A novel method for detecting early damage at the steel-concrete interface due to external loading based on AC impedance spectroscopy technology was proposed.Firstly,alkali pretreatment was introduced to ensure the acc...A novel method for detecting early damage at the steel-concrete interface due to external loading based on AC impedance spectroscopy technology was proposed.Firstly,alkali pretreatment was introduced to ensure the accuracy and repeatability of the AC impedance test.Secondly,the AC impedance spectroscopy between the steel bar and concrete surface of different bonding positions was tested,and then the physical quantities reflecting the bonding damage condition were obtained by equivalent circuit fitting.Theoretical debonding position calculation and AC conductive structure analysis indicate that the change of interface resistance and interface capacitance can seize the development of bonding damage during the loading process.As the interface damage develops,obvious changes in interface resistance and interface capacitance are observed,and they cannot be recovered after unloading.展开更多
In order to validate the accuracy of nonlinear fire simulation programs,comparison analysis is carried out between simulation and experiment induced from small-scale specimens,and then fire resistance of large-scale p...In order to validate the accuracy of nonlinear fire simulation programs,comparison analysis is carried out between simulation and experiment induced from small-scale specimens,and then fire resistance of large-scale prestressed concrete slabs is further investigated through parameter expansion.The influences on fire resistance ratings controlled by deflection are explored and discussed,including effective span,concrete cover thickness,load level,prestress degree,effective prestress,composite reinforcement index and other factors.The calculated results indicate that fire resistance ratings of large-scale bonded prestressed concrete simply supported slabs are bigger than those of small-scale ones.Finally,the calculation formulas of fire resistance ratings controlled by deflection are established,which rationally consider the influence of effective span,concrete cover thickness,load level,composite reinforcement index and so on key factors.展开更多
Since last two decades,the Portland Pozzolane Cement(PPC)is extensively used in structural concrete.But,till to date,a few literature is available on bond strength of concrete using PPC mixes.There are many literature...Since last two decades,the Portland Pozzolane Cement(PPC)is extensively used in structural concrete.But,till to date,a few literature is available on bond strength of concrete using PPC mixes.There are many literatures available on bond strength of concrete mixes using Ordinary Portland Cement(OPC).Hence,a comparative study was conducted on bond strength between OPC and PPC mixes.In the present investigation,total 24 samples consisting of M20,M35 and M50 grades of concrete and 16 and 25 mm diameter of TMT bar were tested for 7 and 28 days.The pullout bond test was conducted on each specimen as per IS:2770-1967/1997[1]and the results were observed at 0.25 mm slip at loaded end called as critical bond stress and at maximum bond load called as maximum bond stress.It was observed that the critical bond strength of PPC mixes is 10%higher than OPC mixes.Whereas,marginal improvement was noticed in maximum bond strength of PPC mixes.Hence,based on these findings,it could be concluded that development length for PPC mixes could be reduced by 10%as compared with same grade of OPC mixes.展开更多
基金Funded by the Opening Funds of State Key Laboratory of Building Safety and Built Environment and National Engineering Research Center of Building Technology (No.BSBE2019-07)the Young Talent Support Program of Hebei Institutions of Higher Learning (No.BJ2017019)the National Natural Science Foundation of China (No.51808357)。
文摘A novel method for detecting early damage at the steel-concrete interface due to external loading based on AC impedance spectroscopy technology was proposed.Firstly,alkali pretreatment was introduced to ensure the accuracy and repeatability of the AC impedance test.Secondly,the AC impedance spectroscopy between the steel bar and concrete surface of different bonding positions was tested,and then the physical quantities reflecting the bonding damage condition were obtained by equivalent circuit fitting.Theoretical debonding position calculation and AC conductive structure analysis indicate that the change of interface resistance and interface capacitance can seize the development of bonding damage during the loading process.As the interface damage develops,obvious changes in interface resistance and interface capacitance are observed,and they cannot be recovered after unloading.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50678050)
文摘In order to validate the accuracy of nonlinear fire simulation programs,comparison analysis is carried out between simulation and experiment induced from small-scale specimens,and then fire resistance of large-scale prestressed concrete slabs is further investigated through parameter expansion.The influences on fire resistance ratings controlled by deflection are explored and discussed,including effective span,concrete cover thickness,load level,prestress degree,effective prestress,composite reinforcement index and other factors.The calculated results indicate that fire resistance ratings of large-scale bonded prestressed concrete simply supported slabs are bigger than those of small-scale ones.Finally,the calculation formulas of fire resistance ratings controlled by deflection are established,which rationally consider the influence of effective span,concrete cover thickness,load level,composite reinforcement index and so on key factors.
文摘Since last two decades,the Portland Pozzolane Cement(PPC)is extensively used in structural concrete.But,till to date,a few literature is available on bond strength of concrete using PPC mixes.There are many literatures available on bond strength of concrete mixes using Ordinary Portland Cement(OPC).Hence,a comparative study was conducted on bond strength between OPC and PPC mixes.In the present investigation,total 24 samples consisting of M20,M35 and M50 grades of concrete and 16 and 25 mm diameter of TMT bar were tested for 7 and 28 days.The pullout bond test was conducted on each specimen as per IS:2770-1967/1997[1]and the results were observed at 0.25 mm slip at loaded end called as critical bond stress and at maximum bond load called as maximum bond stress.It was observed that the critical bond strength of PPC mixes is 10%higher than OPC mixes.Whereas,marginal improvement was noticed in maximum bond strength of PPC mixes.Hence,based on these findings,it could be concluded that development length for PPC mixes could be reduced by 10%as compared with same grade of OPC mixes.