期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Evaluation of internal void related defects in reinforced concrete slab using electromagnetic wave properties
1
作者 Minju Kang Jinyoung Hong +2 位作者 Taemin Lee Doyun Kim Hajin Choi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第3期525-535,共11页
This study aims to develop a damage-detection algorithm based on the electromagnetic wave properties inside a reinforced concrete structure.The proposed method involves employing two algorithms based on data measured ... This study aims to develop a damage-detection algorithm based on the electromagnetic wave properties inside a reinforced concrete structure.The proposed method involves employing two algorithms based on data measured using ground-penetrating radar—a common electromagnetic wave method in civil engineering.The possible defect area was identified based on the energy dissipated by the damage in the frequency-wavenumber domain,with the damage localized using the calculated relative permittivity of the measurements.The proposed method was verified through a finite difference time-domain-based numerical analysis and a testing slab with artificial damage.As a result of verification,the proposed method quickly identified the presence of damage inside the concrete,especially for honeycomb-like defects located at the top of the rebar.This study has practical significance in scanning structures over a large area more quickly than other non-destructive testing methods,such as ultrasonic methods. 展开更多
关键词 GPR concrete defect electromagnetic wave relative permittivity non-destructive testing(NDT)
下载PDF
Experimental and numerical study on structural performance of reinforced concrete box sewer with localized extreme defect 被引量:1
2
作者 Yuequan Bao Dongyang Feng +2 位作者 Nan Ma Hehua Zhu Timon Rabczuk 《Underground Space》 SCIE EI 2018年第2期166-179,共14页
An experimental and numerical investigation into the structural performance of reinforced concrete box sewers with typical corrosion-related extreme defects localized at the ceiling was conducted.Firstly,during the la... An experimental and numerical investigation into the structural performance of reinforced concrete box sewers with typical corrosion-related extreme defects localized at the ceiling was conducted.Firstly,during the large-scale laboratory test,some key struc-tural responses were captured and evaluated,including the crack width development process(via digital image correlation measurement),ceiling deflection,and material strains of both complete and typical defective boxes.The failure modes and load-carrying mechanism throughout the specimen loading phases were analyzed.Furthermore,the specimen failure process was simulated using a damage-basedfinite element method,and a related parameter sensitivity analysis was performed.The results indicate that the defective ceiling cracked at mid-span under a low load value,but the bending capacity loss can be substituted by two shoulders and carry three tofive times more load before completely collapsing.The simulation matched the lab test qualitatively,and with the suggested set strategy of material parameters,the load-deflection feature curve could provide a practical prediction of the ultimate bearing capacity of the defec-tive sewers,with a 10–15%error on the safe side. 展开更多
关键词 Defective reinforced concrete box sewer Corrosion Structural performance Large-scale model test Digital image correlation measurement Failure simulation