In this article the high strength micro-expansive concrete that has been applied on big-diameter and long-span steel arch bridge is researched. The applications show that the concrete has some merits, such as good flu...In this article the high strength micro-expansive concrete that has been applied on big-diameter and long-span steel arch bridge is researched. The applications show that the concrete has some merits, such as good fluidity, low bleeding ratio and no segregation, low slump loss, high early strength and high later strength, micro-expansion etc.展开更多
A convenient approach is proposed for analyzing the ultimate load carrying capacity of concrete filled steel tubular (CFST) arch bridge with stiffening girders. A fiber model beam element is specially used to simulate...A convenient approach is proposed for analyzing the ultimate load carrying capacity of concrete filled steel tubular (CFST) arch bridge with stiffening girders. A fiber model beam element is specially used to simulate the stiffening girder and CFST arch rib. The geometric nonlinearity, material nonlinearity, influence of the construction process and the contribution of prestressing reinforcement are all taken into consideration. The accuracy of this method is validated by comparing its results with experimental results. Finally, the ultimate strength of an abnormal CFST arch bridge with stiffening girders is investigated and the effect of construction method is discussed. It is concluded that the construction process has little effect on the ultimate strength of the bridge.展开更多
Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and ...Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test process can be divided into three stages depending on the lateral brace configurations, i.e., fully (five) braced, two braces removed, and all braces removed. A total of 46 tests, starting from the elastic state to failure condition, have been conducted. The natural vibration frequencies, responses of acceleration, displacement and strain were measured. From the test results, it is demonstrated that the CFT arch structures are capable of resisting severe ground motions and that CFT arches offer a credible alternative to reinforced concrete arches, especially in regions of high seismic intensity.展开更多
An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of ...An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of steel tube and the steel fiber volume fraction on the ultimate strength and the ductility. The experimental results indicate that the addition of steel fibers in concrete can significantly improve the ductility and the energy dissipation capacity of the concrete-filled steel tube columns and delay the local buckling of the steel tube, but has no obvious effect on the failure mode. It has also been found that the addition of steel fibers is a more effective method than using thicker steel tube in enhancing the ductility, and more advantageous in the case of higher strength concrete. An analytical model to estimate the load capacity is proposed for steel tube columns filled with both plain concrete and steel fiber reinforced concrete. The predicted results are in good agreement with the experimental ones obtained in this work and literatures.展开更多
Using age adjusted effective modulus(AAEM)method,creep of concrete filled steel tube(CFST)member was formulated considering of creep coefficient and aging coefficient.Ten CFST specimens were tested including eight for...Using age adjusted effective modulus(AAEM)method,creep of concrete filled steel tube(CFST)member was formulated considering of creep coefficient and aging coefficient.Ten CFST specimens were tested including eight for creep and two for shrinkage.The experimental result was compared with the computed result using AAEM in which the creep coefficient was taken from calibration of ACI model based on experimental result on sealed concrete,and aging coefficient was supplied from relaxation test on sealed concrete specimen.Furthermore,the creep of CFST member was analyzed using author's own subroutine to input concrete properties through user programmable feature(UPF)in ANSYS software.Comparison was made on authors' own experimental database,some existing experimental results,and results from AAEM and numerical analysis.Finally,the conditions of applicability of AAEM method are put forward,and numerical approach to compute creep of CFST specimen is delineated.展开更多
The creep-induced deformation of the arch rib of concrete-filled steel tubular(CFST) arches under a sustained load can increase the bending moment, which may lead to earlier stability failure called creep buckling. To...The creep-induced deformation of the arch rib of concrete-filled steel tubular(CFST) arches under a sustained load can increase the bending moment, which may lead to earlier stability failure called creep buckling. To investigate the influences of concrete creep on the buckling strength of arches, a theoretical analysis for the creep buckling of CFST circular arches under distributed radial load is performed. The simplified Arutyunyan-Maslov(AM)creep law is used to model the creep behavior of concrete core, and the creep integral operator is introduced. The analytical solutions of the time-dependent buckling strength under the sustained load are achieved and compared with the existing formula based on the age-adjusted effective modulus method(AEMM). Then the solutions are used to determine the influences of the steel ratio and the first loading age on the creep buckling of CFST arches. The results show that the analytical solutions are of good accuracy and applicability. For CFST arches, the steel ratio and the first loading age have significant influences on creep buckling. An approximate log-linear relationship between the decreased degrees of the creep buckling strength and the first loading age is found. For the commonly used parameters, the maximum loss of the buckling strength induced by concrete creep is close to 40%.展开更多
The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined wit...The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined with fiber-reinforced polymer (FRP) wraps. Totally 11 short column specimens were tested to failure under axial compression. The influences of the type and quantity of FRP, the thickness of steel tube and the concrete strength were studied. It was found that the bearing capacity of short FRP-CFST column was much higher than that of comparable CFST column. Furthermore, the formulas for calculating the bearing capacity of the FRP-CFST columns are proposed. The analytical calculated results agree well with the experimental results.展开更多
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat...A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures.展开更多
The simplified algorithm for out-of-plane ultimate loadcarrying capacity of concrete-filled steel tubular( CFST) solid-rib arches under uniform vertical load was studied. The experimentally validated finite element mo...The simplified algorithm for out-of-plane ultimate loadcarrying capacity of concrete-filled steel tubular( CFST) solid-rib arches under uniform vertical load was studied. The experimentally validated finite element model was developed. The out-of-plane equivalent length coefficients of solid-rib arches were obtained using out-of-plane elastic eigenvalue buckling analysis. Then the out-ofplane elastic stability coefficient was plotted against the normalized slenderness ratio,and the out-of-plane eigenvalue buckling load or elastic buckling capability of arches was calculated. Lastly effects of different parameters on the out-of-plane ultimate load-carrying capacity of CFST solid-rib arches were determined using geometric and material nonlinear finite element analysis, and a simplified algorithm was established by fitting the out-of-plane elastic-plastic stability coefficient and normalized slenderness ratio using PerryRobertson formula. Ratio of the elastic stability coefficient to the elastic-plastic counterpart was plotted against the out-of-plane normalized slenderness ratio,from which the out-of-plane elasticplastic ultimate load-carrying capacity was determined according to the corresponding elastic buckling load. Results show that the proposed simplified algorithm can accurately predict the out-of-plane eigenvalue buckling load and the elastic-plastic ultimate loadcarrying capacity of the CFST solid-rib arches.展开更多
A total of fifteen self-stressing and selfcompacting concrete(SSC)filled steel tube columns and three common self-compacting concrete filled steel tube(CFST)columns are tested under eccentric compression load to analy...A total of fifteen self-stressing and selfcompacting concrete(SSC)filled steel tube columns and three common self-compacting concrete filled steel tube(CFST)columns are tested under eccentric compression load to analyze the the effect of initial self-stress on the compression behavior of CFSTs.The results show that the elastic working range of the columns is lengthened because of initial self-stress and it slightly decreases with the increase of load eccentricity ratio and slenderness ratio.Because of the initial self-stress,the concrete core is always under compression in three directions,so the compactness is enhanced and the ultimate bearing capacity obviously increases;but the initial self-stress hardly affects the failure mode of the columns.展开更多
基金Funded by the State" the Nineth Five-Plan" of Communica-tion Ministry
文摘In this article the high strength micro-expansive concrete that has been applied on big-diameter and long-span steel arch bridge is researched. The applications show that the concrete has some merits, such as good fluidity, low bleeding ratio and no segregation, low slump loss, high early strength and high later strength, micro-expansion etc.
文摘A convenient approach is proposed for analyzing the ultimate load carrying capacity of concrete filled steel tubular (CFST) arch bridge with stiffening girders. A fiber model beam element is specially used to simulate the stiffening girder and CFST arch rib. The geometric nonlinearity, material nonlinearity, influence of the construction process and the contribution of prestressing reinforcement are all taken into consideration. The accuracy of this method is validated by comparing its results with experimental results. Finally, the ultimate strength of an abnormal CFST arch bridge with stiffening girders is investigated and the effect of construction method is discussed. It is concluded that the construction process has little effect on the ultimate strength of the bridge.
基金This study was supported by the National Natural Science Foundation of China under Grant No.50078016Open Funding of State Key Laboratory for Disaster Reduction in Civil Engineering,China.
文摘Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test process can be divided into three stages depending on the lateral brace configurations, i.e., fully (five) braced, two braces removed, and all braces removed. A total of 46 tests, starting from the elastic state to failure condition, have been conducted. The natural vibration frequencies, responses of acceleration, displacement and strain were measured. From the test results, it is demonstrated that the CFT arch structures are capable of resisting severe ground motions and that CFT arches offer a credible alternative to reinforced concrete arches, especially in regions of high seismic intensity.
基金Project(51078294)supported by the National Natural Science Foundation of ChinaProject(201101411100025)supported by the Doctoral Fund of Ministry of Education of China
文摘An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of steel tube and the steel fiber volume fraction on the ultimate strength and the ductility. The experimental results indicate that the addition of steel fibers in concrete can significantly improve the ductility and the energy dissipation capacity of the concrete-filled steel tube columns and delay the local buckling of the steel tube, but has no obvious effect on the failure mode. It has also been found that the addition of steel fibers is a more effective method than using thicker steel tube in enhancing the ductility, and more advantageous in the case of higher strength concrete. An analytical model to estimate the load capacity is proposed for steel tube columns filled with both plain concrete and steel fiber reinforced concrete. The predicted results are in good agreement with the experimental ones obtained in this work and literatures.
文摘Using age adjusted effective modulus(AAEM)method,creep of concrete filled steel tube(CFST)member was formulated considering of creep coefficient and aging coefficient.Ten CFST specimens were tested including eight for creep and two for shrinkage.The experimental result was compared with the computed result using AAEM in which the creep coefficient was taken from calibration of ACI model based on experimental result on sealed concrete,and aging coefficient was supplied from relaxation test on sealed concrete specimen.Furthermore,the creep of CFST member was analyzed using author's own subroutine to input concrete properties through user programmable feature(UPF)in ANSYS software.Comparison was made on authors' own experimental database,some existing experimental results,and results from AAEM and numerical analysis.Finally,the conditions of applicability of AAEM method are put forward,and numerical approach to compute creep of CFST specimen is delineated.
基金Supported by the National Natural Science Foundation of China(No.51378162,No.51178150)the National Key Technology Research and Development Program of the Ministry of Science and Technology of China(No2013BAJ08B01)
文摘The creep-induced deformation of the arch rib of concrete-filled steel tubular(CFST) arches under a sustained load can increase the bending moment, which may lead to earlier stability failure called creep buckling. To investigate the influences of concrete creep on the buckling strength of arches, a theoretical analysis for the creep buckling of CFST circular arches under distributed radial load is performed. The simplified Arutyunyan-Maslov(AM)creep law is used to model the creep behavior of concrete core, and the creep integral operator is introduced. The analytical solutions of the time-dependent buckling strength under the sustained load are achieved and compared with the existing formula based on the age-adjusted effective modulus method(AEMM). Then the solutions are used to determine the influences of the steel ratio and the first loading age on the creep buckling of CFST arches. The results show that the analytical solutions are of good accuracy and applicability. For CFST arches, the steel ratio and the first loading age have significant influences on creep buckling. An approximate log-linear relationship between the decreased degrees of the creep buckling strength and the first loading age is found. For the commonly used parameters, the maximum loss of the buckling strength induced by concrete creep is close to 40%.
基金Funded by the National Natural Science Foundation of China (No.50678136)the Hubei Provincial Foundation for Young Outstanding Talents(No. 2004ABB014)
文摘The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined with fiber-reinforced polymer (FRP) wraps. Totally 11 short column specimens were tested to failure under axial compression. The influences of the type and quantity of FRP, the thickness of steel tube and the concrete strength were studied. It was found that the bearing capacity of short FRP-CFST column was much higher than that of comparable CFST column. Furthermore, the formulas for calculating the bearing capacity of the FRP-CFST columns are proposed. The analytical calculated results agree well with the experimental results.
基金National Natural Science Foundation of China under Grant No.51148009National Natural Science Foundation of China under Grant No.50978005Project High-level Personnel in Beijing under Grant No.PHR20100502
文摘A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures.
基金National Natural Science Foundation of China(No.51178119)
文摘The simplified algorithm for out-of-plane ultimate loadcarrying capacity of concrete-filled steel tubular( CFST) solid-rib arches under uniform vertical load was studied. The experimentally validated finite element model was developed. The out-of-plane equivalent length coefficients of solid-rib arches were obtained using out-of-plane elastic eigenvalue buckling analysis. Then the out-ofplane elastic stability coefficient was plotted against the normalized slenderness ratio,and the out-of-plane eigenvalue buckling load or elastic buckling capability of arches was calculated. Lastly effects of different parameters on the out-of-plane ultimate load-carrying capacity of CFST solid-rib arches were determined using geometric and material nonlinear finite element analysis, and a simplified algorithm was established by fitting the out-of-plane elastic-plastic stability coefficient and normalized slenderness ratio using PerryRobertson formula. Ratio of the elastic stability coefficient to the elastic-plastic counterpart was plotted against the out-of-plane normalized slenderness ratio,from which the out-of-plane elasticplastic ultimate load-carrying capacity was determined according to the corresponding elastic buckling load. Results show that the proposed simplified algorithm can accurately predict the out-of-plane eigenvalue buckling load and the elastic-plastic ultimate loadcarrying capacity of the CFST solid-rib arches.
文摘A total of fifteen self-stressing and selfcompacting concrete(SSC)filled steel tube columns and three common self-compacting concrete filled steel tube(CFST)columns are tested under eccentric compression load to analyze the the effect of initial self-stress on the compression behavior of CFSTs.The results show that the elastic working range of the columns is lengthened because of initial self-stress and it slightly decreases with the increase of load eccentricity ratio and slenderness ratio.Because of the initial self-stress,the concrete core is always under compression in three directions,so the compactness is enhanced and the ultimate bearing capacity obviously increases;but the initial self-stress hardly affects the failure mode of the columns.