(PCa)in men with incidentally reported increased intraprostatic uptake at 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography/computed tomography(18F-FDG PET/CT)... Objective:To review the risk of prostate cancer(PCa)in men with incidentally reported increased intraprostatic uptake at 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography/computed tomography(18F-FDG PET/CT)ordered at Department of Urology,The Wesley Hospital,Brisbane,QLD,Australia for non-PCa related pathology.Methods:Retrospective analysis of consecutive men between August 2014 and August 2019 presenting to a single institution for 18F-FDG PET/CT for non-prostate related conditions was conducted.Men were classified as benign,indeterminate,or malignant depending of the results of prostate-specific antigen(PSA),PSA velocity,biopsy histopathology,and three-Tesla(3 T)multiparametric MRI(mpMRI)Prostate Imaging Reporting and Data System score,or gallium-68-prostate-specific membrane antigen(68Ga-PSMA)PET/CT results.Results:Three percent(273/9122)of men demonstrated 18F-FDG avidity within the prostate.Eighty-five percent(231/273)were further investigated,including with PSA tests(227/231,98.3%),3 T mpMRI(68/231,29.4%),68Ga-PSMA PET/CT(33/231,14.3%),and prostate biopsy(57/231,24.7%).Results were considered benign in 130/231(56.3%),indeterminate in 31/231(13.4%),and malignant in 70/231(30.3%).PCa was identified in 51/57(89.5%)of the men who proceeded to biopsy,including 26/27(96.3%)men with Prostate Imaging Reporting and Data System scores 4-5 mpMRI and six men with a positive 68Ga-PSMA PET/CT.The most common Gleason score on biopsy was greater than or equal to 4+5(14/51,27.5%).68Ga-PSMA PET/CT was concordant with the 18F-FDG findings in 26/33(78.8%).All 13 men with a positive concordant 18F-FDG,3 T mpMRI,and 68Ga-PSMA PET/CT had PCa on biopsy.There was no statistically significant difference in the 18F-FDG maximum standardized uptake value between the benign or malignant groups(5.7 vs.6.1;p=0.580).Conclusion:In this study,after an incidental finding of an avid intraprostatic lesion on 18F-FDG PET/CT,70 of the 231 cases(30.3%;0.8%of the entire cohort)had results consistent with PCa,most commonly as Gleason score greater than or equal to 4+5 disease.Unless there is limited life expectancy due to competing medical co-morbidity,men with an incidental finding of intraprostatic uptake on 18F-FDG should be further investigated using principles of PCa detection. 展开更多
关键词 Prostatecancer Positionemission tomography Multiparametric magneticresonance imaging Prostatebiopsy
下载PDF
Triple-path feature transform network for ring-array photoacoustic tomography image reconstruction
13
作者 Lingyu Ma Zezheng Qin +1 位作者 Yiming Ma Mingjian Sun 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期23-40,共18页
Photoacoustic imaging(PAI)is a noninvasive emerging imaging method based on the photoacoustic effect,which provides necessary assistance for medical diagnosis.It has the characteristics of large imaging depth and high... Photoacoustic imaging(PAI)is a noninvasive emerging imaging method based on the photoacoustic effect,which provides necessary assistance for medical diagnosis.It has the characteristics of large imaging depth and high contrast.However,limited by the equipment cost and reconstruction time requirements,the existing PAI systems distributed with annular array transducers are difficult to take into account both the image quality and the imaging speed.In this paper,a triple-path feature transform network(TFT-Net)for ring-array photoacoustic tomography is proposed to enhance the imaging quality from limited-view and sparse measurement data.Specifically,the network combines the raw photoacoustic pressure signals and conventional linear reconstruction images as input data,and takes the photoacoustic physical model as a prior information to guide the reconstruction process.In addition,to enhance the ability of extracting signal features,the residual block and squeeze and excitation block are introduced into the TFT-Net.For further efficient reconstruction,the final output of photoacoustic signals uses‘filter-then-upsample’operation with a pixel-shuffle multiplexer and a max out module.Experiment results on simulated and in-vivo data demonstrate that the constructed TFT-Net can restore the target boundary clearly,reduce background noise,and realize fast and high-quality photoacoustic image reconstruction of limited view with sparse sampling. 展开更多
关键词 Deep learning feature transformation image reconstruction limited-view measurement photoacoustic tomography.
下载PDF
Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
14
作者 Shan Ma Cheng Li +6 位作者 Jing Sun Jun Yang Kai Wen Xi-Teng Chen Fang-Yu Zhao Rong-Yu Gao Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1437-1446,共10页
AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with catarac... AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with cataract.METHODS:This prospective case series was conducted at Tianjin Medical University Eye Hospital.In total,212 eyes from 212 patients scheduled for phacoemulsification were included.Eyes were evaluated preoperatively using two SSOCT devices(IOLMaster700 and CASIA2)and Scheimpflug tomography(Pentacam).Central corneal thickness(CCT),anterior chamber depth(ACD),aqueous depth(AQD),white-to-white distance(WTW),flat simulated keratometry(Kf),steep simulated keratometry(Ks),mean keratometry(Km),and total corneal keratometry(TKm)were measured.Intraclass correlation coefficient(ICC),95%confidence intervals(CI)and limits of agreement(LoA)widths were conducted to assess differences and correlations between devices.RESULTS:All parameters,except for Ks,were significantly different.Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam.LoA widths of all paired comparisons for Ks were>0.80 D.Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam,other Pearson’s coefficients between devices showed a strong correlation(all r>0.95).The ICC of WTW(ICC=0.438,95%CI 0.167-0.625)showed poor reliability.The reliability of CCT,ACD,and AQD was excellent(all ICC>0.95),whereas that of TKm was good(ICC=0.827,95%CI 0.221-0.939).A significant linear correlation was also observed among devices.CONCLUSION:The ocular parameters derived from the use of IOLMaster700,CASIA2,and Pentacam exhibit significant discrepancies;as such,measurements from these devices should not be deemed as interchangeable. 展开更多
关键词 ocular parameters swept-source optical coherence tomography CATARAct
下载PDF
Computed tomography imaging and clinical significance of bacterium-positive pulmonary tuberculosis complicated with diabetes
15
作者 Xue-Song Rong Chao Yao 《World Journal of Clinical Cases》 SCIE 2024年第20期4230-4238,共9页
BACKGROUND The increasing prevalence of tuberculosis(TB)and diabetes on a global scale poses a significant health challenge,particularly due to their co-occurrence,which amplifies the severity,recurrence and mortality... BACKGROUND The increasing prevalence of tuberculosis(TB)and diabetes on a global scale poses a significant health challenge,particularly due to their co-occurrence,which amplifies the severity,recurrence and mortality rates associated with both conditions.This highlights the need for further investigation into their interrelationship.AIM To explore the computed tomography(CT)imaging and clinical significance of bacterium-positive pulmonary TB(PTB)combined with diabetes.METHODS There were 50 patients with bacterium-positive PTB and diabetes,and 50 with only bacterium-positive PTB.The latter were designated as the control group.The CT imaging of the two groups of patients was compared,including lesion range,shape,density and calcification.RESULTS No significant differences were observed in age,gender,smoking and drinking history,high blood pressure,hyperlipidemia and family genetic factors between the groups.However,compared to the patients diagnosed solely with simple bacterium-positive PTB,those with concurrent diabetes showed a wider range of lesions and more complex and diverse morphology on CT images.Among them,intrapulmonary tuberculosis lesions were often accompanied by manifestations of pulmonary infection,such as cavity formation and bronchiectasis.At the same time,diabetes-related signs were often seen on CT images,such as pulmonary infection combined with diabetic pulmonary lesions.Logistic regression analysis identified age and medical history as significant factors influencing the degree of pulmonary infection and CT imaging outcomes in patients with both TB and diabetes.This suggests that older age and specific medical histories may increase the risk or severity of pulmonary damage in these patients.CONCLUSION CT imaging reveals more complex lesions in PTB patients with diabetes,emphasizing the need for careful evaluation and comprehensive analysis to enhance diagnostic accuracy. 展开更多
关键词 Bacteria-positive pulmonary tuberculosis DIABETES Computed tomography BRONCHIEctASIS
下载PDF
Whole-volume histogram analysis of spectral-computed tomography iodine maps characterizes HER2 expression in gastric cancer
16
作者 Wei-Ling Zhang Jing Sun +8 位作者 Rong-Fang Huang Yi Zeng Shu Chen Xiao-Peng Wang Jin-Hu Chen Yun-Bin Chen Chun-Su Zhu Zai-Sheng Ye You-Ping Xiao 《World Journal of Gastroenterology》 SCIE CAS 2024年第38期4211-4220,共10页
BACKGROUND Although surgery remains the primary treatment for gastric cancer(GC),the identification of effective alternative treatments for individuals for whom surgery is unsuitable holds significance.HER2 overexpres... BACKGROUND Although surgery remains the primary treatment for gastric cancer(GC),the identification of effective alternative treatments for individuals for whom surgery is unsuitable holds significance.HER2 overexpression occurs in approximately 15%-20%of advanced GC cases,directly affecting treatment-related decisions.Spectral-computed tomography(sCT)enables the quantification of material compositions,and sCT iodine concentration parameters have been demonstrated to be useful for the diagnosis of GC and prediction of its invasion depth,angioge-nesis,and response to systemic chemotherapy.No existing report describes the prediction of GC HER2 status through histogram analysis based on sCT iodine maps(IMs).AIM To investigate whether whole-volume histogram analysis of sCT IMs enables the prediction of the GC HER2 status.METHODS This study was performed with data from 101 patients with pathologically confirmed GC who underwent preoperative sCT examinations.Nineteen parameters were extracted via sCT IM histogram analysis:The minimum,maximum,mean,standard deviation,variance,coefficient of variation,skewness,kurtosis,entropy,percentiles(1st,5th,10th,25th,50th,75th,90th,95th,and 99th),and lesion volume.Spearman correlations of the parameters with the HER2 status and clinicopathological parameters were assessed.Receiver operating characteristic curves were used to evaluate the parameters’diagnostic performance.RESULTS Values for the histogram parameters of the maximum,mean,standard deviation,variance,entropy,and percentiles were significantly lower in the HER2+group than in the HER2–group(all P<0.05).The GC differentiation and Lauren classification correlated significantly with the HER2 status of tumor tissue(P=0.001 and 0.023,respectively).The 99th percentile had the largest area under the curve for GC HER2 status identification(0.740),with 76.2%,sensitivity,65.0%specificity,and 67.3%accuracy.All sCT IM histogram parameters correlated positively with the GC HER2 status(r=0.237-0.337,P=0.001-0.017).CONCLUSION Whole-lesion histogram parameters derived from sCT IM analysis,and especially the 99th percentile,can serve as imaging biomarkers of HER2 overexpression in GC. 展开更多
关键词 Gastric cancer Spectral computed tomography Iodine map Histogram analysis
下载PDF
Preoperative prediction of lymphovascular and perineural invasion in gastric cancer using spectral computed tomography imaging and machine learning
17
作者 Hui-Ting Ge Jian-Wu Chen +5 位作者 Li-Li Wang Tian-Xiu Zou Bin Zheng Yuan-Fen Liu Yun-Jing Xue Wei-Wen Lin 《World Journal of Gastroenterology》 SCIE CAS 2024年第6期542-555,共14页
BACKGROUND Lymphovascular invasion(LVI)and perineural invasion(PNI)are important prognostic factors for gastric cancer(GC)that indicate an increased risk of metastasis and poor outcomes.Accurate preoperative predictio... BACKGROUND Lymphovascular invasion(LVI)and perineural invasion(PNI)are important prognostic factors for gastric cancer(GC)that indicate an increased risk of metastasis and poor outcomes.Accurate preoperative prediction of LVI/PNI status could help clinicians identify high-risk patients and guide treatment deci-sions.However,prior models using conventional computed tomography(CT)images to predict LVI or PNI separately have had limited accuracy.Spectral CT provides quantitative enhancement parameters that may better capture tumor invasion.We hypothesized that a predictive model combining clinical and spectral CT parameters would accurately preoperatively predict LVI/PNI status in GC patients.AIM To develop and test a machine learning model that fuses spectral CT parameters and clinical indicators to predict LVI/PNI status accurately.METHODS This study used a retrospective dataset involving 257 GC patients(training cohort,n=172;validation cohort,n=85).First,several clinical indicators,including serum tumor markers,CT-TN stages and CT-detected extramural vein invasion(CT-EMVI),were extracted,as were quantitative spectral CT parameters from the delineated tumor regions.Next,a two-step feature selection approach using correlation-based methods and information gain ranking inside a 10-fold cross-validation loop was utilized to select informative clinical and spectral CT parameters.A logistic regression(LR)-based nomogram model was subsequently constructed to predict LVI/PNI status,and its performance was evaluated using the area under the receiver operating characteristic curve(AUC).RESULTS In both the training and validation cohorts,CT T3-4 stage,CT-N positive status,and CT-EMVI positive status are more prevalent in the LVI/PNI-positive group and these differences are statistically significant(P<0.05).LR analysis of the training group showed preoperative CT-T stage,CT-EMVI,single-energy CT values of 70 keV of venous phase(VP-70 keV),and the ratio of standardized iodine concentration of equilibrium phase(EP-NIC)were independent influencing factors.The AUCs of VP-70 keV and EP-NIC were 0.888 and 0.824,respectively,which were slightly greater than those of CT-T and CT-EMVI(AUC=0.793,0.762).The nomogram combining CT-T stage,CT-EMVI,VP-70 keV and EP-NIC yielded AUCs of 0.918(0.866-0.954)and 0.874(0.784-0.936)in the training and validation cohorts,which are significantly higher than using each of single independent factors(P<0.05).CONCLUSION The study found that using portal venous and EP spectral CT parameters allows effective preoperative detection of LVI/PNI in GC,with accuracy boosted by integrating clinical markers. 展开更多
关键词 Spectral computed tomography Gastric cancer Lymphovascular invasion Perineural invasion
下载PDF
Computed tomography for prediction of esophageal variceal bleeding
18
作者 Mohammed Elhendawy Ferial Elkalla 《World Journal of Gastrointestinal Endoscopy》 2024年第3期175-177,共3页
This letter to the editor relates to the study entitled“The role of computed tomography for the prediction of esophageal variceal bleeding:Current status and future perspectives”.Esophageal variceal bleeding(EVB)is ... This letter to the editor relates to the study entitled“The role of computed tomography for the prediction of esophageal variceal bleeding:Current status and future perspectives”.Esophageal variceal bleeding(EVB)is one of the most common and severe complications related to portal hypertension(PH).Despite marked advances in its management during the last three decades,EVB is still associated with significant morbidity and mortality.The risk of first EVB is related to the severity of both PH and liver disease,and to the size and endoscopic appearance of esophageal varices.Indeed,hepatic venous pressure gradient(HVPG)and esophagogastroduodenoscopy(EGD)are currently recognized as the“gold standard”and the diagnostic reference standard for the prediction of EVB,respectively.However,HVPG is an invasive,expensive,and technically complex procedure,not widely available in clinical practice,whereas EGD is mainly limited by its invasive nature.In this scenario,computed tomography(CT)has been recently proposed as a promising modality for the non-invasive prediction of EVB.While CT serves solely as a diagnostic tool and cannot replace EGD or HVPG for delivering therapeutic and physiological information,it has the potential to enhance the prediction of EVB more effectively when combined with liver disease scores,HVPG,and EGD.However,to date,evidence concerning the role of CT in this setting is still lacking,therefore we aim to summarize and discuss the current evidence concerning the role of CT in predicting the risk of EVB. 展开更多
关键词 Esophageal variceal bleeding Variceal upper gastrointestinal bleeding Portal hypertension Computed tomography Computed tomography angiography
下载PDF
Constructing a nomogram to predict overall survival of colon cancer based on computed tomography characteristics and clinicopathological factors
19
作者 Zhe-Xing Hu Yin Li +6 位作者 Xuan Yang Yu-Xia Li Yao-Yao He Xiao-Hui Niu Ting-Ting Nie Xiao-Fang Guo Zi-Long Yuan 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第10期4104-4114,共11页
BACKGROUND The colon cancer prognosis is influenced by multiple factors,including clinical,pathological,and non-biological factors.However,only a few studies have focused on computed tomography(CT)imaging features.The... BACKGROUND The colon cancer prognosis is influenced by multiple factors,including clinical,pathological,and non-biological factors.However,only a few studies have focused on computed tomography(CT)imaging features.Therefore,this study aims to predict the prognosis of patients with colon cancer by combining CT imaging features with clinical and pathological characteristics,and establishes a nomogram to provide critical guidance for the individualized treatment.AIM To establish and validate a nomogram to predict the overall survival(OS)of patients with colon cancer.METHODS A retrospective analysis was conducted on the survival data of 249 patients with colon cancer confirmed by surgical pathology between January 2017 and December 2021.The patients were randomly divided into training and testing groups at a 1:1 ratio.Univariate and multivariate logistic regression analyses were performed to identify the independent risk factors associated with OS,and a nomogram model was constructed for the training group.Survival curves were calculated using the Kaplan–Meier method.The concordance index(C-index)and calibration curve were used to evaluate the nomogram model in the training and testing groups.RESULTS Multivariate logistic regression analysis revealed that lymph node metastasis on CT,perineural invasion,and tumor classification were independent prognostic factors.A nomogram incorporating these variables was constructed,and the C-index of the training and testing groups was 0.804 and 0.692,respectively.The calibration curves demonstrated good consistency between the actual values and predicted probabilities of OS.CONCLUSION A nomogram combining CT imaging characteristics and clinicopathological factors exhibited good discrimination and reliability.It can aid clinicians in risk stratification and postoperative monitoring and provide important guidance for the individualized treatment of patients with colon cancer. 展开更多
关键词 Colon cancer NOMOGRAM Prognosis Overall survival Computed tomography CLINICOPATHOLOGY
下载PDF
Computed tomography radiogenomics:A potential tool for prediction of molecular subtypes in gastric stromal tumor
20
作者 Xiao-Nan Yin Zi-Hao Wang +6 位作者 Li Zou Cai-Wei Yang Chao-Yong Shen Bai-Ke Liu Yuan Yin Xi-Jiao Liu Bo Zhang 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第4期1296-1308,共13页
BACKGROUND Preoperative knowledge of mutational status of gastrointestinal stromal tumors(GISTs)is essential to guide the individualized precision therapy.AIM To develop a combined model that integrates clinical and c... BACKGROUND Preoperative knowledge of mutational status of gastrointestinal stromal tumors(GISTs)is essential to guide the individualized precision therapy.AIM To develop a combined model that integrates clinical and contrast-enhanced computed tomography(CE-CT)features to predict gastric GISTs with specific genetic mutations,namely KIT exon 11 mutations or KIT exon 11 codons 557-558 deletions.METHODS A total of 231 GIST patients with definitive genetic phenotypes were divided into a training dataset and a validation dataset in a 7:3 ratio.The models were constructed using selected clinical features,conventional CT features,and radiomics features extracted from abdominal CE-CT images.Three models were developed:ModelCT sign,modelCT sign+rad,and model CTsign+rad+clinic.The diagnostic performance of these models was evaluated using receiver operating characteristic(ROC)curve analysis and the Delong test.RESULTS The ROC analyses revealed that in the training cohort,the area under the curve(AUC)values for model_(CT sign),model_(CT sign+rad),and modelCT_(sign+rad+clinic)for predicting KIT exon 11 mutation were 0.743,0.818,and 0.915,respectively.In the validation cohort,the AUC values for the same models were 0.670,0.781,and 0.811,respectively.For predicting KIT exon 11 codons 557-558 deletions,the AUC values in the training cohort were 0.667,0.842,and 0.720 for model_(CT sign),model_(CT sign+rad),and modelCT_(sign+rad+clinic),respectively.In the validation cohort,the AUC values for the same models were 0.610,0.782,and 0.795,respectively.Based on the decision curve analysis,it was determined that the model_(CT sign+rad+clinic)had clinical significance and utility.CONCLUSION Our findings demonstrate that the combined modelCT_(sign+rad+clinic)effectively distinguishes GISTs with KIT exon 11 mutation and KIT exon 11 codons 557-558 deletions.This combined model has the potential to be valuable in assessing the genotype of GISTs. 展开更多
关键词 Gastrointestinal stromal tumor Radiomics Gene mutation Computed tomography MODEL
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部