BACKGROUND The management of hepatoblastoma(HB)becomes challenging when the tumor remains in close proximity to the major liver vasculature(PMV)even after a full course of neoadjuvant chemotherapy(NAC).In such cases,e...BACKGROUND The management of hepatoblastoma(HB)becomes challenging when the tumor remains in close proximity to the major liver vasculature(PMV)even after a full course of neoadjuvant chemotherapy(NAC).In such cases,extreme liver resection can be considered a potential option.AIM To explore whether computer-assisted three-dimensional individualized extreme liver resection is safe and feasible for children with HB who still have PMV after a full course of NAC.METHODS We retrospectively collected data from children with HB who underwent surgical resection at our center from June 2013 to June 2023.We then analyzed the detailed clinical and three-dimensional characteristics of children with HB who still had PMV after a full course of NAC.RESULTS Sixty-seven children diagnosed with HB underwent surgical resection.The age at diagnosis was 21.4±18.8 months,and 40 boys and 27 girls were included.Fifty-nine(88.1%)patients had a single tumor,39(58.2%)of which was located in the right lobe of the liver.A total of 47 patients(70.1%)had PRE-TEXT III or IV.Thirty-nine patients(58.2%)underwent delayed resection.After a full course of NAC,16 patients still had close PMV(within 1 cm in two patients,touching in 11 patients,compressing in four patients,and showing tumor thrombus in three patients).There were 6 patients of tumors in the middle lobe of the liver,and four of those patients exhibited liver anatomy variations.These 16 children underwent extreme liver resection after comprehensive preoperative evaluation.Intraoperative procedures were performed according to the preoperative plan,and the operations were successfully performed.Currently,the 3-year event-free survival of 67 children with HB is 88%.Among the 16 children who underwent extreme liver resection,three experienced recurrence,and one died due to multiple metastases.CONCLUSION Extreme liver resection for HB that is still in close PMV after a full course of NAC is both safe and feasible.This approach not only reduces the necessity for liver transplantation but also results in a favorable prognosis.Individualized three-dimensional surgical planning is beneficial for accurate and complete resection of HB,particularly for assessing vascular involvement,remnant liver volume and anatomical variations.展开更多
The computer-assisted surgery (CAS)has significantly improved the accuracy, reliability and outcomes of traumatic,spinal,nerve surgery and many other operations with a less invasive way.The application of CAS for scap...The computer-assisted surgery (CAS)has significantly improved the accuracy, reliability and outcomes of traumatic,spinal,nerve surgery and many other operations with a less invasive way.The application of CAS for scaphoid fractures remains experimental.The related studies are scanty and most of them are cadaver researches.Some intrinsic defects from the registration procedure,scan and immobilization of limbs may inevitably result in deviations. Some deviations become more obvious with operations of small bones (such as scaphoid)although they are acceptable for spine and other orthopedic surgeries.We reviewed the current literatures on the applications of CAS for scaphoid operation and summarized technical principles,scan and registration methods,immobilization of limbs and their outcomes.On the basis of the data,we analyzed the limitations of this technique and envisioned its future development.展开更多
AIM:To assess the efficacy and safety of non-penetrating deep sclerectomy(NPDS)with uveoscleral implant plus subconjunctival and intrascleral collagen matrix overcoming the superficial scleral flap lips(modified deep ...AIM:To assess the efficacy and safety of non-penetrating deep sclerectomy(NPDS)with uveoscleral implant plus subconjunctival and intrascleral collagen matrix overcoming the superficial scleral flap lips(modified deep sclerectomy technique,DS)and minimal use of mitomycin C in glaucoma surgery.METHODS:A retrospective review of 47 consecutive glaucoma patients who underwent NPDS with DS between January 2017 and May 2018.Best-corrected visual acuity,intraocular pressure(IOP),post-operative need for glaucoma medications,visual field mean deviation(MD),re-interventions,needling revisions and laser goniopuncture were noted.Absolute success was defined as IOP≤18 mm Hg without topical medication.Relative success was defined as the same criteria but with the addition of any antihypertensive medication.IOP over 18 mm Hg on two consecutive followup visits was considered as a failure.RESULTS:Fifty-two eyes of 47 patients were evaluated.Mean preoperative IOP was 25.37±6.47 mm Hg,and decreased to 15.04±4.73 at 12mo and 12.21±4.1 at 24mo(all P<0.0001).Requirement for topical medications dropped from a mean of 3.06±0.25 per patient to 0.51±0.99 and 1.11±1.23 respectively after 12 and 24mo(all P<0.0001).No medications were required in 45.5%of patients after 24mo.Relative and absolute success rate at 24mo were 85.5%±5%and 48.5%±7.4%,respectively.CONCLUSION:DS is a safe and effective nonpenetrating glaucoma surgery variation.It aims to retain the patency of all pathways created for aqueous humor drainage:the intrascleral bleb,the supraciliary space and the open communication between intrascleral and subconjunctival compartments.展开更多
BACKGROUND Most complex renal stones are managed primarily with percutaneous nephrolithotomy(PCNL).However,PCNL is still a great challenge for surgeons because of poor comprehension on complex adjacent structures.Nove...BACKGROUND Most complex renal stones are managed primarily with percutaneous nephrolithotomy(PCNL).However,PCNL is still a great challenge for surgeons because of poor comprehension on complex adjacent structures.Novel techniques are required to assist in planning and navigation.AIM To apply and evaluate the Hisense computer-assisted surgery(CAS)system in PCNL.METHODS A total of 60 patients with complex renal stones were included.Thirty patients in the CAS group had three-dimensional(3 D)virtual models constructed with the CAS system.The model assisted in planning and navigating in the CAS system.Thirty patients in the control group planned and navigated as standard PCNL,without the application of the CAS system.Success rate of one attempt,operation time,initial stone-free rate,decrease in hemoglobin,and complications were collected and analyzed.RESULTS There were no statistically significant differences in the baseline characteristics or planning characteristics.The success rate of one puncturing attempt(90%vs 67%,P=0.028)and the initial stone-free rate(87%vs 63%,P=0.037)were significantly higher in the CAS group.However,there were no statistically significant differences in the operation time(89.20±29.60 min vs 92.33±33.08 min,P=0.859)or in the decrease in hemoglobin(11.07±8.32 g/L vs 9.03±11.72 g/L,P=0.300)between the CAS group and the control group.No statistically significant differences in the incidence of complications(Clavien-Dindo grade≥2)were found.CONCLUSION Compared with standard PCNL,CAS-assisted PCNL had advantages in terms of the puncturing success rate and stone-free rate.The Hisense CAS System was recommended to assist in preoperative planning and intraoperative navigation for an intuitive,precise and convenient PCNL.展开更多
BACKGROUND Ganglioneuroblastoma(GNB)is a peripheral neuroblastoma(NB)with malignant degree between highly malignant NB and benign ganglioma(GN).Pathology is the gold standard of diagnosis.Although GNB is not uncommon ...BACKGROUND Ganglioneuroblastoma(GNB)is a peripheral neuroblastoma(NB)with malignant degree between highly malignant NB and benign ganglioma(GN).Pathology is the gold standard of diagnosis.Although GNB is not uncommon in children,biopsy alone may lead to an inaccurate diagnosis,especially for giant tumors.However,surgical resection may be associated with significant complications.Here,we report a case of computer-assisted surgical resection of a giant GNB in a child and successful rescue of the inferior mesenteric artery.CASE SUMMARY A 4-year-old girl was admitted to our department for a giant retroperitoneal lesion,which was considered to be an NB by her local hospital.The symptoms of the girl disappeared spontaneously without treatment.On physical examination,a mass of about 10 cm×7 cm could be palpated in her abdomen.Ultrasonography and contrast-enhanced computed tomography performed in our hospital also showed an NB,and there was a very thick blood vessel inside the tumor.However,aspiration biopsy revealed GN.Surgical resection is the best treatment option for this giant benign tumor.For precise preoperative evaluation,threedimensional reconstruction was performed.It was clear that the tumor was close to the abdominal aorta.The superior mesenteric vein was pushed forward,and the inferior mesenteric artery passed through the tumor.Because GN generally does not invade blood vessels,we split the tumor with a CUSA knife during the operation and found that there was indeed a straight and intact vascular sheath.Arterial pulsation was observed in the completely exposed inferior mesenteric artery.The pathologists interpreting the tissue finally diagnosed it as a mixed GNB(GNBi),which is more malignant than GN.However,both GN and GNBi usually have a good prognosis.CONCLUSION This was a case of successful surgical resection of a giant GNB,and aspiration biopsy underestimated the pathological staging of the tumor.Preoperative three-dimensional reconstruction assisted with the radical resection of the tumor and rescue of the inferior mesenteric artery.展开更多
There have been nearly 60 years since Thomas Starzl’s first liver transplant.During this period,advancements in medical technology have progressively enabled the adoption of new methods for transplantation.Among thes...There have been nearly 60 years since Thomas Starzl’s first liver transplant.During this period,advancements in medical technology have progressively enabled the adoption of new methods for transplantation.Among these innovations,robotic surgery has emerged in recent decades and is gradually being integrated into transplant medicine.Robotic hepatectomy and liver implantation represent significant advancements in the field of transplant surgery.The precision and minimally invasive nature of robotic surgery offer substantial benefits for both living donors and recipients.In living donors,robotic hepatectomy reduces postoperative pain,minimizes scarring,and accelerates recovery.For liver recipients,robotic liver implantation enhances surgical accuracy,leading to better graft positioning and vascular anastomosis.Robotic systems provide more precise and maneuverable control of instruments,allowing surgeons to perform complex procedures with greater accuracy and reduced risk to patients.This review encompasses publications on minimally invasive donor liver surgery,with a specific focus on robotic liver resection in transplantation,and aims to summarize current knowledge and the development status of robotic surgery in liver transplantation,focusing on liver resection in donors and graft implantation in recipients.展开更多
BACKGROUND Coronary stent implantation is usually used to treat unstable angina to alleviate stenosis or occlusion,promoting blood flow restoration and alleviating symptoms such as myocardial ischemia.And postoperativ...BACKGROUND Coronary stent implantation is usually used to treat unstable angina to alleviate stenosis or occlusion,promoting blood flow restoration and alleviating symptoms such as myocardial ischemia.And postoperative cardiac rehabilitation is essential for enhancing recovery and prognosis.Nevertheless,conventional rehabilitation lacks specificity,particularly for elderly patients with multiple comorbidities and poor compliance,rendering it less effective.AIM To investigate the effects of systematic cardiac rehabilitation training in elderly patients with unstable angina following coronary stenting intervention.METHODS A retrospective enrollment was conducted comprising fifty-four elderly patients with unstable angina pectoris who underwent systematic cardiac rehabilitation training after receiving coronary intervention as the rehabilitation group,while fifty-three elderly patients who received basic nursing and rehabilitation guidance measures after coronary intervention were assigned to the control group.Differences in Seattle Angina Questionnaire scores,survival quality(SF-36)scores,cardiopulmonary exercise function assessment index,echocardiographic cardiac function index,and adverse cardiovascular events were compared between the two groups.RESULTS After intervention,the rehabilitation group observed greater VO2 Max,maximum metabolic equivalent,eft ventricular ejection fraction,left ventricular end-diastolic diameter and smaller left ventricular end-systolic diameter.And the rehabilitation group observed greater scores of physical activity limitation,stable angina pectoris,treatment satisfaction,and SF-36 score.The incidence of adverse cardiovascular events in the two groups,showed no significant difference.CONCLUSION Systematic cardiac rehabilitation following coronary stenting in elderly patients with unstable angina pectoris can enhance cardiac function recovery,consequently enhancing both quality of life and cardiopulmonary exercise tolerance.展开更多
Craniomaxillofacial surgery is difficult due to the complexity of the regional anatomy. Computer-assisted surgery is a promising tool aiming to improve the safety and precision of such surgery. A computer-assisted sur...Craniomaxillofacial surgery is difficult due to the complexity of the regional anatomy. Computer-assisted surgery is a promising tool aiming to improve the safety and precision of such surgery. A computer-assisted surgical navigation approach for reconstruction of mandibular defects using a patient-specific titanium mesh tray and particulate cancellous bone and marrow (PCBM) harvested from bilateral anterior ilia is proposed. This case report involves a large multicystic ameloblastoma affecting the right mandible of a 31-year-old male patient. Following detailed clinical examination, radiological interpretation, and histopathological diagnosis, computer-assisted surgical simulation with a virtual 3-dimensional (3-D) model was designed using surgical planning software based on the pre-operative computed tomography data. Long-span segmental resection of the mandible was planned, and the defect was analyzed for reconstruction using a patient-specific reconstruction titanium mesh tray mediated with computer-aided design and manufacturing (CAD/CAM) techniques. During the actual surgery, the ultrasonic bone cutting instrument in the surgeon’s hand was connected to the navigation system to touch an anatomical position on the patient. Therefore, osteotomies were performed finely and smoothly according to the navigation images of the cutting bone line by sequentially moving the instrument. Finally, a CAD/CAM-mediated titanium mesh tray condensed by PCBM was adapted to the remaining mandibular fragments. Six months postoperatively, the patient had a good mandibular configuration and facial contour. Integration of different technologies, such as software planning and 3-D surgical simulation, combined with intraoperative navigation and CAD/CAM techniques, provides safe and precise mandibular reconstruction surgery.展开更多
BACKGROUND The conventional implant approach involves flap elevation,which may result in increased soft tissue and bone loss and postoperative morbidity.The flapless surgical technique,aided by three-dimensional medic...BACKGROUND The conventional implant approach involves flap elevation,which may result in increased soft tissue and bone loss and postoperative morbidity.The flapless surgical technique,aided by three-dimensional medical imaging equipment,is regarded as a possible alternative to the conventional approach to alleviate the above issues.Several studies have been performed regarding the role of flapless implant surgery.However,the results are inconsistent and there is no robust synthesis of long-term evidence to better inform surgeons regarding which type of surgical technique is more beneficial to the long-term prognosis of patients in need of implant insertion.AIM To compare the long-term clinical performance after flapless implant surgery to that after the conventional approach with flap elevation.METHODS PubMed,EMBASE,Cochrane Central Register of Controlled Trials,and grey literature databases were searched from inception to 23 September 2019.Randomised controlled trials (RCTs) and cohort studies comparing the long-term clinical performance after flapless implant surgery to that after the conventional approach over a follow-up of three years or more were induded.Meta-analyses were conducted to estimate the odds ratios (ORs) or mean differences (MDs) and their 95 To confidence intervals (CIs) between the long-term implant survival rate,marginal bone loss,and complication rate of the flapless and conventional groups.Subgroup analyses were carried out to account for the possible effects of the guided or free-hand method during flapless surgery.RESULTS Ten articles,including four RCTs and six cohort studies,satisfied the eligibility criteria and nine of them were inclded in the meta-analysis.There was no significant difference between the long-term implant survival rate [OR=1.30,95%CI (0.37,4.54),P=0.68],marginal bone loss [MD=0.01,95%CI (-0.42,0.44),P=0.97],and complication rate [OR=1.44,95%CI (0.77,2.68),P=0.25] after flapless implant surgery and the conventional approach.Moreover,subgroup analyses revealed that there was no statistically significant difference between the implant survival rate [guided:OR=1.52,95%CI (0.19,12.35),P=0.70];free-hand:n=1,could not be estimated),marginal bone loss [guided:MD=0.22,95%CI (-0.14,0.59),P=0.23;free-hand:MD=-0.27,95%CI (-1.10,0.57),P=0.53],or complication rate [guided:OR=1.16,95%CI (0.52,2.63),P=0.71;free-hand:OR=1.75,95%CI(0.66,4.63),P=0.26] in the flapless and conventional groups either with use of the surgical guide or by the free-hand method.CONCLUSION The flapless surgery and conventional approach had comparable clinical performance over three years or more.The guided or free-hand technique does not significantly affect the long-term outcomes of flapless surgery.展开更多
At present,dental implant surgery mainly relies on the clinical experience of the doctor and the assistance of preoperative medical imaging.However,there are some problems in dental implant surgery,such as narrow spac...At present,dental implant surgery mainly relies on the clinical experience of the doctor and the assistance of preoperative medical imaging.However,there are some problems in dental implant surgery,such as narrow space,sight obstruction,inaccurate positioning,and high requirements of doctors’proficiency.Therefore,a dental implant robot system(DIRS)guided by optical navigation is developed in this study,with an x-shaped tool and an irregular pentagonal tracer are designed for spatial registration and needle tip positioning strategy respectively.The coordinate system of each unit in DIRS is unified through system calibration,spatial registration,and needle tip positioning strategy.Then the surgical path is planned on the computed tomography(CT)images in the navigation software before operation.The automatic positioning method and the auxiliary positioning method can be used in the operation to achieve accurate positioning and assist doctors to complete the operation.The errors of spatial registration,needle tip positioning strategy,and the overall accuracy of the system were evaluated respectively,and the results showed that they all met the needs of clinical surgery.This study preliminarily verified the feasibility of the precise positioning method for dental surgery robots and provided certain ideas for subsequent related research.展开更多
Objective To report a case of the implantation of thyroid hyperplastic or neoplastic tissue after endoscopic thyroidectomy and discuss this complication in aspects of prevalence, pathogenesis, protection, and therapie...Objective To report a case of the implantation of thyroid hyperplastic or neoplastic tissue after endoscopic thyroidectomy and discuss this complication in aspects of prevalence, pathogenesis, protection, and therapies. Methods A systematic search of literature from the PubMed database was conducted for identifying eligible studies on implantation of thyroid hyperplastic or neoplastic cells after endoscopic thyroid surgery. Results Overall, 5 reported cases on patients suffering from endoscopic thyroid surgery with implantation of thyroid hyperplastic or neoplastic cells were included in the systematic review. Conclusions Unskilled surgeons, rough intraoperative surgical treatment, scarification or rupture of tumor, contamination of instruments, chimney effect, aerosolization of tumor cells may be associated with the implantation after endoscopic thyroidectomy. To minimize the risk of such complication, we should be more meticulous and strict the endoscopic surgery indications.展开更多
Introduction: To report by using topical anesthesia for standing phacoemulsification and intraocular lens implantation for two patients who need cataract extraction but unable to lie flat with marked cervical kyphosis...Introduction: To report by using topical anesthesia for standing phacoemulsification and intraocular lens implantation for two patients who need cataract extraction but unable to lie flat with marked cervical kyphosis due to long-standing ankylosing spondylitis and chronic uveitis. Methods: Two patients are unable to lie flat respectively during phacoemulsification underwent this technique in Jingdong and Tonghai county Hospital of Yunnan province in China. Each patient was positioned erect or semirecumbent in a standard reclining cataract surgical chair. The ceiling-mounted microscope was rotated 60 degrees from the vertical to point toward the patient. Results: The intraoperative and postoperative periods were uneventful in two patients, with good visual outcomes after surgery. Conclusion: This technique is valuable for situations where the patient requires upright positioning because of the inability to recline flat, and should be considered for cases where standard surgical positioning is not possible.展开更多
AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent biman...AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent bimanual microincision cataract surgery(B-MICS).METHODS:Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study:40 eyes were implanted with an Incise?MJ14 IOL through a 1.4 mm CCI(group A)without enlargement of the main CCI,while 40 eyes were implanted with an Akreos?MI60 IOL with enlargement of the main CCI to 1.8 mm(group B).Best corrected visual acuity(BCVA),astigmatism and endothelial cell loss were evaluated before and after surgery at 7,30d and 6mo.Anterior segment-optical coherence tomography(AS-OCT)of CCI was performed at 1,3,7,30d,6 and 18mo.PCO incidence was evaluated at 18mo using EPCO 2000 Software.RESULTS:Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups;no statistically significant difference in surgically induced astigmatism(SIA)was noticed in the two groups.At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet’s membrane at 1 and 7d after surgery;no statistically significant alterations were found at 1,6 and 18mo.PCO score at 18mo was 0.03±0.07for group A and 0.08±0.18 for group B(P=0.11)with no sign of central optic plate invasion in both groups.CONCLUSION:The implant of the new Incise?MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery.PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up.展开更多
【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shun...【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shunt surgery increases the incidence and progression of cataracts[1].An Ahmed valve,the most commonly inserted GDD,is composed of a silicone tube connected to a flat plate sewn to the sclera,and aqueous humor flows from the展开更多
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W...AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group.展开更多
AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted...AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery.展开更多
Introduction: Cochlear implant (CI) surgery allows hearing reestablishment among individuals with severe to profound hearing loss. However, only few patients will need a surgical reassessment. Objectives: To verify th...Introduction: Cochlear implant (CI) surgery allows hearing reestablishment among individuals with severe to profound hearing loss. However, only few patients will need a surgical reassessment. Objectives: To verify the incidence of surgical reassessment among adult patients;to verify the reasons that led the second surgery to be performed;to verify the efficacy—and audiological outcomes—of revisional surgery. Method: A longitudinal retrospective cohort study was carried out with the review of medical records, of adult patients, with bilateral severe to profound sensorineural hearing loss who underwent to revisional surgery, from 2004 to 2016 at a CI Center, in Brazil. Results: One hundred fifty-eight CI surgeries were performed among 137 adult patients. Fourteen revisional surgeries were performed among 10 patients: five surgeries were due by displacement of the internal unit;one because of having excessive subcutaneous tissue;one due to non-progression of the electrodes during the initial surgery, one late tympanic membrane perforation, one late facial palsy and, one due to a suture dehiscence in the surgical incision with exposure of the internal unit. Conclusions: The incidence of surgical reassessment among adult CI patients was 8.9%. All implanted patients that underwent a new surgical approach maintained an improved auditory threshold after revisional CI surgery.展开更多
Background: Surgical site infection (SSI) is a dreaded nightmare for the Orthopaedic surgeon. Preoperative skin cleaning with antiseptics has been shown to reduce the microbial burden of the skin and results in reduce...Background: Surgical site infection (SSI) is a dreaded nightmare for the Orthopaedic surgeon. Preoperative skin cleaning with antiseptics has been shown to reduce the microbial burden of the skin and results in reduced incidence of SSI. However, the ideal skin cleaning agent remains to be established. Aim: To compare the efficacy of Povidone-Iodine/Povidone-Iodine (PI-PI) combination with that of Chlorhexidine-Gluconate/Alcohol (CG-A) combination in re-ducing SSI in Orthopaedic surgeries. Methods: This was a prospective, randomized, double-blinded, controlled study. Subjects that met the selection criteria and gave consent were randomized into PI-PI group (test group) and the CG-A group (control group). Both the patients and the assessors for SSI were blinded to the group a participant belongs. Blocking was done on the type of surgery to cancel the confounding effect of surgery type on SSI. Standard perioperative protocols were applied to both groups. Assessment for features of SSI was done on the 3rd day, 7th day, 14th day, 6th week and 12th-week postoperative period. The diagnosis of SSI was made based on the Centers for Disease and Control (CDC) guidelines. Results: We recruited 124 patients for this study, 62 males and 54 females. The mean age of the subjects was 37.5 years (SD = 14.7 years). Sixty-two subjects were randomized into each group. There was no significant difference in the distribution of the genders in the study arms. Other possible confounders such as duration of hospital stay, use of drains, the surgeon involved and age were evenly distributed in the two groups. Eight patients did not complete the study. The overall incidence of SSI in the study was 2.6%. Subjects in the control group had an SSI of 3.4% while those in the PI-PI group had a rate of 1.8%;however, this was not significant, p = 0.579. Conclusion: Both CG-A and PI-PI combinations are equally efficacious as preoperative skin antiseptic in Orthopaedic implant surgeries.展开更多
AIM: To introduce the navigation system of software and instruments designed specifically for revision total knee arthroplasty(TKA).METHODS: We present an imageless navigation system for revision TKA,with optical poin...AIM: To introduce the navigation system of software and instruments designed specifically for revision total knee arthroplasty(TKA).METHODS: We present an imageless navigation system for revision TKA,with optical point and tracker identification to assess kinematic and anatomical landmarks.The system automatically positions the cutting guides with a motorized cutting unit.The cutting unit is placed on the distal femur with a femoral clamp and acts as a rigid body and the base for all femoral cuts.The surgical technique for using the navigation system for revision TKA is based on the technique used in primary TKA.However,there are some important differences.The most notable are:(1) differences in estimation of the position of the primary implant relative to the bone and the mechanical axes;(2) the specific possibilities the revision navigation software offers in terms of optimal joint level positioning; and(3) the suggested "best fit" position,in which the clock position,stem position and offset,femoral component size,and mediolateral position of the femoral component are taken into account to find the optimal femoral component position.We assessed the surgical technique,and accompanying software procedural steps,of the system,identifying any advantages or disadvantages that they present.RESULTS: The system aims to visualize critical steps of the procedure and is intended as a tool to support the surgeon in surgical decision-making.Combining a computer-assisted cutting device with navigation makes it possible to carry out precise cuts without pinning.Furthermore,the femoral clamp provides a stable fixation mechanism for the motorized cutting unit.A stable clamp is paramount in the presence of periarticular bony defects.The system allows the position of the primary implant relative to the bone and mechanical axes to be estimated,at which point any malalignments can be corrected.It also offers an optimal joint level position for implantation,and suggests a "best fit" position,in which the clock position,stem position and offset,femoral component size,and mediolateral position of the femoral component are considered.The surgeon can therefore make decisions intraoperatively to maximise alignment and,hence,outcomes.Based on the intraoperative findings of joint stability,the surgeon can modify the preoperative plan and switch from a constrained condylar system to a hinged version,or vice versa.CONCLUSION: The system is flexible and easy to learn and allows improvements in workflow during TKA.展开更多
It has been reported that up to 12% of patients underwent non-cardiac surgery or invasive procedures within the first year after the coronary stent implantation. Premature dis- continuation of antiplatelet therapy is ...It has been reported that up to 12% of patients underwent non-cardiac surgery or invasive procedures within the first year after the coronary stent implantation. Premature dis- continuation of antiplatelet therapy is associated with a sig- nificant increase in mortality and major adverse cardiac events, in particular, stent thrombosis. Thus, postpone- ment of elective surgery is advocated during the first year after the coronary stent implantation.展开更多
基金Supported by National Natural Science Foundation of China,No.82293665Anhui Provincial Department of Education University Research Project,No.2023AH051763.
文摘BACKGROUND The management of hepatoblastoma(HB)becomes challenging when the tumor remains in close proximity to the major liver vasculature(PMV)even after a full course of neoadjuvant chemotherapy(NAC).In such cases,extreme liver resection can be considered a potential option.AIM To explore whether computer-assisted three-dimensional individualized extreme liver resection is safe and feasible for children with HB who still have PMV after a full course of NAC.METHODS We retrospectively collected data from children with HB who underwent surgical resection at our center from June 2013 to June 2023.We then analyzed the detailed clinical and three-dimensional characteristics of children with HB who still had PMV after a full course of NAC.RESULTS Sixty-seven children diagnosed with HB underwent surgical resection.The age at diagnosis was 21.4±18.8 months,and 40 boys and 27 girls were included.Fifty-nine(88.1%)patients had a single tumor,39(58.2%)of which was located in the right lobe of the liver.A total of 47 patients(70.1%)had PRE-TEXT III or IV.Thirty-nine patients(58.2%)underwent delayed resection.After a full course of NAC,16 patients still had close PMV(within 1 cm in two patients,touching in 11 patients,compressing in four patients,and showing tumor thrombus in three patients).There were 6 patients of tumors in the middle lobe of the liver,and four of those patients exhibited liver anatomy variations.These 16 children underwent extreme liver resection after comprehensive preoperative evaluation.Intraoperative procedures were performed according to the preoperative plan,and the operations were successfully performed.Currently,the 3-year event-free survival of 67 children with HB is 88%.Among the 16 children who underwent extreme liver resection,three experienced recurrence,and one died due to multiple metastases.CONCLUSION Extreme liver resection for HB that is still in close PMV after a full course of NAC is both safe and feasible.This approach not only reduces the necessity for liver transplantation but also results in a favorable prognosis.Individualized three-dimensional surgical planning is beneficial for accurate and complete resection of HB,particularly for assessing vascular involvement,remnant liver volume and anatomical variations.
基金the National Natural Science Foundation of China(No.51675036)the Innovation and Development Project of Intelligent Manufacturing Technique from Beijing Municipal Science and Technology Commission(No.Z161100001516012).
文摘The computer-assisted surgery (CAS)has significantly improved the accuracy, reliability and outcomes of traumatic,spinal,nerve surgery and many other operations with a less invasive way.The application of CAS for scaphoid fractures remains experimental.The related studies are scanty and most of them are cadaver researches.Some intrinsic defects from the registration procedure,scan and immobilization of limbs may inevitably result in deviations. Some deviations become more obvious with operations of small bones (such as scaphoid)although they are acceptable for spine and other orthopedic surgeries.We reviewed the current literatures on the applications of CAS for scaphoid operation and summarized technical principles,scan and registration methods,immobilization of limbs and their outcomes.On the basis of the data,we analyzed the limitations of this technique and envisioned its future development.
文摘AIM:To assess the efficacy and safety of non-penetrating deep sclerectomy(NPDS)with uveoscleral implant plus subconjunctival and intrascleral collagen matrix overcoming the superficial scleral flap lips(modified deep sclerectomy technique,DS)and minimal use of mitomycin C in glaucoma surgery.METHODS:A retrospective review of 47 consecutive glaucoma patients who underwent NPDS with DS between January 2017 and May 2018.Best-corrected visual acuity,intraocular pressure(IOP),post-operative need for glaucoma medications,visual field mean deviation(MD),re-interventions,needling revisions and laser goniopuncture were noted.Absolute success was defined as IOP≤18 mm Hg without topical medication.Relative success was defined as the same criteria but with the addition of any antihypertensive medication.IOP over 18 mm Hg on two consecutive followup visits was considered as a failure.RESULTS:Fifty-two eyes of 47 patients were evaluated.Mean preoperative IOP was 25.37±6.47 mm Hg,and decreased to 15.04±4.73 at 12mo and 12.21±4.1 at 24mo(all P<0.0001).Requirement for topical medications dropped from a mean of 3.06±0.25 per patient to 0.51±0.99 and 1.11±1.23 respectively after 12 and 24mo(all P<0.0001).No medications were required in 45.5%of patients after 24mo.Relative and absolute success rate at 24mo were 85.5%±5%and 48.5%±7.4%,respectively.CONCLUSION:DS is a safe and effective nonpenetrating glaucoma surgery variation.It aims to retain the patency of all pathways created for aqueous humor drainage:the intrascleral bleb,the supraciliary space and the open communication between intrascleral and subconjunctival compartments.
基金Supported by the Science and Technology Program in Chinese Medicine of Shandong Province,No.2020M074。
文摘BACKGROUND Most complex renal stones are managed primarily with percutaneous nephrolithotomy(PCNL).However,PCNL is still a great challenge for surgeons because of poor comprehension on complex adjacent structures.Novel techniques are required to assist in planning and navigation.AIM To apply and evaluate the Hisense computer-assisted surgery(CAS)system in PCNL.METHODS A total of 60 patients with complex renal stones were included.Thirty patients in the CAS group had three-dimensional(3 D)virtual models constructed with the CAS system.The model assisted in planning and navigating in the CAS system.Thirty patients in the control group planned and navigated as standard PCNL,without the application of the CAS system.Success rate of one attempt,operation time,initial stone-free rate,decrease in hemoglobin,and complications were collected and analyzed.RESULTS There were no statistically significant differences in the baseline characteristics or planning characteristics.The success rate of one puncturing attempt(90%vs 67%,P=0.028)and the initial stone-free rate(87%vs 63%,P=0.037)were significantly higher in the CAS group.However,there were no statistically significant differences in the operation time(89.20±29.60 min vs 92.33±33.08 min,P=0.859)or in the decrease in hemoglobin(11.07±8.32 g/L vs 9.03±11.72 g/L,P=0.300)between the CAS group and the control group.No statistically significant differences in the incidence of complications(Clavien-Dindo grade≥2)were found.CONCLUSION Compared with standard PCNL,CAS-assisted PCNL had advantages in terms of the puncturing success rate and stone-free rate.The Hisense CAS System was recommended to assist in preoperative planning and intraoperative navigation for an intuitive,precise and convenient PCNL.
基金Supported by Qingdao Civic Science and Technology Program,No.17-3-3-8-nsh.
文摘BACKGROUND Ganglioneuroblastoma(GNB)is a peripheral neuroblastoma(NB)with malignant degree between highly malignant NB and benign ganglioma(GN).Pathology is the gold standard of diagnosis.Although GNB is not uncommon in children,biopsy alone may lead to an inaccurate diagnosis,especially for giant tumors.However,surgical resection may be associated with significant complications.Here,we report a case of computer-assisted surgical resection of a giant GNB in a child and successful rescue of the inferior mesenteric artery.CASE SUMMARY A 4-year-old girl was admitted to our department for a giant retroperitoneal lesion,which was considered to be an NB by her local hospital.The symptoms of the girl disappeared spontaneously without treatment.On physical examination,a mass of about 10 cm×7 cm could be palpated in her abdomen.Ultrasonography and contrast-enhanced computed tomography performed in our hospital also showed an NB,and there was a very thick blood vessel inside the tumor.However,aspiration biopsy revealed GN.Surgical resection is the best treatment option for this giant benign tumor.For precise preoperative evaluation,threedimensional reconstruction was performed.It was clear that the tumor was close to the abdominal aorta.The superior mesenteric vein was pushed forward,and the inferior mesenteric artery passed through the tumor.Because GN generally does not invade blood vessels,we split the tumor with a CUSA knife during the operation and found that there was indeed a straight and intact vascular sheath.Arterial pulsation was observed in the completely exposed inferior mesenteric artery.The pathologists interpreting the tissue finally diagnosed it as a mixed GNB(GNBi),which is more malignant than GN.However,both GN and GNBi usually have a good prognosis.CONCLUSION This was a case of successful surgical resection of a giant GNB,and aspiration biopsy underestimated the pathological staging of the tumor.Preoperative three-dimensional reconstruction assisted with the radical resection of the tumor and rescue of the inferior mesenteric artery.
文摘There have been nearly 60 years since Thomas Starzl’s first liver transplant.During this period,advancements in medical technology have progressively enabled the adoption of new methods for transplantation.Among these innovations,robotic surgery has emerged in recent decades and is gradually being integrated into transplant medicine.Robotic hepatectomy and liver implantation represent significant advancements in the field of transplant surgery.The precision and minimally invasive nature of robotic surgery offer substantial benefits for both living donors and recipients.In living donors,robotic hepatectomy reduces postoperative pain,minimizes scarring,and accelerates recovery.For liver recipients,robotic liver implantation enhances surgical accuracy,leading to better graft positioning and vascular anastomosis.Robotic systems provide more precise and maneuverable control of instruments,allowing surgeons to perform complex procedures with greater accuracy and reduced risk to patients.This review encompasses publications on minimally invasive donor liver surgery,with a specific focus on robotic liver resection in transplantation,and aims to summarize current knowledge and the development status of robotic surgery in liver transplantation,focusing on liver resection in donors and graft implantation in recipients.
文摘BACKGROUND Coronary stent implantation is usually used to treat unstable angina to alleviate stenosis or occlusion,promoting blood flow restoration and alleviating symptoms such as myocardial ischemia.And postoperative cardiac rehabilitation is essential for enhancing recovery and prognosis.Nevertheless,conventional rehabilitation lacks specificity,particularly for elderly patients with multiple comorbidities and poor compliance,rendering it less effective.AIM To investigate the effects of systematic cardiac rehabilitation training in elderly patients with unstable angina following coronary stenting intervention.METHODS A retrospective enrollment was conducted comprising fifty-four elderly patients with unstable angina pectoris who underwent systematic cardiac rehabilitation training after receiving coronary intervention as the rehabilitation group,while fifty-three elderly patients who received basic nursing and rehabilitation guidance measures after coronary intervention were assigned to the control group.Differences in Seattle Angina Questionnaire scores,survival quality(SF-36)scores,cardiopulmonary exercise function assessment index,echocardiographic cardiac function index,and adverse cardiovascular events were compared between the two groups.RESULTS After intervention,the rehabilitation group observed greater VO2 Max,maximum metabolic equivalent,eft ventricular ejection fraction,left ventricular end-diastolic diameter and smaller left ventricular end-systolic diameter.And the rehabilitation group observed greater scores of physical activity limitation,stable angina pectoris,treatment satisfaction,and SF-36 score.The incidence of adverse cardiovascular events in the two groups,showed no significant difference.CONCLUSION Systematic cardiac rehabilitation following coronary stenting in elderly patients with unstable angina pectoris can enhance cardiac function recovery,consequently enhancing both quality of life and cardiopulmonary exercise tolerance.
文摘Craniomaxillofacial surgery is difficult due to the complexity of the regional anatomy. Computer-assisted surgery is a promising tool aiming to improve the safety and precision of such surgery. A computer-assisted surgical navigation approach for reconstruction of mandibular defects using a patient-specific titanium mesh tray and particulate cancellous bone and marrow (PCBM) harvested from bilateral anterior ilia is proposed. This case report involves a large multicystic ameloblastoma affecting the right mandible of a 31-year-old male patient. Following detailed clinical examination, radiological interpretation, and histopathological diagnosis, computer-assisted surgical simulation with a virtual 3-dimensional (3-D) model was designed using surgical planning software based on the pre-operative computed tomography data. Long-span segmental resection of the mandible was planned, and the defect was analyzed for reconstruction using a patient-specific reconstruction titanium mesh tray mediated with computer-aided design and manufacturing (CAD/CAM) techniques. During the actual surgery, the ultrasonic bone cutting instrument in the surgeon’s hand was connected to the navigation system to touch an anatomical position on the patient. Therefore, osteotomies were performed finely and smoothly according to the navigation images of the cutting bone line by sequentially moving the instrument. Finally, a CAD/CAM-mediated titanium mesh tray condensed by PCBM was adapted to the remaining mandibular fragments. Six months postoperatively, the patient had a good mandibular configuration and facial contour. Integration of different technologies, such as software planning and 3-D surgical simulation, combined with intraoperative navigation and CAD/CAM techniques, provides safe and precise mandibular reconstruction surgery.
基金the Graduate Student's Research and Innovation Fund of Sichuan University,No.2018YJSY108the China Postdoctoral Science Foundation Funded Project,No.2018M640931+1 种基金the Science and Technology Key Research and Development Program of Sichuan Province,No.2019YFS0142the National Natural Science Foundation of China,No.81901060.
文摘BACKGROUND The conventional implant approach involves flap elevation,which may result in increased soft tissue and bone loss and postoperative morbidity.The flapless surgical technique,aided by three-dimensional medical imaging equipment,is regarded as a possible alternative to the conventional approach to alleviate the above issues.Several studies have been performed regarding the role of flapless implant surgery.However,the results are inconsistent and there is no robust synthesis of long-term evidence to better inform surgeons regarding which type of surgical technique is more beneficial to the long-term prognosis of patients in need of implant insertion.AIM To compare the long-term clinical performance after flapless implant surgery to that after the conventional approach with flap elevation.METHODS PubMed,EMBASE,Cochrane Central Register of Controlled Trials,and grey literature databases were searched from inception to 23 September 2019.Randomised controlled trials (RCTs) and cohort studies comparing the long-term clinical performance after flapless implant surgery to that after the conventional approach over a follow-up of three years or more were induded.Meta-analyses were conducted to estimate the odds ratios (ORs) or mean differences (MDs) and their 95 To confidence intervals (CIs) between the long-term implant survival rate,marginal bone loss,and complication rate of the flapless and conventional groups.Subgroup analyses were carried out to account for the possible effects of the guided or free-hand method during flapless surgery.RESULTS Ten articles,including four RCTs and six cohort studies,satisfied the eligibility criteria and nine of them were inclded in the meta-analysis.There was no significant difference between the long-term implant survival rate [OR=1.30,95%CI (0.37,4.54),P=0.68],marginal bone loss [MD=0.01,95%CI (-0.42,0.44),P=0.97],and complication rate [OR=1.44,95%CI (0.77,2.68),P=0.25] after flapless implant surgery and the conventional approach.Moreover,subgroup analyses revealed that there was no statistically significant difference between the implant survival rate [guided:OR=1.52,95%CI (0.19,12.35),P=0.70];free-hand:n=1,could not be estimated),marginal bone loss [guided:MD=0.22,95%CI (-0.14,0.59),P=0.23;free-hand:MD=-0.27,95%CI (-1.10,0.57),P=0.53],or complication rate [guided:OR=1.16,95%CI (0.52,2.63),P=0.71;free-hand:OR=1.75,95%CI(0.66,4.63),P=0.26] in the flapless and conventional groups either with use of the surgical guide or by the free-hand method.CONCLUSION The flapless surgery and conventional approach had comparable clinical performance over three years or more.The guided or free-hand technique does not significantly affect the long-term outcomes of flapless surgery.
基金Natural Science Foundation of Guangdong Province(Grant No.2021A1515011208)National Natural Scientific Foundation of China(Grant No.81671788)+1 种基金National Science Foundation for Young Scientists of China(Grant No.81701662)The Joint Found of National Science Foundation of China and GuangDong Provincial Government(Grant No.U1301258).
文摘At present,dental implant surgery mainly relies on the clinical experience of the doctor and the assistance of preoperative medical imaging.However,there are some problems in dental implant surgery,such as narrow space,sight obstruction,inaccurate positioning,and high requirements of doctors’proficiency.Therefore,a dental implant robot system(DIRS)guided by optical navigation is developed in this study,with an x-shaped tool and an irregular pentagonal tracer are designed for spatial registration and needle tip positioning strategy respectively.The coordinate system of each unit in DIRS is unified through system calibration,spatial registration,and needle tip positioning strategy.Then the surgical path is planned on the computed tomography(CT)images in the navigation software before operation.The automatic positioning method and the auxiliary positioning method can be used in the operation to achieve accurate positioning and assist doctors to complete the operation.The errors of spatial registration,needle tip positioning strategy,and the overall accuracy of the system were evaluated respectively,and the results showed that they all met the needs of clinical surgery.This study preliminarily verified the feasibility of the precise positioning method for dental surgery robots and provided certain ideas for subsequent related research.
文摘Objective To report a case of the implantation of thyroid hyperplastic or neoplastic tissue after endoscopic thyroidectomy and discuss this complication in aspects of prevalence, pathogenesis, protection, and therapies. Methods A systematic search of literature from the PubMed database was conducted for identifying eligible studies on implantation of thyroid hyperplastic or neoplastic cells after endoscopic thyroid surgery. Results Overall, 5 reported cases on patients suffering from endoscopic thyroid surgery with implantation of thyroid hyperplastic or neoplastic cells were included in the systematic review. Conclusions Unskilled surgeons, rough intraoperative surgical treatment, scarification or rupture of tumor, contamination of instruments, chimney effect, aerosolization of tumor cells may be associated with the implantation after endoscopic thyroidectomy. To minimize the risk of such complication, we should be more meticulous and strict the endoscopic surgery indications.
文摘Introduction: To report by using topical anesthesia for standing phacoemulsification and intraocular lens implantation for two patients who need cataract extraction but unable to lie flat with marked cervical kyphosis due to long-standing ankylosing spondylitis and chronic uveitis. Methods: Two patients are unable to lie flat respectively during phacoemulsification underwent this technique in Jingdong and Tonghai county Hospital of Yunnan province in China. Each patient was positioned erect or semirecumbent in a standard reclining cataract surgical chair. The ceiling-mounted microscope was rotated 60 degrees from the vertical to point toward the patient. Results: The intraoperative and postoperative periods were uneventful in two patients, with good visual outcomes after surgery. Conclusion: This technique is valuable for situations where the patient requires upright positioning because of the inability to recline flat, and should be considered for cases where standard surgical positioning is not possible.
文摘AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent bimanual microincision cataract surgery(B-MICS).METHODS:Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study:40 eyes were implanted with an Incise?MJ14 IOL through a 1.4 mm CCI(group A)without enlargement of the main CCI,while 40 eyes were implanted with an Akreos?MI60 IOL with enlargement of the main CCI to 1.8 mm(group B).Best corrected visual acuity(BCVA),astigmatism and endothelial cell loss were evaluated before and after surgery at 7,30d and 6mo.Anterior segment-optical coherence tomography(AS-OCT)of CCI was performed at 1,3,7,30d,6 and 18mo.PCO incidence was evaluated at 18mo using EPCO 2000 Software.RESULTS:Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups;no statistically significant difference in surgically induced astigmatism(SIA)was noticed in the two groups.At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet’s membrane at 1 and 7d after surgery;no statistically significant alterations were found at 1,6 and 18mo.PCO score at 18mo was 0.03±0.07for group A and 0.08±0.18 for group B(P=0.11)with no sign of central optic plate invasion in both groups.CONCLUSION:The implant of the new Incise?MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery.PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up.
文摘【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shunt surgery increases the incidence and progression of cataracts[1].An Ahmed valve,the most commonly inserted GDD,is composed of a silicone tube connected to a flat plate sewn to the sclera,and aqueous humor flows from the
基金Supported by National Natural Science Foundation of China(No.82070937,No.81870640)National Science Foundation for Young Scientists of China(No.82101097)。
文摘AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group.
基金Supported by the Science and Technology Innovation Program of Hunan Province,China(No.2020SK50103)Hunan Clinical Medical Technology Innovation Guiding Project in 2020。
文摘AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery.
文摘Introduction: Cochlear implant (CI) surgery allows hearing reestablishment among individuals with severe to profound hearing loss. However, only few patients will need a surgical reassessment. Objectives: To verify the incidence of surgical reassessment among adult patients;to verify the reasons that led the second surgery to be performed;to verify the efficacy—and audiological outcomes—of revisional surgery. Method: A longitudinal retrospective cohort study was carried out with the review of medical records, of adult patients, with bilateral severe to profound sensorineural hearing loss who underwent to revisional surgery, from 2004 to 2016 at a CI Center, in Brazil. Results: One hundred fifty-eight CI surgeries were performed among 137 adult patients. Fourteen revisional surgeries were performed among 10 patients: five surgeries were due by displacement of the internal unit;one because of having excessive subcutaneous tissue;one due to non-progression of the electrodes during the initial surgery, one late tympanic membrane perforation, one late facial palsy and, one due to a suture dehiscence in the surgical incision with exposure of the internal unit. Conclusions: The incidence of surgical reassessment among adult CI patients was 8.9%. All implanted patients that underwent a new surgical approach maintained an improved auditory threshold after revisional CI surgery.
文摘Background: Surgical site infection (SSI) is a dreaded nightmare for the Orthopaedic surgeon. Preoperative skin cleaning with antiseptics has been shown to reduce the microbial burden of the skin and results in reduced incidence of SSI. However, the ideal skin cleaning agent remains to be established. Aim: To compare the efficacy of Povidone-Iodine/Povidone-Iodine (PI-PI) combination with that of Chlorhexidine-Gluconate/Alcohol (CG-A) combination in re-ducing SSI in Orthopaedic surgeries. Methods: This was a prospective, randomized, double-blinded, controlled study. Subjects that met the selection criteria and gave consent were randomized into PI-PI group (test group) and the CG-A group (control group). Both the patients and the assessors for SSI were blinded to the group a participant belongs. Blocking was done on the type of surgery to cancel the confounding effect of surgery type on SSI. Standard perioperative protocols were applied to both groups. Assessment for features of SSI was done on the 3rd day, 7th day, 14th day, 6th week and 12th-week postoperative period. The diagnosis of SSI was made based on the Centers for Disease and Control (CDC) guidelines. Results: We recruited 124 patients for this study, 62 males and 54 females. The mean age of the subjects was 37.5 years (SD = 14.7 years). Sixty-two subjects were randomized into each group. There was no significant difference in the distribution of the genders in the study arms. Other possible confounders such as duration of hospital stay, use of drains, the surgeon involved and age were evenly distributed in the two groups. Eight patients did not complete the study. The overall incidence of SSI in the study was 2.6%. Subjects in the control group had an SSI of 3.4% while those in the PI-PI group had a rate of 1.8%;however, this was not significant, p = 0.579. Conclusion: Both CG-A and PI-PI combinations are equally efficacious as preoperative skin antiseptic in Orthopaedic implant surgeries.
基金Supported by Smith and Nephew Gmb H,Marl,Germany
文摘AIM: To introduce the navigation system of software and instruments designed specifically for revision total knee arthroplasty(TKA).METHODS: We present an imageless navigation system for revision TKA,with optical point and tracker identification to assess kinematic and anatomical landmarks.The system automatically positions the cutting guides with a motorized cutting unit.The cutting unit is placed on the distal femur with a femoral clamp and acts as a rigid body and the base for all femoral cuts.The surgical technique for using the navigation system for revision TKA is based on the technique used in primary TKA.However,there are some important differences.The most notable are:(1) differences in estimation of the position of the primary implant relative to the bone and the mechanical axes;(2) the specific possibilities the revision navigation software offers in terms of optimal joint level positioning; and(3) the suggested "best fit" position,in which the clock position,stem position and offset,femoral component size,and mediolateral position of the femoral component are taken into account to find the optimal femoral component position.We assessed the surgical technique,and accompanying software procedural steps,of the system,identifying any advantages or disadvantages that they present.RESULTS: The system aims to visualize critical steps of the procedure and is intended as a tool to support the surgeon in surgical decision-making.Combining a computer-assisted cutting device with navigation makes it possible to carry out precise cuts without pinning.Furthermore,the femoral clamp provides a stable fixation mechanism for the motorized cutting unit.A stable clamp is paramount in the presence of periarticular bony defects.The system allows the position of the primary implant relative to the bone and mechanical axes to be estimated,at which point any malalignments can be corrected.It also offers an optimal joint level position for implantation,and suggests a "best fit" position,in which the clock position,stem position and offset,femoral component size,and mediolateral position of the femoral component are considered.The surgeon can therefore make decisions intraoperatively to maximise alignment and,hence,outcomes.Based on the intraoperative findings of joint stability,the surgeon can modify the preoperative plan and switch from a constrained condylar system to a hinged version,or vice versa.CONCLUSION: The system is flexible and easy to learn and allows improvements in workflow during TKA.
文摘It has been reported that up to 12% of patients underwent non-cardiac surgery or invasive procedures within the first year after the coronary stent implantation. Premature dis- continuation of antiplatelet therapy is associated with a sig- nificant increase in mortality and major adverse cardiac events, in particular, stent thrombosis. Thus, postpone- ment of elective surgery is advocated during the first year after the coronary stent implantation.