Damage assessment for seismic response of recycled concrete filled steel tube columns 被引量:4
1
作者 Huang Yijie Xiao Jianzhuang Shen Luming 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第3期607-616,共10页
A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the eff... A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the effect of repeated cyclic loading into account. Available test results were collected and utilized to calibrate the parameters of the proposed model. A seismic test for six RCFST columns was also performed to validate the proposed damage assessment model. The main test parameters were the recycled coarse aggregate (RCA) replacement percentage and the bond-slip property. The test results indicated that the seismic performance of the RCFST member depends on the RCA contents and their damage index increases as the RCA replacement percentage increases. It is also indicated that the damage degree of RCFST changes with the variation of the RCA replacement percentage. Finally, comparisons between the RCA contents, lateral deformation ratio and damage degree were implemented. It is suggested that an improvement procedure should be implemented in order to compensate for the performance difference between the RCFST and normal concrete filled steel tubes (CFST). 展开更多
关键词 recycled aggregate concrete (RAC) recycled concrete filled steel tube (RCFST) column seismicperformance damage assessment model (DAM)
下载PDF
Seismic performance of recycled concrete-filled square steel tube columns 被引量:9
2
作者 Chen Zongping Jing Chenggui +1 位作者 Xu Jinjun Zhang Xianggang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期119-130,共12页
An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic later... An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance. 展开更多
关键词 recycled concrete-filled square steel tube (RCFST) column replacement percentage cyclic loading seismicperformance
下载PDF
Bearing capacity of composite columns reinforced by concrete filled steel tube 被引量:1
3
作者 韦建刚 ZHU Pu CHEN Bao-chun 《Journal of Chongqing University》 CAS 2013年第1期27-34,共8页
In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance ... In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance under axial or eccentric compression. The failure mode is characterized by the crush of the outer concrete. The bearing capacity increases at first and then decreases with further increase of the position coefficient. It can be concluded that position coefficient is an important structural parameter that has considerable influences on the ultimate bearing capacity of the composite columns. The outer concrete, steel tubes and longitudinal reinforcement are found to work in a cooperative manner under axial or eccentric compression when the position coefficient is about 0.5. An improved bearing capacity algorithm that takes the position coefficient into account has been proposed based on the experimental and simulation results and current technical specification in China. It has been proven to be precise and safe. 展开更多
关键词 concrete filled steel tube composite column position factor TEST FORMULA
下载PDF
Three-dimensional nonlinear analysis of creep in concrete filled steel tube columns 被引量:1
4
作者 程晓东 李广宇 叶贵如 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第8期826-835,共10页
This paper proposes a based on 3D-VLE (three-dimensional nonlinear viscoelastic theory) three-parameters viscoelastic model for studying the time-dependent behaviour of concrete filled steel tube (CFT) columns. Th... This paper proposes a based on 3D-VLE (three-dimensional nonlinear viscoelastic theory) three-parameters viscoelastic model for studying the time-dependent behaviour of concrete filled steel tube (CFT) columns. The method of 3D-VLE was developed to analyze the effects of concrete creep behavior on CFT structures. After the evaluation of the parameters in the proposed creep model, experimental measurements of two prestressed reinforced concrete beams were used to investigate the creep phenomenon of three CFT columns under long-term axial and eccentric load was investigated. The experimentally obtained time-dependent creep behaviour accorded well with the cu~'es obtained from the proposed method. Many factors (such as ratio of long-term load to strength, slenderness ratio, steel ratio, and eccentricity ratio) were considered to obtain the regularity of influence of concrete creep on CFT structures. The analytical results can be consulted in the engineering practice and design. 展开更多
关键词 Three-dimensional virtual laminated element (3D-VLE) Creep analysis Three-dimensional viscoelastic theory Three-parameters viscoelastic model concrete filled steel tube columns
下载PDF
Performance Investigation of Square Concrete-filled Steel Tube Columns
5
作者 陈兵 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第4期730-736,共7页
The behaviour of square concrete-filled steel tube columns under concentrical loading was studied. More than one hundred specimens were tested to investigate the effects of thickness of steel tube on the load carrying... The behaviour of square concrete-filled steel tube columns under concentrical loading was studied. More than one hundred specimens were tested to investigate the effects of thickness of steel tube on the load carrying capacity of the concrete-filled tubular columns (CFTs). The effect of the grade of concrete and content of expansive agent were also investigated. The effect of these parameters on the confinement of the concrete core was studied as well. From the experimental study it was found that for both CFTs with different strength grade concrete core, the ultimate load carrying capacity increases with the increase in percentage of expansive agent up to 20% but it again decreases at 25% of expansive agent content. It was also shown that the failure mode of CFTs depends on the strength grade of concrete core. 展开更多
关键词 concrete filled steel tubes concrete columnS ultimate capacity expansive agent
下载PDF
Seismic behavior of concrete filled steel tubular arch structures 被引量:4
6
作者 熊峰 Sashi K Kunnath 刘浩吾 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2005年第1期107-115,共9页
Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and ... Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test process can be divided into three stages depending on the lateral brace configurations, i.e., fully (five) braced, two braces removed, and all braces removed. A total of 46 tests, starting from the elastic state to failure condition, have been conducted. The natural vibration frequencies, responses of acceleration, displacement and strain were measured. From the test results, it is demonstrated that the CFT arch structures are capable of resisting severe ground motions and that CFT arches offer a credible alternative to reinforced concrete arches, especially in regions of high seismic intensity. 展开更多
关键词 concrete filled steel tube arch structures shaking table test seismic behavior lateral braces
下载PDF
Axial Bearing Capacity of Short FRP Confined Concrete-filled Steel Tubular Columns 被引量:7
7
作者 刘兰 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第3期454-458,共5页
The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined wit... The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined with fiber-reinforced polymer (FRP) wraps. Totally 11 short column specimens were tested to failure under axial compression. The influences of the type and quantity of FRP, the thickness of steel tube and the concrete strength were studied. It was found that the bearing capacity of short FRP-CFST column was much higher than that of comparable CFST column. Furthermore, the formulas for calculating the bearing capacity of the FRP-CFST columns are proposed. The analytical calculated results agree well with the experimental results. 展开更多
关键词 columnS concrete-filled steel tubes (CFST) fiber reinforced polymer (FRP) CONFINEMENT bearing capacity.
下载PDF
Prediction of Axial Capacity of Concrete-Filled Square Steel Tubes Using Neural Networks
8
作者 朱美春 王清湘 冯秀峰 《Journal of Southwest Jiaotong University(English Edition)》 2005年第2期151-155,共5页
The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concret... The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns. 展开更多
关键词 concrete-filled square steel tubes Neural networks Axial capacity Short columns
下载PDF
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
9
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
下载PDF
设有叠合柱的局部错层RC框架结构地震易损性分析 被引量:1
10
作者 张淑云 刘建波 +2 位作者 代慧娟 王乐 高欣悦 《中国科技论文》 CAS 2024年第3期275-283,共9页
为研究某一设有叠合柱的局部错层钢筋混凝土(reinforced concrete,RC)框架结构在近断层和远场地震作用下的破坏概率,自定义钢管混凝土叠合柱塑性铰参数,并与试验对比验证塑性铰参数的有效性。采用SAP2000建立非线性分析模型,选取近断层... 为研究某一设有叠合柱的局部错层钢筋混凝土(reinforced concrete,RC)框架结构在近断层和远场地震作用下的破坏概率,自定义钢管混凝土叠合柱塑性铰参数,并与试验对比验证塑性铰参数的有效性。采用SAP2000建立非线性分析模型,选取近断层和远场地震波共22条,分别以地震峰值加速度(peak ground acceleration,PGA)和最大层间位移角作为地震动强度指标和结构性能指标,基于增量动力分析(incremental dynamic analysis,IDA)结果和点估计函数对错层框架结构进行易损性分析。结果表明:对于远场地震动,结构满足“三水准”抗震设防要求,在罕遇地震下超越防止倒塌极限状态的概率仅为0.24%;结构在近断层多遇地震下仍能满足“小震不坏”的设计要求,设防地震下结构超越修复后使用极限状态的概率为53.63%,发生中等破坏的概率较大,罕遇地震下结构达到倒塌极限状态的概率为5.37%,较远场地震作用破坏更为严重。研究结果可为错层框架结构的设计和地震风险评估提供参考。 展开更多
关键词 近断层地震 错层框架结构 钢管混凝土叠合柱 增量动力分析 点估计
下载PDF
钢管混凝土键连接框架梁和剪力墙的受剪性能 被引量:1
11
作者 李明 刘栩邑 +2 位作者 吴潜 吴欣禹 吴永新 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2024年第1期38-46,共9页
目的 研究钢管混凝土键连接框架梁和剪力墙的受剪性能,为工程应用提供设计依据。方法 应用有限元分析软件ABAQUS对比钢管混凝土键连接与现浇连接梁墙的结构受剪性能,分析前者受剪机理及不同因素对受剪性能的影响。结果 钢管混凝土键连... 目的 研究钢管混凝土键连接框架梁和剪力墙的受剪性能,为工程应用提供设计依据。方法 应用有限元分析软件ABAQUS对比钢管混凝土键连接与现浇连接梁墙的结构受剪性能,分析前者受剪机理及不同因素对受剪性能的影响。结果 钢管混凝土键连接梁墙的结构承载力和延性系数较现浇结构分别提高约10%和34%;钢材强度从Q235到Q390,初始刚度增加8.44%;截面高度从100 mm到120 mm,延性系数提高17.73%;截面厚度每增加2 mm,承载力提高约15%;截面长度和混凝土强度等级对承载力、初始刚度和延性系数的影响均小于15%,纵向距离对其受剪性能几乎无影响。结论 采用钢管混凝土键连接梁墙的结构总体受剪性能优于现浇结构;钢材强度和截面厚度分别是影响初始刚度和承载力的主要因素。 展开更多
关键词 钢管混凝土键 框架-剪力墙结构 梁墙试件 抗剪性能 有限元分析
下载PDF
反复荷载下圆钢管型钢再生混凝土组合柱恢复力模型研究 被引量:2
12
作者 马辉 刘一 +1 位作者 赵艳丽 白恒宇 《计算力学学报》 CAS CSCD 北大核心 2024年第2期320-327,共8页
为建立圆钢管型钢再生混凝土组合柱的恢复力模型,对11根圆钢管型钢再生混凝土组合柱试件进行了低周反复荷载试验研究,考虑了再生骨料取代率、配钢率及钢管径厚比等不同设计参数的影响,分析了组合柱的地震破坏形态及滞回性能。基于组合... 为建立圆钢管型钢再生混凝土组合柱的恢复力模型,对11根圆钢管型钢再生混凝土组合柱试件进行了低周反复荷载试验研究,考虑了再生骨料取代率、配钢率及钢管径厚比等不同设计参数的影响,分析了组合柱的地震破坏形态及滞回性能。基于组合柱的力学特征及曲线形状,提出了圆钢管型钢再生混凝土组合柱骨架曲线的三折线参数模型,采用理论推导与数据拟合的方法确定了组合柱骨架曲线的模型参数。在此基础上,给出了组合柱的滞回规则和卸载规律,构建了组合柱的恢复力模型,计算滞回曲线与试验滞回曲线吻合良好,表明该恢复力模型较好地反映了反复荷载下组合柱的受力特征点及滞回性能,可为此类组合柱的推广提供技术参考。 展开更多
关键词 型钢再生混凝土 钢管再生混凝土柱 恢复力模型 骨架曲线 滞回曲线
下载PDF
圆钢管型钢再生混凝土组合柱水平承载力计算方法研究 被引量:1
13
作者 王磊 《建筑结构》 北大核心 2024年第8期20-26,共7页
通过对11个圆钢管型钢再生混凝土组合柱进行低周反复荷载试验,分析再生粗骨料取代率、型钢截面形式、轴压比、型钢配钢率及圆钢管壁厚参数对组合柱水平承载力的影响规律;观察了组合柱的破坏形态及特征,研究了圆钢管、型钢翼缘及腹板应... 通过对11个圆钢管型钢再生混凝土组合柱进行低周反复荷载试验,分析再生粗骨料取代率、型钢截面形式、轴压比、型钢配钢率及圆钢管壁厚参数对组合柱水平承载力的影响规律;观察了组合柱的破坏形态及特征,研究了圆钢管、型钢翼缘及腹板应变的发展规律,分析了组合柱的地震破坏特征。研究表明,在水平地震作用下组合柱发生典型的压弯塑性铰破坏。在此基础上,结合现有规范提出了基于叠加原理的圆钢管型钢再生混凝土组合柱水平承载力计算方法。计算结果表明,其水平承载力计算值与试验值吻合度较好,能较为准确地预测组合柱的水平承载力。 展开更多
关键词 型钢再生混凝土 圆钢管混凝土柱 破坏机理 低周反复荷载试验 水平承载力 计算方法
下载PDF
功能可恢复RCS混合框架结构研究进展
14
作者 刘阳 钟沛杰 +3 位作者 门进杰 陈云 刘小娟 黄玉佳 《华侨大学学报(自然科学版)》 CAS 2024年第2期121-135,共15页
钢筋混凝土柱-钢梁(RCS)混合框架结构以其结合了混凝土优异的抗压性能及钢材优异的抗弯性能而受到广泛关注,而可恢复功能结构以其震后快速恢复使用功能的能力,也成为地震工程界研究的新热点。功能可恢复RCS混合框架结构可以在弯矩较大... 钢筋混凝土柱-钢梁(RCS)混合框架结构以其结合了混凝土优异的抗压性能及钢材优异的抗弯性能而受到广泛关注,而可恢复功能结构以其震后快速恢复使用功能的能力,也成为地震工程界研究的新热点。功能可恢复RCS混合框架结构可以在弯矩较大的梁端和柱脚部位设置可更换构件,实现结构的功能可恢复能力。文中简述了近年来功能可恢复RCS混合框架结构研究进展,重点关注各类型功能可恢复钢梁、功能可恢复摇摆柱脚的构造研究,介绍了功能可恢复RCS混合框架结构性能分析研究进展。最后,对功能可恢复RCS混合框架结构仍需深入研究的问题进行了展望。 展开更多
关键词 钢筋混凝土柱-钢梁(RCS)混合框架结构 可恢复功能 防震结构 钢板阻尼器 柱脚 梁柱节点
下载PDF
开槽侧板加强型连接梁柱节点子结构抗连续倒塌性能研究
15
作者 张旺 王岩 +3 位作者 刘红波 熊清清 贾世杨 苏天成 《建筑结构》 北大核心 2024年第14期23-30,共8页
为了优化侧板加强型节点的抗连续倒塌性能,提出了一种开槽侧板加强型梁柱连接节点形式。通过静力加载试验,得到了新型节点子结构的破坏模式、竖向抗力发展机制、应变分布、延性水平和动力承载力等。试验结果表明:钢梁翼缘在盖板附近首... 为了优化侧板加强型节点的抗连续倒塌性能,提出了一种开槽侧板加强型梁柱连接节点形式。通过静力加载试验,得到了新型节点子结构的破坏模式、竖向抗力发展机制、应变分布、延性水平和动力承载力等。试验结果表明:钢梁翼缘在盖板附近首先开裂并向腹板外排螺栓中部延伸贯穿,导致竖向承载力快速下降为峰值荷载的20%左右。相比传统侧板加强型和圆弧扩盖板型梁柱节点,新型节点的峰值承载力分别提高了62.1%和19.6%,塑性弦转角分别提高了203.6%和25.8%。通过有限元分析得到了试件的断裂路径发展过程,进一步地通过参数化分析发现:扩大过焊孔构造对改善峰值后塑性弦转角及残余强度提升无明显作用;随着螺栓群远离钢梁翼缘起始断裂位置,最小残余强度比不断增大,但峰值后塑性弦转角呈先增大后减小的趋势;当螺栓群内移45mm时,峰值后塑性弦转角及最小残余强度比分别达到0.149rad和0.88,提高了38.2%和200.8%。 展开更多
关键词 钢管混凝土组合柱 梁柱节点 抗连续倒塌性能 延性评估 参数化分析
下载PDF
爆炸荷载下预制节段拼装双层钢管混凝土墩柱的动力响应数值模拟
16
作者 李明鸿 刘晏辰 +3 位作者 夏梦涛 宗周红 甘露 陈振健 《东南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2024年第3期647-657,共11页
为提升装配式公路桥梁的抗爆防护能力,提出了一种新型预制节段拼装双层钢管混凝土(PS-CFDST)组合墩柱.基于非线性显式动力分析程序LS-DYNA建立了新型PS-CFDST墩柱在爆炸荷载作用下动力响应分析的精细有限元模型,并通过已有试验结果验证... 为提升装配式公路桥梁的抗爆防护能力,提出了一种新型预制节段拼装双层钢管混凝土(PS-CFDST)组合墩柱.基于非线性显式动力分析程序LS-DYNA建立了新型PS-CFDST墩柱在爆炸荷载作用下动力响应分析的精细有限元模型,并通过已有试验结果验证了模型的准确性.对爆炸荷载作用下PS-CFDST墩柱的动力响应进行数值模拟分析,研究了PS-CFDST墩柱在爆炸荷载作用下的破坏过程、损伤机理和耗能机制.运用参数化分析方法,研究了爆炸距离、节段数量和预应力水平等关键参数对PS-CFDST墩柱动力响应的影响,并在此基础上提出了PS-CFDST墩柱的抗爆设计建议.结果表明:PS-CFDST墩柱除通过材料塑性损伤耗能之外,节段接缝界面滑移耗能机制对耗能贡献可达40%以上;增大墩柱可接近距离是提升墩柱抗爆安全性的有效手段,增大预应力有利于减小柱中最大水平位移和墩底剪切滑移,从而提升PS-CFDST墩柱的抗爆性能. 展开更多
关键词 预制节段拼装墩柱 双层钢管混凝土 数值模拟 爆炸荷载 动力响应 损伤机理
下载PDF
基于机器学习的CFST柱高温剩余强度系数预测方法
17
作者 宋岩升 肖广 +1 位作者 王浩然 王光远 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2024年第5期867-875,共9页
目的 为提高计算精度和速度,利用机器学习模型泛化数据,以预测CFST柱的高温剩余强度系数。方法 利用生成对抗网络将搜集到的110个试验结果泛化生成407组数据,据此训练机器学习模型,并使用试验结果评估其性能,以确定最优模型;然后使用生... 目的 为提高计算精度和速度,利用机器学习模型泛化数据,以预测CFST柱的高温剩余强度系数。方法 利用生成对抗网络将搜集到的110个试验结果泛化生成407组数据,据此训练机器学习模型,并使用试验结果评估其性能,以确定最优模型;然后使用生成数据输入建立的模型预测CFST柱高温剩余强度系数,并和现有计算方法进行对比。结果 建立的随机森林模型在性能度量上表现最好,拟合优度达到0.947 7,均方误差为0.001 8,精度为94.7%;预测结果误差在±10%内的数据为83%,在±20%内的数据为100%;剩余强度系数主要影响因素依次为温度、钢材屈服强度、混凝土抗压强度和横截面积,钢管厚度影响很小。结论 提出的预测方法优于现有计算方法,具有更快的计算速度、更小的结果误差以及更强的模型可解释性,该方法可为CFST柱抗火设计提供参考。 展开更多
关键词 钢管混凝土柱 剩余强度系数 机器学习 抗火设计
下载PDF
乌兹别克斯坦9度区某超高层建筑结构设计与优化
18
作者 闫锋 花炳灿 安东亚 《建筑结构》 北大核心 2024年第13期51-56,共6页
对于9度设防地区的超高层建筑,其结构设计基本由地震作用控制,因此抗震设计尤为重要。建筑消能减震技术可在提高结构地震安全储备的同时,降低整体工程造价,是结构优化设计的有效措施。对位于9度区的超高层建筑进行了结构方案选型对比、... 对于9度设防地区的超高层建筑,其结构设计基本由地震作用控制,因此抗震设计尤为重要。建筑消能减震技术可在提高结构地震安全储备的同时,降低整体工程造价,是结构优化设计的有效措施。对位于9度区的超高层建筑进行了结构方案选型对比、结构方案优化、减震设计方案比选、剪力墙内嵌钢板优化。结果显示,钢骨混凝土框架⁃核心筒方案相对于钢框架⁃支撑方案具备更高的成本优势;框架⁃核心筒方案可通过精细化设计作进一步优化;在此基础上,对钢骨混凝土框架⁃核心筒方案采用两种消能减震方案进行比选,结果表明,采用黏滞阻尼器方案的结构抗震性能明显优于采用黏滞阻尼墙方案;最后通过增大剪力墙竖向分布钢筋配筋率,对低区核心筒墙肢中的内嵌钢板进行了优化。 展开更多
关键词 9度抗震设防 超高层建筑 钢骨混凝土结构 框架⁃核心筒 消能减震
下载PDF
高温后钢管高强混凝土柱的黏结性能
19
作者 王兵 郁舒敏 +2 位作者 刘晓 侯东序 崔洧瑄 《沈阳大学学报(自然科学版)》 CAS 2024年第1期54-60,共7页
为了研究高温后钢管高强混凝土柱的黏结性能,通过有限元软件ABAQUS建立模型,并与已有试验结果进行验证,吻合良好。研究表明:钢管高强混凝土柱的黏结应力随着温度的升高呈现出先增加后减小的趋势;黏结应力随着混凝土强度的增大而增大,随... 为了研究高温后钢管高强混凝土柱的黏结性能,通过有限元软件ABAQUS建立模型,并与已有试验结果进行验证,吻合良好。研究表明:钢管高强混凝土柱的黏结应力随着温度的升高呈现出先增加后减小的趋势;黏结应力随着混凝土强度的增大而增大,随着径厚比的增大而减小;长径比在2.74~7.72的范围内,随着长径比的增加,黏结力逐渐增加;黏结界面破坏的速度随温度的增加而减缓;随着温度的增加耗能因子呈现先增大后减小的趋势。 展开更多
关键词 高温 黏结滑移 钢管高强混凝土柱 耗能因子 有限元模拟
下载PDF
钢管预置集料混凝土中长柱受压性能试验
20
作者 吕晶 郑健龙 +2 位作者 韩文超 张金翼 赵欢 《中南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2024年第6期2247-2259,共13页
为了探究钢管预置集料混凝土中长柱受压性能,首先,考虑混凝土类型、混凝土强度、径厚比、长径比和偏心率等参数影响,设计了11根钢管预置集料混凝土中长柱和3根普通钢管混凝土中长柱;其次,通过轴压和偏压试验,并结合有限元分析法,研究了... 为了探究钢管预置集料混凝土中长柱受压性能,首先,考虑混凝土类型、混凝土强度、径厚比、长径比和偏心率等参数影响,设计了11根钢管预置集料混凝土中长柱和3根普通钢管混凝土中长柱;其次,通过轴压和偏压试验,并结合有限元分析法,研究了试件破坏形态、承载力、变形特征等变化规律;最后,基于极限平衡理论,提出了适用于钢管预置集料混凝土中长柱轴压与偏压承载力计算公式。研究结果表明:钢管预置集料混凝土中长柱破坏形态与普通钢管混凝土中长柱的破坏形态相似,均为弯曲失稳破坏;钢管预置集料混凝土中长柱承载能力与普通钢管混凝土中长柱承载能力相当,但钢管预置集料混凝土试件轴向刚度是普通钢管混凝土试件轴向刚度的1.2倍左右,表现出良好的抗变形能力;钢管预置集料混凝土中长柱径厚比由39.75降低至19.88,承载能力提高33.8%;长径比由6增大至15时,承载能力降低20.5%;偏心率由0.25增大至1.0时,承载力降低49.5%;钢管预置集料混凝土中长柱稳定系数受混凝土强度和径厚比影响较小,但随着长径比和偏心率增大而近乎呈线性降低趋势。本文提出的承载力计算公式可为钢管预置集料混凝土中长柱设计提供参考。 展开更多
关键词 钢管混凝土 预置集料混凝土 中长柱 受压性能 承载力计算方法